• Title/Summary/Keyword: 시간간격신호

Search Result 240, Processing Time 0.027 seconds

Verification of Wavefront Inversion Scheme via Signal Subspace Comparison Between Physical and Synthesized Array Data in SAT Imaging (SAR Imaging에서 Physical Array와 합성 Array 신호의 Subspace 비교를 통한 Wavefront Inversion 기법 입증)

  • 최정희
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.4
    • /
    • pp.34-41
    • /
    • 1999
  • Unlike the traditional radar system, Synthetic Aperture Radar(SAR) system is capable of imaging a target scene to ceertain degree of cross-range resolution. And this resolution is mainly depends on the size of aperture synthesized. Thus, a good system model and inversion scheme should be developed to actually give effect of synthesizing aperture size, which in turn gives better cross range resolution of reconstructed target scene. Among several inversion schemes for SAR imaging, we used an inversion scheme called wavefront reconstruction which has no approximation in wave propagation analysis, and tried to verify whether the collected data with synthesized aperture actually give the same support as that with physical aperture in the same size. To do this, we performed a signal subspace comparison of two imaging models with physical and synthesized arrays, respectively. Theoretical comparisons and numerical analysis using Gram-Schmidt procedures have been performed. The results showed that the synthesized array data fully span the physical array data with the same system geometry. This result strongly supports the previously proposed inversion scheme valuable in high resolution radar imaging.

  • PDF

Range Walk Compensated Squint Cross-Range Doppler Processing in Bistatic Radar (바이스태틱 레이더에서 Range Walk이 보상된 Squint Cross-Range 도플러 프로세싱)

  • Youn, Jae-Hyuk;Kim, Kwan-Soo;Yang, Hoon-Gee;Chung, Yong-Seek;Lee, Won-Woo;Bae, Kyung-Bin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.11
    • /
    • pp.1141-1144
    • /
    • 2011
  • Range walk has been a major problem in achieving correct Doppler processing. This frequently occurs when range variation is severe just like in a bistatic radar or in high speed target scenario. This paper presents a range walk compensated range-Doppler processing algorithm applicable to the bistatic radar. In order for the compensation, a range-domain interpolation is applied for range compressed signal so that Doppler processing is performed along the evenly time-spaced range bins that contain target returns. Under a bistatic radar scenario, the proposed algorithm including a range domain pulse compression is mathematically described. Finally, the validity of the algorithm is demonstrated by simulation results showing the superiority of a SCDP(Squint Cross-range Doppler Processing) over an uncompensated Doppler processing.

The Fast Correlative Vector Direction Finder Conversion (직접 변환을 이용한 고속 상관형 벡터 방향탐지기)

  • Park, Cheol-Sun;Kim, Dae-Young
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.12 s.354
    • /
    • pp.16-23
    • /
    • 2006
  • This paper presents the development of the fast Direction Finder using direct conversion method, which can intercept for short pulse signal of less' than 1 msec. in RF Down Converter, and CVDF(Correlative Vector Direction Finding) algorithm, which estimates DoA (Direction of Arrival). The configuration and characteristics of direction finder using 5-channel equi-spaced circular array antenna are presented and the direct conversion techniques for removing tuning time using I/Q demodulator are described. The CRLB of our model is derived, the principles of 2 kind of CVDF algorithm are explained and their characteristics are compared with CRLB w.r.t the number of samples and spacing ratio. The RF Down Converter prototype using direct conversion method is manufactured, the 2 kind of CVDF algorithm are applied and their performance are analyzed. Finally it is confirmed the LSE based CVDF algorithm is better than correlation-coefficient based except for ambiguity protection capabilities.

SAW Filter Transmission Characteristics Design with Genetic Algorithm

  • Park, Kyu­-Chil;Kim, Seok­-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1767-1775
    • /
    • 2003
  • The SAW device is extensively used as a electro$.$mechanical band­pass filter in which a two­pairs of interdigital transducers are provided over the surface of the piezoelectric substrate. For the design requirement, the central frequency and the bandwidth of the passband, and the attenuation level of the stopband region are specified. The configuration is made so as to satisfy the specification given. The central frequency is mainly determined by the distance between the pair of the finger electrodes. The design is considered as an optimization problem with which the error norm, the distance between the desired characteristics and the calculated for a given model is to be minimized. The delta function model and the electrical equivalent circuit model are utilized to represent the SAW filter characteristics. Genetic algorithm is used for optimization in which apodization of the transducer fingers is chosen as a design variable.

A Study on Accuracy of Position Fixes Obtained by GPS at Three Fixed Stations (정점(定點)에 있어서 GSP의 측위정도(測位精度))

  • Cho, Eul-Je
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.3 no.2
    • /
    • pp.19-28
    • /
    • 1991
  • The United States has been developing a GPS(Global Positoning System), and now we can make use of it everywhere in the world. The author measured the usable time and took position fixes from three fixed stations in Japan in order to evaluate the positioning accuracy of GPS, firstly by the difference in the time of the year and, secondly by the difference in location between the stations in 1988. I was able to receive positioning signals from only 6 or 7 satellites, but in July 1991, 14 GPS satellites became available. The results obtained are summerized as follows: 1) The usable time was 7~9 hours from only 6~7 satellites. 2) In the case of the former, the time zone of position fixes varied with the time of the year and there were a little differences of the accuracy of position fixes except 3H(three dimensiomal high level positioning). In the case of the latter, there were not obvious locality differences in 3D(three dimensional positioning). But the positioning errors and number of data varied on each level in 2D(two dimensiomal positioning), although the positioning errors were smaller than 0.1 nautical mile. 3) Th standard deviations of Dep(departure) were larger than tat of D.lat(difference of latitude), and varied widely to the east and west. But the standard deviations were smaller than 100 meters.

  • PDF

Measurement of Regional Cerebral Blood Volume in Normal Rabbits on Perfusion-weighted MR Image (MR 관류강조영상에서 정상 가토의 국소 뇌혈류량 측정)

  • 박병래;예수영;나상옥;김학진;이석홍;전계록
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.100-106
    • /
    • 2000
  • Purpose : To evaluate the usefulness of cerebral blood flow measurement applied to perfusion weighted image with short-scan time single shot gradient echo-planar technique in measuring cerebral blood volume(rCBV) of normal rabbits. Materials and methods : With 2.1-3.6 kg weighted rabbits, image is acquired when they are in supine position in children positioner. Perfusion weighted image is acquired to 44 seconds per 1 second successively. After 4 seconds later, Gd-DTPA 2ml are injected into int. jugular vein with 2 ml per second and normal saline is also injected after that. Same technique is applied 2 times per 30 minites in same rabbit. After Image is obtained in two part of cerebral cortex at vertex, convexity, in one of basal ganglia with choosing about $3-5{\textrm{mm}^2}$ areas. Curve of signal intensity changes in time sequence is drawn. After this images are transmitted by PC and software IDL, regional cerebral blood volume is measured with imaging processing program made by us. Results : With 22 of 24 rabbits, satisfactory 1-2 signal intensity versus time curve is made. Cerebral blood capacity and contrast media stay time (ST) is measured in two cerebral cortex and basal ganglia refering in parietal cerebral cortex. Mean focal cerebral blood flow capacity ratio in cortex was $0.97{\pm}0.35$ and in basal ganglia, $0.99{\pm}0.37$, mean contrast media stay time in cortex was $9.83{\pm}1.63$ sec and in basal gaiglia, $9.42{\pm}1.14$ sec, but there was no statistically significant difference between two areas ($\rho$=0.05). Conclusion : In cerebral cortex and basal ganglia, there is no difference in mean focal blood volume and mean contrast stay time. Therefore, PWI is useful in cerebral blood flow and early diagnosis, prognosis of cerebral ischemic disease. Hereafter, it is helpful in analysing cerebral blood flow changes with comparison difference in rCBV between normal tissue and ischemic tissue, and that with DWI finding in infarcted patient.

  • PDF

Classification of Negative Emotions based on Arousal Score and Physiological Signals using Neural Network (신경망을 이용한 다중 심리-생체 정보 기반의 부정 감성 분류)

  • Kim, Ahyoung;Jang, Eun-Hye;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.21 no.1
    • /
    • pp.177-186
    • /
    • 2018
  • The mechanism of emotion is complex and influenced by a variety of factors, so that it is crucial to analyze emotion in broad and diversified perspectives. In this study, we classified neutral and negative emotions(sadness, fear, surprise) using arousal evaluation, which is one of the psychological evaluation scales, as well as physiological signals. We have not only revealed the difference between physiological signals coupled to the emotions, but also assessed how accurate these emotions can be classified by our emotional recognizer based on neural network algorithm. A total of 146 participants(mean age $20.1{\pm}4.0$, male 41%) were emotionally stimulated while their physiological signals of the electrocardiogram, blood flow, and dermal activity were recorded. In addition, the participants evaluated their psychological states on the emotional rating scale in response to the emotional stimuli. Heart rate(HR), standard deviation(SDNN), blood flow(BVP), pulse wave transmission time(PTT), skin conduction level(SCL) and skin conduction response(SCR) were calculated before and after the emotional stimulation. As a result, the difference between physiological responses was verified corresponding to the emotions, and the highest emotion classification performance of 86.9% was obtained using the combined analysis of arousal and physiological features. This study suggests that negative emotion can be categorized by psychological and physiological evaluation along with the application of machine learning algorithm, which can contribute to the science and technology of detecting human emotion.

Development of Data Acquisition System for Quantification of Autonomic Nervous System Activity and It's Clinical Use (자율신경계의 활성도 측정을 위한 Data Acquisition System의 개발 및 임상응용)

  • Shin, Dong-Gu;Park, Jong-Sun;Kim, Young-Jo;Shim, Bong-Sup;Lee, Sang-Hak;Lee, Jun-Ha
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.39-50
    • /
    • 2001
  • Background: Power spectrum analysis method is a powerful noninvasive tool for quantifying autonomic nervous system activity. In this paper, we developed a data acquistion system for estimating the activity of the autonomic nervous system by the analysis of heart rate and respiratory rate variability using power spectrum analysis. Materials and methods: For the detection of QRS peak and measurement of respiratory rate from patient's ECG, we used low-pass filter and impedence method respectively. This system adopt an isolated power for patient's safety. In this system, two output signals can be obtained: R-R interval heart rate) and respiration rate time series. Experimental ranges are 30-240 BPM for ECG and 15-80 BPM for respiration. Results: The system can acquire two signals accurately both in the experimental test using simulator and in real clinical setting. Conclusion: The system developed in this paper is efficient for the acquisition of heart rate and respiration signals. This system will play a role in research area for improving our understanding of the pathophysiologic involvement of the autonomic nervous system in various disease states.

  • PDF

Development and Evaluation of Smart Roundabout Using Connected Vehicle (Connected Vehicle을 이용한 Smart Roundabout의 개발과 평가)

  • Kim, Hoe Kyoung;Lee, Young Bin;Yoon, Chil Yong;Oh, Yun Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.243-250
    • /
    • 2014
  • Modern roundabouts referred to as relatively safer and more efficient traffic facility than the signalized intersections have been recently deployed and operated and accordingly more research efforts to improve its safety and efficiency have been made so far. This paper introduces a new traffic information system named as Smart Roundabout coupled with Connected Vehicle technique like Vehicle-to-Roadside communication, which has not been attempted before and evaluates its performance with a microscopic simulation model, VISSIM. The proposed system functions to collect driving information of circulating vehicles in the roundabout such as location, speed, critical headway, etc. and help approaching vehicles decide whether to enter the roundabout with an on-board equipment instrumented in the individual vehicle on the basis of calculated gap acceptance of interest. This new system is expected to secure more safety and increase the capacity of the modern roundabout.

Spike Rejection Method for Improving Altitude Control Performance of Quadrotor UAV Using Ultrasonic Rangefinder (초음파 거리계를 이용하는 쿼드로터 무인항공기의 고도 제어 성능 향상을 위한 스파이크 제거 기법)

  • Kim, Sung-Hoon;Choi, Kyeung-Sik;Hong, Gyo-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.3
    • /
    • pp.196-202
    • /
    • 2016
  • In this paper, a stationary wavelet transform method is proposed for improving the altitude control performance of quadrotor UAV using an ultrasonic rangefinder. A ground tests are conducted using an ultrasonic rangefinder that is much used for vertical takeoff and landing. An ultrasonic rangefinder suffers from signal's spike due to specular reflectance and acoustic noise. The occurred spikes in short time span need to be analyzed at both sides time and frequency domain. It was known that stationary wavelet transform is the transferring solution to the problem occurred by down sampling from DWT also more efficient to remove noise than DWT. The analyzed spikes of the ultrasonic rangefinder using a stationary wavelet transform and experimental results show that it can effectively remove the spikes of the ultrasonic rangefinder.