• Title/Summary/Keyword: 스케일 제거

Search Result 152, Processing Time 0.025 seconds

Prevention of Particulate Scale with a New winding Method in the Electronic Descaling Technology (새 도선 감는 방법을 적용한 전기장 이용 스케일 제거)

  • Son, Chang-Hyeon;Gu, Sang-Mo;Kim, Chang-Su;Kim, Geon-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.5
    • /
    • pp.658-665
    • /
    • 2002
  • This paper presents a new winding method in electronic descaling (ED) technology. Conventional ED technology Produces an oscillating electric field via Faraday's law to provide the necessary molecular agitation to dissolve mineral ions. However, the proposed method produces an additional agitation force for mineral ions, called Lorentz's force. Experiments were performed using various Renolds numbers. A series of tests was conducted to measure the pressure drop across the test section and the overall heat transfer coefficient as a function of time. In order to accelerate the rate of fouling, artificial hard water, 1000ppm CaCO$_3$, was used throughout the tests. The results show that the new winding method accelerates the collision of the mineral ions, thereby improving the system efficiency. The present study can develope more effective fouling-removing equipment with change of estabishment method of coil.

Complex odor removal in pilot-scale biofilter with microorganisms immobilized on polymer gel media (미생물 포괄고정화 담체를 적용한 파일럿 스케일 바이오필터에서의 복합악취 제거)

  • Kim, Sun-Jin;Kim, Tae-Hyeong;Lee, Yun-Hee;Jang, Hyun-Sup;Song, Ji-Hyeon;Hwang, Sun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.741-750
    • /
    • 2011
  • A pilot-scale biofilter was constructed to discover degradation characteristics of the complex odor discharged from Ansan wastewater treatment plant. Candida tropicalis for volatile organic compounds, sulfur oxidizing bacteria(SOB) for hydrogen sulfide, and bacteria extracted from feces soil were immobilized on a polymer gel media. According to this study, the EBCT was varied from 36 sec to 18 sec. Toluene was removed as 80% along the variations, but it was recovered as 100% within 1 week. All benzene and xylene were removed during the operation while the efficiency of hydrogen sulfur was temporary decreased at 18 sec of EBCT, thereafter it was recovered to 100% within a week. The maximum elimination capacities of the benzene, toluene, xylene, and hydrogen sulfur were 6.6 g/$m^{3}$/hr, 31.7 g/$m^{3}$/hr, 7.8 g/$m^{3}$/hr, and 133.6 g/$m^{3}$/hr, respectively. There were merits on removal both organic and inorganic complex odor using the pilot-scale biofilter embedded with microorganisms immobilized on polymer gel media.

Tracking Performance Improvement of the Double-Talk Robust Algorithm for Network Echo Cancellation (네트워크 반향제거를 위한 동시통화에 강인한 알고리듬의 추적 성능 개선)

  • Yoo, Jae-Ha
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.195-200
    • /
    • 2012
  • We present a new algorithm which can improve the tracking performance of the double-talk robust algorithm. A detection method of the echo path change and a modification method for the update equation of the conventional adaptive filter are proposed. A duration of the high error signal to scale parameter ratio varies according to the call status and this property is used to detect the echo path change. The proposed update equation of the adaptive filter improves the tracking performance by prohibiting wrong selection of the error signal. Simulations using real speech signals and echo paths of the ITU-T G.168 standard confirmed that as compared to the conventional algorithm, the proposed algorithm improved the tracking performance by more than 4 dB.

Study on the controller design of Electronic Water Cleaner (전자식 워터크리너 제어기 설계에 관한 연구)

  • Kim, Gwan-Hyung;Sin, Dong-Suk;Oh, Am-Suk;Choi, Dae-Woo;Kim, Ki-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.143-144
    • /
    • 2014
  • 일반적으로 집이나 건물이 지어진 후 약 2~3년이 지나면 수도관 내부에는 물때, 미생물, 유기화합물질 등이 혼합되어 슬라임(slime)이 발생하며, 노후화되어 슬러지(sludge) 형태로 누적 되거나 스케일(scale)이 발생하고 있다. 이러한 이물질의 누적으로 인하여 수도관이 손상되거나, 여러 가지 원인으로 인하여 교체해야하는 상황이 발생할 수 있다. 이러한 이유로 저수조나 공용관의 경우에는 정기적으로 세척하고 있으며, 일반 가정 내의 수도관 역시 정기적인 관리가 필요하다고 볼 수 있다. 본 논문에서는 적절한 배관청소기의 제어를 위하여 물과 압축공기의 배합을 적절하게 제어하도록 하여 배관내부의 이물질을 제거할 수 있는 배관청소시스템을 설계하고자 하며, 밸브조절 및 물의 공급시간과 압축공기의 유입시간에 대한 적절한 제어를 원격지에서 제어할 수 있도록 배관청소시스템을 개발하여 성능에 관한 평가와 사업화 가능성을 제시하고자 한다.

  • PDF

An LBX Interleaving Watermarking Method with Robustness against Image Removing Attack (영상제거 공격에 강인한 LBX 인터리빙 워터마킹 방법)

  • 고성식;김정화
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.6
    • /
    • pp.1-7
    • /
    • 2004
  • The rapid growth of digital media and communication networks has created an urgent need for self-contained data identification methods to create adequate intellectual property right(IPR) protection technology. In this paper we propose a new watermarking method that could embed the gray-scale watermark logo in low frequency coefficients of discrete wavelet transform(DWT) domain as the marking space by using our Linear Bit-eXpansion(LBX) interleaving of gray-scale watermark, to use lots of watermark information without distortion of watermarked image quality and particularly to be robust against attack which could remove a part of image. Experimental results demonstrated the high robustness in particular against attacks such as image cropping and rotation which could remove a part of image.

A Study on Mixed Filter Algorithm for Restoration of Image Corrupted by AWGN (AWGN에 훼손된 영상복원을 위한 복합 필터 알고리즘에 관한 연구)

  • Yinyu, Gao;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.1064-1070
    • /
    • 2012
  • Nowadays, image processing has been applied in a variety of fields. In order to preserve the high quality of visual the degradation phenomenon for images should be removed. Noise is one of the representative elements cause of the degradation phenomenon and AWGN(additive white Gaussian noise) always damages images. In this paper, an mixed filter algorithm, which is based on parallel denoising method, is proposed to suppress AWGN. This algorithm parallels the spatial domain wiener filter and the wavelet domain thresholding method which thresholding function is selected based on scale level. The proposed modified thresholding function which considers the dependency between parent and child coefficient performs well on suppressing noise.

${SO_4}^{2-}$ ion Removal from Solution by Crystal Precipitation on Surface Active Glasses (표면활성유리에의 결정석출을 이용한 용액중 황산염 이온 제거)

  • 남명식;김철영
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.12
    • /
    • pp.1286-1293
    • /
    • 1998
  • ${SO_4}^{2-}$ ions present in industrial waste water if combined with other metal ions in the water can cause serious scale problem in a transporting pipe. In this study therefore ${SO_4}^{2-}$ ions in an acidic solution have been removed by using surface active glasses. Glasses with various compositions of $SiO_2-Na_2O-B_2O_3-RO$ (R=Mg, Ca, Sr, Ba) system were reacted in a ${SO_4}^{2-}$ ion-containing solution with various pHs ranging from 1 to 4 for various time the reacted glass surfaces were analyzed by XRD and SEM and all ions in the reacted solution were also measured ${SO_4}^{2-}$ ions in the solution were combined with divalent ions leached out of glass and precipitated on the glass surface as sulfate crystals. In this was the surface ion could be removed from the acidic solution. The sulfate ion removal capacity is closely related to the solubility product con-stants of the newly formed sulfate crystals. Almost no sulfate crystal was formed on the MgO-containing glass while sulfate crystals were easily formed on the glass containing either SrO or BaO This indicates that those glasses have strong removal efficiency of ${SO_4}^{2-}$ ions from the solution.

  • PDF

The Noise Level Assessment of Dental Equipment (치과 의료장비의 소음 수준 평가)

  • Lee, Jeong-Suk;Han, Ye-Seul;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.603-611
    • /
    • 2015
  • This research is aimed at cutting off hearing loss and other harmful factors due to noise and providing basic material for noise reduction plan. As the research method, this research assessed noise by measuring acoustic pressure level and frequency in various situation of non-treatment and treatment. As the measurement result, average noise degree of high speed handpiece of non-treatment, ultrasonic waves scaler, and low speed handpiece showed 58~66 dB(A). Average noise degree of scaling of treatment, tooth elimination, and denture adjust showed 73~81 dB(A). The result is inferior to recognized standards of noise induced hearing loss. But the result of assessing this with (noise rating) NR curve was NR-73~78, which exceeded general workplace noise standard. This level can cause hearing loss when exposed to a long time. Therefore, treatment office noise during dental treatment can cause psychological and physical damage in dental clinic employees, and it is urgently required to establish systematic and active noise reduction plan.

Noise Reduction using Spectral Subtraction in the Discrete Wavelet Transform Domain (이산 웨이브렛 변환영역에서의 스펙트럼 차감법을 이용한 잡음제거)

  • 김현기;이상운;홍재근
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.4
    • /
    • pp.306-315
    • /
    • 2001
  • In noise reduction method from noisy speech for speech recognition in noisy environments, conventional spectral subtraction method has a disadvantage which distinction of noise and speech is difficult, and characteristic of noise can't be estimated accurately. Also, noise reduction method in the wavelet transform domain has a disadvantage which loss of signal is generated in the high frequency domain. In order to compensate theme disadvantage, this paper propose spectral subtraction method in continuous wavelet transform domain which speech and non- speech intervals is distinguished by standard deviation of wavelet coefficient, and signal is divided three scales at different scale. The proposed method extract accurately characteristic of noise in order to apply spectral subtraction method by end detection and band division. The proposed method shows better performance than noise reduction method using conventional spectral subtraction and wavelet transform from viewpoint signal to noise ratio and Itakura-Saito distance by experimental.

  • PDF

Design of the Noise Suppressor Using the Perceptual Model and Wavelet Packet Transform (인지 모델과 웨이블릿 패킷 변환을 이용한 잡음 제거기 설계)

  • Kim, Mi-Seon;Park, Seo-Young;Kim, Young-Ju;Lee, In-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.7
    • /
    • pp.325-332
    • /
    • 2006
  • In this paper. we Propose the noise suppressor with the Perceptual model and wavelet packet transform. The objective is to enhance speech corrupted colored or non-stationary noise. If corrupted noise is colored. subband approach would be more efficient than whole band one. To avoid serious residual noise and speech distortion, we must adjust the Wavelet Coefficient Threshold (WCT). In this Paper. the subband is designed matching with the critical band and WCT is adapted noise masking threshold (NMT) and segmental signal to noise ratio (seg_SNR). Consequently. it has similar Performance with EVRC in PESQ-MOS. But it's better than wavelet packet transform using universal threshold about 0.289 in PESQ-MOS. The important thing is that it's more useful than EVRC in coded speech. In coded speech. PESQ-MOS is higher than EVRC about 0.23.