Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

Real-time Interactive Control of Magnetic Resonance Imaging System Using High-speed Digital Signal Processors (고속 DSP를 이용한 실시간 자기공명영상시스템 제어)

  • 안창범;김휴정;이흥규
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.5
    • /
    • pp.341-349
    • /
    • 2003
  • A real time interactive controller (spectrometer) for magnetic resonance imaging (MRI) system has been developed using high speed digital signal processors (DSP). The controller generates radio frequency (rf) waveforms and audio frequency gradient waveforms and controls multiple receivers for data acquisition. By employing DSPs having high computational power (e.g., TMS320C670l) real time generation of complicated gradient waveforms and interactive control of selection planes are possible, which are important features in real-time imaging of moving organs, e.g., cardiac imaging. The spectrometer was successfully implemented at a 1.5 Tesla whole body MRI system for clinical application. Performance of the spectrometer is verified by various experiments including high- speed imaging such as fast spin echo (FSE) and echo planar imaging (EPI). These high-speed imaging techniques reduce measurement time, however, usually intensify artifact if there is any systematic phase error or jitter in the synchronization between the transmitter, receiver, and gradients.

Quantitative Evaluation of Optimized Fat-Suppression Techniques for T1 Weighted Cervical Spine MR Imaging: Comparison of TSE-CHESS and TSE-SPAIR (T1 강조 경추자기공명영상에 대한 최적의 지방소거기법의 정량적 평가: TSE-CHESS 과 TSE-SPAIR 의 비교)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.529-536
    • /
    • 2013
  • The purpose of this study is to know clinical usefulness for fat suppression of the body curved portion compared with TSE-CHESS and TSE-SPAIR technique. A total of 25 normal volunteers without cervical spine disease were studied on a 3.0 T MRI scanner. As a quantitative analysis, PSNRs and CNRs were evaluated by using two methods for fat suppression of the body curved portion. As a results, PSNRs and CNRs for fat suppression were significantly greater for the TSE-SPAIR technique compared to TSE-CHESS technique. In conclusion, this study showed that a TSE-SPAIR technique has improved PSNRs and CNRs for evaluating of fat suppression in the body curved portion. These conclusions in the future will be provided information in diagnosis of fat suppression for the body curved portion.

Projection-type Fast Spin Echo Imaging (프로젝션 타입 고속 스핀 에코 영상)

  • 김휴정;김치영;김상묵;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.42-51
    • /
    • 2000
  • Purpose: Projection-type Fast Spin Echo (PFSE) imaging is robust to patient motion or flow related artifact compared to conventional Fast Spin Echo (FSE) imaging, however, it has difficulty in controlling $T_2$ contrast. In this paper, Tz contrast in the PFSE method is analyzed and compared with those of the FSE method with various effective echo times by computer simulation. The contrasts in the FSE and PFSE methods are also compared by experiments with volunteers. From the analysis and simulation, it is shown that ${T_2}-weighted$ images can well be obtained by the PFSE method proposed. Materials and methods: Pulse sequence for the PFSE method is implemented at a 1.0 Tesla whole body MRI system and $T_2$ contrasts in the PFSE and FSE methods are analyzed by computer simulation and experiment with volunteers. For the simulation, a mathematical phantom composed of various $T_2$ values is devised and $T_2$ contrast in the reconstructed image by the PFSE is compared to those by the FSE method with various effective echo times. Multi-slice ${T_2}-weighted$ head images of the volunteers obtained by the PFSE method are also shown in comparison with those by the FSE method at a 1.0 Tesla whole body MRI system. Results: From the analysis, $T_2$ contrast by the PFSE method appears similar to those by the FSE method with the effective echo time in a range of SO-lOOms. Using a mathematical phantom, contrast in the PFSE image appears close to that by the FSE method with the effective echo time of 96ms. From experiment with volunteers, multi-slice $T_2-weighted$ images are obtained by the PFSE method having contrast similar to that of the FSE method with the effective echo time of 96ms. Reconstructed images by the PFSE method show less motion related artifact compared to those by the FSE method. Conclusion: The projection-type FSE imaging acquires multiple radial lines with different angles in polar coordinate in k space using multiple spin echoes. The PFSE method is robust to patient motion or flow, however, it has difficulty in controlling $T_2$ contrast compared to the FSE method. In this paper, it is shown that the PFSE method provides good $T_2$ contrast (${T_2}-weighted$ images) similar to the FSE method by both computer simulation and experiments with volunteers.

  • PDF

The Usefulness of Diffusion-weighted MR Imaging for Differentiation between Degenerative Spines and Infectious Spondylitis (퇴행성 척추와 감염성 척추염의 감별에 있어서 확산강조영상의 유용성)

  • 박원규;변우목;최준혁
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.152-157
    • /
    • 2002
  • Purpose : The differential diagnosis between Modic type I degenerative spine and infectious spondylitis sometimes is difficult, because the affected bone marrows in both disease show similar signal intensity on conventional MR imaging. We evaluate the usefulness of diffusion-wighted MR imaging for differential diagnosis between Modic type I degenerative spine and infectious spondylitis. Materials and methods : The spin-echo and diffusion-weighted MR images of eight patients with Modic type I degenerative spines and 14 patients with infectious spondylitis diagnosed by clinical findings or CT-guided biopsies we re analyzed. The diffusion-weighted imaging sequence was based on reversed fast imaging with steady-state precession (PSIF). Signal intensity changes of the vertebral bone marrow on conventional spin-echo and diffusion-weighted MR imaging were compared between degenerative spine and infectious spondylitis. Results : On T1-weighte d images, the affeted bone marrow in both disease showed hypointense signals. On T 2-weighted images, all of type I degenerative spine and 11 of infectious spondylitis showed hyperintensity, and three of infectious spondylitis showed heterogeneo us mixed signal intensity. On diffusion-weighted MR images, all of type I degenerative spine were hypointense with peripheral high signal intensity to normal vertebral body, but infectious spondylitis was hyperintense (n = 11) and hypointense (n=3). Conclusion : Diffusion-weighted MR imaging is useful to differentiate Modic type I degenerative spine from infectious spondylitis. On diffusion-weighted images, the high singal intensity of bone marrow suggests infectious spondylitis, whereas the low signal intensity of bone marrow with peripheral focal high signal intensity suggests type I degenerative spine.

  • PDF

Differential Diagnosis of Bicornuate and Septate Uterus : Is Comparison of Septal Signal Intensity on MR Image Useful\ulcorner (양각 자궁과 중격 자궁의 감멸 진단: 자기공명영상에서 자궁 격막 신호 강도의 비교는 유용한가\ulcorner)

  • 김종철;변재영;백승연
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.107-112
    • /
    • 2000
  • Purpose : To evaluate the usefulness of comparison of the signal intensity of uterine septum in the differential diagnosis of bicornuate and septate uterus on magnetic resonance (MR) imaging. Materials and methods : Preoperative MR imaging findings of surgically proven 5 bicornuate and 6 septate uteri were retrospectively analyzed. Because preoperative differential diagnosis of both was possible in all cases in terms of the intercornual distance, external contour of uterine fungus, and divergent angle of two uterine cavities, these criteria were excluded in this study. The signal intensity of uterine septum in patients with bicornuate and septate uterus was analyzed on T1-weighted and fast spin echo T2-weighted images obtained in the axial and coronal planes, using a 1.5-T MR scanner. The signal intensity of uterine septum especially on T2-weighted images was compared with that of myometrium or junctional zone. Results : The signal intensity of uterine septum in patients with bicornuate uterus (n=5) and septate uterus (n=6) was similar to that of myometrium in all cases on T1-weighted images. The septum of bicornuate uterus (n=5) on fast spin echo T2-weighted images was isointense with myometrium in three and hypointense in two cases. The uterine septum of septate uterus (n=6) on T2-weighted images was isointense with myometrium in two, hypointense in two, and isointense with or more hypointense than junctional zone in two cases. No patient showed different signal intensity between upper and lower uterine septum. Conclusion : Because the MR signal intensity of the uterine septum in bicornuate or septate uterus is variable, it should not be used alone in the differential diagnosis of them. In these clinically important differentiation, therefore, comprehensive analysis of MR findings in terms of the external contour of uterine fundus, intercornual distance, divergent angle of two uterine cavities, in addition to the signal intensity of the uterine septum, should be considered.

  • PDF

MR Imaging Findings of Uterine Cervical Adenocarcinoma (자궁경부 선암종의 자기공명영상 소견)

  • 김종철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.113-119
    • /
    • 1998
  • Purpose : Because adenocarcinomas of the uterine cervix have lower 5-year survival rate than squamous cell carcinomas due to early lymph node metastasis and local extension, scrutiny of lymph node metastasis and local extension by radiologic examination is necessary in case of clinically diagnosed or suspected adenocarcinomas. The purpose of this study is to evaluate whether there are specific findings of these tumors, compared with squamous cell carcinomas, through the analysis of magnetic resonance (MR) imaging findings. Materials and Methods : Of 21 pathologically proven cervical adenocarcinomas, MR imaging findings of 18 tumors (histologic staging : two Ib, four IIa, two IIb, one IIIa, and one IIIb) were retrospectively analyzed and compared with those of 40 wquamous cell carcinoma in consecutive patients as a control group. T1-wetighted and fast spin echo T2-weighted images were obtained on the axial and sagittal planes, using a 1.5-T MR scanner. The largest diameter, location, signal intensity and degree of contrast enhancement contour, shape and longitudinal extent of the tumor and associated findings on MR image were analyzed. Results : The largest diameters of cervical adenocarcinomas ranged from 0.8 to 4.1 cm(mean, 2.2 cm). Of 18 adenocarcinomas, nine were of endocervical type. All adenocarcinomas were isointense to surrounding cervical stroma on T1-weighted images and hyperintense(homogeneous in ten, inhomogeneous in eight) on fast spin echo T2-weighted images. Adenocarcinomas enhanced on contrast study in all patients (homogeneous in six, inhomogeneous in 12 with hyperintese enhnacing rim in two). Eight adenocarcinomas had smooth contours and ten had irregular ones. The shape of adenocarcinoma was irregular in eight patients, barrel shape in six, papillary/polypod in three, and nodular in one. All adenocarcinomas involved lower half of the uterine cervix and six tumors extended up to the upper half. Pelvic lymph nodes of more than 1.5cm in diameter in two adenocarcinomas pateints and no detectable small pelvic lymph nodes on MR imaging in one patient were pathologically positive. Hydrometra was associated in two adenocarcinomas patients, and hematometra in one patient. Compared with squamous cell carcinomas, more frequent MR findings of endocervical type and barrel shape in cervical adenocarcinomas were statistically significant. Conclusion : Cervical adenocarcinomas had more frequent MR findings of endocervical type and barrel shape, compared with wquamous cell carcinomas. Adenocarcinoma of the uterine cervix may be suspected on MR imaging, when a cervical carcinoma is of barrel shape along the endocervical canal and tends to involve lymth nodes in earlier stages.

  • PDF

Impact of Deep-Learning Based Reconstruction on Single-Breath-Hold, Single-Shot Fast Spin-Echo in MR Enterography for Crohn's Disease (크론병에서 자기공명영상 장운동기록의 단일호흡 단발 고속 스핀 에코기법: 딥러닝 기반 재구성의 영향)

  • Eun Joo Park;Yedaun Lee;Joonsung Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1309-1323
    • /
    • 2023
  • Purpose To assess the quality of four images obtained using single-breath-hold (SBH), single-shot fast spin-echo (SSFSE) and multiple-breath-hold (MBH) SSFSE with and without deep-learning based reconstruction (DLR) in patients with Crohn's disease. Materials and Methods This study included 61 patients who underwent MR enterography (MRE) for Crohn's disease. The following images were compared: SBH-SSFSE with (SBH-DLR) and without (SBH-conventional reconstruction [CR]) DLR and MBH-SSFSE with (MBH-DLR) and without (MBH-CR) DLR. Two radiologists independently reviewed the overall image quality, artifacts, sharpness, and motion-related signal loss using a 5-point scale. Three inflammatory parameters were evaluated in the ileum, the terminal ileum, and the colon. Moreover, the presence of a spatial misalignment was evaluated. Signal-to-noise ratio (SNR) was calculated at two locations for each sequence. Results DLR significantly improved the image quality, artifacts, and sharpness of the SBH images. No significant differences in scores between MBH-CR and SBH-DLR were detected. SBH-DLR had the highest SNR (p < 0.001). The inter-reader agreement for inflammatory parameters was good to excellent (κ = 0.76-0.95) and the inter-sequence agreement was nearly perfect (κ = 0.92-0.94). Misalignment artifacts were observed more frequently in the MBH images than in the SBH images (p < 0.001). Conclusion SBH-DLR demonstrated equivalent quality and performance compared to MBH-CR. Furthermore, it can be acquired in less than half the time, without multiple BHs and reduce slice misalignments.

The Comparative Imaging Study on Mn-phthalocyanine and Mangafodipir trisodium in Experimental VX2 Animal Model (실험적으로 유발시킨 VX2 동물모델에서의 Mn-phthalocyanine과 Mangafodipir trisodium의 비교영상)

  • Park Hyun-Jeong;Ko Sung-Min;Kim Yong-Sun;Chang Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.32-41
    • /
    • 2004
  • Purpose : To measure the NMR relaxation properties of MnPC, to observe the characteristics of liver enhancement patterns on MR images in experimentally implanted rabbit VX2 tumor model, and to estimate the possibility of tissue specific contrast agent for MnPC in comparison with the hepatobiliary agent. Materials and Methods : Phthalocyanine (PC) was chelated with paramagnetic ions, manganese (Mn). 2.01 g (5.2 mmol) of phthalocyanine was mixed with 0.37 g (1.4 nlmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography ($CHCl_3:\;CH_3OH=98:2$, volume ratio) to obtain 1.04 g $(46\%)$ of MnPC (molecular weight = 2000 daltons). The T1/T2 relaxivity (R1/R2) for MnPC were determined at a 1.5 T (64 MHz) MR spectrometer. VX2 tumor model was experimentally implanted in the liver parenchyma of rabbits. All MR studies were performed on 1.5 T. The human extremity radio frequency coil of a bird cage type was employed. MR images were acquired at 17 to 24 days after VX2 carcinoma implantation.4 mmol/kg MnPC and 0.01 mmol/kg Mn-DPDP were injected via the ear vein of rabbits. T1-weighted images were obtained with spin-echo (TR/TE=516/14 msec) and fast multiplanar spoiled gradient recalled (TR/TE : 80/4 msec, $60^{\circ}$ flip angle) pulse sequence. Fast spin-echo (TR/TE=1200/85 msec) was used to obtain the T2-weighted images. Results : The value of T1/T2 relaxivity (R1/R2) of MnPC was $7.28\;mM^{-1}S^{-1}$ and $55.56\;mM^{-1}S^{-1}$ respectively at 1.5 T (64 MHz). Because the T2 relaxivity of MnPC that bonded strongly, covalently manganese with phthalocyanine was very high, the signal intensity of liver parenchyma was decreased on postcontrast T2-weighted images and we could easily distinguish the VX2 carcinoma within the liver parenchyma. When MnPC was administrated intravenously, the tumor margin delineation was more remarkable than Mn-DPDP-enhanced images. The enhancement of liver parenchyma with MnPC persisted at relatively high levels over at least one hour after injection of the contrast agents. Conclusion : The hepatic uptake and biliary excretion of MnPC, which are similar to Mn-DPDP, suggest that this agent is a new liver-specific agent. Also, MnPC seems to be used as a dual contrast agent (T1 and T2) with high T2 relaxivity. However, it is warranted that MnPC needs further investigation as a potential contrast agent for MR imaging of the liver. That is, further characterizations of MnPC are needed in vivo and in vitro before clinical trials. The diagnostic potential of MnPC will also have to be examined more in the animal models of additional types.

  • PDF

Evaluation of the Image Blurring in the Fast Spin Echo Technique ccording to Variation of the ETL (고속스핀에코기법을 이용한 MRI검사에서 ETL 변화에 따른 영상 blurring의 평가)

  • Kwon, Soon-Yong;Lim, Woo-Taek;Kang, Chung-Hawn;Kim, Kyeong-Soo;Kim, Soon-Bae;Kim, Hyun-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.55-61
    • /
    • 2013
  • The purpose of this study is to evaluate image blurring according to variation of the ETL and propose the clinically appropriate ETL range. SIEMENS MAGNETOM Skyra 3.0T and 20 channel head coil were used for the study. MRI phantom was kept the lines horizontally to three direction(X,Y,Z) of the coil and T1, T2 weighted images that used the fast spin echo technique acquired. The ETL with increase of 10 was applied from 10 to 80. In addition, the ETL with increase of 1 was applied in the interval statistically significant differences occurred. And T1, T2 weighted images that used the conventional spin echo technique acquired to compare image blurring of the images that used the fast spin echo technique. The slope of lattice in the images was measured using Image J 1.47v program to evaluate image blurring. And image blurring was determined by the degree of the slope. The statistical significance of both techniques was evaluated by the Kruskal-Wallis test of the SPSS 17.0v. And the correlation of the ETL and image blurring was evaluated quantitatively by regression analysis. The slope of the T1, T2 weighted images that used fast spin echo technique decreased as contrasted with conventional spin echo technique. In the result of the Kruskal-Wallis test, the T1, T2 weighted images that used fast spin echo technique made a significant difference with conventional spin echo technique. Particularly, in the Tomhane' T2 test, the T1, T2 weighted images made a significant difference from ETL 22 and 31 respectively. In the result of the regression analysis, the R-squared of the T1, T2 weighted images are 0.762 and 0.793. It is difficult to apply the long ETL in the T1 weighted image caused by the short TR and multi-slices study. Therefore, clinical impact according to variation of the ETL is very slight in the T1 weighted images. But the application of the proper ETL is demanded in T2 weighted images using the fast spin echo technique in order to prevent image blurring.

  • PDF