• Title/Summary/Keyword: 시험편두께

Search Result 99, Processing Time 0.023 seconds

The Effect of Specimen Thickness on the Fatigue Crack Propagation Rate (피로크랙전파율에 대한 시험편 두께의 영향)

  • Koh, Sung-Wi;Um, Yoon-Sung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.1
    • /
    • pp.44-49
    • /
    • 1988
  • The paper presents the preliminary results of an esperimental study on crack growth under tension-tension fatigue loading. A purpose of the study is to find the effect of the specimen thickness on crack propagation behaviors. The thickness of the low catbon steel specimens the are used in the experiments are 5, 10, 15,20, and 25 mm. the type of specimen considering in the present study is compact tension specimen.Crack growth behaviors are obseved and measured by travelling microscope. From the study, the followings are found; 1. There is a certain specimen thickness that is the shortest farigue life. The fatigue life of 15mm specimen is the shorter then that of any other opecimen 2. The crack initiation of the thick specimen is slower than that of thin specimen. But the crack propagation rate is just the opposite. 3. The range which is the exponent, m of power law(paris) is 1.98-4.59. the thicker the spec-imen is, the higher the value of m is.

  • PDF

Simultaneous Measurement of Ultrasonic Velocity and Thickness of Isotropic and Homogeneous Solids Using Two Transducers (두개의 탐촉자를 사용한 등방성 균일 고체의 초음파 속도 및 두께 동시 측정법)

  • Lee, Jeong-Ki;Kwon, Jin-O;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.363-368
    • /
    • 1999
  • Ultrasonic pulse-echo methods measuring the transit time through specimens have been widely used in determination of ultrasonic velocity and thickness of specimens. Usually, to determine the velocity of the ultrasonic. the transit time of the ultrasonic pulse through specimen is measured by using the ultrasonic measuring equipment such as the oscilloscope including ultrasonic pulser/receiver and the thickness of the specimen is measured by using the length measuring instrument such as micrometer or vernier calipers etc., i. e. each parameter is measured by using each measuring method. In the case of the measuring the thickness of a specimen by using the ultrasonics. the ultrasonic equipments, which measure the thickness, such as the ultrasonic thickness gauge must be calibrated by using the reference block of which the ultrasonic velocity is known beforehand. In the present work, we proposed a new method for simultaneous measurement of ultrasonic velocity and thickness without reference blocks. Experimental results for several specimens show that proposed method have good agreements with those by traditional ultrasonic method.

  • PDF

A Fracture Study on the Bonded DCB Specimen of the Mode III Type with Aluminum Foam (알루미늄 폼으로 된 Mode III 형의 접합된 DCB 시험편에 대한 파괴 연구)

  • Lee, Jung-Ho;Cho, Jae-Ung;Cheon, Seong-Sik
    • Composites Research
    • /
    • v.28 no.4
    • /
    • pp.191-196
    • /
    • 2015
  • In this study, the static analysis and experiment were carried out on DCB specimens manufactured with aluminum foam in order to investigate the fracture toughness at the adhesive joint of the structure bonded with adhesive. In case of static analysis, all specimen models were shown to have the maximum reaction force when the forced displacement proceeded as much as 5 mm. The maximum reaction forces became 0.25 kN, 0.28 kN and 0.5 kN respectively in cases of specimen thicknesses of 35 mm, 45 mm and 55 mm. Two specimens in case of static experiment were selected to verify these analysis results. The maximum reaction forces were shown when the forced displacement proceeded as much as 5 to 6 mm. The maximum reaction forces became 0.22 kN and 0.3 kN respectively in cases of specimen thicknesses of 35 mm and 45 mm. By comparing the derived results, it could be shown that there was not much difference between the data of analyses and experiments. Therefore, It is inferred that the study data can be secured with only analysis by no extra experimental procedure. It is thought that the mechanical properties at the structure bonded of DCB with the type of mode III can be analyzed systematically.

A Study of Eddy Current Test for fin Tube in Different Fin Height (Fin 높이가 다른 Fin Tube의 와전류탐상에 관한 연구)

  • 이동진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.118-124
    • /
    • 2003
  • 응축기, 증발기, 전열관에 사용되는 Fin Tube는 열전달효율 향상을 위하여 Fin의 높이 를 증가시키고, Tube의 최소두께를 얇게 가공하는 경향으로 발전하고 있다. 따라서, Fin Tube의 와전류탐상(ECT; Eddy Current Testing)에 의한 결함검출에 더욱 어려움이 예상된다. 본 연구에서는 Fin Tube의 Fin 높이를 3단계로 변화시켜 Tube를 제작하고, Tube에 축 방향결함, 원주방향결함, 원형결함을 각각 Fin Tube의 안쪽에 최소두께의 20%, 40%, 60% 의 동일결함율을 갖는 인공결함 시험편을 제작하였다. 제작한 원형결함시험편에 와전류탐상을 수행하여 Fin 높이에 따른 최적주파수의 변화를 연구하였다. Fin높이가 다른 원형결함 시험편에 1~20KHz 주파수를 적용한 결과 최적주파수는 12KHz로 Fin높이에 크게 영향을 받지 않음을 밝혔다 또한 Fin높이에 따른 최적주파수변화는 크지 않으나 Fin 높이가 높을수록 100%관통결함의 위상각(40')에 근접하여 나타났다. 축방향결함, 원주방향결함, 원형결함을 갖는 시험편에 와전류탐상을 수행한 결과 원형결함을 갖는 시험편의 신호 감도가 축방향결함, 원주방향결함보다 좋게 나타났다.

  • PDF

Static and Dynamic Fracture Toughness Evaluation in SiCp/6061Al Composite (SiCp/6061Al복합재료의 정적 및 동적파괴인성 평가)

  • An, Haeng-Geun
    • Korean Journal of Materials Research
    • /
    • v.8 no.6
    • /
    • pp.565-570
    • /
    • 1998
  • SiCp/6061AI 복합재료의 파괴인성을 평가하기 위하여 정적파괴인성에 대해서는 복수시험편법을, 동적파괴인성시험에 대해서는 stop block법을 실시하였다. 주균열은 예비균열의 선단에서 시험편두께방향 전역에 걸쳐서 일시에 발생하는 것이 아니고, 균열발생의 초기단계에서 국부적으로 형성된 균열이 시험편두께방향으로의 균열의 확장을 완료한 후 주균열로 이행해 간다. 정적 및 동적시험에서 컴플라이언스변화율법에 의해 검출된 균열발생점은 균열확장의 완료점과 거의 일치하고 있기 때문에 본 재료의 파괴인성 결정에 유효하다. 본 재료에서 동적파괴인성치는 정적파괴인성치보다 크게 나타났다. 이것은 동적충격시 입자파괴에 의한 에너지의 흡수.분산효과와 균열진전경로의 큰 편향에 기인한다고 생각된다.

  • PDF

Improvement of Adhesion Strength of High Temperature Plasma Coated Aluminum Substrate with Aluminum-Alumina Powder Mixture (알루미늄 기지에 알루미늄-알루미나 혼합분말을 이용한 고온플라즈마 열분사 코팅층의 밀착강도 향상기구)

  • Park, Jin Soo;Lee, Hyo Ryong;Lee, Beom Ho;Park, Joon Sik
    • Korean Journal of Materials Research
    • /
    • v.25 no.5
    • /
    • pp.226-232
    • /
    • 2015
  • High temperature plasma coating technology has been applied to recover damaged aluminum dies from wear by spraying pure aluminum and alumina powder. However, the coated mixed powder layer composed of aluminum and alumina often undergoes a detachment from the substrate, making the coated substrate die unable to maintain its expected life span. In this study, in order to increase the bonding strength between the substrate and the coating layer, a pure aluminum layer was applied as an intermediate bond layer. In order to prepare the specimen with variable bond coating conditions, the bond coat layers with a various gun speed from 10 cm/sec to 30 cm/sec were prepared with coating cycle variations ranging from three to nine cycles. The specimen with a bond coat layer coated with a gun speed of 20 cm/sec and three coating cycles exhibited ~13MPa of adhesion strength, while the specimen without a bond coat layer showed ~6 MPa of adhesion strength. The adhesion strength with a variation of bond coat layer thickness is discussed in terms of coating parameters.

JIC Evaluation of the Smooth and the Side-Grooved CT Specimens in the Reactor Pressure Vessel Steel(SA508-3) (원자력압력용기강 (SA508-3)의 평활 및 측면홈 CT시험편을 이용한 J$_{IC}$ 평가)

  • Oh, Sae-Wook
    • Journal of Ocean Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.173-184
    • /
    • 1994
  • 원자력 압력용기강의 탄소성 파괴인성값 $J_IC$를 CT형 시험편을 이용하여 검토하였으며, 평활 시험편 및 측면홈 시험편의 두께는 각각 $B_O$=25.4mm, $B_N$=20.4mm 이다. 측면홈의 깊이는 19.7% 이며, 홈의 각도는 90 .deg.로 가공하였다. 탄소성 파괴인성시험은 ASTM E813-81과 JSME S001-81의 추천방법에 따라 실시하였다. 두 추천방법으로 실험한 결과 ASTM 방법에 의한 $J_IC$값이 과대평가됨으로써 부대조건에 만족되지 못하였지만 JSME방법은 만족되었다. 측면홈 시험편은 R고선법에 의한 ductile tearing의 결정이 평활 시험편보다 용이하였으며, 이에 따른 $J_IC$값의 정확성을 배가 할 수 있었다. 또한 임계 스트레치존 폭($SZW_C$)은 측면홈에 의한 높은 3축응력이 발생되어 평활시험편보다 적게 나타났으며, 이러한 복합적인 원인에 기인하여 스트레치존법에 의한 $J_IC$평가는 R곡선법에 의한 평가보다 약간 과대평가됨을 알 수 있었다.

  • PDF

태양전지용 단결정 실리콘 웨이퍼의 기계적 강도 및 결함 분포

  • Sin, Bong-Geol;Hyeon, Chang-Yong;Lee, Jun-Seong;Park, Seong-Eun;Kim, Dong-Hwan;Byeon, Jae-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.450-450
    • /
    • 2009
  • 최근 전세계적으로 태양전지의 대량보급에 따라 실리콘 원료의 공급에 차질이 생겨 원자재 값이 상승하는 추세에 있다. 결정질 실리콘 태양전지의 제조비용중 실리콘 재료 및 웨이퍼가 차지하는 비율은 약 50~60%정도로 높기 때문에 실리콘 웨이퍼의 두께를 감소시키는 것이 비용절감을 위한 효과적인 방법으로 기대되고 있다. 그러나 실리콘 웨이퍼의 두께가 앓아질수록 제조공정중 균열이나 파손이 발생할 가능성이 높아지기 때문에 이에 따른 실리콘 웨이퍼의 기계적 물성에 대한 연구가 필수적이라 할 수 있다. 본 연구에서는 현재 상용으로 사용되고 있는 크기가 5 인치인 $200{\mu}m$ 두께의 실리콘웨이퍼 (As-saw)를 약 80여개의 시편으로 절단한 후 각각의 파단강도를 부위별로 측정하였다. 또한 표면절단결함을 제거하는 saw damage etching(SDE) 시간을 제어하여 두께가 $150{\mu}m$, $130{\mu}m$인 웨이퍼를 준비하였다. 이들 시험편에 대해서도 부위별 파단강도를 측정하여 as-saw상태의 시험편과 비교하였다. 파단강도 측정은 4 접 굽힘시험을 통하여 측정하였으며 파단면은 주사전자현미경을 통하여 관찰하였다. 또한 실리콘 웨이퍼의 미세균열을 비파괴적으로 검출하기 위하여 100MHz 고주파수를 이용하는 초음파현미경(SAM, scanning acoustic microscope)을 이용하여 균열의 분포를 영상화하였다.

  • PDF

Study on Thickness Measurement about Insulation Rubber of Steel Motor Case Using Ultrasonic Resonance (초음파 공진을 이용한 스틸 연소관의 내열 고무 두께 측정 기법 연구)

  • Kim, Dong-Ryun;Kim, Jae-Hoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.5
    • /
    • pp.89-96
    • /
    • 2012
  • The rubber side could be contaminated using the existing pulse echo method because the ultrasonic wave was incident on the rubber side from the interior of the steel motor case, which could lead to the critical disbond defect. To develop the test method which can be replaced the existing method, the ultrasonic wave was incident on steel face of the steel/rubber adhesive test block. Rubber resonance frequencies measured from the steel/rubber adhesive test block were in good agreement with theoretically predicted rubber resonance frequencies. This paper was described about the ultrasonic resonance method to convert the rubber resonance frequency into the rubber thickness.

Study on Thickness Measurement about Insulation Rubber of Steel Motor Case Using Ultrasonic Resonance (초음파 공진을 이용한 스틸 연소관의 내열 고무 두께 측정 기법 연구)

  • Kim, Dong-Ryun;Kim, Jae-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.562-569
    • /
    • 2012
  • The rubber side could be contaminated using the existing pulse echo method because the ultrasonic wave was incident on the rubber side from the interior of the steel motor case, which could lead to the critical disbond defect. To develop the test method which can be replaced the existing method, the ultrasonic wave was incident on steel face of the steel/rubber adhesive test block. Rubber resonance frequencies measured from the steel/rubber adhesive test block were in good agreement with theoretically predicted rubber resonance frequencies. This paper was described about the ultrasonic resonance method to convert the rubber resonance frequency into the rubber thickness.

  • PDF