Non-Stationary Stress Analysis of Repaired Concrete Structures due to Hygral Transient Condition

대기 습도변화에 따른 콘크리트 보수체의 비정상적인 습도응력 조사

  • 윤우현 (대전대학교 토목공학과)
  • Published : 1997.06.01

Abstract

The object of this study was invest, igat, ing the failure phenomenon in the contact zone of rcpnired concrete structures due to the external climate change(hygral transient condition). This study was carrie out by calculating the non-stationary moisture and stress distribution in the repaired concrete structures with the cement mortar. In this analysis, main variables were the overlay thickness (Do=0.5-2.5cm). and the pre-wetting time(tc= l-5days). and the cxtcrnal 1.~1ative humidity(Ho=50-80%). The results show that the minimum overlay thickness and the minimum pre-wetting time are necessary to k e ~ p compressive stresses in the contact zone for a relative humidity.

본 연구에서는 대기 습도변화에 의한 콘크리트 보수체(기층 콘크리트/보수 모르터)의 파괴현상을 조사하기 위해서 보수체내의 비정상적인 습도분포 및 습도응력을 계산하였다. 이러한 계산은 시멘트 모르터로 보수된 접촉면이 없는 보수체에서 보수층 두께(Do=05-2.5cm)와 보수 작업전 기층 콘크리트 표면의 습윤처리 시간(tc=1-5days) 및 대기습도(Ho=50~80%)를 주요변수로 하여 수행되었다. 계산 및 조사 결과에 의하면 접합면의 응력이 압축상태를 유지하기 위해서는 각 대기 습도마다 일정값 이상의 보수층 두께와 습윤처리 시간이 필요함을 알 수 있다.