• Title/Summary/Keyword: 신뢰성 Simulator

Search Result 172, Processing Time 0.022 seconds

Development of 60MW HVDC System Control Algorithm (60MW급 HVDC 시스템 제어 알고리즘 개발)

  • Lee, Kyung-Bin;Chung, Yong-Ho;Hwang, Ho-Yoon
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.183-184
    • /
    • 2012
  • 2010년부터 민간기업인 LS산전과 한국전력공사의 공동 개발을 통하여 60MW급 ${\pm}80kV$ HVDC (High Voltage DC transmission System)전류형 HVDC시스템 알고리즘 국산화 개발을 진행하여 2012년 3월 개발을 완료하였다. 개발된 알고리즘의 성능, 안정성 및 신뢰성을 확보하기 위하여 LS산전에서 개발한 Hardware 플랫폼에 제어 알고리즘을 탑재하고 RTDS(Real Time Digital Simulator)를 통한 연계시험을 진행하여 이를 검증하였다. 본 논문에서는 개발된 HVDC 제어 알고리즘의 기능과 RTDS연계 시험결과를 소개하고자 한다.

  • PDF

Development of Interlocking Signal Simulator for Verification of Naval Warship Engineering Control Logics (함정 통합기관제어체계의 제어로직 검증을 위한 연동신호 시뮬레이터 개발)

  • Lee, Hunseok;Son, Nayoung;Shim, Jaesoon;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.8
    • /
    • pp.1103-1109
    • /
    • 2021
  • ECS is a control device so that the warship can perform the mission stably by controlling and monitoring the entire propulsion system. As the recent provisions of the warship, it's propelling system is complicated than past, as the demand performance and mission of the warships are diverse. In accordance with the complicated propulsion system configuration, the demand for automatic control function of the ECS is increasing for convenient and stable propulsion system control for convenient and stable. As a result, verification of ECS stability and reliability is required. In this paper, we develop an interlocking signal simulator for verifying ECS control logic and communication protocol for warship with CODLOG propulsion systems. The simulator developed was implemented to simulate a signal of gas turbine, propulsion motors, diesel generator and 11 kinds of auxiliary equipment. The reliability of ECS was verified through the ECS communication program and the I/O signal static test with the simulator.

A development of multisite hourly rainfall simulation technique based on neyman-scott rectangular pulse model (Neyman-Scott Rectangular Pulse 모형 기반의 다지점 강수모의 기법 개발)

  • Moon, Jangwon;Kim, Janggyeong;Moon, Youngil;Kwon, Hyunhan
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.11
    • /
    • pp.913-922
    • /
    • 2016
  • A long-term precipitation record is typically required for establishing the reliable water resources plan in the watershed. However, the observations in the hourly precipitation data are not always consistent and there are missing values within the time series. This study aims to develop a hourly rainfall simulator for extending rainfall data, based on the well-known Neyman-Scott Rectangular Pulse Model (NSRPM). Moreover, this study further suggests a multisite hourly rainfall simulator to better reproduce areal rainfalls for the watershed. The proposed model was validated with a network of five weather stations in the Uee-stream watershed in Seoul. The proposed model appeared a reasonable result in terms of reproducing most of the statistics (i.e. mean, variance and lag-1 autocovariance) of the rainfall time series at various aggregation levels and the spatial coherence over the weather stations.

Selective Unacknowledged Transmission in IEEE 802.15.4 Considering Energy Efficiency (IEEE 802.15.4에서 에너지 효율성을 고려한 선택적 Unacknowledged 전송)

  • Yang, Hyun;Park, Tan-Se;Park, Chang-Yun;Jung, Chung-Il
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.6
    • /
    • pp.717-721
    • /
    • 2010
  • In general, wireless MAC uses the ACK for reliability. Meanwhile, in wireless sensor network, data is delivered periodically and redundantly. In these situations, every ACK transmission causes the reliability flexible applications to waste some energy. IEEE 802.15.4 developed for energy efficiency has the option of using ACK or not, but there are no researches exploiting this peculiarity. In this paper, we proposed the selective unacknowledged transmission satisfying some requirements (e.g., end-to-end delivery) by removing the ACK when frames are delivered well and using the ACK when frames are delivered poorly. Also, we performed several evaluations exploiting the NS2 simulator.

A Fault Simulator for IDDQ Testing (IDDQ 테스트를 위한 고장 시뮬레이터)

  • 배성환;김대익;이창기;전병실
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.92-96
    • /
    • 1999
  • As CMOS technologies have been rapidly developed, bridging faults have been relatively increased. IDDQ testing is a current testing methodology which can enhance reliability of the circuit since it efficiently detects bridging faults that are difficult to detect by functional testing. In this paper we consider internal bridging faults occurred in each gate of logic circuits under test and finally develop a fault simulator for IDDQ testing to detect assumed bridging faults.

  • PDF

A Study on Probing based Multicasting Admission Control Mechanism for IP Multimedia Service (IP 멀티미디어 서비스를 위한 Probing 기반 멀티캐스팅 수락 제어 메커니즘 연구)

  • Rhee, Woo-Seop;Yoo, Whan-Seok;Lee, Soon-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.10B
    • /
    • pp.613-620
    • /
    • 2007
  • Recently, due to the developing of broadband convergence networks, the high quality multimedia services which are converged with communication and broadcasting can be provided. These high quality communication and broadcasting convergence service needs reliable multicasting mechanism in IP networks. However, multicasting mechanism recently deployed is difficult to guarantee the end-to-end QoS. For the reliable high quality If multimedia IPTV service, the QoS guaranteed multicasting mechanism should be provided. Therefore, we proposed a probing packet based multicasting admission control mechanism using centralized multicasting control management block in this paper. And for the performance evaluation of the proposed mechanism, we used ns-2 simulator.

Development of 4MW Class High Voltage Inverter System (4MW급 고압 인버터 시스템 개발)

  • 박영민;한기준;최세경;정명길;이세현
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.432-437
    • /
    • 2001
  • This paper describes a new developed 3.3KV/4MW class three-level Voltage Source Inverter(VSI), which is equipped with IIMS(Inverter Information Management System) based on the world wide web and with the Virtual operation simulator. The algorithm for motor control is the stator oriented Direct Torque Control(DTC), which works without speed sensor and gives the physically fastest dynamic response. The IIMS have the functions of operation monitoring and data managements. Virtual operation simulator can analyze and tune the system characteristics without main power. Now, this system is under the field test to verify the confidence.

  • PDF

Development of Naval Ship Propulsion System Simulator for CODLOG based ECS Verification (CODLOG 기반 ECS 검증용 함정 추진 시뮬레이터 개발)

  • Jang, Jae-hee;Kim, Dong-jin;Kim, Min-gon;Oh, Jin-seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.9
    • /
    • pp.1796-1807
    • /
    • 2017
  • The domestic warship propulsion system is at the stage of a hybrid propulsion system changing from a mechanical propulsion system and the propulsion system becomes complicated so it is expected that the function of ECS(Engineering Control System) that controls and monitors the warship propulsion system becomes important. Recently the development of ECS has progressed domestically, so that verification of reliability and stability is required in the process of ECS development. The simulator to be proposed is composed of HILS, it can be divided into a shaft-line dynamics model of the simulating power transmission, a controller model of the simulating the control of the equipment, and a communication model communicating with the ECS. In this paper, we developed simulator for ECS verification for CODLOG hybrid propulsion system, set scenario, and conducted simulation.

Development of a PCS Simulator and Data Storage System for Energy Saving in the Ship (선박 에너지 절감을 위한 PCS 시뮬레이터 및 데이터 저장 시스템 개발)

  • Oh, Jin-Seok;Kang, Young-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.2189-2196
    • /
    • 2015
  • According to increase environmental pollutions and fuel costs, The study of energy saving in the ship is proceeding actively. PCS is pump control system for cooling system in the ship to improve the energy efficiency by controling rotation speed of sea water pump, fresh water pump and position of 3way valve. In this paper, we develop the PCS simulator that has an environment similar to the cooling system of the actual vessel to ensure reliability of the PCS. Also, PC-based control and data storage system for PCS simulator is developed. To develop this system, National Instrument's cDAQ and LabVIEW are used. Finally, confirm the behavior of the simulator by analyzing the saving data.

DB Construction of Activation Temperature and Response Time Index for Domestic Fixed-temperature Heat Detectors in Ceiling Jet Flow (천장제트기류에 대한 국내 정온식 열감지기의 작동온도 및 반응시간지수(RTI)에 관한 DB 구축)

  • Yoon, Ga-Yeong;Han, Ho-Sik;Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.35-42
    • /
    • 2020
  • The accurate prediction of fire detector activation time is required to ensure the reliability of fire modeling during the safety assessment of performance-based fire safety design. The main objective of this study is to determine the activation temperature and the response time index (RTI) of a fixed heat detector, which are the main input factors of a fixed-temperature heat detector applied to the fire dynamics simulator (FDS), a typical fire model. Therefore, a fire detector evaluator, which is a fire detector experimental apparatus, was applied, and 10 types of domestic fixed-temperature heat detectors were selected through a product recognition survey. It was found that there were significant differences in the activation temperature and RTI among the detectors. Additionally, the detector activation time of the FDS with the measured DB can be predicted more accurately. Finally, the DB of the activation temperature and RTI of the fixed-temperature heat detectors with reliability was provided.