• Title/Summary/Keyword: 습도변화

Search Result 808, Processing Time 0.028 seconds

Non-Stationary Stress Analysis of Repaired Concrete Structures due to Hygral Transient Condition (대기 습도변화에 따른 콘크리트 보수체의 비정상적인 습도응력 조사)

  • 윤우현
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.3
    • /
    • pp.157-166
    • /
    • 1997
  • The object of this study was invest, igat, ing the failure phenomenon in the contact zone of rcpnired concrete structures due to the external climate change(hygral transient condition). This study was carrie out by calculating the non-stationary moisture and stress distribution in the repaired concrete structures with the cement mortar. In this analysis, main variables were the overlay thickness (Do=0.5-2.5cm). and the pre-wetting time(tc= l-5days). and the cxtcrnal 1.~1ative humidity(Ho=50-80%). The results show that the minimum overlay thickness and the minimum pre-wetting time are necessary to k e ~ p compressive stresses in the contact zone for a relative humidity.

Humidity Sensor using Polyvinylpyrrolidone-Coated Mach-Zehnder Interferometer in Planar Lightwave Circuit (폴리비닐피롤리돈이 코팅된 마하젠더 간섭계 기반의 평판형 광도파로 습도센서)

  • Kim, Ju Ha;Kim, Myoung Jin;Jung, Eun Joo;Hwang, Sung Hwan;Lee, Woo Jin;Choi, Eun Seo;Rho, Byung Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.251-255
    • /
    • 2013
  • In this paper, the characteristics of a humidity sensor implemented by Mach Zehnder Interferometer (MZI) in a Planar Lightwave Circuit (PLC) have been designed and demonstrated. The humidity outside is detected with polyvinylpyrrolidone (PVP) coated on the etched arm of the MZI. The length of the etched arm is 10 mm and the PVP was coated by dip-coating into the etched region. As the refractive index of the PVP changes with the surrounding humidity, the PVP-coated humidity sensor presented changes in the interferogram depending on RH (Relative Humidity) around the PLC. The measured results show that the proposed humidity sensor works successfully in the range of 30% to 80% of RH.

Micro humidity sensor with poly imide sensitive layer (폴리이미드를 감지막으로 한 마이크로 정전용량형 습도센서)

  • Shin, P.K.;Cho, K.S.;Park, G.B.;Yuk, J.H.;Park, J.K.;Im, H.C.;Ji, S.H.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1898-1899
    • /
    • 2005
  • 반도체 집적회로 공정에서 사용되는 폴리이미드 포토레지스트(P12723, Dupont)를 감습막으로 사용하는 마이크로 습도센서 소자를 제작하였다. 마이크로 습도센서는 실리콘 웨이퍼 기판 위에 $SiO_2$ 박막을 건식열산화 공정으로 제작하고, Al 박막을 포토리소그라피 공정으로 패터닝 한 IDT (Interdigital Transducer)를 전극 위에 폴리이미드 포토레지스트를 공정변수를 다양하게 조절하면서 감습막으로 제작하였다. 폴리이미드 감습막은 스핀코팅법으로 제작하였으며, 회전수를 조절하여 두께를 변화시켰다. 완성된 마이크로 습도센서 소자의 상대습도 변화$(10{\sim}90% RH)$에 따른 정전용량 값 변화를 항온항습조 내에서 다양한 온도에서 HP4192A Impedance Analyzer를 사용하여 조사함으로써, 폴리이미드 포토레지스트를 사용하는 마이크로 정전용량형 습도센서의 제작 가능성을 검토하였다. 폴리이미드 정전용량형 마이크로 습도센서는 다양한 인가 전원 주파수에서 기준 센서로 사용된 상용 Vaisala Hygrometer와 유사한 감습특성 및 응답특성을 보였다.

  • PDF

The variation of optical pass length between incident and reflective beam in multilayer thin film (다층박막에서의 입사광과 반사광의 광로정변화)

  • 김문환;최영규
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.515-520
    • /
    • 2002
  • The variation of the optical pass length between incident and reflective beam in a multilayer thin film reflection mirror is investigated. This variation is caused mainly by environmental parameters around the optical system, such as the air pressure, temperature, humidity and $CO_2$concentration. In this paper, a new method for measuring optical pass length variation is proposed. This optical pass length is measured against the above parameters by experiment. From the experimental results, it is clarified that the optical pass length is mostly effected by humidity changes.

Compressive Strength Reduction Characteristics of Linerboard as Influenced by Temperature and Humidity (온도 및 습도 변화에 따른 라이너원지의 압축강도 열화에 관한 연구)

  • 이준호;김수일;하영선
    • Food Science and Preservation
    • /
    • v.6 no.3
    • /
    • pp.303-307
    • /
    • 1999
  • Compressive strength reduction characteristics of 4 different linerboards(SC, KA, SK and IK) as influenced by temperature and humidity were investigated by ring crush test. No significant effect of temperature on the reduction of compressive strength was found for samples prepared at 5$^{\circ}C$ and 30$^{\circ}C$. At the relative humidity of 66 percents, IK linerboard showed the lowest reduction of the compressive strength. At the relative humidity of 93 percents, KA linerboard lost 40 percents of its initial compressive strength while SK linerboard lost its strength up to 56 percents. The result indicated that KA linerboard was the most cost effective and material with the highest compressive strength among tested linerboards.

  • PDF

Analysis of Thermal Performance of Ardisia Species Used for Improvement of Indoor Environment (실내환경 개선을 위한 Ardisia속 식물의 열 성능 평가)

  • Lee, Na Young;Han, Seung Won;Joo, Na Ri;Lee, Jong Suk
    • FLOWER RESEARCH JOURNAL
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • This study investigated the changes of indoor thermal environment by Ardisia species planted in indoor space. Three Ardisia species (Ardisia japonica, Ardisia crenata and Ardisia pusilla) were used in this study and differences of temperature and relative humidity were ascertained in an empty chamber with and without plants. In high temperatures over $24^{\circ}C$, Ardisia species cooled down chamber more as compared to the control without plants, but there were no significant differences among Ardisia species. Ardisia crenata showed high relative humidity of $57.3{\pm}3.1%$ during most of the day time and $60.8{\pm}2.5%$ at low temperatures. However, Ardisia japonica and Ardisia pusilla showed $54.7{\pm}1.18%$ and $52.5{\pm}2.4%$, respectively, on the average, and they maintained comfortable relative humidity during most of the day time. When the setting temperature was decreased from 28 to $26^{\circ}C$, Ardisia species showed 7.5~13.6 times greater cooling efficiency as compared to the control without plants, and at low temperatures the chamber without plants showed higher themal energy than the chamber with plants. Ardisia species were effective on cooling down the temperature at high temperatures and they showed a tendency to maintain proper temperatures at low temperatures.

Finite element simulation of drying process for ceramic electric insulators (세라믹 애자 건조공정의 유한요소 시뮬레이션)

  • 정준호;금영탁;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.3
    • /
    • pp.347-352
    • /
    • 1999
  • The finite element formulation and simulation of drying process for ceramic electric insulators are investigated. The heat and moisture movements in green ceramics caused by the interaction of temperature gradient, moisture gradient, conduction, convection and evaporation are considered. The variations of temperature and moisture not only change the volume but also induce the hygro-thermal stress. The finite element formulation for solving the temperature and moisture distributions as well as the associated hygro-thermal stresses is derived. Using the computer code developed, the drying process of a ceramic electric insulator is simulated. Temperature distribution, moisture distribution, hygrothermal stress and deformed shape during the drying process are predicted.

  • PDF

Leakage cerrent characteristics of 154kV porcelain insulators with various ambient humidity (습도 변화에 따른 154kV급 송전용 자기애자의 누설전류 특성연구)

  • Oh, Chung-Seok;Lee, Young-Jo;Ryu, Cheol-Hwi;Lee, Bang-Wook;Choi, Gwang-Beom;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1461_1462
    • /
    • 2009
  • 송전선로에 설취된 애자들은 지속적인 전기적 기계적 스트레스에 노출되어 있기 때문에 여러 환경적 요인으로 인해 애자 표면의 열화가 가속된다. 이와 같은 애자의 표면 열화는 dryband를 형성하게 되고 지속적인 애자 표면상의 dryband와 누설 전류 증가의 상호작용은 애자의 섬락를 일으키는 원인이 된다. 이러한 연구의 결과 고전압용 애자로 유입되는 누설 전류는 애자 열화의 정도를 평가할 수 있는 매우 중요한 parameter임을 알 수 있다. 따라서 고전압용 애자의 누설전류를 분석하고 취득하여 애자의 열화 평가 및 이로 인해 발생할 수 있는 결함 애자의 검출에 대한 연구가 절실히 요구되고 있다. 본 논문에서는 고전압용 애자 중 자기애자의 습도변화에 따른 누설전류 특성을 조사하기 위해 자체 제작한 실험 챔버, power transformer, 전류센서, 오실로스코프, PC등으로 구성된 실험 시스템을 구축하였고, 데이터 분석을 위한 S/W로서 LabView를 사용하였다. 그에 따른 실험결과로서 다양한 습도변화(30%~90%)의 경우 정상 애자련과 결함 애자를 포함한 애자련의 누설전류 데이터를 취득하여 본 연구에서 제시한 알고리즘을 통해 분석함으로써 정상 애자 내의 결함 애자 포함 여부를 판별하고 다양한 습도 변화시에 정상 애자련과 불량 애자련의 특징을 볼 수 있었다.

  • PDF

Experimental Study on Capacity Variation of Paving Materials with TiO2 in Wet Condition (광촉매 이산화티타늄(TiO2)을 혼합한 도로 포장재의 습윤 조건에서의 성능 변화에 관한 실험적 연구)

  • Seo, Dawa;Yun, Tae Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.5
    • /
    • pp.49-55
    • /
    • 2016
  • This study aims to present the practical Nitrogen monoxide (NO) removal capacity of cement mortar with Titanium dioxide ($TiO_2$) which is one of the paving materials by considering the environment of pavement in urban areas. NO removal capacity test under designated conditions of humidity of inflow gas and the test with variation of the degree of saturation of specimen were conducted. In the test for humidity, dry specimen is subject to the test and NO removal ratio was observed. Humidity-NO removal ratio curve is a log normal distribution in shape, and the maximum NO removal ratio appears at specific humidity. NO removal capacity test relying on the degree of saturation was carried out with wet specimen to reflect the unsaturated pavement by rainfall and domestic sewage. Wet specimen presents less NO removal capacity than dry specimen and the recovering evolution of NO removal capacity follows evaporation. Moreover, $TiO_2$ under the specific depth of specimen hardly contributes to NO removal capacity.

Analysis for Temperature and Relative Humidity of Showcase in Exhibition Hall Operated Intermittent Air Conditioning (간헐공조 전시관내 유물 진열장의 온·습도 환경 분석)

  • Lee, Sun Myung;Lim, Bo A;Kim, Seojin
    • Journal of Conservation Science
    • /
    • v.29 no.4
    • /
    • pp.311-320
    • /
    • 2013
  • The showcase has insufficient temperature control, but it has excellent humidity control. The annual average temperature and relative humidity inside the showcase was $18.8^{\circ}C$ and 60.3%, respectively, and the showcase showed lower temperature and higher humidity than the exhibition room. The temperature inside the showcase appeared with high variation according to the seasons, while relative humidity was ranging from 59% to 61% regardless of the seasons. The showcase showed high temperature and humidity likewise the exhibition room in summer. In addition, lowering of temperature was elevated relative humidity according to the operation of air conditioner in summer. A moisture problem occurred because the temperature and humidity differences between the exhibition room and showcase were large according to the operation of air conditioner in winter. PI for temperature and relative humidity inside the showcase is 18.0%, and it means conservation environment for exhibition is unsuitable. In particular, continuous management of temperature and humidity inside the showcase is required because PI in the summer and winter is less than 1.0%.