• Title/Summary/Keyword: 스위칭기법

Search Result 620, Processing Time 0.029 seconds

An Implementation of a Current Controlled Bi-directional Inverter with ZVT Switching (ZVT 스위칭 되는 전류제어형 양방향 인버터의 구현)

  • 李 星 龍;高 晟 勳;金 成 佑
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.129-136
    • /
    • 2002
  • A single-phase inverter using a diode bridge-type resonant circuit to implement ZVT(Zero Voltage Transition) switching is presented. It Is shown that the ZACE(Zero Average Current Error) algorithm based Polarized ramptime current control can provide a suitable interface between DC link of diode bridge-type resonant circuit and the inverter. The current control algorithm is analyzed about how to design the circuit with auxiliary switch which can ZVT operation for the main power switch. The simulation and experimental results would be shown to verify the proposed current algorithm, because the main Power switch is turn on with ZVT and the hi-directional inverter is operated.

Power Spectrum of Two-Phase and Three-Phase RCD-PWM Scheme for Switching Noise Reduction of Induction Motors (유도모터의 스위칭 소음저감을 위한 2상 및 3상 RCD-PWM기법의 파워 스펙트럼)

  • 위석오;정영국;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.178-186
    • /
    • 2004
  • This paper proposes a two-phase RCD-PWM scheme which is much better than a three-phase RCD-PWM scheme from the standpoint of the broadening and linearizing effect of the power spectrum. To implement the proposed scheme and conventional scheme, the experiment based on the SAB-Cl67 micro-controller was executed. Based on the space vector modulation technique, the duty ratio of the pulses is calculated using the SAB-Cl67 and each of PWM pulses is located randomly in each switching interval. The power spectrum of the output voltage, output current, the d.c link current and the acoustic noise radiated from inverter drives are experimentally investigated. 1'hen, the performance of the proposed scheme was compared and discussed with the conventional scheme.

An Analysis of Baseband Packet Switching Scheme for Multi-Beam Satellite Communications (다중빔 위성통신을 위한 기저대역 패킷 스위칭 기법 분석)

  • Kim, Won-Ho;Lee, Yong-Min;Ku, Bon-Jun
    • Journal of Satellite, Information and Communications
    • /
    • v.5 no.2
    • /
    • pp.97-103
    • /
    • 2010
  • In this paper, we present an efficient design scheme based on analysis of design requirements and considerations of baseband packet switch for S-band satellite/terrestrial hybrid multi-beam satellite communication systems. To establish design requirements and considerations, we analyze required functions of baseband packet switch, specifications of multi-beam satellite communications, communication services and performance requirements. And also we analyze and compare conventional layer-2 and layer-3 satellite baseband packet switching techniques, packet switching protocols and packet switch architectures, to apply from analyzed results. Finally, we propose a hardware design scheme of MPEG based layer-2 baseband packet switch using analyzed results.

A Study on the Dynamic Window Switching MDCT for Enhanced AC-3 Audio Filterbank (다이나믹 윈도우 스위칭기법을 적용한 AC-3 오디오 필터뱅크의 성능향상에 관한 연구)

  • 김준성
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06e
    • /
    • pp.23-26
    • /
    • 1998
  • This paper presents a technique to enhance TDAC in the AC-3 algorithm. To reduce block boundary noise without decreasing the performance of transform coding, new special window adopted. They improves the defect of the AC-3 algorithm that could not properly cancel aliasing in the tansient period. In addition, a fast MDCT calculation algorithm based on a fast Fourier Transform, is adopted.

  • PDF

A Soft switching method for Loss reduction of Inverter (인버터의 손실저감을 위한 소프트 스위칭기법)

  • 곽동걸;김영철;이현우
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.249-252
    • /
    • 2001
  • A large number of soft switching topologies included a resonant circuit have been proposed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this Paper, the authors propose power conversion system, DC-AC inverter of high efficiency and high power factor with soft switching mode by partial resonant method. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source for resonant operation.

  • PDF

Dual Mode Packet Transmission Scheme using a Dynamic Switching Threshold in the IMT-2000 (IMT-2000에서 동적 스위칭 임계점을 이용하는 이중 모드 패킷 전송방식)

  • 김장욱;반태원;오창헌;조성준
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.907-915
    • /
    • 2003
  • A very efficient packet transmission scheme is needed in the radio environment where radio resource is insufficient as compared with the environment of the wired communication. In general, dual mode packet transmission scheme is used broadly. Packets are transmitted through the dedicated or common chamois according to a switching criterion. The general criteria are the length and generation frequency of packet, that is, large and frequent packets are transmitted using a dedicated channel and small and infrequent packets are transmitted using a common channel. The performance of dual mode packet transmission scheme is closely related to the switching criteria. However, it is very difficult to find the optimal switching point because that is not fixed but variable according to the environment such as traffic load, length of generated packets, and the number of channels. In this paper, a new scheme for the dual mode packet transmission scheme using a dynamic switching threshold is proposed where the switching threshold is not fixed but variable according to the network environment. The performance of the proposed method is analyzed using a simulation. From the simulation results, it is shown that the performance of the proposed scheme is not very influenced by the network environment unlike the conventional dual mode packet transmission scheme.

Deduction of TWCs and Internal Wavelengths Needed for a Design of Asynchronous OPS System with Shared or Output FDL Buffer (공유형 혹은 아웃풋 광 지연 선로 버퍼를 갖는 비동기 광패킷 스위칭 시스템 설계를 위해 필요한 가변 파장 변환기 및 내부 파장 개수의 도출)

  • Lim, Huhnkuk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.2
    • /
    • pp.86-94
    • /
    • 2014
  • Optical packet switching (OPS) is being considered as one of the switching technologies for a future optical internet. For contention resolution in an optical packet switching (OPS) system, the wavelength dimension is generally used in combination with a fiber delay line (FDL) buffer. In this article, we propose a method to reduce the number of tunable wavelength converters (TWCs) by sharing TWCs for a cost-effective design of an asynchronous OPS system with a shared or an output FDL buffer. Asynchronous and variable-length packets are considered in the OPS system design. To investigate the number of TWCs needed for the OPS system, an algorithm is proposed, which searches for an available TWC and an unused internal wavelength, as well as an outgoing channel. This algorithm is applied to an OPS system with a shared or an output FDL buffer. Also, the number of internal wavelengths (i.e., the conversion range of the TWC) needed for an asynchronous OPS system is presented for cost reduction of the OPS system.

Burst Assembly Scheme based on SCM for Avoidance of Burst Collision in Optical Burst-Switched Networks (OBS 망에서 버스트 충돌 회피를 위한 SCM 기반의 버스트 생성 기법)

  • 이해정;김영천
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.6B
    • /
    • pp.538-547
    • /
    • 2004
  • Optical Burst Switched (OBS) networks usually employ one-way reservation by sending a burst control packet (BCP) with a specific offset time, before transmitting each data burst frame (BDF). Therefore, The quality of service may be degraded because contentions may lead to loss of BDFs. Especially, this phenomenon becomes more serious when burst size is longer. This necessitates an effective method of prevention to avoid burst collision in nodes. OBS networks can employ several methods to avoid such burst losses. One is that burst size is cut short to reduce burst loss probability during scheduling time. In this paper, we evaluate the burst generation and transmission using Sub-Carrier Multiplexting (SCM) in OBS networks. We propose an appropriate burst assembly architecture and transmission scheme based on SCM in OBS networks. The performance of SCM in OBS networks is examined in terms of number of Sub-Carriers per wavelength, burst loss probability, throughput, and total bandwidth of an optical fiber.

Inverter Drives Adopting the Two-Phase Space Vector SRP-PWM Scheme with Fixed Switching Frequency (고정 스위칭 주파수를 갖는 2상 공간벡터 SRP-PWM기법을 적용한 인버터 구동 시스템)

  • 정영국;위석오;임영철;양승학
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.230-238
    • /
    • 2003
  • In this paper, Inverter drives adopting 2 phase space vector SRP-PWM (Separately Randomized Pulse Position PWM) with fixed switching frequency is proposed. The proposed 2 phase space vector SRP-PWM scheme is based on the 3 phase SRP-PWM. In the proposed SRP-PWM scheme, each of two phase pulses is located randomly in each switching interval. The experimental results show that the voltage and acoustic noise harmonics are spread to a wide band area. Also, the performance of the proposed 2 phase SRP-PWM and the conventional center aligned SVM are compared to each other. In result, the speed response is nearly similar to each other from the viewpoint of the v/f constant control.

A Study on the High Performance PWM Technique for a Propulsion System of Railway (철도차량용 추진제어장치의 고능률 PWM기법에 관한 연구)

  • Min, Byoung-Gwon;Seo, Kwang-Duk;Won, Chung-Yuen
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.186-192
    • /
    • 1998
  • This paper presents a high performance low switching PWM technique or the propulsion system of railway such as subway and high speed train. In order to achieve the continuous voltage control to six-step and s low harmonics with low switching frequency under 500Hz, the synchronous technique is combined with a space vector overmodulation and implemented by using DSP. Improved performance and a validation of proposed method are showed by the digital simulation and the experimental results using a 1.65MVA IGBT VVVF inverter and inertia load equivalent to 160 tons railway cars.

  • PDF