• Title/Summary/Keyword: 시스템 열펌프

Search Result 422, Processing Time 0.026 seconds

Economic Analysis of Heat Pump System through Actual Operation (히트 펌프 냉난방 시스템의 실사용을 통한 경제성 분석)

  • Shin, Gyu-Won;Kim, Gil-Tae;Joo, Ho-Young;Lee, Jae-Keun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.921-926
    • /
    • 2006
  • The present study has been conducted economic analysis through actual operation of EHP and GHP which are installed at the same building of an university Cost items, such as initial cost, annual energy cost and maintenance cost of each system are considered to analyze LCC and economical efficiency is compared. The initial cost is considered on the basis of actual costs, and annual energy cost is converted into the cost after measuring electricity and gas consumption a day. LCC applied present value method is used to assess economical efficiency of both them. Variables used to LCC analysis are electricity cost escalation rate, natural gas cost escalation rate, interest rate, and service lives and when each of them are 4%, 2%, 8%, and 20 years, results of analysis short that EHP(148,257,306 won) is 8.05%(12,981,990 won) more profitable than GHP(161,239,295 won).

  • PDF

A Study on Performance Improvement of Heat Pump Adopting the Hot Gas Bypass Method (고온냉매 우회방법을 적용한 열펌프의 성능 개선 연구)

  • Kang, Shin-Hyung;Byun, Ju-Suk
    • Journal of Energy Engineering
    • /
    • v.15 no.4 s.48
    • /
    • pp.235-242
    • /
    • 2006
  • This study experimentally investigates the performance improvement of the heat pump by adopting the hot gas bypass method and using the internal heat exchanger according to the automatic defrost test conditions of ISO 5151 This study compares the hot gas bypass method with the time step method, and investigates effect on outdoor coil fan speed when the hot gas of compressor outlet enter outdoor coil inlet after the frost formation. The tests were made for the fan speeds of the outdoor coil controlled at 90, 60 and 30% of the normal speed together with the case of the stationary fan. The performance of the heat pump is evaluated by variables such as COP, heat capacity, and the average COP during the 210 minutes heating mode. Results show that average COP of the hot gas bypass mettled is $2.2{\sim}6%$ higher than that of the time step method. When the outdoor coil fan speed is 60% (780 rpm) of the normal speed, it shows the best COP and heating capacity.

Study on the performance of a heat pump system with serial dehumidification function (직렬 제습방식 열펌프 시스템의 성능특성에 관한 연구)

  • Ko, Wonbin;Ko, Ji-Woon;Park, Youn Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.609-614
    • /
    • 2014
  • In this research, results of measuring temperature and relative humidity of underground-air-heat in Jeju showed $15{\sim}18^{\circ}C$ and 70~80% each which are somewhat high compare to other regions. So the Multi-effect dehumidifying and heating Heat Pump system which has merged functions of dehumidification and heating is made to solve this problem mentioned previously. When the suction air was $15^{\circ}C$ with 60% humidity, the outcome was 1.70 on $COP_h$ and 1.797(kg/h) on total amount of dehumidification, and also showed 1.87 $COP_h$ with 1.87 total amount of dehumidification under the condition of $20^{\circ}C$ and 80% humidity of suction air. Furthermore, $COP_h$ showed increased number which is 1.87 and also total amount of dehumidification increased which was 3.269(kg/h). The highest COP can be achieved at $17^{\circ}C$ and 70% relative humidity condition.

A Study on Horizontal Ground Source Heat Pump Systems (수평형 지열원 히트펌프 시스템에 관한 연구)

  • Park, Yong-Jung;Kim, Kyoung-Hoon
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.160-165
    • /
    • 2006
  • Ground source heat pump (GSHP) or geothermal heat pump systems (GHPs) are recognized to be outstanding heating and cooling systems. Most of GSHP systems installed and studied in korea are vertical GSHP systems. A horizontal GSHP system was installed in greenhouse and investigated for the performance characteristics. The results of the study showed that the heating coefficient of performance of the heat pump was 3.64 and the overall heating coefficient of performance of the system was 3.31. The pumping power was obtained as 28.0 W/kW and the required ground heat exchanger length was 53.3 m/kW of rejection heat of condenser. The heat extraction rate was, on average, 14.58 W/m of ground heat exchanger length and trench length is 27.7 m/kW of rejection heat of condenser.

Time Series Analysis of the Effect of Ground-source Heat Pumps on Groundwater Characteristics (시계열 분석을 이용한 지열히트펌프 가동에 따른 지하수특성변화 해석)

  • Mok, Jong-Gu;Lim, Hong-Gyun;Jang, Bum-Ju;Park, Yu-Chul;Lee, Jin-Yong
    • The Journal of Engineering Geology
    • /
    • v.21 no.1
    • /
    • pp.35-43
    • /
    • 2011
  • Time series analysis was applied to groundwater level, water temperature, and electrical conductivity data obtained from monitoring wells around ground-source heat pumps at Sangji University of Wonju (standing column well type) and at Jungwon University of Goesan (closed loop type), from 21 May to 12 October 2010. We found large temporal variations in the characteristics of groundwater at Wonju, but only minor variations at Goesan. These results may improve our understanding of the effects of ground-source heat pumps on the characteristics of surrounding groundwater, according to the installation method for the pumps.