• Title/Summary/Keyword: 시각피로도

Search Result 143, Processing Time 0.026 seconds

A Study on 3D Stereoscopic Video Production (3D 입체영상 제작방법에 관한 연구)

  • Choi, Young-Geun;Kim, Jong-Chan;Kim, Jong-Il;Kim, Chee-Yong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.360-362
    • /
    • 2010
  • In this paper, the next generation of digital video media attention to the 3D digital stereoscopic images can be most easily produced and minimize the cost for technology that can be made three-dimensional imaging technique, one of the leaf anaglyph research on methods through the low cost of the optimal representation of the three-dimensional stereoscopic images, and enjoy watching, a technique is proposed.

  • PDF

Depth Acquisition Techniques for 3D Contents Generation (3차원 콘텐츠 제작을 위한 깊이 정보 획득 기술)

  • Jang, Woo-Seok;Ho, Yo-Sung
    • Smart Media Journal
    • /
    • v.1 no.3
    • /
    • pp.15-21
    • /
    • 2012
  • Depth information is necessary for various three dimensional contents generation. Depth acquisition techniques can be categorized broadly into two approaches: active, passive depth sensors depending on how to obtain depth information. In this paper, we take a look at several ways of depth acquirement. We present not only depth acquisition methods using discussed ways, but also hybrid methods which combine both approaches to compensate for drawbacks of each approach. Furthermore, we introduce several matching cost functions and post-processing techniques to enhance the temporal consistency and reduce flickering artifacts and discomforts of users caused by inaccurate depth estimation in 3D video.

  • PDF

Comparison and Analysis for the Effects of Functional Progressive Addition Lenses on Binocular Vision of University Students (기능성 누진가입도렌즈가 대학생들의 양안시기능에 미치는 영향 비교 분석)

  • Kim, Chang Jin;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.105-116
    • /
    • 2010
  • Purpose: To analyze and compare differences between single vision lenses and functional progressive addition lenses and improvement to binocular visual function wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses (EYE-T, Chemilens Co., Korea, ADD 0.750) for 2 months. Objective refraction, corrected visual acuity at distance and near, near point of convergence, near point of accommodation, accommodative facility, phoria at distance and near were measured. And subjective satisfaction was investigated by using a questionnaire designed to fatigue, comfort, discomfort, overall satisfaction and preference. Results: Functional progressive addition lenses were better than single vision lenses at near point of convergence and accommodation, accommodative facility. Exo phoria measured at distance with single vision and functional progressive addition lenses. Exo phoria measured at near with functional progressive addition lenses was higher than that with single vision lenses. As a survey, the satisfaction was increased in questions related near work. However, single vision lenses were preferred in distance test of overall satisfaction, easy 10 adapt, lime to adapt. A survey showed thai preference of functional progressive addition lenses were increased 75.00% to 81.26% for near work, 50.00% to 65.63% for visual fatigue, 47.75% to 50.00% for visual comfort and 31.25% to 46.88% for overall comfort. Conclusions: Comparing between single vision lenses and functional progressive addition lenses, binocular visual function related near work, subjective satisfaction and preference was improved after wearing functional progressive addition lenses. This study suggested that functional progressive addition lenses were useful for long time near work.

Evaluation of sleep quality and stress response in patients requiring dental prosthetic treatment (치과보철치료를 요하는 환자에서의 수면질과 스트레스 반응 평가)

  • Jeon, Hye-Mi;Jung, Kyoung-Hwa;Choi, Na-Rae;Song, Jae-Min;Lee, So-Hyoun;Kim, So-Yeun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.181-189
    • /
    • 2021
  • Purpose: The purpose of this study is to investigate the stress response and sleep state of the new patients who visit the hospital for prosthodontic treatment due to tooth loss to make reference to further treatment direction. Materials and methods: Examinations, consultations, and surveys were conducted on 236 patients (94 males, 142 females, and 24-86 years old), who newly registered at the department of prosthodontics at Pusan national university hospital, for 2 years from 2018. The number of remaining teeth, edentulous arch, possibility of mastication, and future prosthetic treatment directions were recorded. The visual analogue scale (VAS), stress response inventory (SRI) and Insomnia severity index (ISI) were used as tools to measure patient's subjective discomfort, stress response, and sleep status. Results: Among the entire prosthodontic patient group, the average value of 'fatigue' was significantly higher among the 7 items of SRI, and the value of 'aggression' was significantly lower (P<.001). There are a significant difference between the edentulous and full dentition in the oral discomfort value measured by VAS (P=.004). In cases where less than 20 teeth remain, mastication is impossible, and patients who are planning treatment with removable prostheses, VAS value and 'depression' and 'fatigue' values in SRI were higher than those in the reverse case (P<.05). The patients showed severe level in VAS value have high value of 'tension', 'somatization', 'depression', 'fatigue'and 'frustration'in SRI than non-serious patients (P<.05). Clinical insomnia occurred in 11.4% of all patients, and women had significantly lower sleep quality than men (P=.044). Patients with insomnia showed significantly higher scores on the VAS value and all 7 SRI items than those of normal sleepers (P<.05). Conclusion: The new prosthetics had high 'fatigue' value among the 7 items of SRI. The oral condition, number of residual teeth and mastication function and clinical insomnia affected oral discomfort and the stress response.

Development of Novel Assistive Device for Improving Usability of BVM (인공호흡기 사용성 향상을 위한 새로운 보조기구 개발)

  • Jeon, Gang-Hyun;Park, Yong-Jai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.420-426
    • /
    • 2020
  • In this study, an assistive device for BVM (Bag Valve Mask) was developed. When emergencies occur, rescuers must perform artificial respiration within four minutes utilizing suitable BVM. If not, the patient can suffer serious damage within their brain and body systems. The rescuer must execute artificial respiration until the patient arrives at the hospital. In the process of artificial respiration, the rescuer can feel fatigued in their forearm muscles, particularly those who may have smaller hands or weaker muscle strength. Many products have been developed to solve these problems, but these products are difficult to market and commercialize because of their volume, size, and difficulty of use. In this paper, the BVM assistive device that has been previously manufactured was improved, and an attempt was made to devise a new method that reduces the burden on the user. The BVM assistive device can be divided into three-parts: a head part for compressing the air bag, which can control the amount of air; the body part for coupling with BVM; and finally, the handle that can rotate for better use on various postures of patients. Throughout the experiment, the assistive device could inject an equal amount of air into the patients. As a result, the rescuer could feel less fatigue and inject a suitable amount of air to emergency patients during artificial respiration.

Changes in Accommodative Function after VDT Work (VDT 작업 후의 조절기능 변화)

  • Seo, Eun-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.285-291
    • /
    • 2012
  • Purpose: This study was conducted to research any effect on visual function related to accommodation by VDT work. Methods: The refraction power, accommodative lag, accommodative facility, relative accommodation, amplitude of accommodation and blink rate were measured before and after VDT work for 2 hours on 48 university students (16 males and 32 females), without abnormal accommodative function and systemic and ocular disease, who had never undergone corrective eye surgery. All examinations were performed with distant refraction, and a survey was conducted on the items related to subjective symptoms of VDT syndrome. Results: After 2 hours of VDT work, refractive power increased by 0.23 D, the amount of change in accommodative lag were $0.17{\pm}0.42D$ in the right eye and $0.23{\pm}0.47D$ in the left eye (t=2.26, p=0.03). There were statistically significant differences. Both the accommodative facility and relative accommodation and amplitude of accommodation were decreased after work. However, blink rate were increased. After VDT work, 33.4% of the subjects showed subjective symptoms of asthenopia and 33.3% of them showed shoulder pain. Conclusions: As a result, the accommodative lag increased in response to the two hours of VDT work, and overall accommodative functions were decreased. In addition, as symptoms of providing visual strain, asthenopia showed the most prominent subjective symptoms.

3D Displays: Development and Validation of Prediction Function of Object Size Perception as a Function of Depth (3D 디스플레이: 깊이에 따른 대상의 크기지각 예측함수 개발 및 타당화)

  • Shin, Yoon-Ho;Li, Hyung-Chul O.;Kim, Shin-Woo
    • Journal of Broadcast Engineering
    • /
    • v.17 no.2
    • /
    • pp.400-410
    • /
    • 2012
  • In recent years, 3D displays are used in many media including 3D movies, TV, mobile phones, and PC games. Although 3D displays provide realistic viewing experience as compared with 2D displays, they also carry issues such as visual fatigue or size distortion. Focusing on the latter, we developed prediction function of object size perception as a function of object depth in 3D display. In Experiment 1, subjects observed 3D square of a fixed size of varying depth, and manipulated 2D square to make it as large as the 3D square. Conversely, in Experiment 2, subjects observed 2D square of a fixed size, and manipulated 3D square of varying depth to make it as large as the 2D square. In both Experiments 1 and 2, we found that size perception of 3D square linearly changed depending on depth of the square, and the linear relationship between depth and size was identical in both experiments. The predictive regression function, which predicts object size perception based on object depth, obtained in this research will be very useful in the creation of 3D media contents.

Screen Disparity and Size Perception Function of Various 3D Stimuli (양안시차에 따른 다양한 3D 자극의 크기지각 예측함수 개발)

  • Park, JongJin;Li, Hyung-Chul O.;Kim, ShinWoo
    • Journal of Broadcast Engineering
    • /
    • v.18 no.1
    • /
    • pp.66-76
    • /
    • 2013
  • Although there has been much advance in the development of 3D displays of various purpose, 3D contents are not yet so used as expected in those displays. One well-known obstacle in the enjoyment of 3D contents is visual fatigue, but another major issue is image distortion of 3D contents. In the previous research, Shin, Li, & Kim (2012) reported systematic linear relationship between screen disparity and size perception of a simple object whose retinal size was constant across different disparities. In this research, we intended to generalize the previous finding by using various 3D stimuli in the test of the relationship between screen disparity and size perception of those stimuli. Consistent with previous findings, our data indicated that size perception linearly changes as a function of screen disparity and the linearity was observed in all stimuli types we used in this research. We described the empirical relationship between screen disparity and size perception in the form of prediction function for size perception in which visual angle is the predictor. This function will be very useful in the creation of 3D contents as one can make reasonable predictions on the to-be-perceived size of an object being filmed using screen disparity of their camera setting.

The Clinical Study on Spectacle Wearers of Highschool Students (고등학생 안경착용자의 착용상태에 관안 임상적 연구)

  • Kim, Sang-Kyun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2004
  • The purpose of this study is to survey spectacle wearers's way of thinking through the questionaire and to investigate their wearing conditions through fitting conditions, the pantascopic angle, vertex distance, the coincidence of vertical and horizontal distance between optical center of the lens and pupillary distance of the eye in random selected 150 ametropic corrective wearers in the age of 17 to 19. The results are as follows : 1. The most popular causes of physical complaints in the ex-wearing spectacle are frame pressure(34.0%), slipping forward(30.0%) and most popular visual complaints are blur vision(30.0%) and asthenopia(20.0%). 2. The most common physical or visual complaints in the present wearing spectacle are slipping forward(30.0%), pressure (50.0%), color(10.0%). 3. Myopic glasses wearers accounted for 56.7% of the subjects, the others were compound myopic astigmatism. In 60% of the subjects' binocular diopter did not coincide. 4. In the pantascopic angle of the both eyes coincide in 66.7% of the subjects. The average of pantascopic angle is $10.07^{\circ}$. 5. In the vertex distance of the both eyes coincided in 65.3% of the subjects. the he average of vertex distance is 13.6 mm. 6. Among 150 eyes with monocular, the vertical distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG 915 that is tolerance of ophthalmic dispensing in German Standards in 82 eyes (54.6%). 7. Among 150 eyes with monocular, the horizontal distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG915 that is tolerance of ophthalmic dispensing in German Standards in 86 eyes(57.3 %).

  • PDF

A Study on the Document viewer optimized for VR environment (VR 환경에 최적화 된 문서 뷰어에 관한 연구)

  • Joo, Yong-Ho;Kim, Sang-Mok;Cho, Ok-Hue
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.5
    • /
    • pp.139-145
    • /
    • 2021
  • Through this study, we intend to study user satisfaction in order to verify whether there is a need for full-scale research, development and commercialization of document viewers in a VR environment. VR content consists of realistic 3D graphics and 360-degree video, and provides a synesthesia experience and immersion. We developed and tested a VR document viewer prototype that can utilize this concept as a document viewing system. It can act as a viewer that provides an interactive viewing environment according to the user's body interaction and the direction of the field of view, and it can be said that the feature of VR document viewer is that it can draw the user's high level of immersion and concentration when using the viewer. The developed prototype was tested in a test group consisting of 100 VR experiences and device owners for about 1 hour and 3 days a day, and then a questionnaire survey in the form of a fixed selection question was conducted. This study is a prototype study of a document viewer suitable for a virtual reality environment, and can lead to a sense of immersion when reading a document, and suggest a new document viewer direction that is effective for visual fatigue and visual perception of the document.