• Title/Summary/Keyword: 시간 기준 제어

Search Result 372, Processing Time 0.023 seconds

Integrated Filter Circuits Design for Mobile Communications (무선 이동통신 단말에 응용 가능한 집적 필터회로 설계)

  • Lee, Kwang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.12
    • /
    • pp.991-997
    • /
    • 2013
  • A new frequency tuning scheme and a transconductor with a wide tuning range and low harmonic distortion is presented. This frequency tuning technique is based on the relationship between the time-constant and the elapsed times in charging a capacitor up to a certain level. Its structure is as simple as that of a conventional tuning scheme using a VCF(Voltage-Controlled Filter) and it does not need a pure sine wave but uses a CLK(Clock) pulse as a reference signal, which is easily obtained from on-chip system clocks or external X-tal oscillators. When a certain reference CLK is given, without complex capacitor arrays the pole frequency of the filter can be controlled continuously in the frequency domain. Simulation results are presented to confirm the operation of the proposed approach.

순간 동적 사용자 최적 통행배정모형을 이용한 교차로에서 좌회전 금지 효과분석

  • 김점산
    • Proceedings of the KOR-KST Conference
    • /
    • 1998.10a
    • /
    • pp.245-251
    • /
    • 1998
  • 좌회전 제어네는 크게 좌회전을 금지하는 적극적인 제어에서 좌회전 신호와 좌회전 차선의 디자인 및 차선 설정과 같은 비교적 소극적인 제어가 있다. 기존의 좌회전에 관한 많은 연구는 대부분 후자의 소극적인 제어를 통한 제어효과를 파악하는데 주로 관심을 두었다. 좌회전금지의 효과분석 방법론에는 크게 교차로 및 링크(Link)와 네트워크(Network)의 두가지 차원의 접근 방법이 있다. 교차로 및 링크(Link) 차원의 분석은 TRANSYT 7F, PASSER IV 등과 같은 가로망에서 신호시간을 최적화하는 모형과 NETSIM, COSIM과 같이 조건에 따라 실제 차량의 행태를 모사하는 시뮬레이션 모형 등에서 좌회전 신호현시를 주거나, 주지 않음으로써 전후의 변화를 관찰, 분석에 이용할 수 있다. 그러나, 이러한 접근방법은 개별교차로에서 현시운영에 따른 효과를 분석하기에는 용이할 지 모르나, 좌회전 금지에 따라 전환된 교통량을 합리적으로 처리하는데 문제를 가지고 있다. 이에 반해 네트워크(Network) 차원의 분석은 좌회전 금지에 따른 거시적 수요변화를 파악하여, 좌회전금지에 따라 전환된 교통량을 합리적으로 수용 할 수 있으며, 교차로 및 링크(Link) 차원의 분석기법과의 결합을 통해 개별교차로에서 현시운영에 따른 효과도 어느정도 예견할 수 있을 것으로 예상되지만, 이에 관련한 여구가 전무한 형편이다. 본 연구의 목적은 네트워크(Network) 차원에서 좌회전 금지에 따른 효과 분석 모형을 정립하고, 가상 네트워크에 적용 그 유효성을 검증하여, 지역 네트워크의 개별교차로에서 좌회전 금지의 도입에 대한 의사결정의 기준을 마련하는데 있으며, 이를 위한 구체적 연구 내용은 다름과 같다. 첫째, 순간 동작 사용자 최적 통행배정모형의 구조 및 특성 파악. 둘째, 기존 가로망 표현기법의 구조 및 특성파악. 셋째, 좌회전 금지에 따른 효과 분석을 위한 순간 동적 사용자 최적 통행배정모형의 구축. 넷째, 좌회전 금지에 따른 효과 분석을 위한 가로망 표현기법의 개발. 다섯째, 가상 네트워크에서 구축된 모형을 통한 교차로에서 좌회전 금지 효과분석

  • PDF

Analysis of a Three Phase PWM AC/DC Converter With Input Current Waveform and Power Factor Correction (입력 전류 파형과 역률 개선 제어기법에 의한 3상 PWM 컨버터 해석)

  • 이수흠;배영호;최종수;백종현
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.93-102
    • /
    • 1998
  • This paper describes to control system for AC to DC converter which has been widely used to power source in industrial factory and domestics. In this paper, three-phase PWM AC to DC Boost converter that operates with unity power factor and sinusodial input line currents is presented. The current control of this converter is based on the predicted current control strategy with fixed switching frequency and the line currents track to reference currents within one sampling time interval. By using this control strategy low ripples in the output current and the voltage as well as fast dynamic response are achieved with small dc link capacitance employed.ployed.

  • PDF

(The Speed Control of Induction Motor using PD Controller and Neural Networks) (PD 제어기와 신경회로망을 이용한 유도전동기의 속도제어)

  • Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.2
    • /
    • pp.157-165
    • /
    • 2002
  • This paper presents the implementation of the speed control system for 3 phase induction motor using PD controller and neural networks. The PD controller is used to control the motor and to train neural networks at the first time. And neural networks are widely used as controllers because of a nonlinear mapping capability, we used feedforward neural networks(FNN) in order to simply design the speed control system of the 3 phase induction motor. Neural networks are tuned online using the speed reference, actual speed measured from an encoder and control input current to motor. PD controller and neural networks are applied to the speed control system for 3 phase induction motor, are compared with PI controller through computer simulation and experiment respectively. The results are illustrated that the output of the PD controller is decreased and feedforward neural networks act main controller, and the proposed hybrid controllers show better performance than the PI controller in abrupt load variation and the precise control is possible because the steady state error can be minimized by training neural networks.

Application of a Fuzzy Controller with a Self-Learning Structure (자기 학습 구조를 가진 퍼지 제어기의 응용)

  • 서영노;장진현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.6
    • /
    • pp.1182-1189
    • /
    • 1994
  • In this paper, we evaluate the performance of a fuzzy controller with a self-learning structure. The fuzzy controller is based on a fuzzy logic that approximates and effectively represents the uncertain phenomena of the real world. The fuzzy controller has control of a plant with a fuzzy inference logic. However, it is not easy to decide the membership function of a fuzzy controller and its controlrule. This problem can be solved by designing a self-learning controller that improves its own contropllaw to its goal with a performance table. The fuzzy controller is implemented with a 386PC, an interface board, a D/A converter, a PWM(Pulse Width Modulation) motor drive-circuit, and a sensing circuit, for error and differential of error. Since a Ball and Beam System is used in the experiment, the validity of the fuzzy controller with the self-learning structure can be evaluated through the actual experiment and the computer simulation of the real plant. The self-learning fuzzy controller reduces settling time by just under 10%.

  • PDF

Proposal of Practical Reference-Model and It's Performance Improvement for PID Control (PID제어를 위한 실용적인 기준 모델 제안과 성능개선)

  • Hur, J.G.;Yang, K.U.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.66-72
    • /
    • 2007
  • This study proposed new method to decide the reference model necessary for design PID controller. In generally, control design problems using the reference model have the following two factors. One factor is that numerical model of the controlled system can be obtained extremely, and the other is that specification for the closed-loop dynamic performance is pure moderate. Therefore, the control design procedure is essentially based on the partial reference model matching which offers a reasonable method to simplify the design and the controller configuration under the controlled system uncertainty. ITAE(Integral of time-multiplied absolute error) performance index and Kitamori method etc. which were used a reference model method had a limit to settling time and rising time of reference model that it arrived to steady state response according to the controlled system. On this study, if it only knew peak time of overshoot and settling time by measurement signal of the controlled system, it can be made the reference model easily. We proposed new method to improve performance index of the reference model superior to existing reference model index and illustrate the numerical simulation results to show the effectiveness of proposed control method design.

  • PDF

Voltage Controlled Speed Controller of BLDC Motor Using Fuzzy Logic Control (Fuzzy Logic Control를 이용한 BLDC 모터의 전압 제어 속도 제어기)

  • Park, Jun-Ho;Han, Sang-Soo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.5
    • /
    • pp.481-486
    • /
    • 2018
  • DC motors are classified as DC motors with brush structure and BLDC motors without brush structure. Representing the speed control of the BLDC motor is the PI control. The speed control using the PI controller has a disadvantage that the response characteristic to reach the steady state is slow. Therefore in this paper, a voltage controlled speed controller using a Fuzzy Logic Controller (FLC), which has a short steady response time and usefulness of nonlinear control. The validity and usefulness of the proposed fuzzy speed controller are verified by simulation through Simulink of MATLAB program. Experiments were performed on the PI controller and the proposed fuzzy speed controller in three cases with reference speeds of 500rpm, 800rpm, and 1500rpm. Experimental results show that the proposed fuzzy controller has more 30% improved steady state speed response than PI controller.

Numerical Study on the Effect of Range Surrounding Environment on Detecting Time for Cooking Oil Fire in Kitchen (주방내 조리용 기름 화재 발생시 레인지 주변 환경이 감지 시간에 미치는 영향에 대한 수치해석적 연구)

  • Lee, Jin-Woo;Ko, Gwon-Hyun;Ryou, Hong-Sun;Jang, Yong-Jun;Jung, Woo-Sung
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.134-139
    • /
    • 2010
  • According to the "Yearbook of disaster response, fire safety and fire statistics (NEMA: National Emergency Management Agency)", approximately 34% of all fire is interior fire such as hotel, restaurant and residence and more than 53% of which is occurring in the kitchen. The evaluation of fire extinguishing system in the kitchen is performed in accordance with the "Korea Fire Equipment Inspection Standard (KOFEIS 0101-1)" which is using one environmental condition. However, only using one environmental condition is not enough to evaluate the performance of the automatic fire extinguisher in kitchen fire. So the study of fire detecting characteristic about various environmental condition needs. In this study, the numerical analysis is carried out about detecting time characteristic for various range's surrounding environment. As a result, it showed up to 100 s difference in the detection time depending on the position of the range. And detecting time also showed difference for on-off hood operation. From this results, it can be verify and improve the evaluation standard for the fire extinguishing system in kitchen fire.

A Development of dynamic Multi-labelling Vine Algorithm for Urban ATIS Application (도시부 ATIS 적용을 위한 다중 표지 덩굴망 알고리즘의 개발)

  • 박상준
    • Proceedings of the KOR-KST Conference
    • /
    • 1998.10a
    • /
    • pp.161-170
    • /
    • 1998
  • 기존에 건설된 교통시설의 운영효율을 극대화하기 위한 지능형 교통체계의 한 분야인 ATIS는 도로를 이용하는 통행자에게 편리성을 제공하는 동시에 도로를 효율적으로 운영할 수 있는 정보체계이다. ATIS 체계하에서 통행자에게 신뢰성 있는 정보를 제공하기 위해서는 교차로서의 회전에 의한 지체를 정확하게 반영함은 물론이고 실시간으로 변화하는 교통상황을 반영할 수 있는 동적인 최단경로 탐색 알고리즘이 요구된다. 하지만 기존에 발표된 동적인 최단경로 탐색 알고리즘은 회전에 대한 정보를 반영하지 못하며 정적인 최단경로 탐색 알고리즘은 회전에 대한 정보를 반영하지 못하며 정적인 탐색알고리즘 조차 회전에 대한 정보를 정확히 반영하지 못한다. 본 연구에서는 이러한 이유에서 알고리즘 내부에서 회전을 반영하기 위해 수정형 덩굴망 알고리즘의 표지기법을 이용하여 동적인 최단경로 탐색알고리즘을 개발하였다. 본 연구에서 개발한 동적 최단경로 탐색 알고리즘은 정적인 상태의 수정형 덩굴망 알고리즘에 시간에 따라 변화하는 교통상황을 반영하기 위해 시간에 대한 변수를 추가하였다. 이렇게 해서 알고리즘은 시간대별로 변화하는 통행시간을 고려하여 최단 경로를 탐색하게 되며 출발시점을 기준으로 표지를 설정하여 모든 앞선 시간에 대해 경로를 고려하도록 하였다. 매 단계에서 전 노드를 추적하여 회전에 관한 정보를 반영하도록 하였다. 따라서 본 연구에서 개발한 최단경로 탐색 알고리즘은 교차로에서의 회전에 대한 정보와 통행금지 등을 정확히 반영하며 실시간으로 변화하는 통행시간을 반영함으로써 신뢰성 있는 노선 정보를 ATIS를 이용하는 통행자들에게 제공하는데 활용될 수 있는 기법이다.적으로 세부적 차종분류로 접근한다.의 영향들을 고려함으로써 가로망 설계 과정에서 가로망의 상반된 역할인 이동성과 접근성의 비교가 가능한 보다 현실적인 가로망 설계 모형을 구축하고자 한다. 지금까지 소개된 가로망 설계모형들은 용량변화에 대한 설계변수의 형태에 따라 이산적 가로망 설계 모형과 연속적 가로망 설계모형으로 나뉘어지게 된다. 본 논문의 경우, 계산속도의 향상 측면에서는 연속적 가로망 설계 모형을 도입할 수 있지만, 이때 요구되는 도로용량이 이산적인 변수(차선 수)로 결정되어야만 신호제어 변수를 결정할 수 있기 때문에, 이산적 가로망 설계 모형이 사용된다. 하지만, 이산적 설계모형의 경우 조합최적화 문제이므로 정확한 최적해를 구하기 위해서는 상당한 시간이 소요되며, 경우에 따라서는 국부 최적해에 빠지게 된다. 이러한 문제를 극복하기 위해, 우선 이상적 모형의 근사화, 혹은 조합최적화문제를 위해 개발된 Simulated Annealing기법의 적용, 연속적 모형의 변수를 이산화하는 방법 등 다양한 모형들을 고려해 본 뒤, 적절한 모형을 적용할 것이다. 가로망 설계 모형에서 신호제어를 고려하기 위해서는 주어진 가로망에 대한 통행 배정과정에서 고려되는 통행시간을 링크통행시간과 교차로 지체시간을 동시에 고려해야 하는데, 이러한 문제의 해결을 위해서 최근 활발히 논의되고 있는 교차로에서의 신호제어에 대응하는 통행배정 모형을 도입하여 고려하고자 한다. 이를 위해서 지금까지 연구되어온 Global Solution Approach와 Iterative Approach를 비교, 검토한 뒤 모형에 보다 알맞은 방법을 선택한다. 차량의 교차로 통행을 고려하는 perf

  • PDF

A Study on Vulnerability Severity Evaluation Considering Attacker Skill Level Based on Time Series Characteristics (시계열 특성 기반의 공격자 기술 수준을 고려한 취약점 심각도 평가 방안 연구)

  • Seong-Su Yoon;Ieck-chae Euom
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.2
    • /
    • pp.281-293
    • /
    • 2023
  • Industrial control systems (ICS) are increasingly targeted by security incidents as attackers' knowledge of ICS characteristics grows and their connectivity to information technology expands. Vulnerabilities related to ICS are growing rapidly, but patching all vulnerabilities in a timely manner is challenging. The common vulnerability assessment system used to patch vulnerabilities has limitations as it does not consider weaponization after discovery. To address this, this study defines criteria for classifying attacker skill levels based on open information including operating technology and vulnerability information in ICS. The study also proposes a method to evaluate vulnerability severity that reflects actual risk and urgency by incorporating the corresponding attribute in the existing severity score calculation. Case studies based on actual accidents involving vulnerabilities were conducted to confirm the effectiveness of the evaluation method in the ICS environment.