• Title/Summary/Keyword: 습도상승

Search Result 111, Processing Time 0.029 seconds

Studies on the Storage Stability of Traditional Andong sikhe using Lactobacillus delbreuckii (Lactobacillus delbreuckii를 이용한 전통안동식혜의 저장 안정성)

  • Choi, Cheong;Son, Gyu-Mok;Woo, He-Sob
    • Journal of the Korean Society of Food Culture
    • /
    • v.7 no.4
    • /
    • pp.329-338
    • /
    • 1992
  • This study was attempted aimed to prepare of Andong sikhe by pure culture inoculation and to improve storage stability by the addition of stabilizers to the product. Lactobacillus delbreuckii was selected for pure culture inoculation in the fermentation. The effect of stabilizers on the sedimentation, sensory evaluation and viscosity of Sikhe were investigated during the fermentation of traditional Andong Sikhe stored at $4^{\circ}C$ Morphological characteristics of Sikhe were determined by scanning electromicrograpy. Among the stabilizers added to the traditional Andong sikhe Na-alginate was found to be best stabilizers. When the product was evaluated by the sensory panel, the addition of stabilizers up to 0.1% level actually increased the acceptability of the product, while the concentration of more than 0.2% stabilizers affected the acceptability of the negatively. Sikhe added Na-carboxymethyl cellulose and Na-alginate showed highest viscosity on the 2nd day of fermentation, while homogenized Andong sikhe with Carrageenan showed the highest peak in viscosity on the first day of fermentation. Lactic acid bacterial count reached to $3.2{\times}10^8/ml$ after 20 days of storage. The surface and cross section of rice was observed by scanning electron microscope. As the fermentation proceeded holes on the surface increased, and nearly empty cell wall remained at the later stage of fermentation. Use of pure cultured inoculum of L. delbreuckii supported the rapid build up of the lactic acid bacteria and consequently the whole process of the fermentation was shortened. The acceptability and product quality were improved by use of L. delbreuckii inoculum.

  • PDF

Ecophysiological Interpretations on the Water Relations Parameters of Trees(IX) - Measurement of the Transpiration Rate by the Heat Pulse Method in a Quercus mongolica Stand - (수목(樹木)의 수분특성(水分特性)에 관(關)한 생리(生理)·생태학적(生態學的) 해석(解析)(IX) - Heat pulse법(法)을 이용(利用)한 신갈나무임분(林分)의 증산속도(蒸散速度) 측정(測定) -)

  • Han, Sang Sup;Kim, Sun Hee
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.2
    • /
    • pp.288-299
    • /
    • 1996
  • This is the basic study to investigate the amount of transpirational water loss in thrifty mature Quercus mongolica stand by the heat pulse method. The differences of heat pulse velocity by direction and depth, differences of heat pulse velocity by dominant, codominant and suppressed trees, diurnal changes of heat pulse velocity due to the change of leaf water potential, vapor pressure deficit and radiation, and sap flow path way in sapwood by dye penetration were measured in stems. Finally the amounts of daily and annual transpiration in stand were calculated by the heat pulse velocity. The results obtained were summarized as follows : 1. Relationship between heat pulse velocity(V) and sap flow rate(SFR) was obtained as a equation of SFR=1.37V. 2. The sap flow rate was high in the order of dominant, codominant, and suppressed trees. The daily heat pulse velocity changed with radiation, temperature and vapor pressure deficit. 3. The heat pulse velocity showed the similar diurnal variation as the leaf water potential change. 4. The heat pulse velocity showed the highest value in May(4.0cm/hr in average), the lowest one in July(2.9cm/hr in average). 5. The heat pulse velocity in the same stem presented the highest value in the northern direction, medium in western, and the lowest in southern and eastern. 6. The heat pulse velocity in stem was highest in 0.5cm, medium in 1.0cm, and lowest in 1.5cm depth from the surface of stem. 7. The sap flow path way in stem showed sectorial straight ascent pattern in four sample trees. 8. The amount of sap flow(SF) was presented as a equation of $SF=1.37A{\cdot}V$(A: the cross-sectional area of sapwood, V: heat pulse velocity), and especially SF was larger in dominant tree than codominant and suppressed trees. 9. The amount of daily transpiration was 5.6ton/ha/day, and its composition ratio was 72% at day and 28% at night. 10. The amount of stand transpiration per month was largest in May(168ton/ha/month), lowest in July(125ton/ha/month). The amount of stand transpiration per year was 839ton/ha/year.

  • PDF

Detection of flash drought using evaporative stress index in South Korea (증발스트레스지수를 활용한 국내 돌발가뭄 감지)

  • Lee, Hee-Jin;Nam, Won-Ho;Yoon, Dong-Hyun;Mark, D. Svoboda;Brian, D. Wardlow
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.8
    • /
    • pp.577-587
    • /
    • 2021
  • Drought is generally considered to be a natural disaster caused by accumulated water shortages over a long period of time, taking months or years and slowly occurring. However, climate change has led to rapid changes in weather and environmental factors that directly affect agriculture, and extreme weather conditions have led to an increase in the frequency of rapidly developing droughts within weeks to months. This phenomenon is defined as 'Flash Drought', which is caused by an increase in surface temperature over a relatively short period of time and abnormally low and rapidly decreasing soil moisture. The detection and analysis of flash drought is essential because it has a significant impact on agriculture and natural ecosystems, and its impacts are associated with agricultural drought impacts. In South Korea, there is no clear definition of flash drought, so the purpose of this study is to identify and analyze its characteristics. In this study, flash drought detection condition was presented based on the satellite-derived drought index Evaporative Stress Index (ESI) from 2014 to 2018. ESI is used as an early warning indicator for rapidly-occurring flash drought a short period of time due to its similar relationship with reduced soil moisture content, lack of precipitation, increased evaporative demand due to low humidity, high temperature, and strong winds. The flash droughts were analyzed using hydrometeorological characteristics by comparing Standardized Precipitation Index (SPI), soil moisture, maximum temperature, relative humidity, wind speed, and precipitation. The correlation was analyzed based on the 8 weeks prior to the occurrence of the flash drought, and in most cases, a high correlation of 0.8(-0.8) or higher(lower) was expressed for ESI and SPI, soil moisture, and maximum temperature.

Ecophysiological Interpretations on the Water Relations Parameters of Trees(VII) - Measurement of Water Flow by the Heat Pulse Method in a Larix leptolepis Stand - (수목(樹木)의 수분특성(水分特性)에 관(關)한 생리(生理)·생태학적(生態學的) 해석(解析)(VII) - Heat pulse법(法)에 의한 낙엽송임분(林分)의 수액류속(樹液流速) 계측(計測) -)

  • Han, Sang Sup;Kim, Sun Hee
    • Journal of Korean Society of Forest Science
    • /
    • v.82 no.2
    • /
    • pp.152-165
    • /
    • 1993
  • This is the basic study in order to know the amount of transpirational water loss in a Larix leptorepis stand by a heat pulse method. Especially this study has been measured and discussed the diurnal and seasonal trends of heat pulse velocity by changes of radiation, temperature and humidity, differences of heat pulse velocity by direction and depth in stem, differences of heat pulse velocity by dominant, codominant and suppressed trees, diurnal change of heat pulse velocity by change of leaf water potential, sap flow path way in sapwood by dye penetration and amount of daily and annual transpiration in a tree and stand. The results obtained as follows : 1. Relation between heat pulse velocity(V) and sap flow rate(SFR) was established as a equation of SFR=1.37V($r=0.96^{**}$). 2. The sap flow rate presented in the order of dominant, codominant and suppressed tree, respectively. The daily heat pulse velocity was changed by radiation, temperature and vapor pressure deficit. 3. The heat pulse velocity in individual trees did not differ in early morning and in late night, but had some differed from 12 to 16 hours when radiation was relatively high. 4. The heat pulse velocity and leaf water potential showed similar diurnal variation. 5. The seasonal variation of heat pulse velocity was highest in August, but lowest in October and similar value of heat pulse velocity in the other months. 6. The heat pulse velocity in stem by direction was highest in eastern, but lowest in southern and similar velocity in western and northern. 7. The difference of heat pulse velocity in according to depths was highest in 2.0cm depth, medium in 1.0cm depth, and lowest in 3.0cm depth from surface of stem. 8. The sap flow path way in stem showed spiral ascent turning right pattern in five sample trees, especially showed little spiral ascent turning right in lower part than 3m hight above ground, but very speedy in higher than 3m hight. 9. The amount of sap flow(SF) was presented as a equation of SF=1.37AV and especially SF in dominant tree was larger than in codominant or suppressed tree. 10. The amount of daily transpiration was 30.8ton/ha/day and its composition ratio was 83% at day and 17% at night. 11. The amount of stand transpiration per month was largest in August(1,194ton/ha/month), lowest in May (386ton/ha/month). The amount of stand transpiration per year was 3,983ton/ha/year.

  • PDF

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

Suggestions for improving data quality assurance and spatial representativeness of Cheorwon AAOS data (철원 자동농업기상관측자료의 품질보증 및 대표성 향상을 위한 제언)

  • Park, Juhan;Lee, Seung-Jae;Kang, Minseok;Kim, Joon;Yang, Ilkyu;Kim, Byeong-Guk;You, Keun-Gi
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.1
    • /
    • pp.47-56
    • /
    • 2018
  • Providing high-quality meteorological observation data at sites that represent actual farming environments is essential for useful agrometeorological services. The Automated Agricultural Observing System (AAOS) of the Korean Meteorological Administration, however, has been deployed on lawns rather than actual farm land. In this study, we show the inaccuracies that arise in AAOS data by analyzing temporal and vertical variation and by comparing them with data recorded by the National Center for AgroMeteorology (NCAM) tower that is located at an actual farming site near the AAOS tower. The analyzed data were gathered in August and October (before and after harvest time, respectively). Observed air temperature and water vapor pressure were lower at AAOS than at NCAM tower before and after harvest time. Observed reflected shortwave radiation tended to be higher at AAOS than at NCAM tower. Soil variables showed bigger differences than meteorological observation variables. In August, observed soil temperature was lower at NCAM tower than at AAOS with smaller diurnal changes due to irrigation. The soil moisture observed at NCAM tower continuously maintained its saturation state, while the one at AAOS showed a decreasing trend, following an increase after rainfall. The trend changed in October. Observed soil temperature at NCAM showed similar daily means with higher diurnal changes than at AAOS. The soil moisture observed at NCAM was continuously higher, but both AAOS and NCAM showed similar trends. The above results indicate that the data gathered at the AAOS are inaccurate, and that ground surface cover and farming activities evoke considerable differences within the respective meteorological and soil environments. We propose to shift the equipment from lawn areas to actual farming sites such as rice paddies, farms and orchards, so that the gathered data are representative of the actual agrometeorological observations.

Effects of Fermented Soybean Extracts and Rain-shelter System on Growth and Disease Occurrence of 'Niitaka' Pear (발효 콩 추출물과 비가림 시설이 '신고' 배나무의 생육과 병해충 발생에 미치는 영향)

  • Lim, Kyeong-Ho;Kim, Byeong-Sam;Kim, Deok-Hyeon;Son, Jang-Hwan;Park, Shin;Cho, Dong-Ho;Jung, Seok-Kyu;Choi, Hyun-Sug
    • Korean Journal of Organic Agriculture
    • /
    • v.24 no.3
    • /
    • pp.557-570
    • /
    • 2016
  • Growth of 6-year old 'Niitaka' pear (Pyrus pyrifolia Nakai) trees and control of insect and disease occurrences were compared between fermented soybean extracts and rain-shelter system for two years. Foliar application of fermented soybean extracts was applied at 6 times as a pre-experiment in the open-field in 2013, with a rain-shelter system in 2014. Fermented soybean extract treatment increased foliar concentrations of approximately 0.46% T-N, 0.17% K, 0.19% Ca, and 0.06% Mg in 2013 compared to the control, with similar macro-nutrients between the control and soybean extract treatment observed in 2014. Rain-shelter system increased foliar concentrations of T-N, Ca, and Mg compared to the open-field. There were no significantly different between the control and soybean extract treatment for number of leaves per fruit, leaf dry weight, phytotoxicity, and completed shoot growth on August during the two years. Rain-shelter system increased leaf dry weight and did not affect phytotoxicity in the leaves. Fruit quality parameters were mostly similar to control and soybean extract treatment for two years, with higher fruit firmness observed for soybean extract treatment. Rain-shelter system advanced 4 days of harvest dates, and increased approximately 7.0 ton fruit yield per ha, 20 g mean fruit weight, and fruit soluble solid contents compared to open-field in 2014. Soybean extract treatment little suppressed occurrence of disease and insect on the leaves and fruits in both years. Rain-shelter system increased occurrence of Venturia nashicola on the leaves and to 63.8% of Gymnosporangium asiaticum on the fruits in 2014. Strong winds and storms in May elevated relative humidity in the rain-shelter system and caused high infection of the disease occurrence, requiring for an additional green control method. Soybean extract treatment little affected tree growth and would have initiated for a long-term study to evaluate tree physiological characteristics. Rain-shelter system improved fruit productivity and advanced harvest dates, which could have been more effective facility at a Thanks Giving Day between middle and end of September.

Study on Ventilation Efficiency of a Mechanically Ventilated Broiler House­(I)Summer Season (강제환기식 육계사내의 환기효율성 조사연구­(I)하절기)

  • 이인복;정문성;유병기;전종기;김경원;이승기
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.103-112
    • /
    • 2003
  • In this study, the distributions of internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were systematically measured at a mechanically ventilated broiler houses during summer season, with local weather data. The analysis was focused on the suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens and decrease of productivity In the mechanically ventilated broiler house, the difference between measured and recommended air temperatures(suitability) was 10.4C in maximum during the summer time. The difference of air temperature in the house between day and night was $8.7^{\circ}C$ in maximum. And maximal hourly range of internal air temperature at 0.4m height from the floor was $3.7^{\circ}C$ suggesting it maintained thermal uniformity in the broiler house. The $NH_3$ and dust concentrations were pretty low because ventilation was fully performed. The air speed at chicken location was measured 2.2m/s and 1.7m/s, respectively without and with chicken existence.

  • PDF

Development of Control Algorithm for Greenhouse Cooling Using Two-fluid Fogging System (이류체 포그 냉방시스템의 제어알고리즘 개발)

  • Nam, Sang-Woon;Kim, Young-Shik;Sung, In-Mo
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.138-145
    • /
    • 2013
  • In order to develop the efficient control algorithm of the two-fluid fogging system, cooling experiments for the many different types of fogging cycles were conducted in tomato greenhouses. It showed that the cooling effect was 1.2 to $4.0^{\circ}C$ and the cooling efficiency was 8.2 to 32.9% on average. The cooling efficiency with fogging interval was highest in the case of the fogging cycle of 90 seconds. The cooling efficiency showed a tendency to increase as the fogging time increased and the stopping time decreased. As the spray rate of fog in the two-fluid fogging system increased, there was a tendency for the cooling efficiency to improve. However, as the inside air approaches its saturation level, even though the spray rate of fog increases, it does not lead to further evaporation. Thus, it can be inferred that increasing the spray rate of fog before the inside air reaches the saturation level could make higher the cooling efficiency. As cooling efficiency increases, the saturation deficit of inside air decreased and the difference between absolute humidity of inside and outside air increased. The more fog evaporated, the difference between absolute humidity of inside and outside air tended to increase and as the result, the discharge of vapor due to ventilation occurs more easily, which again lead to an increase in the evaporation rate and ultimately increase in the cooling efficiency. Regression analysis result on the saturation deficit of inside air showed that the fogging time needed to change of saturation deficit of $10g{\cdot}kg^{-1}$ was 120 seconds and stopping time was 60 seconds. But in order to decrease the amplitude of temperature and to increase the cooling efficiency, the fluctuation range of saturation deficit was set to $5g{\cdot}kg^{-1}$ and we decided that the fogging-stopping time of 60-30 seconds was more appropriate. Control types of two-fluid fogging systems were classified as computer control or simple control, and their control algorithms were derived. We recommend that if the two-fluid fogging system is controlled by manipulating only the set point of temperature, humidity, and on-off time, it would be best to set up the on-off time at 60-30 seconds in time control, the lower limit of air temperature at 30 to $32^{\circ}C$ and the upper limit of relative humidity at 85 to 90%.

Effect of Shading Methods on Growth and Fruit Quality of Paprika in Summer Season (파프리카 여름재배시 차광방법이 생육과 과실특성에 미치는 영향)

  • Ha, Jun Bong;Lim, Chae Shin;Kang, Hyo Yong;Kang, Yang Su;Hwang, Seung Jae;Mun, Hyung Su;An, Chul Geon
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.419-427
    • /
    • 2012
  • This study was carried out to investigate the effect of two shading methods, shading agent spray on the glasshouse and internal shading screen treatment, on the growth and fruit quality of paprika (Capsicum annuum L. 'Cupra' and 'Coletti') in summer season cultivation. In the shading agent treatment, a commercial shading agent diluted with water at a ratio of 1 : 4 was sprayed on the roof of a glasshouse. In the internal shading screen treatment, a 10~20% shaded screen was used during the day time when the sun radiation was greater than $700W{\cdot}m^{-2}$. Compared to the unshaded control, photosynthetic photon flux density (PPFD) decreased in the greenhouse in the shading agent (SA) and shading screen (SS) treatments by 20% and 30%, respectively. Lower air temperatures and higher relative humidities were observed in the SA than in both the control and the SS treatment. Time to reach the break point of humidity deficit $8g{\cdot}m^{-3}$ was 2 hours late in the SA than in both the control and the SS treatment. Compared to control, both the SA and the SS treatments showed lower instantaneous temperatures of leaf, fruit, and flower by $2^{\circ}C$, $5^{\circ}C$ and $3^{\circ}C$, respectively. There were no differences in number of branches, stem diameter, and leaf size among treatments although both shading treatments promoted plant height in both cultivars. Botrytis infection ratio declined with the SA treatment by 14.7% in 'Cupra' and 22.1% in 'Coletti' as compared to that in the control. Shading increased fruit size in both cultivars, whereas no differences were observed in the number of locules and thickness of fruit tissue among treatments. Shading treatment increased mean fruit weight by a range of 10 to 15 g per fruit, while it decreased soluble solids contents as compared to that in the control. Similar Hunter values were observed among treatments, while fruit firmness increased slightly in shading treatments. Compared to the control, shading treatments improved marketable fruits by 11.7~22.6% and increased the number of fruits per plant by 4~9.2 in both 'Cupra' and 'Coletti'. The results of this study indicate that shading agent application on the roof of glasshouse would be one of the most effective options to reduce heat stress imposed on the paprika crop in summer cultivation, resulting in improved crop growth and fruit yield.