The Proposition of Domestic Sprinklers Installation Standard and the Fire Services Act (국내 스프링클러 설치기준과 소방관련 법에 관한 고찰)

  • Kim, Yong-Moon;Lee, Young-Jai
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.17-24
    • /
    • 2014
  • Recently, many accidents occur frequently because sprinklers aren't installed or don't work right when there are outbreak of fire in houses and aggregate buildings. Therefore, they can result in damage for humans and loss of property. Sprinklers are the most appropriate which can extinguish buildings' fire in the initial stages. Through lack of legal system, in domestic cases, sprinklers cannot operate their inherent performance. Domestic standard simply classifies installation objects according to types of business and forms of buildings, also divides into uses and floors of buildings. Especially it only regulates that sprinklers must be installed every floors in particular fire buildings that have more than eleven floors. While it doesn't need to install sprinklers below ten floors, so we are threatened the safety. In this study, we derived causes and implications by analyzing concepts of sprinklers facilities, installation standards in domestic and foreign legal system, and recent cases that expanded damages in fire accidents because of weak point of installation and control standards. In domestic cases, as a result, government has to provide an institutional strategy and law that regulate duty to install sprinklers to all aggregate buildings regardless of floors in terms of new buildings. Also, if someone who has existing buildings wanted to install them, government would guarantee subsidy to encourage installation. In addition, government supervises fire-fighting activities when there are fire by compensating standards about regular inspection by a qualified technician, operation and maintenance of sprinklers as well as reinforcement of administrative criteria.

The Study on Real Scale Fire Test for Fire Suppression Performance of Sprinkler System in Sandwich Panel (샌드위치패널의 화재 시 스프링클러의 초기 진압에 대한 실험적 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl;An, Hyeong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.107-110
    • /
    • 2011
  • 스티로폼 샌드위치패널은 심재의 연소 특성에 의해 화재 사고 발생 시 많은 인명과 재산 피해를 발생시키며, 복합재료로 구성되어 있는 재료의 특성으로 화재 안전에 대한 정확 기준이 정립되어 있지 못한 실정이다. 따라서 본 연구에서는 (4.8(L) ${\times}$ 7.2(W) ${\times}$ 4.8(H) m) 크기의 Mock-up을 제작하고 내부에 스프링클러를 설치하여 스티로폼 샌드위치패널의 화재 시 스프링클러의 초기 진압 가능성 여부를 판단하고 하였다. 실험 시작 약 2분 후 스프링클러가 작동하였으며, 스프링클러 작동 후 약 4분후에 천장부가 되괴되면서 플래시오버가 발생되었다. 내부의 최대 온도는 버너 근처에서 약 $335.6^{\circ}C$로 측정되었다.

  • PDF

A Study on a PCB Manufacturing Plant's Fire Risk Assessment due to the Mitigation of Fire Protection Zone and an Improvement Way through Estimation of Sprinkler Demand Water Flow Rate (방화구획 완화에 따른 PCB공장의 화재위험평가 및 스프링클러 요구살수유량 산정을 통한 기준개선안에 관한 연구)

  • Oh, Chan-Wook;Oh, Ryun-Seok;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.56-62
    • /
    • 2019
  • A sprinkler is a fire extinguishing equipment installed in a protected area where a detector or head detects a fire and automatically puts out the fire. However, the Ministry of Land, Infrastructure and Transport's "Regulations on Building Evacuation and Fire Protection Standards, etc." stipulate that fire compartment area should be reduced to three times by installing sprinkler facilities in the case of factories and warehouses. In this study, fire hazard was analyzed for a real PCB factory which mitigated the fire protection zone by sprinkler installation, and the head opening characteristics of sprinkler facilities through computer simulation, installation standards of sprinkler facilities, thermal performance, operating range, and the amount of water sprayed to identify the problems of operation of sprinkler facilities in case of fire, and to suggest the grounds such as required sprinkling flow rate for system improvement.

A Study on the Problem of Pressure and Flow Rate by Prescriptive Code Based Design of Fire Sprinkler System (사양위주 스프링클러설비 설계의 압력과 유량의 문제점에 대한 고찰)

  • Jeong, Keesin;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.14-19
    • /
    • 2013
  • National Fire Safety Code 103 regulates that all operating sprinkler in design area must be discharged 1 bar or more pressure and release 80 lpm or more flow rate as minimum criteria. NFSC103 also provides that the number of operating sprinkler in design area is 10, 20, 30 according to the building classification and the total flow rate is 800, 1,600, 2,400 lpm depending on 80 lpm per sprinkler. If sprinkler system is designed as above provisions, the pressure and the flow rate accordingly become smaller than the minimum criteria about 50 % sprinklers. It results in serious consequence that the purpose of sprinkler system as initial fire reaction equipment is failure. In order to solve these problems, It is desirable that Performance-based fire protection design, hydraulic calculation, is carried out to all sprinkler system.

A study on prediction and improvement method of fire risk for a newly built college dormitory (신축 승선생활관의 화재 위험성 예측 및 개선방안에 관한 연구)

  • Kim, Byeol;Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.228-234
    • /
    • 2016
  • As a college dormitory has the features of high dwelling density and a floating population that becomes crowded during particular times, when a disaster such as a fire occurs, it has the risk of causing much loss of life. In this study, the fire simulation program Fire Dynamics Simulator (FDS), is used to predict the risk when a fire occurs, to analyze the problem, and to suggest an improvement plan for a new cadet dormitory at an university in Korea. The research results are as follows. When a fire occurred in the ironing room inside the cadet dormitory, a smoke detector operated after 65 seconds. Thirteen seconds later, a sprinkler started to operate. The temperature and carbon monoxide density reached the limit value at 241 and 248 seconds, respectively. Because the limit visibility value was reached within 66 seconds after the occurrence of a fire, it is predicted that preparation must be finished and evacuation should begin within 1 minute after the fire occurs, in order to have no casualties. Synthesizing this dormitory fire risk prediction result, the visibility value is considered to be the most dangerous factor for personal safety. Because of this, installing a smoke extraction system is suggested to secure visibility. After the installation of a smoke extraction system, the problem of smoke diffusion in the corridors improved.

The Neutralization Treatment of Waste Mortar and Recycled Aggregate by Using the scCO2-Water-Aggregate Reaction (초임계이산화탄소-물-골재 반응을 이용한 폐모르타르와 순환골재의 중성화 처리)

  • Kim, Taehyoung;Lee, Jinkyun;Chung, Chul-woo;Kim, Jihyun;Lee, Minhee;Kim, Seon-ok
    • Economic and Environmental Geology
    • /
    • v.51 no.4
    • /
    • pp.359-370
    • /
    • 2018
  • The batch and column experiments were performed to overcome the limitation of the neutralization process using the $scCO_2$-water-recycled aggregate, reducing its treatment time to 3 hour. The waste cement mortar and two kinds of recycled aggregate were used for the experiment. In the extraction batch experiment, three different types of waste mortar were reacted with water and $scCO_2$ for 1 ~ 24 hour and the pH of extracted solution from the treated waste mortar was measured to determine the minimum reaction time maintaining below 9.8 of pH. The continuous column experiment was also performed to identify the pH reduction effect of the neutralization process for the massive recycled aggregate, considering the non-equilibrium reaction in the field. Thirty five gram of waste mortar was mixed with 70 mL of distilled water in a high pressurized stainless steel cell at 100 bar and $50^{\circ}C$ for 1 ~ 24 hour as the neutralization process. The dried waste mortar was mixed with water at 150 rpm for 10 min. and the pH of water was measured for 15 days. The XRD and TG/DTA analyses for the waste mortar before and after the reaction were performed to identify the mineralogical change during the neutralization process. The acryl column (16 cm in diameter, 1 m in length) was packed with 3 hour treated (or untreated) recycled aggregate and 220 liter of distilled water was flushed down into the column. The pH and $Ca^{2+}$ concentration of the effluent from the column were measured at the certain time interval. The pH of extracted water from 3 hour treated waste mortar (10 ~ 13 mm in diameter) maintained below 9.8 (the legal limit). From XRD and TG/DTA analyses, the amount of portlandite in the waste mortar decreased after the neutralization process but the calcite was created as the secondary mineral. From the column experiment, the pH of the effluent from the column packed with 3 hour treated recycled aggregate kept below 9.8 regardless of their sizes, identifying that the recycled aggregate with 3 hour $scCO_2$ treatment can be reused in real construction sites.