• 제목/요약/키워드: 시공 품질 등급

검색결과 10건 처리시간 0.021초

국내 골재 품질 현황 및 골재등급에 따른 콘크리트의 역학적 특성에 관한 연구 (Domestic Aggregate Quality Status and Mechanical Properties of Concrete According to Quality of Aggregate)

  • 민충식;박종호;정용;이재현;김용로;김효락
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.207-208
    • /
    • 2012
  • This study is aimed to utilize for basic material of concrete quality management through evaluate properties of fresh and hardened concrete with the aggregate quality. As a result, fine aggregate's slump change of between one grade was 8~82% and in case of coarse aggregate, slump change of between one grade was 2~22% on same mixing condition. The unit water for same workability condition, unit water was increased 16kg/㎥ with decreasing of one grade for fine aggregate and unit water was increased 5kg/㎥ with decreasing of one grade for coarse aggregate.

  • PDF

건설산업경쟁력 강화와 부실방지대책(안)

  • 한국주택협회
    • 주택과사람들
    • /
    • 54호통권71호
    • /
    • pp.185-206
    • /
    • 1996
  • 1.건설제도의 국제화와 경쟁기반 구축 $\bullet$건설산업을 기획$\cdot$설계$\cdot$시공$\cdot$감리$\cdot$사후관리 등 전 분야에 걸쳐 경쟁력 있는 산업으로 육성-기획$\cdot$설계$\cdot$시공$\cdot$감리$\cdot$유지관리 등 건설산업 전반에 관한 기본사항을 법제화-대규모 공사의 경우 발주자를 대신하여 건설공사의 기획$\cdot$설계$\cdot$발주$\cdot$감리$\cdot$시공관리 등 업무의 전부 또는 일부를 종합적으로 조정$\cdot$관리하는 $\lceil$건설사업관리$\rfloor$제도를 도입 $bullet$건설공사 $\lceil$현장실명제$\rfloor$도입을 통한 하도급제도의 정비-전문건설업자로부터 하도급, 위탁, 고용 등의 형태로 공사에 참여하는 현장근로자를 신고 받아 권익을 보호하고 시공책임도 부과하는 $\lceil$현장실명제$\rfloor$도입 $\bullet$공사완성보증제, 손해배상보증제도를 도입하고, 신용상태 $\cdot$시공능력에 따라 보증 요율 등을 차등화 하여 부실업체를 배제 $\bullet$건설공사관련 각종 계약서와 시방서 등 제기준을 정비하여 발주자$\cdot$시공자 등 건설주체간의 역할과 책임을 명확화$\bullet$건설분쟁을 신속하고 객관적으로 조정$\cdot$중재하기 위하여 $\lceil$건설분쟁중재원$\rfloor$으로 확대 개편 2. 건설인력의 육성과 고용안정$\bullet$경쟁력 제고의 관건인 우수인력 확보를 위하여 대학교육 제도의 개선을 포함한 건설 인력 수급대책을 추진 - 대학의 건설관련 학과 정원을 2000년까지 매년 일정규모로 증원하여 고급기술 인력을 배출 현재 50$\%$에 불과한 건설관련 국가기술자격자를 2000년에 70$\%$까지 제고 - 감리 등 전문인력을 양성하고, 선진외국 감리 회사를 활용하여 국내 업계와의 경쟁을 유도 $\bullet$건설현장의 최일선에서 품질을 담당하고 있는 건설기능공의 고용안정과 복지향상을 위한 획기적인 대책을 마련 - 건설기능공의 자긍심과 사회적 책임의식을 고취하기 위해 기능공이 여러 현장을 전전하여 근무하더라도 경력관리, 공제금 등의 합산 관리가 가능하도록 $\lceil$건설 근로자 복지카드$\rfloor$제도를 도입 *$\lceil$건실시연구단$\rfloor$을 구성$\cdot$구체적인 운영방안을 수립 - 건설 업체 실정에 맞는 현장위주의 기능검정제도 도입 $\cdot$자격증이 현장에서 요구되는 기능수준과 숙련도를 제대로 반영할 수 있도록 검정방법을 현장 실기위주로 개선하고 자격검정업무도 건설협회 등의 자격 검정능력을 향상시켜 위탁$\cdot$시행하는 방안을 검토 3. 공사시행기관의 전문성과 책임성 제고 $\bullet$시장이 개방되어 건설공사가 국제적인 관행에 따라 이루어질 것에 대비하여 시행기관에 계약$\cdot$공사관리 등 전문직공무원을 집중 교육하여 양성 $\bullet$ 조달청이 대행하여 공사계약을 하는 경우라도 설계변경은 발주기관이 자체적으로 할 수 있도록 허용 $\bullet$ 기술직 공무원의 기술향상을 위하여 관련 공무원의 확충, 해외연수, 현장교육 강화 등을 지속적으로 추진 $\bullet$ 충분한 사전조사를 거쳐 사업계획을 수립하도록 $\lceil$건설공사 시행절차$\rfloor$를 규정 $\bullet$ 공사기간 3년 이상의 공사에 대하여는 최대한 계속비사업으로 편성토록 계속비제도의 운영을 활성화 4. 건설현장의 품질관리체제 구축 $\bullet$ 현장배쳐플랜트 설치를 확대하여 레미콘의 품질관리를 일원화하고 현장에서 레이콘을 배합하는 건식공법을 채택 - 현장레미콘생산시설(B/P)설치 확대로 콘크리트 하자에 대한 책임한계 일원화 유도 - 레미콘 재료인 골재$\cdot$시멘트$\cdot$물을 공장에서 혼합하여 공급하는 현행 습식배합 대신에 물만을 현장에서 혼합하는 건식 배합방식을 도입 $\bullet$철강재$\cdot$철구조물의 품질을 보증하기 위하여 일정기술을 갖춘 공장에서만 제작토록 하는$\lceil$공장인증제$\rfloor$를 도입 - 제작시설과 품질관리 등을 심사하여 제작공장을 등급화하고 등급에 따라 철강재 등의 제작업무 범위를 차등화 $\bullet$시설물에 대하여도 시공업체가 제작공장을 등급화하고 등급에 따라 철강재 등의 제작업무 범위를 차등화 $\bullet$시설물에 대하여도 시공업체가 사후관리를 일괄 책임질 수 있도록 $\lceil$시공 및 유지관리 일괄계약제도$\rfloor$를 도입 - 대형교량$\cdot$소각로$\cdot$하수처리장 등 유지관리에 전문성이 요구되는 분야부터 시범적으로 도입 $\bullet$건설자재의 표준화$\cdot$정보화사업을 조속히 추진 5. 건설업체에 대한 지원 강화 $\bullet$일부 공공사업자의 경우 관행화되어 있는 대금일부의 어음 또는 채권지급방법을 단계적으로 축소 $\bullet$매월 감독이나 감리원의 기성확인에 의하여 시공자에게 공사대금을 직접 지급토록 하는 등 대금 지급절차를 간소화 6. 민간 건축물에 대한 안전확보 $\bullet$충실한 설계가 이루어지도록 제도를 개선 - 설계도서 작성기준을 제정하고 다중이용시설에 대하여는 건축심의단계에서 구조검토 등 설계심의를 의무화 $\bullet$대형다중이용시설에 대한 감리 강화 - 감리전문회사 수준의 감리체제로 전환하고 감리대가도 공공수준으로 인상하고 적용요율대로 지도$\cdot$감독 강화

  • PDF

중국과 한국 시멘트의 품질규정에 대한 비교 연구 (A Comparison Study on Quality Regulation of China and Korea Cement)

  • 배장춘;김호림;이백수;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.159-162
    • /
    • 2006
  • This study generally compared and investigated cement type and quality of China and Korea. Cement in Korea is divided into five such as ordinary, high early strength, moderate heat, low heat and sulfate resistance portland cement. However cement in China is divided into portland cement($P{\cdot}I,\;P{\cdot}II$) and ordinary portland cement($P{\cdot}O$) with admixture displacement ratio and it is again divided into 6 level and 7 level with 28 days compressive strength. In addition China classified cement into several standards, such as Mgo, SO3,, igloss, blame, setting time, stability, strength, alkali and sampling test. Therefore it should be careful to conclude so quickly without right understanding whether quality of China cement is bad or good. The better way to evaluate China cement is synthetically understanding a value engineering and consumer awareness.

  • PDF

거주자 사용성 확보를 위한 콘크리트 맨바닥 시공 품질 관리 기법 (Quality Control Techniques for Bare Concrete Floor Construction to Ensure Serviceability for Occupants)

  • 목지욱;최경석;김정진;석원균
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.19-20
    • /
    • 2023
  • The pre-qualification system related to floor impact noise is considered ineffective, and thus, the introduction of a post-verification system is being prepared. This is because the performance, which was notarized in the qualification test due to various reasons, was not uniformly confirmed on building construction fields. Industry practitioners perceive that this is due to the influence of factors such as the flatness, levelness and/or thickness of the floor. However, it is very difficult to confirm such facts in a short period of time on the fields, and since the practical application of technology to measure and evaluate quantitatively and the establishment of a system are insufficient, it cannot be said to be a problem that can be brought to the surface. In fact, even when considering the conventional measurement of the dynamic modulus of elasticity, measurements are performed under controlled variables, such as placing a 200mm×200mm buffer material on a flat test-floor. However, in the fields, it is common to lay down larger productions(for example, 900mm×600mm) on the bare floor where significant variables are not controlled, and to construct finishing layers corresponding to the pre-qualified floor system without separately confirming the realization of the dynamic modulus of elasticity in the field conditions. In this study, spatial information of the bare floor on the field was measured and evaluated through a laser scanner. Technical methods for assessing the smoothness, flatness, and thickness of construction surfaces were reviewed, providing key insights for grading the quality of construction based on these criteria. Through further detailed and thorough investigations, it is expected that results suitable for practical application and systematization will be derived.

  • PDF

주택성능등급 표시제도에 대응한 설계 가이드라인 (Design Guideline Corresponding to Housing Performance Grade Indication System)

  • 박현수;고광일;이찬식
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2006년도 정기학술발표대회 논문집
    • /
    • pp.396-401
    • /
    • 2006
  • 지속가능한 주택을 건설하고 품질이 양호한 주택재고를 위해 2006년 1월부터 주택의 설계에 관한 성능등급을 의무적으로 표시하도록 하는 "주택성능등급 표시제도"가 시행되었다. 이에 따라 수요자들은 주택성능을 용이하게 상호 비교하여 공동주택을 선택할 수 있고, 공급자 입장에서는 명확한 기준에 따라 정확한 평가를 받을 수 있을 것이다. 본 연구는 "주택성능등급 표시제도"의 시행에 대응하여 우수한 주택성능 등급을 획득하기 위해 합리적인 의사결정 지원도구로서 주택성능 등급별 설계 가이드라인을 제시하는 것을 목적으로 한다. 이를 위해 "주택성능등급 표시제도"의 성능평가항목 및 평가기준을 고찰하고 현재 적용되고 있는 국내${\cdot}$외 주택성능 관련 제도 및 기준을 분석하여 "주택성능 등급 표시제도"와의 관련성을 검토하였다. 주택성능 평가항목을 평가기준의 특징에 따라 4가지 범주로 분류한 후, 설계 가이드라인의 구성 체계를 정립하여 주택성능 등급별 설계 가이드라인을 제시하였다. 본 논문에서 제시한 설계 가이드라인은 주택건설사업의 추진 과정에서 계획, 설계 및 시공 담당자의 주택성능 등급 획득을 위한 합리적인 의사결정에 도움을 줄 것으로 기대된다.

  • PDF

표면파 기법에 의한 콘크리트 사방댐의 콘크리트 강도 등급 평가 (Quality Grading of Concrete Soil Erosion Control Dam in the Aspect of Unconfined Concrete Strength by Surface-Wave Technique)

  • 이창우;조성호;박기형;김민식;윤호중;하사눌
    • 한국산림과학회지
    • /
    • 제101권3호
    • /
    • pp.412-425
    • /
    • 2012
  • 산지계곡부의 토석류 유출을 저지하는 콘크리트 사방댐은 콘크리트의 재료 및 시공 불량, 콘크리트의 열화로 인한 내구성 저하, 국부적으로 발생한 균열 등의 이유로 인하여 사방댐의 일부 또는 전체 구조물이 붕괴되어 그 기능을 손실하는 경우가 있다. 본 논문에서는 이러한 콘크리트 사방댐의 구조적 문제점과 안전성을 파악하여 사전에 대책을 강구하고 효율적인 유지관리를 할 수 있는 방안을 제안하였다. 그 방안은 콘크리트 사방댐 구조물의 콘크리트 압축강도를 비파괴적으로 평가하여 품질등급을 평가하는 것으로, 등급평가 단계에서 비파괴 콘크리트 압축강도 평가를 위해 SASW 기법이라고 하는 표면파 기법을 도입하였다. 또한 SASW 기법을 콘크리트 사방댐의 안정성 가에 활용할 수 있도록 SASW 시험의 현장적용방안, 콘크리트 결함에 따른 자료분석 기법, 평가기준에 대한 제안등에 대한 연구를 수행하였다. 제안된 기법의 적용성과 신뢰성을 평가하기 위하여, 20년 이상 경과된 노후 콘크리트 방댐 5곳에 제안된 표면파 기법의 적용방안을 적용하여 보았다. 그 결과 콘크리트 사방댐의 여러 가지 콘크리트 함에 대해서도 SASW 기법에 의한 품질평가는 신뢰성 있게 수행될 수 있음을 확인할 수 있었고, 본 연구에서 제 안한 품질등급 평가 결과는 사방협회에서 실시한 사방댐 점검결과와 일치하는 결과를 제시하였다.

고품질 재활용 아스팔트 혼합물의 현장적용성에 대한 연구 (A Study on the Field Application of Superior Recycled Pavement of the Waste Asphalt)

  • 김지원;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제13권2호
    • /
    • pp.67-73
    • /
    • 2012
  • 폐아스콘은 순재료와 첨가제를 섞어 분쇄와 가열을 통하여 재활용될 수 있다. 본 연구에서는 고품질재생아스팔트(SRP)의 질을 향상시키기 위하여 Sasol 왁스와 폴리올레핀 탄성체를 이용하였다. 첨가제로써 중간층 및 표층용은 PG 70-22를 목표로 아스팔트량의 1.5%를 사용하였고, 중교통 표층용은 PG 76-22를 목표로 아스팔트량의 3% 개질제와 혼합물의 0.1%에 해당하는 셀룰로스 화이버를 첨가하였다. 두 혼합물은 마샬안정도시험, 간접인장강도시험, 잔류간접인장강도시험, 휠트래킹시험 등을 수행하였다. 시험결과는 KS F 2349와 GR F 4005의 기준을 만족하였으며, 고품질재생아스팔트는 중교통도로의 표층 및 기층재료로 사용이 적합하였다. 현재 약 13,000톤의 고품질재생아스팔트 혼합물이 서울 올림픽 도로에 현장시공 되었다.

접합 방법에 따른 하지철물 구조물의 거동에 관한 실험적 연구 (Experimental Study on the Behavior of Building Hardware with Joint Details)

  • 홍성욱;김승훈;백기열
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.190-198
    • /
    • 2018
  • 리모델링 시장이 커짐에 따라 품질이 우수한 건축물의 내장재 및 외장재들이 개발되고 있다. 개발된 내장재 및 외장재를 건축물의 구조체에 시공하기 위해서 구조체에 하지 철물을 설치하여야 한다. 건축물의 내장재 및 외장재 설치, 데크, 무대 및 마루 등의 시공 시 지지해주는 하부 구조물을 하지철물이라 한다. 하지 철물은 수평재와 수직재를 현장에서 용접 접합을 하여 구조체에 설치하는 방법이 주로 사용되었다. 일반적인 용접접합 방식의 시공은 용접 불씨에 의한 화재 발생으로 인명 및 재산 손실 문제와 전문용접공 부족으로 인한 비전문 용접공 시공에 따른 내구성 저하 문제 등이 발생하고 있다. 하지철물의 시공방법도 안전사고 및 시공의 용이성을 위하여 용접 접합 방법에서 무용접 접합 방법으로 개선되어지고 있다. 이는 화재예방 가설재와 소화장비 및 인원이 불필요하고 볼트조립으로만 시공이 가능하여 인건비 절감과 공기단축이 가능하다. 이에 용접을 사용하지 않는 무용접 하지 트러스 공법을 이용하여 접합부 거동을 실험하여 검증하고자 한다. 또한, 무용접 접합방법으로 시공 시 볼트 체결부분에서 틀어짐 현상이 발생하기도 하여 이를 보완하는 방법으로 각관, 유격방지 브라켓, 파스터, 홈볼트 체결을 통하여 일반 볼트접합인 각관, 화스너, 홈볼트 조립방법에서 좌우간의 틀어짐 현상을 방지하고 부재간의 미끄러짐 현상을 제어할 수 있도록 하는 시스템을 적용하여 접합부의 거동을 평가하고자 한다. 그 결과 무용접 접합방식의 하지철물 골조는 지진하중저항시스템에서 내진등급에 따라 요구되는 허용 층간변위각 0.01~0.02 보다 매우 큰 부재각까지 변형한 것으로 나타나 충분한 변형성능을 확보하고 있음을 알 수 있었다.

20년 이상 경과된 노후건축물의 단열재 성능평가에 관한 실험적 연구 (An Experimental Study on a Performance Evaluation of Internal Insulation of Buildings Over 20 Years Old)

  • 김현진;최세진
    • 한국건축시공학회지
    • /
    • 제19권6호
    • /
    • pp.539-547
    • /
    • 2019
  • 최근 국제사회는 지구온난화 방지를 위한 기후변화협약을 체결하고 건축물의 냉방 및 난방 에너지로 공급하는 화석연료 사용을 줄이고자 신축 또는 기존건물에 대한 녹색건축인증(G-SEED) 및 에너지효율등급, 건축물 에너지절약 설계기준 등을 일정조건 이상인 건축물에 의무적으로 적용하고 있다. 건물에 공급하는 에너지 공급을 줄이고 보온성을 향상시키는 건축자재로 단열재가 사용되고 있으며 신축건축물의 에너지절약 설계기준을 만족하는 건물외피 구성 재료 중 총 열 저항성의 90% 이상을 차지하고 있다. 그러나 기존건축물에 시공된 단열재의 경시변화에 대한 명확한 자료가 부족하여 건축물의 에너지성능 판단기준인 단위면적당 1차에너지 소요량 산정에 대한 의문점을 갖게 되었다, 이에 20년 이상 된 노후 건축물의 리모델링 현장에서 단열재(압출법,비드법)를 직접 채취하여 단열재성능을 비교·평가하였다. 실험결과, 압출법(XPS)은 생산초기 품질기준인 KS M 3808보다 열전도율은 48%, 압축강도는 36%가 저하되어 본래의 성능을 발휘하지 못함을 알 수 있었고, 비드법(EPS)의 경우 단열재 두께가 50mm인 경우 열전도율과 압축강도, 굴곡파괴하중 등이 생산초기 품질기준을 유지함을 알 수 있었다. 따라서 비드법의 경우 단열재 두께를 고려하여 현재의 단위면적당 1차 에너지소 요량을 기존대로 산정하고, 압출법의 경우는 단위면적당 1차 에너지소요량 산정시 보정계수를 적용해야 할 것으로 판단된다.

책임감리가 건설사업관리(CM)로 전환시 도입된 역량지수(ICEC)에 대한 도로건설기술자들의 인식 분석(II) - CM 용어와 ICEC 조정을 중심으로 - (An Analysis of Perceptions by Road Construction Engineers on ICEC Framework at the time of System Transition, from Responsibility Supervision to Construction Management (II) - Focused on CM Terminology & ICEC Coordination -)

  • 박효성;김낙석
    • 대한토목학회논문집
    • /
    • 제35권6호
    • /
    • pp.1357-1366
    • /
    • 2015
  • 본 연구(II)에서는 전 연구(I) 수행과정에 직무교육 훈련을 받고 있는 도로분야 건설기술자들이 질의했던 현안사항에 대하여 추가로 설문조사를 실시하고, 그 결과를 분석하여 미래지향적인 건설정책 대안을 도출하였다. "건설사업관리(CM) 용어가 2가지로 분리된 점에 대한 의견"을 묻는 질문에 응답자의 45%가 선진외국과 같이 '건설사업관리'로 단일화하자고 답했다. "CM전문가 육성 방안"에는 많은 응답자들이 민간교육기관에서 일정기간의 교육을 수료하면 CM전문가 자격을 얻을 수 있는 방안을 선호하였다. "설계 시공 및 품질관리 특급기술자의 역량지수(ICEC) 등급을 75점 이상에서 78점 이상으로 상향 조정(안)" 질문에는 '당초(안)처럼 75점 이상으로 하자'가 52%였다. "CM제도의 적용이 아직도 활성화되지 못하고 있는 이유"에는 응답자의 62%가 공공건설사업 발주기관 담당자들의 CM도입 의지가 부족하기 때문이라고 답했다. 건설사업의 아웃소싱을 기반으로 하는 CM제도의 활성화를 위해서는 국토교통부 본부의 조직 개편 방안이 선행되어야 한다.