• Title/Summary/Keyword: 스텝응답

Search Result 47, Processing Time 0.026 seconds

Study of Thrust Control Performance Improvement for Hybrid Rocket Applications (하이브리드 로켓의 추력제어 성능 향상에 관한 연구)

  • Choi, Jae-Sung;Kang, Wan-Kyu;Huh, Hwan-Il
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.1
    • /
    • pp.55-62
    • /
    • 2011
  • In this study, we tried to improve the thrust control performance through the thrust control combustion experiment of the hybrid rocket. We constructed the system which controls the oxidizer flow by combining a needle valve with a stepping motor and controlling the stepping motor drive according to the thrust control command order. Gas oxygen was used as the oxidizer for two different propellants, PE(Polyethylene), PC(Polycarbonate), respectively. To improve the slow response time and the oscillation phenomenon in the beginning stage of the thrust control combustion experiment, we measured and analyzed the change of the flow speed of the propellant pipe. The revised thrust control combustion experiment showed that the thrust was stably controlled with the margin or error from the thrust command within ${\pm}1$ N.

Stepped Impedance LPF using MCSl (MCS선로를 이용한 스텝 임피던스 저역필터)

  • Rhee, Seungyeop;Lee, Seongjae;Kim, On
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.3
    • /
    • pp.153-157
    • /
    • 2008
  • The MCS(Micro-coplanar strip) line has been analyzed. The conformal mapping method is used to calculate the quasi-static effective permittivity and characteristic impedance of this MCS line. The computed results of the present work are found to be in good agreement when compared with the results obtained using commercial S/W, IE3D. And in this paper, the stepped-impedance low pass microstrip filter is designed and fabricated with MCS lines for improving the frequency responses. The LPF proposed structure has been also designed and implemented to have the sharp attenuation characteristics in stop band. The agreement between simulation and measurement results verify the implemented LPF.

  • PDF

A Study on the Job Performance of Dental Coordinators and Their Perception (치과코디네이터의 업무수행 및 인식도에 관한 조사연구)

  • Kwon, Soon-Bok;Kim, Young-Nam;Moon, Hee-Jung;Shin, Myung-Suk;Han, Gyeong-Soon;Han, Su-Jin
    • Journal of dental hygiene science
    • /
    • v.5 no.4
    • /
    • pp.211-220
    • /
    • 2005
  • The purpose of this study was to examine the job performance of dental coordinators and their perception of their job to lay the groundwork for utilizing dental personnels more efficiently. The subjects in this study were dental coordinators who worked at selected dental hospitals and clinics in Seoul, Gyeonggi province and Incheon. A survey was conducted to gather data from May 1 to August 8, 2005 and answer sheets from 108 respondents were analyzed. The findings of the study were as follows: 1. As for the length of service, 43.5 percent of the dental coordinators investigated had worked at dental institutes for five years or more, which was followed by less than two years(19.5%) and three years to less than five years(19.4%). Concerning the length of service as dental coordinators, 39.8 percent had served for less than two years, and 19.4 percent had worked for two years to less than three years and for five years or more respectively. Regarding the name of position, 38 percent were called team leaders, and 30.6 percent were called coordinators. As to duties, the largest group of them that stood at 30.6 percent were in charge of receiving, and in regard to department, the largest group, 57.4 percent, belonged to the treatment backup department. 2. Concerning education, the greatest number of them, 45.4 percent, had received education at private institutes, and 73.1 percent found it necessary for dental coordinators to take an authorized qualification test. 43.5 percent, the largest group, looked upon the central government as the best organization to authorize their qualifications and 70.8 percent believed that what they learned enabled them to perform their job successfully. As to the necessity of follow-up education as a means to improve job performance, 96.3 percent consented to it. As for the reason, 63.9 percent considered that necessary to enhance their own ability and 22.2 percent were in want of systematic education. Regarding educational expenses, 29.6 percent were subsidized by the dental institutes where they had worked and 25.9 percent had totally been responsible for that. Regarding a required course, medical service and marketing was most widely pointed out(66.7%), followed by theory and practice(65.7%) and introduction to dentistry(57.4%). As to what sort of education they wanted to receive more, dental service and marketing was selected the most, followed by practical health insurance(35.2%). 3. In regard to what type of job they performed as dental coordinators, 88.9 percent were in charge of appointment in the field of customer service, and 87.9 percent paid attention to having good manners as service providers in the area of self-management. In the field of hospital affairs, 81.3 percent were in charge of receiving. 4. As to their awareness of dental coordinator job, the largest group took pride in the job they performed ($3.99{\pm}0.76$), and the second largest group believed that dental coordinators made a great contribution to hospital management ($3.92{\pm}0.70$). The third largest group gave a great weight to their own job ($3.91{\pm}0.84$) in light of overall dental duties and the fourth largest group found themselves to get along with other employees regardless of position ($3.86{\pm}0.74$). The fifth largest group believed their job was of great use for promoting the oral health of patients ($3.76{\pm}0.75$), and the sixth largest group thought the future of dental coordinators was promising($3.74{\pm}0.86$). 5. In regard to their perception by age group, those who were older had a better opinion on every item of their job in general. Their age made a statistically significant difference to their view of the weight of dental coordinator job(P < 0.001) in light of overall dental duties, of being approved and trusted by managers(P < 0.01), of social awareness of dental coordinator, and of being understood and approved by other employees and dentists. Their pride in current job and their satisfaction with the name of their position were statistically significantly different according to their age as well. Besides, their age made a statistically significant difference to their opinion about whether or not there was an age limit to their occupation and about their contribution to hospital management (P < 0.05). 6. As for their perception by type of job, the dental hygienists were generally most satisfied with their job, followed by nursing aids and others. There was a statistically significant gap among their opinions about whether to make a job-related decision on their own(P < 0.001). the weight of their job in terms of overall dental duties, whether their job improved their ability, whether their job made a great contribution to enhancing the oral health of patients, whether their job was understood and approved by other employees(P < 0.01), social awareness of their job, whether they conflicted with other employees during job performance, and whether dental hospitals or clinics offered a self-development opportunity for them to take their ability to another level(P < 0.05). And their satisfaction with current pay was statistically significantly different as well.

  • PDF

A New Sensorless Control Scheme Using Simple Duty Feedback Technique in DC/DC Converters (DC/DC 컨버터에서 Duty Feedback을 이용한 새로운 센서리스 제어기법)

  • 이동윤;노형주;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.6
    • /
    • pp.554-562
    • /
    • 2002
  • This paper presents a new sensorless control scheme using simple duty signal feedback technique in DC/DC converters. The proposed Duty Feedback Control(DFC) has the characteristics that they show the same as operation performance of current mode control by using duty feedback technique without current sensor as well as present faster dynamic response performance than conventional Sensorless Current Mode(SCM) control in case that input source is perturbed by step change or DC input source includes the harmonics. Also, the proposed control scheme has good noise immunity and simple control circuits since they have one feedback loop, and can be applied to all DC/DC converters. The concept and control principles of the proposed control scheme are explained in detail and the validity of the proposed control scheme is verified through several interesting simulated and experimental results.

Ornithopter actuator characteristics analysis by motion capture experiment (모션캡쳐 실험을 통한 조류모방 날갯짓 비행체 구동 특성 분석)

  • Gim, Hakseong;Kim, Seungkeun;Suk, Jinyoung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.3
    • /
    • pp.173-179
    • /
    • 2017
  • This paper analyzes actuator characteristics for main wing and tail surfaces of an ornithopter by using a motion capture test. Experiments with the ornithopter are conducted indoor, and its fuselage is held on a jig to reduce interaction with vibration generated by flapping motion. The motion capture system detects the movement of markers attached on the main wing and tail wing tip. Experimental results show that the main wings tend to change its amplitude according to the flapping frequency, and the lift and thrust generation simulation is implemented by applying the experimental results and the ornithopter specification to Modified Strip Theory. Step input excitation is applied for experimental analysis of the tail wing in horizontal and vertical directions. As a result, horizontal and vertical tail wings have different characteristics in terms of overshoot, final value, damping ratio and natural frequency because they have different wing structures and linkages.

Design and Analysis of a Battery Charge and Discharge Regulator of Communication Satellite (통신위성 배터리 충,방전기 설계 및 해석)

  • Choe,Jae-Dong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.7
    • /
    • pp.118-126
    • /
    • 2003
  • In this study, a battery charge and discharge regulator of modular type is designed as paralleled bi-directional converter that is possible to provide the power without failure not only in the steady state but also in the transient period by the step load variation or the unexpected faults among the converter modules. Each converter module is designed to get stability, performance, reliability, and maintainability and the average current mode method used for controller has the advantages such as noise immunity, fast response, and the real average current signal acquisition. The equivalent model and small signal model for the paralleled battery chargerIdischarger are presented, and also the transfer functions are analyzed for the CCM(Continuous Charge Mode), CDM(Continuous Discharge Mode) and DDM(Discontinuous Discharge Mode). The experiments of the paralleled bi-directional converter are carried out in the step load variation, and in faults of one converter module respectively. And the performance of paralleled bi-directional converter is verified via the experimental results.

Development of VPO MPPT of PV System Considering Shadow Influence (그림자 영향을 고려한 PV 시스템의 VPO MPPT 제어)

  • Choi, Jung-Sik;Ko, Jae-Sub;Chung, Dong-Hwa
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.521-531
    • /
    • 2011
  • This paper presents the variable perturbation and observation(VPO) maximum power point tracking(MPPT) control of the photovoltaic(PV) system considering the shadow influence. The output characteristics of the solar cell is a nonlinear and affected by a temperature, the solar radiation and influence of a shadow. MPPT control is a very important technique in order to increase an output and efficiency of the solar power generation. Conventional perturbation and observation(PO) and incremental conductance(IC) are the method finding MPP by the continued self-excitation vibration. The MPPT control is unable to be performed by rapid output change affected by the shadow. To solve this problem, this paper proposes the VPO MPPT algorithm which changes step size according to output variation. The response characteristics of VPO MPPT algorithm proposed in this paper compares with response characteristics of conventional MPPT algorithm about the radiation, temperature and shadow influence. The validity of the algorithm proposed in this paper prove through the results of the comparisons.