• Title/Summary/Keyword: 시험식

Search Result 3,804, Processing Time 0.031 seconds

Suggestion for Non-Destructive Testing Equation to Estimate Compressive Strength of Early Strength Concrete (조기강도 콘크리트의 압축강도 추정을 위한 비파괴검사 실험식의 제안)

  • Lee, Tae-Gyu;Kang, Yeon-Woo;Choi, Hyeong-Gil;Choe, Gyeong-Choel;Kim, Gyu-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.3
    • /
    • pp.229-235
    • /
    • 2016
  • In construction field, it used various technique for concrete formwork. Part of them, non-destructive test has been conducted to estimate a compressive strength of concrete easily such as rebound method and ultrasonic pulse velocity method etc. Former research has recommend proposed equation based on experimental data to investigate strength of concrete but it was sometimes deferent actual value of that from in field because of the few of data in case of early strength concrete. In this study, an experiment was conducted to analyze strength properties for early strength concrete using cylinder mold and $1,000mm{\times}1,000mm{\times}200mm$ rectangular specimen. And compressive strength of concrete was tested by non-destructive test, and calculated by the equation proposed former research. As a result, the non-destructive test results showed approximately 70 percent of the failure test value for all conditions, and worse reliability was obtained for high strength concrete samples when the ultrasonic pulse velocity method was used. Based on the scope of this study, the experimental equation for estimating compressive strength of early strength concrete from 24MPa to 60MPa was proposed.

Strength Prediction Equations for High Strength Concrete by Schmidt Hammer Test (슈미트 해머 시험에 의한 고강도 콘크리트의 강도 추정식)

  • Kwon, Young-Wung;Park, Song-Chul;Kim, Min-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.389-395
    • /
    • 2006
  • For the assessment of exsiting concrete structures, it is important to get the real strength of concrete. The load test or core test has many problems due to cost time, easiness, structural damage, and reliability and so on. Thus, various non-destructive test and statistical analysis techniques for strength assessment have been developed. As a result the real strength of concrete can be obtained by both direct and indirect test. In this study, a series of experimental tests of core strength and Schmidt hammer tests on 3, 7, 14, 28, 90, 180, 365, and 730 days' were done for predicting the compressive strength of high strength concrete with 65.0MPa of 28-days' strength. Each experimental results was analyzed by simple regression analysis. Then, reliability level and error rate between the proposed equations and the existing ones was examined. However, the application of the exsisting equations was inadequate to high strength concrete, because they were conducted under normal strength concrete. Therefore, the following compressive strength equations were proposed for predicting the compressive strength of high strength concrete by Schmidt hammer test. The proposed equations by Schmidt hammer test are as follows.

The Ground Test and Evaluation to Verify Engine Performance of Sea-Star I (해성I의 공기흡입식 엔진 성능 검증을 위한 지상시험평가)

  • Jung, Jae-Won;Kim, Jong-Jin;Park, Sang-Woo;Kim, Sang-Yong;Kim, Moo-Gon;Kim, Tae-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.381-384
    • /
    • 2009
  • The Air-breathing engine like Sea-Star I is a second propulsive force generator to fly to the target after the booster generating initial propulsive force is separated. The performance of Sea-Star I engine should be verified because the cruise missile controls direction and altitude during flight, so ground engine test is executed before flight test. This these presents evaluation method of ground engine test to verify performance of Sea-Star I's engine.

  • PDF

Comparison of Ultimate Bearing Capacity Formulas for Single Stone column in Bulging and General shear failure using in-situ test results (현장 시험치를 이용한 단일 쇄석다짐말뚝의 Bulging 및 General Shear Failure시의 극한지지력 제안식에 관한 비교 연구)

  • Chun, Byung-Sik;Kim, Won-Cheul;Seo, Deok-Dong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.2
    • /
    • pp.65-76
    • /
    • 2003
  • Stone column is a soil improvement method and can be applicable for loose sand or weak cohesive soil. Since the lack of sand, stone column seems one of the most adaptable approach for poor ground as a soil improvement technique. However, this method was not studied for practical application. In this paper, the bearing capacity of single stone column at the Gaduk, Ulsan and Gwangyang under the bulging and general shear failure mode were compared with those of the suggested formulas. Especially, a test result of single stone column at the Busan area by static load was compared with the bearing capacity of suggested formulas. The analysis results showed that there were not much bearing capacity differences among those suggested bearing capacity formulas. However, the bearing capacity by static load test was almost double of those with suggested formula. The result also showed that the undrained shear strength was the most important parameter for the bearing capacity estimation of stone column.

  • PDF

Study on Comparison of Methods for Estimation of Shear Wave Velocity in Core Zone of Existing Dam (기존 댐 코어죤의 전단파속도 산정기법 비교 연구)

  • Ha, Ik-Soo;Oh, Byung-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.10
    • /
    • pp.33-43
    • /
    • 2008
  • In this study, for the purpose of evaluating the shear wave velocity in core zone, cross-hole test, down-hole test, MASW (Multi-channel Analysis of Surface Wave), and seismic reflection survey were carried out on the crest of the existing 'Y' dam. The results of field tests were compared one another. Furthermore, the field test results were compared with the result by the Sawada's empirical recommendation method. The purpose of this study is to compare the results of four kinds of field tests for evaluation of shear wave velocity in core zone of existing dam, to verify applicability of the empirical method which was recommended by Sawada and Takahashi, and to recommend a reasonable method for evaluation of shear wave velocity which is needed to evaluate tile maximum shear modulus of core zone. From the results of four kinds of field tests such as cross-hole test, down-hole test, MASW, and seismic reflection survey, it was found that the shear wave velocity distributions were similar within 18 m in depth and the results obtained by MASW and seismic reflection survey were almost the same by 30 m in depth. For evaluation of shear wave velocity in core zone of the existing dam, in consideration that it is not easy to bore the hole ill the core zone of existing dam, surface surveys such as MASW and seismic reflection method are recommended as realistic methods. On condition that it is impossible to conduct the field test and it is preliminary investigation, it is recommended that Sawada's low bound empirical equation be used.

Splice Performance Evaluation of Fastening Coupler According to the Slope Length of Internal Fasteners (조임쇠 경사길이에 따른 체결식 커플러의 이음성능 평가)

  • Jung, Hyun-Suk;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.11-19
    • /
    • 2022
  • In this study, in order to improve the splice performance of mechanical couplers, two new mechanical couplers with different connection modes were developed with rebar(SD400). The stress analysis of mechanical couplers with two different connection modes was carried out. Uniaxial tensile tests were carried out with type of steel, connection mode and the slope length of internal fastener as variables to analyze the influence on the maximum tensile strength. Building upon this previous work, the specimens that met the code in uniaxial tensile test were fabricated and static loading test and cyclic loading test were performed on the basis of Korean code(KS D 0249). The results of this research are as follows; (1) The tensile strength of steel and the slope length of internal fasteners have a certain influence on the maximum tensile strength. (2) The connection mode has some influence on the stiffness, slip and stiffness reduction rate of the connecting rebars. The results verify the feasibility of the proposed enhanced mechanical coupler in the field.

Estimation of Concrete Strength Based on 7-day Strength (콘크리트의 7일강도를 이용한 28일 강도의 추정)

  • 김선영;권태수;이수곤
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.1
    • /
    • pp.119-124
    • /
    • 1998
  • 콘크리트는 시멘트, 잔골재 및 굵은 골재, 물 및 첨가제의 양이나 투입순서 ,혼합방법등 여러 가지 요인에 따라 성질이 바뀌게 되는 복합재료이다. 따라서 넓은 의미에서 품질 판정의 한 수단이 되는 콘크리트의 설계기준강도 또는 압축강도 fc'(=28일 압축강도)는 물론 기타의 성질도 정확한 예측이 불가능하다. 즉 소요강도를 목표로 배합된 공시체의 시험결과는 예외없이 통계적 가변성을 나타낸다. 여기에서는 공시체의 7일 강도의 평균치 및 표준 편차와 공시체의 28일 강도 측정치로부터 콘크리트의 압축강도를 추정하는식을 제안하였다. 이를 위하여 7,320개의 강도시험자료를 수집한 후 이들을 선형 회귀 분석법으로 처리하였다. 제안된 식에 의한 콘크리트의 압축강도는 타 추정식에 의한 값보다 실측치에 좀 더 근접함을 보여주었다. 또한 제안식의 검정을 위해 서울지역 자료 5,200개를 수집하여 제안식과 JIS, Slater식과의 오차를 비교한 결과에 따르면 제안식이 더 안전측임을 알 수 있었다. 그리고 슈미트 햄머에 의한 현장 실측 강도와 제안식과의 콘크리트 강도 오차는 대체로 2.3%이었다.

Development of screw attached corn drum type garlic separator (나선부착 원추 드럼식 마늘쪽 분리기 개발)

  • 이영희;조남홍;박종률;최승묵;조광환;김재규
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.317-322
    • /
    • 2002
  • 농가보급형 마늘쪽 분리기 개발을 위하여 마늘의 품종별 기하학적 특성을 분석하고, 나선 부착 원추 드럼식 마늘쪽 분리기를 제작하여 성능시험 및 농가 현장시험한 결과를 요약하면 다음과 같다. 1)종구용 통마늘의 크기를 조사한 결과 직경은 의성, 무안, 자봉이 각각 44.3, 51.9, 60.2mm로 나타났다. 2)통마늘의 최대 압축력 및 마늘쪽의 생물체항복 강도를 시험한 결과 수평방향 최대 압축력은 의성, 무안, 자봉마늘이 각각 185.1, 145.8, 148.5N이고, 마늘쪽의 생물체 항복강도는 의성, 무안, 자봉마늘이 각각 272.4, 336.2, 413.2N/$cm^2$로 통마늘은 의성종이 단단 하나 마늘쪽은 무안이나 자봉마늘에 비해 단단하지 않은 것으로 나타났다. 3)나선부착 원추 드럼 및 경사원통식 마늘쪽 분리장치를 제작하여 성능시험한 결과 1쪽 분리율이 의성, 무안, 자봉마늘에서 각각 58.2, 64.7, 95.2%이고, 손상율은 각각 2.0, 2.4, 1.9%이었으며 작업능률은 시간당 210kg(약 60접)이었다. 4)시작기를 전남무안의 재배농가에서 현장 시험한 결과 1쪽분리율은 75.9%, 손상율은 0.8%, 파종 후 출현율이 94.3%로 농가적응성 및 실용성이 높은 것으로 판단되었다.

  • PDF

Development of Calibration Equation of Portable Slip Meter(ONO·PPSM) through Comparative test of O-Y·PSM and ONO·PPSM (경사인장형 미끄럼시험기(O-Y·PSM)와의 비교실험을 통한 휴대형 미끄럼시험기(ONO·PPSM)의 교정식 작성)

  • Shin, Yoon-Ho;Choi, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.5
    • /
    • pp.155-161
    • /
    • 2009
  • This paper is the result of an investigation of a PORTABLE SLIP METER(ONO PPSM) by means of an experiment to determine its validity as a slip meter. ONO PPSM is a portable slip meter that was designed to address the weak points of PULL SLIP METER(O-Y PSM), which can be used to obtain an accurate measurement of slip resistance, but is very heavy and difficult to operate. To determine the stability of the measurement result of ONO PPSM, we measured the slip resistance against 4 different kind of floor materials. Our findings showed that the coefficient of variability of CSR' is less than 0.05. Furthermore, we verified the relationship between CSR' and CSR. More specifically, by performing the slip test against 7 different kinds of inorganic matter floor materials, we increased the usability of ONO PPSM as a slip meter by suggesting a method of sharing the evaluation index of slip of CSR' and C.S.R.

Characterization of In-plane Shear Behaviors of Woven Fabrics by Bias-extension and Trellis-frame Tests (편향 인장 및 트렐리스 시험에 의한 직물 복합재료의 면내 전단 물성 평가)

  • Lee, Won-Oh;Um, Moon-Kwang;Byun, Joon-Hyung;Cao, Jian
    • Composites Research
    • /
    • v.23 no.5
    • /
    • pp.8-14
    • /
    • 2010
  • Three types of glass woven fabrics (plain, balanced twill, and unbalanced twill) having various sample sizes and aspect ratios were tested using the bias-extension tests. Real-time deformation images, force, and displacement data were collected. For the bias-extension test, the shear angle of the fabrics from the equation based on the crosshead displacement and fabric size was compared with direct manual measurements of the warp and weft angles as well as the optical measurement software. To determine the shear force, an analytical equation was introduced considering the kinematics of the bias-extension test. The obtained shear behaviors were further compared with the results by the trellis-frame test. The optical measurement methods showed that the mathematical method was reasonable before the shear angle of the fabrics reaches $30^{\circ}$ in the bias-extension tests. Also, the bias-extension test gave consistent behaviors with the trellis-frame test only for isotropic and homogeneous fabrics such as balanced plain and twill weaves.