• Title/Summary/Keyword: 신생아 집중치료실

Search Result 114, Processing Time 0.033 seconds

The Effects of Music Interventions on High-risk Neonates in NICUs: Systematic Review and Meta-analysis (신생아집중치료실 고위험 신생아 대상 음악중재연구에 대한 체계적 문헌고찰 및 메타분석)

  • Kim, Hye Rang;Park, Hye Young
    • Journal of Music and Human Behavior
    • /
    • v.20 no.2
    • /
    • pp.115-142
    • /
    • 2023
  • The purpose of this study was to analyze and evaluate music intervention research conducted with high-risk neonates in NICUs in both domestic and international settings. Seventeen music intervention studies were identified, and their characteristics, including type of music, music provider, and treatment frequency, and outcomes (i.e., neonatal vital signs) were reviewed and analyzed along with meta-analysis. For music interventions targeting high-risk neonates in NICUs, the effect sizes of the neonates' vital signs were classified as either medium or large. In addition, larger effect sizes were associated with a combination of live and recorded music, nonmusical therapists as the music providers, and treatment frequency of one to five sessions per week. These research findings verify the clinical value of music for high-risk neonates and provide insights into the selection of music elements, music delivery methods, and music providers in NICU music interventions.

Clinical Usefulness of Point-of-care Test Chemistry Analyzer in Neonatal Intensive Care Unit

  • Jang, Yeong-Uk;Kim, Su-Nam;Cho, Hye-Jung;Sun, Yong-Han;Shim, So-Yeon;Son, Dong-Woo;Park, Pil-Whan
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.301-309
    • /
    • 2011
  • Purpose: Point-of-care tests (POCTs) have the potential to significantly influence management of neonates. The aim of this study was to assess the clinical usefulness of the POCT chemistry analyzer in a neonatal intensive care unit (NICU). Methods: Blood samples of neonates admitted to the NICU were tested using a POCT chemistry analyzer (Piccolo Xpress Chemistry Analyzer, Abaxis, Union City, CA, USA) and a central laboratory chemical analyzer (Chemistry analyzer 7600-110, Hitachi Ltd., Tokyo, Japan) from March to September, 2010. Correlation of 15 analytes between the POCT and the central laboratory machine was evaluated. For consistency of the POCT, three consecutive samplings were performed. Differences among the three tests were recorded. The causes of performance errors were checked through log files. Results: One hundred of 112 pairs of tests for accuracy performed in 54 neonates showed a high correlation between the two machines. Twelve performance errors occurred during the 112 tests. The most common error was insufficient sample error. Eighteen triplet tests performed in 18 patients for consistency revealed a difference range of 3-10%, which was considered to be acceptable. No error occurred during the 54 tests. Conclusion: The POCT is capable of analyzing multiple analytes with a minimal amount of whole blood in a short time. The few performance errors noted presently are likely preventable. This POCT is concluded to be suitable for use as a simple and rapid diagnostic method in the NICU with a minimal amount of blood collected in a less invasive manner.

Knowledge and Performance of Developmentally Supportive Positioning for Premature Infants among Neonatal Intensive Care Unit Nurses (신생아집중치료실 간호사의 미숙아 체위지지 간호에 대한 지식 및 수행)

  • Kim, Min-Jung;Kim, Tae-Im
    • Child Health Nursing Research
    • /
    • v.24 no.2
    • /
    • pp.229-240
    • /
    • 2018
  • Purpose: This study was conducted to assess the knowledge and performance of developmentally supportive positioning for premature infants (DSPP) among neonatal intensive care unit (NICU) nurses. Methods: The participants in this study were 131 nurses working in the NICU at five university hospitals in Daejeon and the city of Cheong-ju. The collected data were analyzed with descriptive statistics, the t-test, analysis of variance, and Pearson correlation coefficients using SPSS for Windows version 22.0. Results: NICU nurses' average DSPP knowledge score was 24.7 out of 33.0, and their average DSPP performance score was 3.2 out of 4.0. A statistically significant positive correlation was observed between knowledge and performance of DSPP (r=.32, p<.001). Conclusion: To improve the level of NICU nurses' knowledge and performance of DSPP, educational programs should be developed and their effectiveness should be verified.

Factors Affecting Turnover Intention of Nurses Working in Neonatal Intensive Care Units (신생아 집중치료실 간호사의 이직의도에 미치는 영향요인)

  • Jun, Sun Hwa;Lee, Mi Hyang;Shim, Moon Sook;Lim, Hyo Nam
    • Journal of Korean Clinical Nursing Research
    • /
    • v.27 no.1
    • /
    • pp.45-53
    • /
    • 2021
  • Purpose: This study was conducted to assess the factors affecting turnover intention of the nurses working in neonatal intensive care units, including the extent of fatigue, work stresses, and work overload related to infection control. Methods: This was a descriptive correlational study to test factors affecting the turnover intention of the nurses working in neonatal intensive care units. Data was analyzed utilizing descriptive statistics, t-test, One-way ANOVA, Pearsons' Correlation Coefficient, and multiple regressions by using the IBM SPSS Statistics 23.0 Program(IBM Corp., Armonk, NY). Results: The turnover intention of nurses had a positive correlation with the extent of fatigue (r=.54, p<.001), work stress (r=.40, p<.001), and with the work overload (r=.43, p<.001) related to infection control. In addition, factors affecting the turnover intention of nurses included the extent of fatigue (β=.52, p<.001) related to infection control and the number of pediatric patients assigned to each nurse (β=.26, p=.001) and the variances explained by the regression model was 37.0%. Conclusion: It is necessary to establish and implement strategies to lower the extent of fatigue related to infection control by reducing the nurses' workload. Securing additional nurses to ensure an appropriate number of pediatric patients assigned to each nurse, and providing efficient management and available resources to reduce the turnover intention of nurses working in neonatal intensive care units are suggested.

A Clinical Characteristics of Systemic Candidiasis in Neonatal Intensive Care Unit : Comparison with Systemic Bacterial Infection (신생아 집중치료실 입원아에 있어서 전신성 칸디다증의 임상적 특징 : 전신성 세균 감염증과 비교)

  • Lim, Jung Hwa;Park, Kyung Pil;Kim, Jin Kyung;Kim, Heng Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.7
    • /
    • pp.847-854
    • /
    • 2002
  • Purpose : Long term hospitalized infants in neonatal intensive care units(NICUs) are prone to systemic infection. It is important to differentiate systemic candidiasis from systemic bacterial infection early in the course. Thus, in this study, we have compared clinical characteristics of systemic candidiasis and systemic bacterial infection, in premature low birth weight infants. Methods : Retrospective chart review of the medical records of 20 patients with systemic candidiasis and 23 patients with systemic bacterial infection was performed. Results : Among the risk factors of systemic candidiasis, total parenteral nutrition(TPN), the use of broad spectrum antibiotics, central catheter insertion, endotracheal intubation and the use of H2 blockers were more frequent in neonates with systemic candidiasis than neonates with systemic bacterial infection. Apnea with bradycardia developed more frequently in neonates with systemic candidiasis compared with systemic bacterial infection(75% vs 39%). In laboratory findings at symptom onset, seven cases(35%) of systemic candidal infections and two cases(9%) of systemic bacterial infections showed leukopenia and thrombocytopenia(P=0.03). Blood was the most frequent isolation site of candida and bacteria. Conclusion : In neonates with systemic candidiasis, apnea with bradycardia, pneumonia and thrombocytopenia were prone to develop more frequently. The use of TPN, antibiotics and central catheters was strongly associated with systemic candidiasis. Empirical treatment with antifungal agent should be considered in critically ill neonates with above findings.

Outcomes and Management of Fetal Infants with Birth Weight Below 500 g at a Tertiary Center (출생체중 500 g 미만의 태아영아 치료성적 및 치료의 실제)

  • Chang, Yun Sil;Kim, Yu Jin;Koo, Soo Hyun;Lee, Jang Hoon;Hwang, Jong Hee;Choi, Chang Won;Shim, Jae Won;Kim, Sung Shin;Ko, Sun Young;Lee, Eun Kyung;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.9
    • /
    • pp.939-945
    • /
    • 2005
  • Purpose : The purpose of this study was to report outcome of fetal infants with birth weight below 500 g known as lower limit of viability and to evaluate treatment characteristics and short-term morbidity of their survivors. Methods : We retrospectively analyzed the medical records of all fetal infants with birth weight below 500 g who were delivered at Samsung Medical Center(SMC), or transferred to neonatal intensive care unit(NICU) of SMC within 24 hrs after birth between 1994 and 2004. Data for all interventions and morbidity outcome were analyzed for infants who were admitted to the NICU and were compared between NICU survivors and deaths. Results : Among 53 infants with birth weights of 400 to 499 g who were born in SMC during the study period, 8(15.1%) infants were admitted to the NICU and one was transferred to NICU from other hospital. Overall, 4(44%) of 9 survived and were discharged from the NICU. The smallest infant who survived weighed 439 grams. The least gestational age was $23^{+3}$ among the survivors. Compared with NICU deaths, NICU survivors had larger gestational age($24^{+2}{\pm}1^{+3}$ vs. $25^{+4}{\pm}2^{+3}$) and birth weight($424{\pm}17$ vs. $453{\pm}19$)(P<0.05). Median survival duration of NICU deaths was 15 days. None of NICU survivors had severe IVH, but 3(75%) had laser therapy for retinopathy of prematurity and bronchopulmonary dysplasia, respectively. Conclusion : Fetal infants with birth weight below 500 g known as lower limit of viability survived successfully. Study for their long-term follow-up will be needed to define our limit of viability and indication for their active resuscitation.

Ventilator-Associated Pneumonia in Neonatal Intensive Care Unit : Clinical Manifestations, Ddiagnostic Availability of Endotracheal Tip Culture (신생아 집중치료실에서 인공 환기요법 관련 폐렴의 임상양상과 기관내 삽관의 유용성에 관한 연구)

  • Kim, Nam Young;Sung, Tae Jung;Shin, Seon Hee;Kim, Sung Koo;Lee, Kon Hee;Yoon, Hae Sun
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.1
    • /
    • pp.67-74
    • /
    • 2005
  • Purpose : The incidence of mortality associated with respiratory difficulties is decreasing nowadays contributed to the development of neonatology. However, complications associated with mechanical ventilator are increasing. This study is to determine clinical manifestations, diagnositc availability of the endotracheal tip culture in patients with Ventilator-Associated Pneumonia(VAP) in neonatal intensive care unit(NICU). Methods : A retrospective analysis of 50 neonates who were admitted to the NICU of Kangnam Sacred Heart Hospital and had given mechanical ventilator from 1 January 2000 to 30 June 2003. VAP group defined as neonates who had pneumonia with mechanical ventilation longer than 48 hours. They were classified into VAP group(n=13) and control group (n=37) and the prevalence, microorganisms cultured from the endotracheal tube tip and risk factors were investigated. Results : The prevalence of VAP was 26.0%(n=13) and the most dominant microorganism cultured in our NICU was methicillin-resistant coagulase negative staphylococcus(MR-CNS) in 4 cases. Other microorganisms were Pseudomonas, Enterobacter, methicillin-resistant Staphylococcus aureus(MRSA) and Klebsiella. Gestational age, birth weight, Apgar score, respiratory distress syndrome, retinopathy of prematurity, bronchopulmonary dysplasia, sepsis, renal failure, pulmonary hemorrhage, pneumothorax were not different significantly between two groups except intraventricular hemorrhage(P<0.001) and patent ductus arteriosus(P<0.05). Duration of hospital stay and mortality rate were also not different significantly. Conclusion : VAP occurred at a significant rate among mechanically ventilated NICU patients. Despite of limitation of encotracheal tip culture, the most common microorganism was MR-CNS. We should be aware of occurrence of VAP in NICU neonate who were with mechanical ventilator and should treat with great care.

  • PDF

Neonatal Hearing Screening in Neonatal Intensive Care Unit Graduate (신생아 집중치료실 퇴원아의 신생아 청력 선별검사)

  • Cho, Sung-Hee;Kim, Han-A;Kim, El-Len A.;Chung, Jong-Woo;Lee, Byong-Sop;Kim, Ki-Soo;Pi, Soo-Young
    • Neonatal Medicine
    • /
    • v.16 no.2
    • /
    • pp.213-220
    • /
    • 2009
  • Purpose: Hearing loss is one of the common birth defects in humans, with a reported prevalence of 1-3 per 1000 newborns. We investigated the incidence of hearing loss and evaluated the use of neonatal hearing screening test in neonatal intensive care unit (NICU) graduates who are at greater risk for hearing loss than normal newborns. Methods: The neonates admitted to the NICU of Asan Medical Center from 1 March, 2003 to 30 March, 2008 who were available for follow-up were included. Those who failed the first auditory brainstem response prior to discharge were retested with the stapedial reflex test, auditory brainstem response and tympanometry in the Otolaryngology department. Results: Of 2,137 neonates, 2,000 (93.5%) neonates were tested prior to discharge. Sixty-seven neonates (3.4%) failed the first newborn hearing screening test. Of 67 infants, 52 infants were retested for a second hearing test. Excluding 10 infants (19.2%) who were lost during follow-up, 16 infants were confirmed to have hearing impairment of which 12 and 4 infants had unilateral and bilateral hearing loss, respectively. Of 16 infants, 5 did not meet the criteria set by the Korean National Health Insurance Corporation. Conclusion: The prevalence of hearing impairment in NICU graduates is about 0.8%, excluding those who were lost for follow up, necessitating a systemic and effective hearing assessment program among these high risk infants and more generous national insurance coverage.

Study on the neurodevelopmental predictors for the results of the Bayley Scales of Infant Development II in high-risk neonates (고위험 신생아에서 Bayley 발달 검사 결과에 영향을 미치는 신경발달 예후인자에 대한 연구)

  • Woo, Mi Kyeong;Kim, Dong Wook;Huh, Kyoung;Shim, Gyu Hong;Chey, Myoung Jae
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.11
    • /
    • pp.1221-1227
    • /
    • 2009
  • Purpose:To identify the risk factors for poor neurodevelopmental outcomes in high-risk neonates. Methods:We studied 94 infants admitted to the neonatal intensive care unit at the Sanggye Paik Hospital between January 2002 and November 2005 and evaluated the follow-up data. The following events were considered as risk factors: ${\leq}32$ weeks of gestation, very low birth weight, Apgar scores of less than 5, neonatal resuscitation, neonatal seizure, congenital infection, and abnormalities in cranial ultrasound or magnetic resonance imaging (MRI). The infants who had any one of these risk factors were included. They were evaluated at their mean corrected age of 13.84${\pm}$8.03 months. Mental and Psychomotor Developmental Indices (MDI, PDI) were determined by a clinical psychologist using the Bayley Scales of Infant Development II. Results:The mean MDI and PDI of all the patients were 96.28${\pm}$26.70 and 94.00${\pm}$22.80, respectively. Abnormalities on cranial ultrasound or MRI were significant predictors of both low MDI (P<0.05) and low PDI (P<0.001). These abnormalities showed a stronger association with low PDI than with low MDI. The infants with periventricular leukomalacia had the lowest MDI and PDI ($70.10{\pm}28.68$ and $69.70{\pm}24.91$, respectively). Apgar score at 1 minute and very low birth weight were also significant predictors for low PDI (P<0.05, P<0.05, respectively). Conclusion:Image findings with cranial ultrasound or MRI were the strongest predictors of neurodevelopmental outcome. Periventricular leukomalacia was the best predictive factor for mental and psychomotor development.

Noise Level and Frequency Experienced by Premature Infants Receiving Incubator Care in the Neonatal Intensive Care Unit (신생아집중치료실 내 인큐베이터 간호를 받는 미숙아가 경험하는 소음 수준 및 빈도)

  • Joo, So Hyun;Kim, Tae Im
    • Child Health Nursing Research
    • /
    • v.26 no.2
    • /
    • pp.296-308
    • /
    • 2020
  • Purpose: The purpose of this study was to identify the noise level and frequency experienced by premature infants receiving incubator care in the neonatal intensive care unit (NICU). Methods: The participants were 20 premature infants receiving incubator care in the NICU of a university hospital in Daejeon Metropolitan city. The noise level was measured using a professional sound-level meter (ET-958, FLUS, Shenzhen, China) based on a noise classification table developed by the author. The data were analyzed with descriptive statistics, the t-test, analysis of variance, and Pearson correlation coefficients using SPSS for Windows version 22.0. Results: The average noise level experienced by premature infants receiving incubator care in the NICU was 51.25 dB (range: 45.0~81.7 dB). The frequency of noises was highest for factors related to nursing activities (40.3%), followed by human factors (29.1%), machine alarm sounds (20.1%), incubator operation (6.6%), and internal environmental factors (3.9%). Conclusion: According to the above results, the noise level experienced by premature infants receiving incubator care in the NICU exceeded the recommendations of the American Academy of Pediatrics. Therefore, it is necessary to develop an interventional program to reduce noise in the NICU, and to conduct follow-up studies to verify its effectiveness.