• Title/Summary/Keyword: 신뢰성 Simulator

Search Result 172, Processing Time 0.033 seconds

A study on Software Maintenance of Domestic Weapon System by using the Automatic Test Equipment

  • Chae, Il-Kwon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.1
    • /
    • pp.51-59
    • /
    • 2022
  • As the weapon system's dependence on software functions increased, software became a key factor in controlling the weapon system. In addition, as software development becomes more important domestically and internationally, software verification becomes an issue. The recent defense market has recognized this point and is demanding a plan for weapon system software maintenance. In this paper, we propose a weapon system software maintenance plan using Automatic Test Equipment. The specific method is to use a simulator to check the software function and identify failure cases. This is an effective way for developers to reduce the Total Corrective Maintenance Time(TCM) of the weapon system by reducing the time it takes to identify failure cases. It has been proven that the proposed Automatic Test Equipment can achieve software maintenance and excellent Maintainability and Operational Availability compared to the existing ones.

Revision of the Input Parameters for the Prediction Models of Smoke Detectors Based on the FDS (FDS 기반의 연기감지기 예측모델을 위한 입력인자 재검토)

  • Jang, Hyo-Yeon;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.44-51
    • /
    • 2017
  • Accurate predictions of the activation time for smoke detectors using a fire simulation is are required to ensure the reliability of the RSET (Required Safe Egress Time) calculation in the process of PBD (Performance-Based Design). The objective of this study was to enhance the accuracy of input parameters for the numerical models of smoke detector based on the FDS. To this end, a Fire Detector Evaluator (FDE) developed in previous studies was improved. The uniformities of flow and smoke inside the FDE were improved and accurate measurements of the obscuration per meter (OPM) related to detector operation were also performed through a decrease in the forward scattering of smoke particles. The input parameters using the improved FDE showed a significant difference from the previous FDE quantitatively. In particular, a larger difference was found in a photoelectric detector compared to an ionization detector. Considering that the operating conditions of smoke detectors are affected by the detector type, combustibles, smoke particulars, and color, the database (DB) on the input parameters for various detectors and combustibles should be built to improve the reliability of PBD in future studies.

Performance Evaluation for IEEE 802.15.4 Based Telematics Transportation Safety System (IEEE 802.15.4 기반 텔레매틱스 교통안전시스템 성능 평가)

  • Kim, Young-Man;Eom, Doo-Seop;Kim, Min-Soo;Kim, Hwan-Sik
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.11a
    • /
    • pp.1303-1306
    • /
    • 2005
  • 최근 차량에 설치된 단말기를 통해 길안내 서비스, 교통정보 서비스 등 다양한 정보를 제공하는 텔레매틱스 서비스가 활발하게 연구되고 있다. 하지만 현재 대다수의 텔레매틱스 서비스는 최대 15m의 공간 오차를 가진 GPS 기술을 이용하기 때문에 차량의 정확한 위치정보를 파악하기는 힘들다. 따라서 본 연구에서는 무선 센서 노드를 이용해 GPS보다 정확한 차량의 위치정보와 속도를 감지해 교차로에서 발생할 수 있는 차량 충돌을 예측하고 충돌 위험 정보를 교차로에 근접한 자동차에게 알려주는 텔레매틱스 교통안전시스템을 구성하고 노드 간 통신 프로토콜로서 IEEE 802.15.4[1]를 채택한 후 고정 라우팅 방식으로 차량정보를 베이스 스테이션까지 보내어 교차로 주변차량 전체에 브로드캐스트하는 방식을 취하도록 한다. 빠르게 이동하는 차량의 특성상 교차로 차량 충돌 방지 서비스 구현에 있어서 높은 실시간성과 신뢰성을 갖춘 프로토콜이 요구된다. 따라서 본 차량 충돌 예측을 위한 교통안전시스템의 신뢰성과 실시간성을 평가하기 위하여 Network Simulator 2 (NS/2)[2]를 이용하여 시뮬레이션 한다.

  • PDF

Measurement of the Device Properties of a Ionization Smoke Detector to Improve Predictive Performance of the Fire Modeling (화재모델링 예측성능 개선을 위한 이온화식 연기감지기의 장치물성 측정)

  • Kim, Kyung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.27-34
    • /
    • 2013
  • The high prediction performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of PBD (Performance Based fire safety Design). The main objective of the present study is to measure input information in order to predict the accurate activation time of smoke detector into a Large Eddy Simulation (LES) fire model such as FDS (Fire Dynamics Simulator). To end this, FDE (Fire Detector Evaluator) which can measure the device properties of detector was developed, and the input information of Heskestad and Cleary's models was measured for a ionization smoke detector. In addition, the activation times of smoke detectors predicted using default values into FDS and measured values in the present study were systematically compared. As a result, the device properties of smoke detector examined in the present study showed a significant difference compared to the default values used into FDS, which resulted in the considerable difference of up to 15 minutes or more in terms of the activation time of smoke detector. The database (DB) on device properties of various smoke and heat detectors will be built to improve the reliability of PBD in future studies.

Reliability of a Cobalt Silicide on Counter Electrodes for Dye Sensitized Solar Cells (코발트실리사이드를 이용한 염료감응형 태양전지 상대전극의 신뢰성 평가)

  • Kim, Kwangbae;Park, Taeyeul;Song, Ohsung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.1-7
    • /
    • 2017
  • Cobalt silicide was used as a counter electrode in order to confirm its reliability in dye-sensitized solar cell (DSSC) devices. 100 nm-Co/300 nm-Si/quartz was formed by an evaporator and cobalt silicide was formed by vacuum heat treatment at $700^{\circ}C$ for 60 min to form approximately 350 nm-CoSi. This process was followed by etching in $80^{\circ}C$-30% $H_2SO_4$ to remove the cobalt residue on the cobalt silicide surface. Also, for the comparison against Pt, we prepared a 100 nm-Pt/glass counter electrode. Cobalt silicide was used for the counter electrode in order to confirm its reliability in DSSC devices and maintained for 0, 168, 336, 504, 672, and 840 hours at $80^{\circ}C$. The photovoltaic properties of the DSSCs employing cobalt silicide were confirmed by using a simulator and potentiostat. Cyclic-voltammetry, field emission scanning electron microscopy, focused ion beam scanning electron microscopy, and energy dispersive spectrometry analyses were used to confirm the catalytic activity, microstructure, and composition, respectively. The energy conversion efficiency (ECE) as a function of time and ECE of the DSSC with Pt and CoSi counter electrodes were maintained for 504 hours. However, after 672 hours, the ECEs decreased to a half of their initial values. The results of the catalytic activity analysis showed that the catalytic activities of the Pt and CoSi counter electrodes decreased to 64% and 57% of their initial values, respectively(after 840 hours). The microstructure analysis showed that the CoSi layer improved the durability in the electrolyte, but because the stress concentrates on the contact surface between the lower quartz substrate and the CoSi layer, cracks are formed locally and flaking occurs. Thus, deterioration occurs due to the residual stress built up during the silicidation of the CoSi counter electrode, so it is necessary to take measures against these residual stresses, in order to ensure the reliability of the electrode.

Local Recovery in Reliable Multicast Protocols by Separating NAK-suppression from Error Recovery Request (신뢰성 있는 멀티캐스트 프로토콜에서 NAK 메시지의 기능 분리를 통한 지역적 오류 복구)

  • Jung, Choong-Il;Lee, Yun-Hee;Park, Chang-Yun
    • Journal of KIISE:Information Networking
    • /
    • v.28 no.4
    • /
    • pp.559-569
    • /
    • 2001
  • With the growth of the Internet, applications using the reliable multicast protocol are increasing. Two important requirements of reliable multicasting are reliability and scalability. To enhance scalability, many methods have been proposed. A typical method is a local recovery scheme. This paper proposes a new stable and effective protocol with the following features. The first is to apply the discipline of the separations of concerns to NAK message. By dividing the functions of the NAK message into the error recovery request and the NAK-suppression, each function can be optimized. Second, a local representative, which is selected gradually and distributively, executes error recovery in somewhat deterministic manner. Finally, by dynamically adjusting the TTL value of the control message, the error recovery domain can be optimized. The proposed scheme has been implemented and experimented on Network Simulator. Compared to the existing schemes, the performance results show that scalability has not only been enhanced but also error recovery time and network overhead have been reduced.

  • PDF

The Analysis of Fire-Driven Flow and Temperature in The Railway Tunnel with Ventilation (환기를 동반한 철도터널 화재 연기유속 및 온도장 해석)

  • Jang, Yong-Jun;Lee, Chang-Hyun;Kim, Hag-Beom;Lee, Woo-Dong
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1794-1801
    • /
    • 2008
  • Fire-driven flow and temperature distribution in a ventilated tunnel was analyzed by Large Eddy Simulation using FDS code. The simulated tunnel is 182m length, 5.4m wide and 2.4m height. A pool fire was located 112m from tunnel entrance and was taken as a heat source of $0.89m^2$. The heat is assumed to be released uniformly throughout the whole simulated time. The fire strength was 2.76MW and the fuel burnt was octane. The parallel computational method was employed to accelerate the computing time and manage the large grid points which is not possible to handle in the one CPU. The total grid points used were $2.4{\times}10^6$ and 7 CPUs were used to calculate the momentum and energy equations. The simulated results were well compared with the experiments.

  • PDF

The Design of Mobile Grid Architecture using Ad-Hoc Network (Ad-Hoc 네트워크를 이용한 모바일 그리드의 구조 설계)

  • Kim Tea-Kyoung;Seo Hee-Sek;Kim Hee-Wan
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.2
    • /
    • pp.345-354
    • /
    • 2005
  • Mobile grid can provide the grid service to grid users regardless of space and time. There are many restrictions to use grid service in mobile environment such as battery power of mobile device, movement pattern of mobile device etc. So it is difficult to apply the grid technologies of wired network to wireless network environments. Therefore, to provide the mobile grid service, we suggested the mobile grid architecture using ad-hoc network. Also we showed that hybrid routing protocol is efficient for mobile grid service by considering the battery power of mobile device and simulations of evaluating the delay time of three routing protocols using NS-2. We will study the methods of resource allocations and network reliability to provide the mobile grid service.

  • PDF

A review of test method the Double-system Track side Functional Modules in High speed line (고속선로변 2중화 정보처리모듈 시험방안 고찰)

  • Chang, Seok-Gahk;Back, Seung-Koo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.603-609
    • /
    • 2008
  • Nowadays, double-system of TFM(Track-side Functional Modules) developed instead of single-system in use of high speed line to acquisition more availability. Safety Law for Railroad recommend to quality certification of development and general railway machines. It is important to select metrics which form the bases for testing software products. A number of package software development part do not open source cords, so testing external characteristic vectors having relationship with metrics. In this paper, review the process for the TFM Point Modules, Universal Modules and Switchers, think about the test methode of circuit boards output performance by using TFM tester and Simulators.

  • PDF

DTN Routing for Improving Transmission Efficiency in a Destroyed Environment of Communication Infrastructure (통신 인프라가 파괴된 환경에서 전송 효율 향상을 위한 DTN 라우팅)

  • Jang, Sung-Jin;Lee, Won-Hui
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.37-41
    • /
    • 2020
  • In this paper, we propose a routing method to improve the message transmission efficiency between DTN nodes in an environment where communication infrastructure in the city is destroyed. In the situation where a certain size of communication infrastructure can not function, the message transmission process between the nodes is explained. An effective routing method for improving reliability between nodes was proposed and evaluated using DTN simulator. The routing algorithm with improved reliability in urban areas was confirmed by simulation considering the message transmission relationship between nodes on uncertain path due to the destruction of communication infrastructure. We used a routing algorithm that includes all the contact information the node has experienced in the past. In the simulation of delivering messages in a situation where the communication infrastructure was destroyed, relatively better results were obtained than the existing routing algorithm.