• Title/Summary/Keyword: 승온

Search Result 398, Processing Time 0.024 seconds

Cure Kinetics of Diglycidyl ether of bisphenol A-Methylene dianiline-Succlnonitrile System (Diglycidyl ether of bisphenol A/Methylene dianiline/Succinonitrile계의 경화반응 속도론)

  • Jo, Seong-U;Sim, Mi-Ja;Kim, Sang-Ok
    • Korean Journal of Materials Research
    • /
    • v.2 no.4
    • /
    • pp.257-262
    • /
    • 1992
  • The cure kinetics of a diglycidyl ether of bisphenol A (DGEBA) with 4, 4'-methylene dianiline (MDA) added succinonitrile was studied through the dynamic run method by applying the data to the Kissinger equation which analyses the effect of the heating rate on the temperature at maximum reaction rate using Differential Scanning Calorimetry (DSC) analyzer in the range of 3$0^{\circ}C$-35$0^{\circ}C$. In the DGEBA/MDA system with SN, the activation energy ($E_a$) and the pre-exponential factor (A) were calculated. From these results, the rate constants (k) were obtained according to the different SN contents.

  • PDF

A study on the Temperature Profile with combustion conditions change for the Optimum drive of Plate type Hydrogen Generation Sytem (평판형 수소생산시스템의 최적 운전조건을 위한 연소조건별 분위기 온도 연구)

  • Heo, Su-Bin;Park, Jae-Min;Yoon, Bong-Seock;Lee, Do-Hyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.238-243
    • /
    • 2012
  • The purpose of this study is to search the temperature-rise time conditions for adequate reforming temperature region of hydrogen generation system. And we measured theexhaust gas at the exit of that system in order to know the combustion state of hydrogen generation system's combustor. We found the optimum condition of heat supply and temperature-rise time at well burned state. And the results were nearly same when the reactants were entered to each reactors. We will further consider the effects of temperature change near the exothermic reactors and find out hydrogen yield through reforming experiment.

Prediction of Heat-Up Time of the Glass Plate by IR Heaters in an LCD-Panel Cleaning Process (LCD 패널 세척공정에서 원적외선 히터에 의한 유리기판 승온시간 예측)

  • Kim, Yun-Ho;Ji, Tae-Ho;Kim, Seo-Young;Rhee, Gwang-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.526-533
    • /
    • 2006
  • The prediction of heat-up time of an LCD glass plate in LCD glass pre-treatment process has been implemented in the present study. Firstly, the analytical solution for one-dimensional radiation heat transfer from IR heaters to a LCD glass plate is obtained. When the surface temperature of the IR heaters is set at 473 K, the heat-up time of LCD glass to averaged temperature of 383K is 28 seconds. In addition, a three dimensional full CFD analysis using STAR-CD is implemented in an effort to consider the effect of 3-D heat loss through the furnace walls. From the results of the 3-D CFB analysis, the heat-up time increases up to 32.5 seconds under the same conditions. When the IR heater temperature in creases up to 573 K, the heat-up time decreases to 12 seconds for the one-dimensional analytical solution and to 13.5 seconds for the 3-D CFD analysis, respectively.

Combustion Characteristics of Domestic Anthracite with High-Pressure TGA (가압열중량분석기를 이용한 국내무연탄의 연소특성 해석)

  • 류호정;한근희;진경태;이계봉;최정후
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.243-252
    • /
    • 2001
  • Combustion characteristics of domestic anthracite coal were observed by high-pressure thermogravimetric analyzer with variation of pressure (1~16 atm) and heating rate (15, 20, $25^{\circ}C$/min) with non-iso-thermal method (temperature range : 25~100$0^{\circ}C$). Measured combustion reaction rate increased with increasing pressure. This result could be explained by the fact that the activation energy of coal combustion decreased with increasing pressure. Reaction order of coal combustion determined by Freeman and Carroll$^{[11]}$ method linearly increased from 1.04 to 1.30 and activation energy decreased from 47.37 to 14.42 Kcal/mol as pressure increased from 1 to 16 attn.

  • PDF

Characteristics of Pore Development for Activated Carbon Fiber from Polyacrylonitrile(II) -Activation- (PAN계 활성탄소 섬유의 세공발달 특성(II) -활성화-)

  • Park, Jong-Hak;Cho, Byung-Rin
    • Applied Chemistry for Engineering
    • /
    • v.4 no.1
    • /
    • pp.113-124
    • /
    • 1993
  • Thermogravimetric analysis of copolymer of acrylonitrile(95%) and methyl acrylate(5%) have been carried out to investigate the activation under $H_2O$(30%) -$N_2$atmosphere at various heating rates. The kinetic equation [$f=1-\exp(-a{\Delta}T)^b$] which was derived on the basis of the nonisothermal activation process of carbon fiber in the $H_2O$(30%)-$N_2$system showed good agreement with experimetal results. The pore volume upon conversion was in good agreement with the model of theoretical pore volume. The pore structures of the activated carbon fiber were influenced by the heating rate, activation temperature and internal-external conversions.

  • PDF

Cure Kinetics and Dynamic Mechanical Properties of an Epoxy/Polyoxypropylene Diamine System (에폭시/폴리옥시프로필렌 디아민계의 경화 반응속도 및 동역학 특성 분석)

  • Huang, Guang-Chun;Lee, Jong-Keun
    • Polymer(Korea)
    • /
    • v.35 no.3
    • /
    • pp.196-202
    • /
    • 2011
  • The cure kinetics of a bisphenol A epoxy resin and polyoxypropylene diamine curing agent system are investigated in both dynamic and isothermal conditions by differential scanning calorimetry (DSC). In dynamic experiments, the shift of exothermic peaks obtained at different heating rates is used to obtain activation energy of overall cure reaction based on the methods of Ozawa and Kissinger. Isothermal DSC data at different temperatures are fitted to an autocatalytic Kamal kinetic model. The kinetic model is in a good agreement with the experimental data in the initial stage of cure. A diffusion effect is incorporated to describe the later stage of cure, predicting the cure kinetics over the whole range of curing process. Also, dynamic mechanical analysis is performed to evaluate the storage modulus and average molecular weight between crosslinkages.

A Study on the Strength Characteristics of Model Ice for Warm-up Time during Model Ice Preparation (모형빙 생성 시 승온 시간에 따른 모형빙의 강도 특성 연구)

  • Jeong, Seong-Yeob;Ha, Jung-Seok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.57 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • Understanding the strength characteristics of model ice is an important issue for model testing in an ice model basin to estimate the ship performance in ice. In particular, the mechanical properties of the model ice including elastic modulus, flexural strength and compressive strength are key consideration factors. In order to understand the characteristics of the model ice during warm-up phase at KRISO's ice model basin, the strength properties are tested in this study. The infinite plate-bending method, in-situ cantilever beam test and ex-situ uniaxial compressive test are conducted to determine the strength properties of model ice. The strength characteristics of the model ice are then analyzed in terms of the warm-up phase and seasonality. These results could be valuable to quality control of the model ice characteristics in KRISO's ice model basin and to better understand the variations in strength properties during the ice model tests.

Comparison Between Two Solar Absorption Cooling System Using Single Effect and Single Effect/Double Lift Cycle (일중효용 사이클과 일중효용/2단승온 사이클을 이용한 태양열 흡수식 냉방시스템의 비교)

  • 정시영;이상수;조광운;백남춘
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.267-276
    • /
    • 2000
  • A numerical study has been carried out to find out the optimal design condition of a solar absorption cooling system. The system was composed of solar collectors and an absorption chiller with LiBr/water The System performance with commercial single effect(SE) cycle and a new single effect/double lift(SE/DL) cycle utilizing low temperature hot water was calculated and compared. It was found that the required solar collector area grew exponentially as the overall heat loss coefficient of solar collectors increased. For instance, the required area for cooling capacity of 1 USRT was $17m^2$ if heat loss coefficient was 4 W/$m^2\;cdot\;K$. If heat loss coefficient was doubled($8\;W/m^2\;cdot\;$K), the required collector area was increased by 6 times($100m^2$) .It was also found that the SE-cycle as the heat loss coefficient of solar collectors increased. Generally, a SE/DL-cycle seems to be more advantageous than a SE-cycle if loss coefficient of solar collector is greater than 4 W/$m^2\;cdot\;K$.

  • PDF

A study on preparation of activated carbon from waste tire (폐타이어로부터 활성탄 제조에 관한 연구)

  • Kim, Jin-Uk;Lim, Ki-Hyuk;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.947-953
    • /
    • 2012
  • In this study we investigated the manufacturing method for the activated carbon using the char from the pyrolysis of waste tire. The physical activation method using the steam in the fixed-bed quartz reactor was used for preparation of activated carbon. The primary experiment parameters are the activation temperature, activation time, heating rate, and the injection quantity of active agent. From the results of pore distribution of activated carbon, the micropore which was made in $850^{\circ}C$ of activation temperature, $5^{\circ}C$/min of heating rate, and 3 hours of activation time was developed in biggest quantity, and mesopore and macropore were developed in the biggest quantity too. The optimum conditions for producing the activated carbon using the pyrolysis residue were $850^{\circ}C$ of activation temperature, 3 hours of activation time, $5^{\circ}C$/min of heating rate, and 3 g $H_2O/char-g{\cdot}hr$ of active agent through this study. The produced activated carbon in these conditions showed that the potentiality of utilization as activated carbon because the BET specific surface area was $517.6m^2/g$ and total pore volume was $0.648cm^3/g$.

The Effect of the Crystalline Phase of Zirconia for the Dehydration of Iso-propanol (이소프로판올의 탈수반응에서 지르코니아 촉매의 결정상에 따른 영향)

  • Sim, Hye-In;Park, Jung-Hyun;Cho, Jun Hee;Ahn, Ji-Hye;Choi, Min-Seok;Shin, Chae-Ho
    • Korean Chemical Engineering Research
    • /
    • v.51 no.2
    • /
    • pp.208-213
    • /
    • 2013
  • Zirconium hydroxide was synthesized by varying the aging time of the zirconyl chloride octahydrate at $100^{\circ}C$ in aqueous solution and the resulting hydroxides were calcined at $700^{\circ}C$ for 6 h to obtain the crystalline $ZrO_2$. The materials used in this study were characterized by differential thermal analysis (DTA), X-ray diffraction (XRD), $N_2$-sorption, transmission electron microscopy (TEM), $NH_3$ temperature-programmed desorption ($NH_3$-TPD), $CO_2$-TPD and iso-propanol TPD analyses to correlate with catalytic activity for the dehydration of iso-propanol. The pure tetragonal $ZrO_2$ phase was obtained after 24 h aging of zirconium hydroxide and successive calcination at $700^{\circ}C$. The increase of aging time showed the production of smaller particle size $ZrO_2$ resulting that the higher specific surface area and total pore volume. $NH_3$-TPD results revealed that the relative acidity of the catalysts increased along with the increase of aging time. On the other hand, the results of $CO_2$-TPD showed the reverse trend of $NH_3$-TPD results. The best catalytic activity for the dehydration of iso-propanol to propylene was shown over $ZrO_2$ catalyst aged for 168 h which had the highest $S_{BET}$ ($178\;m^2\;g^{-1}$). The catalytic activity could be correlated with high surface area, relative acidity and easy desorption of iso-propanol.