• Title/Summary/Keyword: 신장기능 검사

Search Result 156, Processing Time 0.026 seconds

Optimization of GFR value according to Kidney Depth Measurement Methods (신장 Depth 측정 방법에 따른 GFR 값의 최적화)

  • Kwon, Hyeong-Jin;Moon, Il-Sang;Noh, Gyeong Woon;Kang, Keon Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.25-28
    • /
    • 2019
  • Purpose In patients with unusual kidney position after $^{99m}Tc-DTPA$ renal dynamic imaging study, the GFR(Glomerular Filtration Rate) values are significantly different according to the depth of the kidney. Thus, we tried to compare the difference of the GFR values between the depth measurement methods and in-vitro test. 30 adult patients who were subjected to renal study. 27 patients were in usual position and 3 patients were in unusual. $555{\pm}37MBq$ of $^{99m}Tc-DTPA$ was administrated to all patients. GE infinia gamma camera was used. GFR values were obtained in-vivo(gates method) and in-vitro(blood). The kidney depth in-vivo was calculated by three methods(tonnensen, manual, taylor). In-vitro, GFR was performed by blood test. Differences in the mean values of GFR and correlation between depth and GFR values were evaluated using the SPSS 12.0 statistical program. The GFR values for 27 patients with kidney in the usual position are as follows(1.tonnensen 2.manual 3.taylor 4.invitro); $69.3{\pm}4.2$, $88.2{\pm}5.6$, $77.8{\pm}4.3$, $82.2{\pm}5.8ml/min$. The three unusual cases are as follows, first(congenital renal anomaly): 66.4, 101.24, 69.07, 94.8 ml/min. second(transplantation kidney): 12.22, 29.99, 19.36, 23.5 ml/min. third(horseshoe kidney): 37.37, 93.54, 35.9, 92.5 ml/min. There was a difference between tonnensen and manual in the usual position of the kidney(p<0.05). There was no significant difference between the other methods. However, there was a significant difference in case of the unusual position of the kidneys. Correlation analysis between both kidney depth and GFR value shows person correlation as follows; Rt kidney: 0.298, Lt kidney: 0.322. When compared with the GFR values in-vitro test, it was useful to calculate the GFR value by measuring the kidney depth using a manual formula in the unusual position of the kidneys. GFR values and kidney depth were significantly related.

A Study of Bone Uptake According to Renal Function in the Whole Body Bone Scan (전신 뼈 검사에서 신장 기능에 따른 뼈 섭취율에 대한 고찰)

  • Cho, Yong-In;Jang, Dong-Gun;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.299-304
    • /
    • 2013
  • Whole body bone scan has been used to confirm bone metastasis and follow-up study with radio isotope. However, if the factors related to $^{99m}Tc$ uptake and waiting time for study are inappropriate, it would be image of low quality. The purpose of present study was to investigate correlation between the evaluation index of renal function and uptake of radiopharmaceuticals. The population for this retrospective study consisted of 387 patients who underwent whole body bone scan between June 2012 and December 2012. As a result of quantitative and qualitative analysis, we were able to confirm that GFR of less than normal range and creatinine levels in blood of more than average are more likely to be under the mean uptake rate. As a result of analysis on the indicator affecting soft-tissue and bone uptake, the correlation of all elements was somewhat low. Also there are no statistically significances due to the other parameters we did not deal with. Therefore, further research on additional factors is needed for exact study and improvement of the image quality.

Attenuation of Ischemia-Reperfusion Injury by Antioxidant Vitamins in a Pig Model of Renal Auto-Transplantation (돼지의 신장 자가이식에서 Ascorbic Acid와 Alpha-tocoperol 의한 허혈 및 재관류 손상의 감소)

  • Kim, Myung-Jin;Lee, Jae-Yon;Cho, Sung-Whan;Park, Chang-Sik;Jun, Moo-Hyung;Jeong, Seong-Mok;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.26 no.1
    • /
    • pp.29-35
    • /
    • 2009
  • This study was to determine the effects of ascorbic acid and alpha-tocopherol on the attenuation of an ischemia-reperfusion injury (IRI) after renal auto-transplantation in a pig model. In the treatment group, three pigs were subjected to a renal auto-transplantation followed by the administration of ascorbic acid and alpha-tocopherol and the flushing of ascorbic acid plus hepa-saline solution. Otherwise, the control group used only flushing of hepa-saline solution. Blood samples were collected from these pigs for measurement of serum blood urea nitrogen (BUN) and creatinine values on the day before surgery and day 1, 3, 5 and 7 after surgery. The kidneys were taken for histopathological evaluation following euthanasia on day 14 after surgery. Serum creatinine and BUN values showed a significantly difference between control and treatment group on day 1, 3 and 5 (P<0.05). In histopathologic findings, treatment group showed less damage than that of the control group on the basis of renal tubular damage. As a result, this study suggests that the exogenous ascorbic acid and alpha-tocopherol pretreatment therapy with ascorbic acid irrigation-aspiration has a role of attenuation of renal I/R injury and recovery of renal function in a pig transplantation model.

Evaluation on Reproducibility of Low-Dose Kidney Scan in Dynamic Kidney Scan (동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가)

  • Lee, Jaesang;Lee, Kyuchan;Lee, Seunghwan;Bae, Seongbok;Park, Jongyeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.59-65
    • /
    • 2016
  • Purpose Dynamic kidney scan is a typical imaging technique that visualizes kidney function. Reproducibility of dynamic kidney scans has been evaluated by comparing low-dose kidney scans with low-dose radiopharmaceutical and standard dynamic kidney scan. With this comparative study, if reproducibility is superb, the dynamic kidney scan method with reduced radioactivity to patients is to be utilized and radiation exposure to patient is to be reduced. Materials and Methods For gamma camera, Orbiter, SymbiaE (Siemens, Germany) was used. Among patients who had used 370 Mbq (10 mCi) from January of 2013 to February 2014 and other patients who had used 185 Mbq (5 mCi) from March of 2014 to July of 2015 with identical condition, 21 subjects using DTPA and 20 subjects using $MAG_3$, 41 subjects in total, had been selected as subjects for data. From renogram of the result image, frame of the peak point was selected. Then, region of interest of kidney and background had been selected and Kidney to Background Ratio has been calculated for comparison. Results In tests using DTPA, kidney to background ratio when using 370 Mbq was $5.67{\pm}0.8$ at average while it was $5.62{\pm}0.87$ when using 185 Mbq, which didn't show much difference. Also in the tests using $MAG_3$, kidney to background ratio when using 370 Mbq was $14.95{\pm}2.58$ at average and $14.56{\pm}2.02$ in 185 Mbq, which neither showed much difference. In paired sample t-test, p-value was 0.566 in DTPA and 0.363 in $MAG_3$, which confirmed that there was no difference between the groups. Conclusion In identical patients, when dose was decreased from 370 Mbq to 185 Mbq, reproducibility of dynamic kidney scan was proven to be excellent. Low-dose Dynamic kidney scan can achieve results with fine reproducibility without improvement in performance of gamma camera and is expected to reduce radiation exposure to patient.

  • PDF

Clinical Manifestation of Children with Failure to Thrive (Failure to Thrive를 주소로 내원한 환아들의 임상상)

  • Moon, Jeong-Hee;Kim, Ji-Young;Beck, Nam-Sun
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.3 no.1
    • /
    • pp.68-74
    • /
    • 2000
  • Purpose: This study was to investigate the clinical manifestations of FTT in children. Methods: From March 1997 to July 1999, clinical observations were made on patients with FTT who had visited to Samsung Medical Center. Detailed histories and through physical examinations were taken, and when suspected organic FTT, basic laboratory studies were done. Results: Upon the review of medical records, we investigated the clinical manifestations of 74 children, aged 1 month and 13 year 1 month. The causes of FTT were composed of either physiologic (47.8%) or pathologic (52.2%) ones. Among the physiologic FTT, were there familial short stature (FSS, 14.5%), intrauterine growth retardation (IUGR, 14.5%), constitutional growth delay (CGD, 11.6%), idiosyncrasy and prematurity. Among pathologic causes, neurologic disorders (20%) are the most common causes of FTT, and then follow by GI (13.4%), allergic and infectious disorders in decreasing order. The data showed that average caloric intake in patients with FTT was 76,2% of recommended amount. FTT patients with CGD, IUGR, and idiosyncrasy had tendency to take small foods. The FTT children with prematurity, IUGR and pathologic FTT, were short and thin for their ages. However FTT children with CGD and FSS had tendency to be thin with relatively normal heights for their ages, in comparison with those of the children with prematurity, IUGR and pathologic FTT. Conclusion: The diagnosis of FTT was easily obtained with simple and through medical history, physical examination, and minimal laboratory tests. In this study, organic FTT was more prevalent than physiologic one. This results indicate that early intervention is mandatory, because children may develop significant long-term sequelae from nutritional deficiency.

  • PDF

Biochemical Changes and Recovery After Half-course Marathon (하프코스 마라톤 후 체내의 생화학적 변화 및 회복)

  • Choi, Chang-Hyuk;Lee, Hyun-Sub;Seo, Hun-Suk;Kim, Sang-Kyung;Shin, Im-Hee
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.1
    • /
    • pp.45-49
    • /
    • 2008
  • Purpose: To evaluate the recovery time of biochemical changes of body after half-course marathon running. Materials and methods: Thirteen amateur half course marathon runners (12 males and 1 females) were studied. Their average age was 44 years old (range: $38{\sim}54$). Biochemical parameters with blood test including AST, ALT, CK-MB, Treponin, BUN, Cr Na, K were evaluated at finish line, 2nd days, 2nd weeks after running. Results: All the biochemical changes were within normal range throughout recovery time, AST reached its maximum level at finish line and continued until 2nd day after running and returned its pre-running level at 2nd week's test. CK-MB reached its maximum level 2nd day after running and recovered at 2nd week's test. Na, K, BUN and Cr reached to the maximum level at finish line, and recovered to pre-running level at 2nd day's test. Conclusion: In case of half-course marathon, the changes of the kidney enzymes due to dehydration were recovered after 2nd day. And the biochemical indicators of muscle fatigue recovered after 2nd week. It needs at least 2 weeks rest after half-course marathon to recover all the biochemical parameter of the body.

  • PDF

Clinical Usefulness of 99mTc-DMSA Renal SPECT Using High Sensitivity-All Purpose Collimator for Pediatric Patients (고감도 범용성 콜리메이터를 이용한 소아 환자 99mTc-DMSA 신장 SPECT의 유용성)

  • Kim, Jin-Eui;Kim, Jung-Soo;Han, Jae-Bok;Choi, Nam-Gil
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.219-231
    • /
    • 2016
  • $^{99m}Tc$-DMSA planar scan that can analyze the functions of kidney quantitatively provides less information on a lesion than tomography scanning. Therefore, this study applied a high sensitivity all-purpose collimator that is sensitive to photonic signals to $^{99m}Tc$-DMSA and carried out a clinical scan with single photon emission computed tomography (SPECT). And diagnostic accuracy and time requirement of were analyzed to know the clinical usefulness of the applied scanning method. 10 subjects were intravenously injected with radiopharmaceutical product (1.0-1.2 MBq/kg) and scanned by a gamma camera with planar scanner (high resolution (HR)-mode, $256{\times}256$, 50 kcts/view, 4 image) and SPECT (HR / high sensitive (HS)-mode, $128{\times}128$, step and shoot, $180^{\circ}$, variable sec/angle, total 64 frame, OSEM reconstruction), respectively. The collected data was compared with an analysis program. The results showed that HS-mode SPECT detected total counts 1.8-5.6 times more than planar scan. Relative renal function evaluated based on the counts was not significantly different by two scanning methods (p=0.96) and it turned out that test time was shortened by 39% when HS-mode SPECT was used. Therefore, SPECT using HR, HS-mode collimator could analyze renal function more quantitatively than using planar scan and the former could diagnose the location information of a lesion more accurately than the latter as well as shortened test time requirement, which demonstrated the clinical usefulness of $^{99m}Tc$-DMSA renal SPECT using high sensitivity all purpose collimator.

The Value of Tc-99m DTPA Diuretic Renography for Assessment of Dilated Upper Urinary Tract in Children (소아의 상부 요관확장증에서 폐쇄 유무 감별에 있어 Tc-99m DTPA 이뇨 신장 신티그램의 유용성)

  • Yang, Ki-Ra;Lim, Gye-Yeon;Sohn, Hyung-Sun;Hahn, Seong-Tae;Lee, Jae-Mun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.57-64
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate the accuracy of Tc-99m DTPA diuretic renal scans in children with dilated upper urinary tract. Materials and Methods: We reviewed diuretic renal scans of 14 pediatric patients (age range: 3 days to 4 years) with unilateral hydronephrosis diagnosed by ultrasonography. Diuretic renal scan was done using Tc-99m DTPA and standardized protocol. In 3 neonates, diuretic renal scans were performed within 1 week and 3-7 months after birth. Results: Six patients required Pyeloplasty and eight were managed conservatively. All 6 patients requiring Pyeloplasty were diagnosed as having ureteropelvic junction obstruction in the diuretic renal scan. In these 6 patients, post-operative renal scans at 3-12 months after surgery were converted to nonobstructive pattern in 5 and a nonfunctioning pattern in 1. In 3 patients who underwent diuretic renal scan within 1 week after birth, nonobstructive patterns of initial scan were converted to obstructive patterns in the follow-up scan. However, all patients with nonobstructive diuretic renal scans performed after the neonatal period did well on serial ultrasonography and showed favorable clinical outcome without progression to obstruction. Conclusion: Tc-99m DTPA diuretic renal scan with standardized protocol is useful in assessing suspected ureteropelvic junction obstruction in children as an initial diagnostic or post-operative follow-up modality. Nonobstructive or indeterminate scan results in the neonatal period requires follow-up scan to monitor development of the obstructive pattern.

  • PDF

Development of Smart Application for English Speaking (영어 말하기 능력 신장을 위한 스마트 앱 개발)

  • Ryu, Miyoung;Han, Seonkwan
    • Journal of The Korean Association of Information Education
    • /
    • v.20 no.4
    • /
    • pp.367-374
    • /
    • 2016
  • In this study, we proposed the development of smart application for English speaking effectively. First, to develop English learning application, we applied the TTS feature to record your own sounds and learning theory repeated listening and speaking that is the basis of English learning. To analyze the effectiveness of the application, we applied a lesson to elementary students for 4 months. In the test result, we found that all students have advanced to the English speaking ability and the test results of the affective factors showed a positive response to most students.