The explosive growth of Internet traffic cause by smart equipment such as smart phone has led to a dramatic increase in demand for data transmission capacity and network control architecture, which requires high transmission rates beyond the conventional transmission capability. Next generation networks are expected to be controlled by Generalized Multi-Protocol Label Switching(GMPLS) protocol suite and operating at multiple switching layers. In order to ensure the most efficient utilization of multilayer network resources, effective global provisioning that providing the network with the possibility of reacting in advance to traffic changes should be provided. In this paper, we proposes a new path selection scheme in multilayer optical networks based on the vertical PCE architecture and a different approach to efficiently exploit multiple PCE cooperation.
Proceedings of the Korean Institute of Information and Commucation Sciences Conference
/
v.9
no.1
/
pp.947-950
/
2005
For revolving and elevating a turret of a tank, we substitute an existing oil pressure system with an electric system using a motor and applied the vector control method to this system. A switching method of an inverter for providing desired sinusoidal current to each phase of a motor, we adopted min-max pulse width modulation method which takes less computation time, rather than space vector pulse width modulation method. We designed a digital filter and applied it to the control system. Developed current controller is verified it's performance through a current control test, speed control test, frequency response and tracking a profile of speed test.
Journal of the Korea Institute of Information and Communication Engineering
/
v.2
no.2
/
pp.223-230
/
1998
This paper describes a phase-shift pulse-width modulation and pulse-frequency modulation series resonant high-frequency inverter using IGBT(Insulated-Gated Bipolar Transistor) for the power control of high-frequency induction heating using neuro-fuzzy, which is practically applied for 20KHz~500KHz induction-heating and melting power supply in industrial fields. The adaptive frequency tracking based phase-shifting PWM(Pulse-Width Modulation) regulation scheme is presented in order to minimize switching losses. The trially-produced breadboards using IGBT are successfully demonstrated and discussed.
Park, Byung-Chul;Park, Ji-Ho;Song, Sung-Geun;Park, Sung-Jun;Shin, Joong-Rin
The Transactions of the Korean Institute of Power Electronics
/
v.18
no.5
/
pp.477-484
/
2013
This paper proposes a novel switching method of active clamp snubber for efficiency improvement of PV module integrated converter(MIC) system. Recently, MIC solar system is researched about the efficiency and safety. PV MIC system is used active clamp method of snubber circuit for the price and reliability of the system. But active clamp snubber circuit has the disadvantage that system efficiency is decreased for switch operating time because of heat loss of resonant between snubber capacitor and leakage inductance. To solve this problem, this paper proposes a novel switching method of the active clamp. The proposed method is a technique to reduce power consumption by reducing the resonance of the snubber switch operation time and through simulations and experiments proved the validity.
Multiple output converters (MOCs) are widely used for applications which require various levels of the output voltages due to their benefits in cost, volume, and efficiency. However, most of the MOCs developed so far can regulate only one output tightly and require as many secondary windings in the transformer as the number of the outputs. In this paper, a novel Time Division Multiple Control (TDMC) method to regulate all the outputs in high precision is proposed and applied for the multiple output battery charger based on the phase shift full bridge topology to charge a multiple number of batteries at one time. The proposed converter can charge three different kinds of batteries or same kind of batteries in different state of charges (SOCs) by using constant current/constant voltage (CC/CV) charge mode independently. At the same time it can provide an even degree of tight regulation for each output to satisfy the strict ripple requirement of the battery. The validity and feasibility of the proposed method are verified through the experiments.
Proceedings of the Korea Information Processing Society Conference
/
2000.04a
/
pp.419-422
/
2000
현재의 인터넷은 IPv4를 기반으로 하며, CIDR(Classless InterDomain Routing)을 이용하여 IP의 고갈을 막으려고 노력하고 있다. 그러나, 이는 근본적인 대책이 아니다. 그 때문에 IP는 점차 고갈되어 미래에는 IPv6로 옮겨갈 것이다. 이렇게 IPv6로 발전함에 따라 IP 주소는 매우 늘어날 수 있으나, 출발지 주소와 목적지 주소의 헤더가 커짐에 따라 헤더의 IP 주소를 모두 읽어보는 데에 많은 비용(cost)이 들게 된다. 따라서, 각각의 ISP(Internet Service Provider)들은 MPLS(Multiprotocol Label Switching)를 사용하여 이 문제를 해결하려 노력할 수 있다. 또한, MPLS는 기존의 IP 주소를 이용한 라우팅은 경로를 찾기 위해 필요이상으로 많은 정보를 요구한다고 보고, 레이블 개념을 도입하여 스위칭해주는 역할을 하기 때문에 라우팅을 위해 IPv6로 인하여 더욱 길어진 IP 주소를 요구하지 않고 단지 레이블을 붙임으로 속도를 향상시킬 수 있다. 이러한 환경에서의 이동 IP는 COA를 얻게되면 레이블을 붙여서 목적지까지 전달되게 되고, 이렇게 전달되는 이동 IP에서 COA와 레이블을 합쳐서 하나로 보내는 방식으로 이동 IP의 효율을 높일 수 있다.
Journal of the Korean Institute of Intelligent Systems
/
v.8
no.2
/
pp.43-49
/
1998
This paper describes a phase-shift pulse-width modulation and pulse-frequency modulation seriesresonant high-frequency inverter using IGBT for the power control of high-frequency inductionheating using fuzzy, which is practically applied for 2 0- 5~0 0~~ ~in 1d uction-heating and meltingpov~er supply in industrial fields. The adaptive frequency tracking based phase-shifting PWMregillation scheme is presented in order to minimize switching losses. The trially-producedbreadboards using IGBT are succesfully demostrated and discussed.discussed.
Proceedings of the Korean Institute of Information and Commucation Sciences Conference
/
2014.05a
/
pp.391-394
/
2014
In this paper, we introduce a method of determining the absolute position of the rotor for the vector control of Hall sensor type multi-pole BLDC motor using the DSP(TMS320F28335), and implement an algorithm to complement the problems of the conventional method. The switching method of the inverter for providing desired sinusoidal current to each phase of a motor, we adopt Space-Vector pulse width modulation method. In order to increase the speed range, Field-Weakness control method are used. In order to verify the proposed algorithm, we compare the value of Iqe, Ide and phase currents with the values before compensated.
Kim, Sang-jin;Adhistira, Adhistira;Kim, Kyu-young;Choi, Se-wan;Yang, Dae-ki;Hong, Seok-yong;Lee, Youn-sik;Yeo, In-yong
Proceedings of the KIPE Conference
/
2019.07a
/
pp.68-70
/
2019
본 논문은 8.1kW/L($132W/in^3$)의 전력밀도를 갖는 전기자동차(xEV)용 저전압 배터리 충전기(Low voltage DC-DC converter, LDC)를 위한 절연형 DC-DC컨버터의 설계 방법을 제안한다. 전체 부피 중 가장 큰 비중을 차지하는 자성체의 부피를 줄이기 위해 GaN소자를 채택하여 700kHz의 스위칭 주파수를 적용하였으며, GaN 스위치를 고주파에서 원활히 동작시키기 위한 게이트 드라이버를 직접 제작하였다. 또한 자속 상쇄 개념이 적용된 매트릭스 평면 변압기를 설계하여 적용함으로써 변압기의 부피를 크게 줄일 수 있었고, 8.1kW/L의 전력밀도를 달성하였다. 본 논문에서는 후보 토폴로지들의 비교를 통해 고 전력 밀도에 가장 적합한 토폴로지를 선정하였으며, 자속 상쇄 기법이 적용된 매트릭스 평면 변압기의 설계방법을 제안하였다.
This paper presents a novel fast shut-down scheme for Buck converter by using a coupled inductor. Generally, a controller for Buck converter stops generating PWM patterns in various fault cases: Overcurrent, Short circuit, or Overvoltage, but the inductor and capacitor keep supplying their stored energy to loads although the switching operations in Buck converter stopped. The stored energy in the inductor and capacitor could cause electrical stresses on breakers and safety problems. The main idea of the proposed fast shutdown scheme is to demagnetize the inductor core by using a coupled inductor, and its performance and operations are verified by using PSIM Simulation.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.