• Title/Summary/Keyword: 신신호 시스템

Search Result 196, Processing Time 0.028 seconds

Standardization Analysis of 'NEC Article 690' for Photovoltaic Shutdown Technology (태양광(PV) 셧다운(Shutdown)기술 'NEC Article 690' 표준화 분석)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.3
    • /
    • pp.171-176
    • /
    • 2022
  • The communication signal for quick cut-off specification is defined as "design to support fast cut-off requirements of all applicable photovoltaic(PV) systems" in NEC 2014, NEC 2017 or the corresponding UL standard regardless of the system configuration. On the other hand, if you look at the domestic regulations related to new and renewable energy, the standards, regulations, and guidelines set by each institution are general, or only the parts necessary for the institution are being established and operated. There are many insufficient points to apply these things to photovoltaic facilities, and there are cases where excessive facilities are installed according to the design, inspection standards of supervisors and inspection agencies, and the skill level of inspectors. The internationally accepted IEC standards deal with various facility standards in detail. In each European country, there are separate facility regulations based on IEC. In particular, the performance and safety of devices are dealt with in detail, and in the case of 'NEC Article 690' applied in North America such as the United States, each item is described in detail. Therefore, in this paper, we will look at the details of the PV shutdown technology that is currently used and applied internationally.

A Design of Software Receiver for GNSS Signal Processing

  • Choi, Seung-Hyun;Kim, Jae-Hyun;Shin, Cheon-Sig;Lee, Sang-Uk;Kim, Jae-Hoon
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.2
    • /
    • pp.48-52
    • /
    • 2007
  • Recently, the research of GPS receiver which uses the Software-Defined Radio(SDR) technique is being actively proceeded instead of traditional hardware-based receiver. The software-based GPS receiver indicates that the signal acquisition and tracking treated by the hardware-based platform are processed as the software technique through a microprocessor. In this paper, GPS software receiver is designed by using SDR technique and then the signal acquisition, tracking, and the navigation message decoding parts are verified through the PC-based simulation. Moreover, the efficient algorithms are developed about the signal acquisition and tracking parts in order to obtain the accurate pseudorange. Finally, the pseudorange is calculated through the relative channel delay received through the different satellite of L1 frequency band. GPS software receiver proposed in this paper will be included in the element of GPS/Galileo complex system of development target and will provide not only the method that verifies the performance for Galileo Sensor Station standard but also usability by providing various debugging environments.

  • PDF

Design of FPGA Camera Module with AVB based Multi-viewer for Bus-safety (AVB 기반의 버스안전용 멀티뷰어의 FPGA 카메라모듈 설계)

  • Kim, Dong-jin;Shin, Wan-soo;Park, Jong-bae;Kang, Min-goo
    • Journal of Internet Computing and Services
    • /
    • v.17 no.4
    • /
    • pp.11-17
    • /
    • 2016
  • In this paper, we proposed a multi-viewer system with multiple HD cameras based AVB(Audio Video Bridge) ethernet cable using IP networking, and FPGA(Xilinx Zynq 702) for bus safety systems. This AVB (IEEE802.1BA) system can be designed for the low latency based on FPGA, and transmit real-time with HD video and audio signals in a vehicle network. The proposed multi-viewer platform can multiplex H.264 video signals from 4 wide-angle HD cameras with existed ethernet 1Gbps. and 2-wire 100Mbps cables. The design of Zynq 702 based low latency to H.264 AVC CODEC was proposed for the minimization of time-delay in the HD video transmission of car area network, too. And the performance of PSNR(Peak Signal-to-noise-ratio) was analyzed with the reference model JM for encoding and decoding results in H.264 AVC CODEC. These PSNR values can be confirmed according the theoretical and HW result from the signal of H.264 AVC CODEC based on Zynq 702 the multi-viewer with multiple cameras. As a result, proposed AVB multi-viewer platform with multiple cameras can be used for the surveillance of audio and video around a bus for the safety due to the low latency of H.264 AVC CODEC design.

Design of a Readout Circuit of Pulse Rate and Pulse Waveform for a U-Health System Using a Dual-Mode ADC (이중 모드 ADC를 이용한 U-Health 시스템용 맥박수와 맥박파형 검출 회로 설계)

  • Shin, Young-San;Wee, Jae-Kyung;Song, Inchae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.68-73
    • /
    • 2013
  • In this paper, we proposed a readout circuit of pulse waveform and rate for a U-health system to monitor health condition. For long-time operation without replacing or charging a battery, either pulse waveform or pulse rate is selected as the output data of the proposed readout circuit according to health condition of a user. The proposed readout circuit consists of a simple digital logic discriminator and a dual-mode ADC which operates in the ADC mode or in the count mode. Firstly, the readout circuit counts pulse rate for 4 seconds in the count mode using the dual-mode ADC. Health condition is examined after the counted pulse rate is accumulated for 1 minute in the discriminator. If the pulse rate is out of the preset normal range, the dual-mode ADC operates in the ADC mode where pulse waveform is converted into 10-bit digital data with the sampling frequency of 1 kHz. These data are stored in a buffer and transmitted by 620 kbps to an external monitor through a RF transmitter. The data transmission period of the RF transmitter depends on the operation mode. It is generally 1 minute in the normal situation or 1 ms in the emergency situation. The proposed readout circuit was designed with $0.11{\mu}m$ process technology. The chip area is $460{\times}800{\mu}m^2$. According to measurement, the power consumption is $161.8{\mu}W$ in the count mode and $507.3{\mu}W$ in the ADC mode with the operating voltage of 1 V.

A Study on the Implementation of Coexistent Reality Technology for Ship Outfitting Inspection (선박 의장 검사를 위한 공존현실 기술 적용에 관한 연구)

  • Ha, Yeon-Chul;Kim, Jin-Woo;Kim, Goo;Shin, Hyun-Shil
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.1
    • /
    • pp.13-20
    • /
    • 2020
  • In shipyards, internal materials are assembled after designing and manufacturing each ship's block. Internal material assembly means the installation of parts and equipment except ship's body. In this process, if the assembly of pipes and equipment existing in the block is not done correctly during the assembly between blocks, this causes a lot of costs. In addition, even if the assembly of the internal materials already completed, the production efficiency of the ship is reduced due to rework when problems such as space arrangement of the internal materials occurs. Therefore, this study introduces space arrangement and inspection system before and after hull outfitting work based on coexistence reality technology using 3D design drawing to solve these problems. The various coexistence reality algorithms and inspection systems developed and introduced in this study are based on AR service, which has never been introduced in Korea. So it will be widely applicable to various manufacturing industries using design drawings such as automobiles and architectures as well as ship building process.

Wi-Fi Based Indoor Positioning System Using Hybrid Algorithm (하이브리드 알고리즘을 이용한 Wi-Fi 기반의 실내 측위 시스템)

  • Shin, Geon-Sik;Shin, Yong-Hyeon
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.6
    • /
    • pp.564-573
    • /
    • 2015
  • GPS is the representative positioning technology for providing the location information. This technique has the disadvantage that does not operate in the shadow areas, such as urban or dense forest and the interior. This paper proposes a hybrid indoor positioning algorithm, which estimates a more accurate location of the terminal using strength of the Wi-Fi signal from the indoor AP. To determine the location of the user, we establish the most appropriate path loss model for the measurement environment. by using the RSSI value measured in a variety of environment such as building structure, person, distance, etc. The path loss exponent obtained by the path loss model is changed according to the environment. REKF, PF estimate the position of the terminal by using measured value from the AP with path loss exponent. For more accurate position estimation, we select positioning system by the value of threshold measured by experiments rather than a single positioning system. Experimental results using the proposed hybrid algorithm show that the performance is improved by about 17% than the conventional single positioning method.

Development of Millimeter wave Transmitter and Receiver for Long Distance Wireless Transmission Using NRD waveguide (NRD 가이드를 이용한 장거리 무선통신용 밀리미터파 대역 송수신기 개발)

  • Park Sung-Hyun;Kim Soo-Hwan;hin Cheon-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.9A
    • /
    • pp.867-875
    • /
    • 2005
  • In this paper, we fabricated along distance wireless communication transmitter and receiver over the 100 which used NRD technology. To make the transmitter and receiver of 400Hz band using the non radiative dielectric wave guide, transmitter was composed of gm oscillator, m modulator and antenna, receiver was composed of local gum oscillator, balanced mixer, 3dB direction coupler and antenna. Also we executed a wireless communication image transmission examination to the transmitter and receiver. We receive the image information in real-time data transmission from receiver after we send the image signal in the wireless distance of the 10km. Therefore, the 400Hz band U transmitter and receiver to be developed will be used widely for the transmission system CATV or broadband transmission system. This will be utilized also to the link device of a long distance high speed wireless communication network.

Analysis on the Performance of $2{\times}1$ Alamouti Scheme in Time-varying and Spatially Correlated Channels (시변 및 공간 상관 채널 환경에서 $2{\times}1$ 알라마우티 구조 (Alamouti Scheme)의 성능 분석)

  • Lee, Eun-Ju;Park, Jae-Don;Yoon, Gi-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.539-542
    • /
    • 2011
  • In this paper, we have implemented a performance analysis of $2{\times}1$ Alamouti scheme suggested by Alamouti, composed of the transmit space-time code and the simple linear decoding processing, in perfectly time-varying and spatially correlated channels. In addition, we derived the closed-form probability density function (PDF) of the output signal-to-noise ratio (SNR) and the outage probability of the Alamouti scheme as a function of the spatial correlation coefficient in the consideration of no correlation in time. As a result, it was found that the performance of the Alamouti scheme could be significantly degraded particularly in the case that the channels are time-varying and spatially correlated.

  • PDF

Doppler Radar System for Noncontact Bio-signal measurement (비접촉 방식의 생체 신호 측정을 위한 도플러 레이더 시스템)

  • Shin, Jae-Yeon;Cho, Sung-Pil;Jang, Byung-Jun;Park, Ho-Dong;Lee, Yun-Soo;Lee, Kyoung-Joung
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.357-359
    • /
    • 2009
  • In this paper, the 2.4GHz doppler radar system consisting of the doppler radar module and a baseband module were designed to detect heartbeat and respiration signal without direct skin contact. A bio-radar system emits continuous RF signal of 2.4GHz toward human chest, and then detects the reflected signal so as to investigate cardiopulmonary activities. The heartbeat and respiration signals acquired from quadrature signal of the doppler radar system are applied to the pre-processing circuit, amplification circuit, and the offset circuit of the baseband module. ECG(electrocardiogram) and reference respiration signals are measured simultaneously to evaluate the doppler radar system. As a result, the respiration signal of doppler radar signal is detected to 1m without complex digital signal processing. The sensitivity and calculated from I/Q respiration signal were $98.29{\pm}1.79%$, $97.11{\pm}2.75%$, respectively, and positive predictivity were $98.11{\pm}1.45%$, $92.21{\pm}10.92%$, respectively. The sensitivity and positive predictivity calculated from phase and magnitude of the doppler radar were $95.17{\pm}5.33%$, $94.99{\pm}5.43%$, respectively. In this paper, we confirmed that noncontact real-time heartbeat and respiration detection using the doppler radar system has the possibility and limitation.

  • PDF

Application Development and Type Test for Smart Inverter Based on IEEE 1547-2018 Utilizing Power HILS (Power HILS를 활용한 IEEE 1547-2018 기반 스마트 인버터의 기술개발 및 형식시험 연구)

  • Shin, Danbi;Kang, Moses;Lee, Hyuna;Hong, Seonri;Yoon, Gihwan;Baek, Jongbok
    • Journal of IKEEE
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • In order to secure the reliability of the power system and to increase the penetration level of distributed energy resources (DERs), requirements such as IEEE 1547 have been revised to strengthen the grid connection standards for DER. This paper proposes a control scheme for smart inverter functions based on IEEE 1547-2018 that satisfy these standards, and introduces a power HILS-based test platform built for verification of smart inverter. Among the smart inverter functions, Volt-var and Frequency-watt allow the curve to be set from the upper level to comply with the interoperability and operation time of enable signals for each function are controlled by references from the upper level. According to the requirement, Volt-var and Frequency-watt are performed via power HILS platform and verified through the measurement results that all of the specified type tests were satisfied.