• Title/Summary/Keyword: 시료채취 기준

Search Result 328, Processing Time 0.032 seconds

A Monitoring Survey on Pesticide Residues in Strawberries and Cucumbers from plastic Film Houses (시설재배 딸기와 오이 중 농약잔류에 관한 조사 연구)

  • 이해근;김영구;박영선
    • Journal of Food Hygiene and Safety
    • /
    • v.3 no.4
    • /
    • pp.193-202
    • /
    • 1988
  • A pesticide monitoring study was undertaken for the strawberry and cucumber samples collected from plastic film houses and additional strawberries from supermarkets located in Seoul city in 1983 to evaluate pesticide residues in these food commodities and also to give basic informations in establishing maximum residue limits. Organophosphorus insecticides were not detected in any cucumber samples except that diazinon found with low residue levels in two strawberry samples. Fungicide procymidone and chlorothalonil were detected with considerable high frequencies in these vegetables while their residue levels were fairly low. Even the maximum residue levels. they were much lower than maximum residue limits established in these vegetables in Environment Administration. Korea. Of the strawberries from supermarkets in Seoul city, procymidone, chlorthalonil and dichlofluanid fungicides were also detected with similar detection frequencies and residue levels to those from the plas tic film houses. By washing the strawberries with tap water, the residues were removed from 38% to 95% of the total residues. Presently, it is considered that pesticide residues in strawberry and cucumber may be no harmfullevels for food commodities.

  • PDF

Establishment of Pre-Harvest Residue Limit for Buprofezin and Penthiopyrad during Cultivation of Oriental melon (Cucumis melon var. makuwa) (참외(Cucumis melon var. makuwa)에 대한 Buprofezin 및 Penthiopyrad의 생산단계 잔류허용기준 설정)

  • Kim, Hea Na;Kim, Seong Beom;Choi, Eun;Woo, Min Ji;Kim, Ji Yoon;Saravanan, Manoharan;Hur, Jang Hyun
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.3
    • /
    • pp.123-129
    • /
    • 2014
  • The present work was aimed to determine the pre-harvest residue limits (PHRLs) and the safety management of commonly used pesticides namely buprofezin and penthiopyrad on oriental melon (Cucumis melon var. makuwa). In this study, the buprofezin (diluted two thousand fold) and penthiopyrad (diluted four thousand fold) were sprayed single time on oriental melon in the cultivation areas Sangju (site 1) and Sungju (site 2). Oriental melon were randomly collected from the both areas at the end of 0 (2 hours after pesticides spaying), 1, 2, 3, 5, 7, 9 and 10 days. For analysis, each samples were partitioned twice (80 and 70 mL) with dichloromethane and purified by florisil SPE cartridge. Finally, the residual amounts of both pesticides in all samples were analyzed using gas chromatography/nitrogen phosphorus detector (GC/NPD). In this study, the method limit of quantification (MLOQ) for both buprofezin and penthiopyrad in oriental melon was found to be $0.01mg\;kg^{-1}$ and their recovery levels were 91.1~98.6% and 90.0~104.6%, respectively. Further, the calculated biological half-life for buprofezin and penthiopyrad in oriental melon were 3.9 and 3.5, and 3.0 and 2.7 days in site 1 and 2, respectively. The results of this study found that the PHRLs for buprofezin and penthiopyrad were 4.24 and $2.31mg\;kg^{-1}$, respectively at 10 days before harvest. Consequently, the present study suggest that the residual amounts of both pesticides will be lower than the maximum residue limits (MRLs) when oriental melon is harvested.

Translocation of Tolclofos-methyl from Ginseng Cultivated Soil to Ginseng (Panax ginseng C. A. Meyer) and Residue Analysis of Various Pesticides in Ginseng and Soil (토양 중 잔류된 Tolclofos-methyl의 인삼(Panax ginseng C. A. Meyer)에 대한 이행 및 잔류 특성)

  • Kim, Ji Yoon;Kim, Hea Na;Saravanan, Manoharan;Heo, Seong Jin;Jeong, Haet Nim;Kim, Jang Eok;Kim, Kwan Rae;Hur, Jang Hyun
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.3
    • /
    • pp.130-140
    • /
    • 2014
  • Recently, some of the previous studies reported that tolclofos-methyl is still exist in ginseng cultivated soil, even though it is has been banned for ginseng. Therefore, the current study was aimed to examine the levels of absorption and translocation of tolclofos-methyl from ginseng cultivated soil to ginseng root and leaf stem for the period of 1 year. For this study, ginseng plants were transplanted in pots and treated with $5.0mg\;kg^{-1}$ of tolclofos-methyl (50% WP). At the end of each interval periods (every three months) the samples (soil, roots and leaf stems) were collected and analyzed the absorption and translocation levels of tolclofos-methyl using gas chromatography and mass spectrometry (GC-MS). The limit of quantitation of tolclofos-methyl was found to be $0.02mg\;kg^{-1}$ and 70.0~120.0% recovery was obtained with coefficient of variation of less than 10% regardless of sample types. In this study, a considerable amount of translocation of tolclofos-methyl residues were found in soil (4.28 to $0.06mg\;kg^{-1}$), root (7.09 to $1.54mg\;kg^{-1}$) and leaf stem (0.79 to $0.69mg\;kg^{-1}$). The results show that the tolclofos-methyl was absorbted and translocated from ginseng cultivated soil to ginseng root and ginseng leaf stem and found to be decreased time-coursely. Secondly, we were also analyzed soil, root and leaf stems samples from Hongcheon, Cheorwon, Punggi and Geumsan by GC-MS/MS (172 pesticides), LC-MS/MS (74 pesticides). In this study, 43 different pesticides were detected ($0.01{\sim}7.56mg\;kg^{-1}$) in soil, root and leaf stem. Further, tolclofos-methyl was detected 4 times separately in root sample alone which is less ($0.01{\sim}0.05mg\;kg^{-1}$) than their maximum residual limit (MRL) in ginseng. Consequently, the results from both studies indicate the residues of tolclofos-methyl found in ginseng cultivated soil and ginseng ensuring their safety level. Moreover, long-term evaluations are needed in order to protect the soil as well as ginseng free from tolclofos-methyl residues.

Physicochemical Characteristics and Analysis of Pollution Potential in the Sediments of the Rivers Flowing into the Saemangeum Reservoir (새만금호 유입 하천 하상 퇴적물의 물리화학적 특성과 오염도 분석)

  • Oh, Kyoung-Hee;Yu, Mi-Na;Cho, Young-Cheol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.12
    • /
    • pp.861-867
    • /
    • 2011
  • In order to understand the extent of contamination of the sediments on the Mankyoung and Dongjin Rivers flowing into the Saemangeum Reservoir, the concentrations of ignition loss (IL), COD, total nitrogen (T-N), total phosphorus (T-P), and heavy metals (As, Cd, Cr, Pb, Zn) were measured. The average concentrations of IL, COD, and T-P were 2.40 (${\pm}2.18$)%, 2.97 (${\pm}3.06$) mg/g sediment, 0.370 (${\pm}0.351$) mg/g sediment, respectively, showing the extent of contamination is not serious. However, the concentrations of these parameters in the samples taken in year 2009 were higher than those in year 2008, indicating the contamination of sediments goes on gradually. The concentrations of T-N were in the range of 0.59~13.11 mg/g sediment with variation of locations and seasons. It was determined that the T-N contamination is serious when the concentrations were compared with the dredging guidelines of sediments in the Korean freshwaters, indicating the countermeasures are required to maintain the water quality of the Saemangeum Reservoir. The concentrations of heavy metals except chromium did not exceed the worrisome level of soil contamination stipulated by the Soil Environment Conservation Act of Korea. The high concentration of chromium to be concerned in some samples from the upstream of Mankyoung River requires source analysis and countermeasure to control the contamination.

Explosion Characteristics Analysis of Low-Density Polyethylene Dust (저밀도 폴리에틸렌 분진의 폭발특성 분석)

  • Hyun-gil Kwon;Kyeong-seok Oh;Jong-bae Baek;Dong-hyun Seo
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.80-88
    • /
    • 2023
  • Ensuring safety in the designing of manufacturing and handling facilities for low-density polyethylene (LDPE) is difficult because there are no standards for the dust explosion characteristics of LDPE. In this study, a dust explosion test was performed on two dust samples collected from a bag filter (LDPE 1) during the LDPE manufacturing process and sedimentary dust (LDPE 2) leaked outside a facility such as a silo, and the LDPE 2 explosion test results were summarized. Particle size analysis showed that the volume-based particle diameter (median) was 95.04 ㎛ and the number density was 0-1 ㎛. The maximum explosion pressure (Pmax) was 6.6 bar, and the maximum rate of explosion pressure rise was 366 [bar/s] at 1500 g/m3. Accordingly, the dust explosion index (Kst) was 99.4 bar·m/s, which was confirmed as ST-1 grade. Moreover, the minimum ignition energy and minimum ignition temperature was 10 mJ and 450 ℃, respectively. Currently, manufacturing and handling design is based on the characteristic values of high-density polyethylene (HDPE). However, as the test results show that LDPE 2 dust has a higher risk than HDPE (particle diameter 61.6 ㎛), caution is required when using the HDPE design criteria in the LDPE manufacturing process.

Silver Contamination in Drinking Water of Gyeongbuk Area in Korea (경북 지역 먹는 물의 은 검출 특성)

  • Lee, Hea Geun;Kim, Jeong Jin;Kim, Young Hun
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.3
    • /
    • pp.233-242
    • /
    • 2020
  • As studies and developments of nano-material increase, the release of the nano-sized material to water environment increase. Especially, silver nanoparticles have been found as dissolved and particulate state since nano-silver particle have been intensively used in industrial and our living environment due to the anti-bacterial effect of the nano-particles. The silver nano-particles and silver ion gives adverse effect on ecology and US-EPA set a secondary drinking water standards as 0.1 mg/L. Current study focused on the analysis of silver in groundwater, small scale water supply systems in Gyeongbook area. The results have been compared with the secondary drinking water standards and discussed at the point of characteristics of the local area and purpose of use of the water sample. Among the total of 298 samples, 2 samples exceed the secondary drinking water standards of EPA, 0.64% rate. Community drinking water and simplified water service showed relatively high detection rate and groundwater gave relatively higher concentration of silver indicating anthropogenic source and natural source could contribute simultaneously on groundwater.

Distribution of Organic and Inorganic Arsenic Species in Groundwater and Surface Water Around the Ulsan Mine (울산광산 주변지역 수계에서 유기 및 무기 비소 종 분포)

  • Kim, Youn-Tae;Woo, Nam-Chil;Yoon, Hye-On;Yoon, Cheol-Ho
    • Economic and Environmental Geology
    • /
    • v.39 no.6 s.181
    • /
    • pp.689-697
    • /
    • 2006
  • Distribution and speciation of arsenic in water resources was investigated in the Ulsan mine area. In 62% of uoundwater samples from the mine area, total As concentrations exceeded 0.05 mg/l, the Korean Drinking Water Standard. As(V) was the major type in groundwater with minor As(III). Arsenic species appeared to be in transition stages following redox changes after exposure to the air through the monitoring wells. In areas around the mine, the mine and Cheongog spring appeared to be the sources of arsenic contamination of water resources. The spring showed 0.345 mg/1-As, as much as seven times of the Korean standard. Groundwater and stream samples showed As-concentrations greater than 0.05 mg/l in 30% and 33% samples, respectively, and 60 and 67% of samples exceeded 0.01 mg/l of WHO guideline, respectively. Again, As(V) was a dominant species, however, several samples had As(III) in appreciable levels. In one stream sample, organic species including DMA and AsB were detected in low levels, probably resulted from transformation or related biogeochemical processes.

A Study on Developing the Enhancement Method for the Reusability of GIS Component (GIS 컴포넌트의 재사용성 향상을 위한 기법 개발 연구)

  • 조윤원;조명희
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2004.03a
    • /
    • pp.599-605
    • /
    • 2004
  • 기존의 구축된 GIS 컴포넌트 혹은 개발 중이거나 향후개발을 목표로 설계단계에 있는 컴포넌트들의 최종 목표는 재사용성과 상호운용성의 가능성 여부이다. 하지만 컴포넌트 개발에 있어 시스템 개발환경의 다양성으로 인하여 그 재활용성은 생각만큼 쉬운 작업이 아니며, 특히 공간정보를 다루고 있는 GIS(Geographic Information System)분야에서의 GIS 컴포넌트 재활용은 전 세계의 산재한 각 데이터형의 포맷, 개발 환경, 운영환경을 고려하여 볼 때 시급한 일임에도 불구하고 그에 대한 노력이 상당히 미진한 실 정 이 다. 본 논문에서는 GIS 애플리케이션을 보다 효율적이고 유용하게 개발하기 위하여 GIS 컴포넌트의 개발과 관리에 이르는 전 과정을 관리 감독할 수 있는 COGIS(Component Oriented Geographic Information System)을 제안하고, COGIS 프로세스의 가이드라인이며 GIS 컴포넌트의 기능적인 면을 정의하기 위한 GCA(GIS based Component Architecture) 아키텍처를 제안하였다. 아울러 GIS 컴포넌트의 메타데이터를 분류 및 정의하여 GIS 컴포넌트의 비 기능적면을 제시하고 이를 이용하여 웹 기반 GIS 컴포넌트 등록/검색 에이전트 시스템을 개발하였으며 기존 GIS 컴포넌트 재사용 및 확장, 신규 컴포넌트의 등록, 검색이 가능하도록 한다. 사례연구로 웹 상에서 산불 발생 위험지수 표출을 위한 GIS 공간 분포도 작성이 쉽게 이루어지도록 2FDRV.avx와 2FDRC.exe 컴포넌트를 개발하였으며, COGIS 프로세스의 컴포넌트 관리방법을 통하여 여러 관련 컴포넌트를 조합함으로써 웹 기반 산불위험지수예보시스템을 구축하였다.입력 근거의 확보’, ‘갱신주체별 역할의 정의 및 유지관리 기준의 설정’, ‘분야별업무 특성을 고려한 관련 기준의 마련 및 타 시스템과 연계되는 항목을 고려한 절차 정의’ 등에 대한 다양한 접근을 시도하였다. 본 연구에서 제시하는 유지관리 모델을 기반으로 각 지자체별로 적절한 컨설팅이 진행되고 이에 따라 담당자의 실천이 이루어진다면 지자체 GIS의 투자대비 효과에 대한 기대는 이상이 아닌 현실로 다가오게 될 것이다.가오게 될 것이다. 동일하게 25%의 소유권을 가지고 있다. ?스굴 시추사업은 2008년까지 수행될 계획이며, 시추작업은 2005년까지 완료될 계획이다. 연구 진행과 관련하여, 공동연구의 명분을 높이고 분석의 효율성을 높이기 위해서 시료채취 및 기초자료 획득은 4개국의 연구원이 모여 공동으로 수행한 후의 결과물을 서로 공유하고, 자세한 전문분야 연구는 각 국의 대표기관이 독립적으로 수행하는 방식을 택하였다 ?스굴에 대한 제1차 시추작업은 2004년 3월 말에 실시하였다. 시추작업 결과, 약 80m의 시추 코아가 성공적으로 회수되어 현재 러시아 이르쿠츠크 지구화학연구소에 보관중이다. 이 시추코아는 2004년 8월 중순경에 4개국 연구팀원들에 의해 공동으로 기재된 후에 분할될 계획이다. 분할된 시료는 국내로 운반되어 다양한 전문분야별 연구에 이용될 것이다. 한편, 제2차 시추작업은 2004년 12월에서 2005년 2월 사이에 실시될 계획이다. 수백만년에 이르는 장기간에 걸쳐 지구환경변화 기록이 보존되어 있는 ?스굴호에 대한 시추사업은 후기 신생대 동안 유라시아 대륙 중부에서 일어난 지구환경 및 기후변화를 이해함과 동시에 이러한 변화가 육상생태계 및 지표지질환경에 미친 영향을 이해하는데 크게 기여할 것이다.

  • PDF

A Study on Generating a Coastal Flood Hazard Map (국내 적합한 연안침수지도제작에 관한 연구)

  • 원대희;김계현;박태옥;최현우;곽태식
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2004.03a
    • /
    • pp.435-440
    • /
    • 2004
  • 연안침수지도는 태풍이나 해일에 의한 연안침수 발생 시 방조제의 월류 및 붕괴로 인한 예상 침수구역을 강우빈도(200년)별로 나타내고, 침수면적과 깊이를 표현한 지도로서 국외 선진국에서 방재형 국토관리 정책결정과 침수피해에 대한 대민 홍보의 수단으로 활용되고 있다. 국내에서도 연안침수에 의한 피해가 나날이 커지고 국토의 개발에 따른 자연 재해가 많아짐에 따라 보다 방재형 국토개발로 국민의 안전과 복리를 증진하고, 연안침수에 의한 피해를 최소화하기 위한 노력의 일환으로 연안침수지도의 제작 필요성이 증대되고 있다. 본 연구의 시범지역인 대부도 남부지역의 GIS 데이터베이스 구축은 문헌조사 및 기구축 데이터 확보, 지역의 특성에 맞는 신규 GIS 데이터베이스 구축 방법을 제시하였다. 침수구역을 예측하기 위한 모델링을 지원하기 위한 정확도와 경제성, 객관성, 현실성이 높은 지형공간자료의 효율적인 구축이 강조되었다. 구축한 데이터베이스의 세부 유형은 침수위험구역, 침수경계구역, 침수량 화살표이며, 기존에 구축된 데이터를 활용한 레이어는 해안선, 도로, 건물, 등고선, 등심선, 연안 표고점 측량데이터이다. 연안침수지도는 효율적인 재난관리를 위하여 다양하게 활용될 수 있을 것으로 사료되며 나아가 주민의 침수에 대한 경각심 고취와 사전 교육, 지방자치단체의 침수위험 관리업무의 활용이 가능할 것으로 사료된다. 본 연구에서 제작된 연안침수지도는 지자체 주민들을 위해 보기 쉽고 다양한 정보를 얻을 수 있도록 제작되었으며, 이를 위해 사진과 삽화를 추가하여 주민들에게 침수피해에 대한 경각심과 이해를 높이는데 중점을 두었다. 유지관리 후 활용체계 정비의 중요성’을 점검하고, ‘변동자료 발생원인의 분석’, ‘명확한 변동자료 입력 근거의 확보’, ‘갱신주체별 역할의 정의 및 유지관리 기준의 설정’, ‘분야별업무 특성을 고려한 관련 기준의 마련 및 타 시스템과 연계되는 항목을 고려한 절차 정의’ 등에 대한 다양한 접근을 시도하였다. 본 연구에서 제시하는 유지관리 모델을 기반으로 각 지자체별로 적절한 컨설팅이 진행되고 이에 따라 담당자의 실천이 이루어진다면 지자체 GIS의 투자대비 효과에 대한 기대는 이상이 아닌 현실로 다가오게 될 것이다.가오게 될 것이다. 동일하게 25%의 소유권을 가지고 있다. ?스굴 시추사업은 2008년까지 수행될 계획이며, 시추작업은 2005년까지 완료될 계획이다. 연구 진행과 관련하여, 공동연구의 명분을 높이고 분석의 효율성을 높이기 위해서 시료채취 및 기초자료 획득은 4개국의 연구원이 모여 공동으로 수행한 후의 결과물을 서로 공유하고, 자세한 전문분야 연구는 각 국의 대표기관이 독립적으로 수행하는 방식을 택하였다 ?스굴에 대한 제1차 시추작업은 2004년 3월 말에 실시하였다. 시추작업 결과, 약 80m의 시추 코아가 성공적으로 회수되어 현재 러시아 이르쿠츠크 지구화학연구소에 보관중이다. 이 시추코아는 2004년 8월 중순경에 4개국 연구팀원들에 의해 공동으로 기재된 후에 분할될 계획이다. 분할된 시료는 국내로 운반되어 다양한 전문분야별 연구에 이용될 것이다. 한편, 제2차 시추작업은 2004년 12월에서 2005년 2월 사이에 실시될 계획이다. 수백만년에 이르는 장기간에 걸쳐 지구환경변화 기록이 보존되어 있는

  • PDF

Comparing the Analytical Results for the Determination of Weathered Diesel in Soils According to the Different Methods (적용된 분석방법 차이에 따른 토양 중 풍화 경유 함량 비교)

  • Lee Goon-Taek
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.3
    • /
    • pp.33-37
    • /
    • 2004
  • Soil samples used in this study were taken from the site at which diesel spill accident had occurred in 1995. It was confirmed that all of soil samples were contaminated with diesel which was going on weathering. The concentrations of diesel in soils were determined by Korea standard method revised in July 1999 (Method 1) and US EPA method 8015b (Method 2). Some additional soil samples were analyzed with Korea standard method revised in July 2002 (Method 3) to compare the accuracy and reproducibility with Method 2. The only four of forty-six samples were determined when the analysis carried out according to Method 1 while forty-three of forty-six samples had the value above criterion (2000mg kg$^{-1}$ ) according to Method 2. There were no significant differences between the results of the analysis by Method 2 and Method 3. Based on these results, Method 2 and 3 were more appropriate than Method 1 for the determination of weathered diesel in soil. Method 2 had almost equivalent accuracy and reproducibility to Method 3.