• Title/Summary/Keyword: 신생아 집중치료실(신생아 중환자실)

Search Result 16, Processing Time 0.026 seconds

Analysis on the cause of eosinophilia in a neonatal intensive care unit (신생아 집중 치료실에서 호산구 증가증 원인에 관한 분석)

  • Kim, Jeong Young;Im, Hyo Bin;Sung, Min Jung;Son, Sang Hee;Seo, Son Sang
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.1
    • /
    • pp.28-32
    • /
    • 2010
  • Purpose : Although eosinophilia is a common laboratory finding in many neonatal intensive care units (ICUs), its causative mechanisms remain obscure. We aimed to determine the causes of eosinophilia in the neonatal ICU environment. Methods : Serial eosinophil counts were determined weekly for 288 hospitalized, appropriately grown neonates. Infants were divided into four groups according to gestational age, and the incidence and etiologic factors of eosinophilia were retrospectively studied. Results : Absolute eosinophilia (>$700/mm^3$) was documented in 18% (52/288) of neonates. Twenty-two infants (42.3%) exhibited mild eosinophilia ($700-999cells/mm^3$), 27 (51.9%) exhibited moderate eosinophilia ($1,000-2,999cells/mm^3$), and 3 (5.8%) exhibited severe eosinophilia (>$3,000cells/mm^3$). Of the 288 infants studied, 54 suffered sepsis. Thirty of these 54 infants (55.6%) showed eosinophilia, and 22 out of the remaining 234 infants (9%) without sepsis showed eosinophilia, indicating that eosinophilia was more prevalent in the sepsis group (P <0.05). All 5 infants suffering from bronchopulmonary dysplasia showed eosinophilia, and 47 out of the remaining 283 infants (16.7%) without bronchopulmonary dysplasia showed eosinophilia. Thus, eosinophilia was more prevalent in the bronchopulmonary dysplasia group (P<0.05). Furthermore, increased prevalence of eosinophilia was associated with respiratory distress syndrome, ventilator use, blood transfusion, and total parenteral nutrition (P<0.05). Conclusion : Our results suggest that eosinophilia is influenced by sepsis and bronchopulmonary dysplasia, although it can also occur idiopathically at birth. Moreover, the potential role of eosinophils in conditions such as wound healing and fibrosis in sepsis or chronic lung disease may be a cause of eosinophilia.

Systemic Candida Infection in Very Low Birth Weight Infants : Epidemiological Features Over 5 Years (극소 저체중 출생아에서 전신성 칸디다 감염 : 5년간의 역학적 특성)

  • Lee, Seung-Woo;Lee, Jeong-Eun;Lee, Ju-Young;Lee, Hyun-Seung;Lee, Jung-Hyun;Sung, In-Kyung
    • Neonatal Medicine
    • /
    • v.16 no.2
    • /
    • pp.190-196
    • /
    • 2009
  • Purpose: Candida infection has increased in neonatal intensive care units (NICU). However, recent reports on systemic candida infections in preterm newborns are rare in Korea. The aim of this study was to examine the epidemiological features of systemic candida infection in very low birth weight infants (VLBW) over the past five years. Methods: We retrospectively reviewed the medical records of 19 patients with systemic candida infections in VLBW that were admitted to the neonatal intensive care units of three hospitals affiliated with the College of Medicine, The Catholic University of Korea from January 2004 to December 2008. We analyzed the birth weight, gestational age, age at diagnosis, risk factors, co-morbidity, antifungal treatment, and mortality rates among the 19 patients. Results: Systemic candida infections occurred in 19 cases (4.7%) among the VLBW infants. The mean birth weight and gestational age were 959.0$\pm$255.9 g and 26.7$\pm$2.1 weeks. The isolated Candida species were C. albicans (4), C. parapsilosis (9), C. glabrata (2), C. famata (2), and unkown subspecies (2). Most patients had various associated risk factors, including a central venous catheter, broad spectrum antibiotics, parenteral nutrition, intravenous lipid emulsion, endotracheal intubation and $H_2$ blocker therapy. There was no significant difference in the risk factors between newborns that survived and those that died with regard to the systemic candida infection, except for gestational age. Nine (47.4%) out of 19 patients with a candida infection died and four cases (21.2%) were directly related to the candida infection. Conclusion: The prevalence of systemic candida infection is increasing in VLBW infants. The majority of Candida species has shifted to C. non-albicans, especially C. parapsilosis. Because of the high mortality associated with candida infection in the NICU, prophylaxis and early treatment based on epidemiological features is necessary.

Comparison of Outcomes According to the Hospitals of Antenatal Care in Very Low Birth Weight Infants (극소 저체중 출생아에서 산전 관리 기관에 따른 임상 경과 및 예후 비교)

  • Lee, Byoung-Kook;Lee, Heun-Ji;Min, Sung-Joo;Kim, Do-Hyun;Kim, Hee-Sup
    • Neonatal Medicine
    • /
    • v.16 no.2
    • /
    • pp.205-212
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the differences according to the hospitals of antenatal care in premature infants. Methods: We retrospectively reviewed the medical records of premature infants with gestational ages <37 weeks and very low birth weights who were admitted immediately after birth to the neonatal intensive care unit (NICU) at the Dongguk University Ilsan Hospital between March 2007 and February 2009. The hospitals of antenatal care were divided into two levels (primary antenatal care hospital: hospitals with less than a level 2 NICU, secondary antenatal care hospital: hospitals with a level 3 NICU) based on the level of NICU in hospitals. In addition, total infants were divided into two groups (Immediate group: infants born within 24 hours of maternal admission, Delayed group: infants born after 24 hours of maternal admission). The differences between maternal and neonatal variables in each groups were studied. Results: Neonates in secondary antenatal care hospitals comprised 11.0% of the study neonates (10 of 91). We compared with two groups (primary antenatal care hospital and secondary antenatal care hospital), but there were no differences in all subjects. However, the 1 minute Apgar score ($\leq3$) was lower in the immediate group than the delayed group. Conclusion: Shorter duration of maternal admission to delivery was associated with a lower 1 minute Apgar score of neonates. These findings suggest that if maintenance of pregnancy is difficult when high-risk gravidas are transferred, clinicians must prepare for emergencies of neonates.

Risk Factors for Hearing Loss in Very Low Birth Weight Infants: Results of Hearing Test in Infants <1,500 g (극소 저체중 출생아에서 청력 손상에 영향을 미치는 요인: 1,500 g미만의 청력 검사 결과)

  • Sung, Min-Jung;Han, Young-Mi;Park, Kyung-Hee;Lee, Il-Woo;Byun, Shin-Yun
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.328-336
    • /
    • 2011
  • Purpose: An association between very low birth weight infants(VLBWI) and hearing loss has long been recognized. Early identification and intervention for hearing loss benefits language and speech/cognitive development. We investigated the risk factors and clinical outcomes of hearing loss among VLBWI. Methods: We analyzed the results of auditory brainstem response (ABR) testing of VLBWI. These infants were admitted to the neonatal intensive care unit (NICU) of Pusan National University Yangsan Hospital between December 2008 and February 2011. A follow-up was conducted subsequently. Results: ABR evaluations were performed on 65 infants, and 31 showed abnormal results (47.7%). Among the 31 infants, 10 were classified with moderate/severe/profound hearing loss (15.4%). The infants with abnormal ABR had a higher incidence of low birth weight, prolonged ventilator care, cumulative dose of furosemide, and the lowest $PaO_2$ (P<0.05). Those with moderate/severe/profound hearing loss had a higher incidence of low Apgar scores at 5 minutes (odds ratio[OR],0.34; 95% confidence interval[CI],0.13-0.89), prolonged ventilator care (OR,1.06; 95% CI,1.01-1.12), and mild hearing loss compared to those without profound hearing loss. Follow-up evaluations on eight infants with ABR reveled improvements 5.6${\pm}$3.9 months later. One infant, who had profound hearing loss in both ears, used a hearing aid. Conclusion: Factors influencing hearing loss at the first VLBWI hearing screening test included lower Apgar scores at 5 min and prolonged use of a ventilator. Most VLBWI with hearing losses were expected to recover after several months of follow-up.

Comparison of the Clinical Performance between Two Pulse Oximeters in NICU: Nellcor $N-595^{(R)}$ versus Masimo $SET^{(R)}$ (신생아 중환자실에서 맥박산소측정기의 감지도 비교: Nellcor $N-595^{(R)}$ versus Masimo $SET^{(R)}$)

  • Lee, Heun-Ji;Choi, Jang-Hwan;Min, Sung-Ju;Kim, Do-Hyun;Kim, Hee-Sup
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.245-249
    • /
    • 2010
  • Purpose: Numerous false alarms by pulse oximetry, which is widely used in neonatal intensive care unit, can delay response to true alarms. Masimo $SET^{(R)}$ was introduced lately, to overcome false alarms by motion. We compared the clinical performance of two devices (Nellcor $N-595^{(R)}$ and Masimo $SET^{(R)}$) for the evaluation of the false alarm frequency during usual motion artifacts and stable state. Methods: A total of 20 preterm infants weighing 1,000-2,500 g were enrolled in the study. The sensors of two devices were placed on the different feet on the same infants, and both devices were programmed to emit an alarm for episode of hypoxemia (SpO2$\leq$85%). The false alarms were defined as episodes of poor correlation with ECG heart rate, poor waveforms, and the absence of obvious signs of hypoxia. We compared the frequency of false alarms between the two devices. Results: The mean chronological age was 20.8 days and the mean body weight was 1,668 g on the study day. The frequency of total false alarm was significantly fewer for Masimo $SET^{(R)}$ pulse oximetry (48 in Nellcor $N-595^{(R)}$, 27 in Masimo $SET^{(R)}$) although the false alarm during usual motion artifacts was not significantly between two devices (32 in Nellcor $N-595^{(R)}$, 19 in Masimo $SET^{(R)}$). Conclusion: The Masimo $SET^{(R)}$ pulse oximetry has fewer false alarm rates and identified more true hypoxic events than Nellcor $N-595^{(R)}$ pulse oximetry. Therefore, it is useful for adequate oxygen therapy and helps to decrease unnecessary handling by clinicians and nurses.

Effect of prophylactic indomethacin in extremely low birth weight infants (초극소 저출생체중아에서 예방적 indomethacin 투여효과)

  • Lee, Bo Lyun;Kim, Su Jin;Koo, Soo Hyun;Jeon, Ga Won;Chang, Yun Sil;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.9
    • /
    • pp.959-965
    • /
    • 2006
  • Purpose : The purpose of this study was to investigate the effect of prophylactic indomethacin on reduction of patent ductus arteriosus(PDA) and intraventricular hemorrhage(IVH) in extremely low birth weight infants(ELBWI). Methods : Retrospective review of 84 ELBWI who were admitted to our neonatal intensive care unit from June 2004 to April 2006 was performed. Patients were divided into prophylactic group(n=28) and control group(n=56), where prophylactic indomethacin were given within 6 hours after birth. Clinical outcomes were compared between these groups. Results : There were no significant differences in gestational age, birth weight, incidence of hemodynamically significant PDA and severe IVH, and mortality between prophylactic group and control group. However, there were more frequent indications for therapeutic indomethacin, higher incidence of intestinal perforation, and longer time to achieve full enteral feeding in prophylactic group than control group. The incidence of other adverse events attributed to indomethacin prophylaxis did not differ between two groups. Conclusions : Prophylactic indomethacin may not prevent hemodynamically significant PDA and severe IVH in ELBWI. On the contrary, it may be associated with increased risk of adverse events. Further efforts should be investigated to decrease PDA and severe IVH in ELBWI.