• Title/Summary/Keyword: 순차 운동

Search Result 47, Processing Time 0.021 seconds

A Design of a Distributed Computing Problem Solving Environment for Dietary Data Analysis (식이 데이터 분석을 위한 분산 컴퓨팅 문제풀이환경 설계)

  • Choi, Jieun;Ahn, Younsun;Kim, Yoonhee
    • Journal of KIISE
    • /
    • v.42 no.7
    • /
    • pp.834-839
    • /
    • 2015
  • Recently, wellness has become an issue related to improvements in personal health and quality of life. Data that are accumulated daily, such as meals and momentum records, in addition to body measurement information such as body weight, BMI and blood pressure have been used to analyze the personal health data of an individual. Therefore, it has become possible to prevent potential disease and to analyze dietary or exercise patterns. In terms of food and nutrition, analyses are performed to evaluate the health status of an individual using dietary data. However, it is very difficult to process the large amount of dietary data. An analysis of dietary data includes four steps, and each step contains a series of iterative tasks that are executed over a long time. This paper proposes a problem solving environment that automates dietary data analysis, and the proposed framework increases the speed with which an experiment can be conducted.

Analysis of Processes in Reading about 'Science Stories' in 6th Grade Science Textbook Using Eye-tracking (안구운동 추적 기법을 활용한 6학년 과학 교과서의 과학 이야기 읽기 과정 분석)

  • Park, Hyojeong;Shin, Donghoon
    • Journal of The Korean Association For Science Education
    • /
    • v.35 no.3
    • /
    • pp.383-393
    • /
    • 2015
  • This study analyzed the 6th grade elementary science textbook 'Science stories' reading process of students by utilizing eye movement tracking techniques. Participants read 3 articles in the new experimental science textbooks and solved 9 problems about each article. By understanding and academic achievement results, participants were divided into high-groups, middle-groups, and low-groups. The results of eye movement characteristics of the high-groups and low-groups had the following differences. Number of fixations and number of regressions were higher in high-groups. Average fixation duration and average regressive fixation duration were longer in low-groups. Fixation time for the key sentence of the article was longer in high-groups. Analysis of a scan path and post-interview, high-groups had frequent regression between sentences and they knew where the core of the article is and paid much attention there. In contrast low-groups are sequentially read most articles and some of them had a leap of abnormal range. Problem-solving approach is also different between groups. In conclusion reading style is associated with the science stories comprehension and students who had more regressions, much core search process, effective attention distribution, high concentration showed better understanding results. Also words or sentences used in textbooks are associated with science stories comprehension.

Basin Evolution of the Taebaeksan Basin during the Early Paleozoic (전기 고생대 태백산분지의 분지 진화)

  • Kwon, Yi Kyun;Kwon, Yoo Jin;Yeo, Jung Min;Lee, Chang Yoon
    • Economic and Environmental Geology
    • /
    • v.52 no.5
    • /
    • pp.427-448
    • /
    • 2019
  • This study reconstructed the paleoenvironments and paleogeography of the Taebaeksan Basin, through a review of the previous researches on sedimentology, paleontology and stratigraphy. This study also carried out a sequence stratigraphic analysis on regional tectonism and sea-level fluctuations on the basin during the Early Paleozoic. The basin broadly occur in the Taebaek, Yeongweol-Jecheon, Jeongseon-Pyeongchang, and Mungyeong areas, Gangwon province, South Korea. The basin-fills are composed mainly of mixed carbonates and siliciclastics, divided into the Taebaek, Yeongweol, Yongtan, Pyeongchang and Mungyeong groups according to lithologies and stratigraphic characteristics. Recently, there are a lot of studies on the provenance and depositional ages of the siliciclastic sequences of the basin. The detrital sediments of the basin would be derived from two separated provenances of the core-Gondwana and Sino-Korean cratons. In the Early Cambrian, the Taebaek and Jeongseon-Pyeongchang platforms have most likely received detrital sediments from the provenance of the Sino-Korean craton. On the other hand, the detrital sediments of the Yeongweol-Jecheon platform was probably sourced by those of the core-Gondwana craton. This separation of provenance can be interpreted as the result of the paleogeographic and paleotopographic separation of the Yeongweol-Jecheon platform from the Taebaek and Jeongseon-Pyeongchang platforms. The analyses on detrital zircons additionally reveal that the separation of provenance was ceased by the eustatic rise of sea-level during the Middle Cambrian, and the detrital sediments of the Taebaeksan Basin were entirely supplied from those of the core-Gondwana craton. During that period, sediment supply from the Sino-Korean craton would be restricted due to inundation of the provenance area of the craton. On the other hand, the Jeongseon-Pyeongchang platform sequences show the unconformable relationship between the Early Cambrian siliciclastic and the Early Ordovician carbonate strata. It is indicative of presence of regional uplift movements around the platform which would be to the extent offset of the effects of the Middle to Late Cambrian eustatic sealevel rise. These movements expanded and were reinforced across the basin in the latest Cambrian and earliest Ordovician. After the earliest Ordovician, the basin was tectonically stabilized, and the shallow marine carbonate environments were developed on the whole-platform by the Early Ordovician global eustatic sea-level rise, forming very thick carbonate strata in the basin. In the Late Ordovician, the Early Paleozoic sedimentation on the basin was terminated by the large-scale tectonic uplift across the Sino-Korean platform including the Taebaeksan Basin.

A Method for Vibration and Sensitivity Analysis of Structure Systems with Non-linear Characteristics (비선형 특성을 가진 구조시스템의 진동과 감도해석 방법)

  • Moon, Byung-Young;Kim, Sa-Soo;Iwatsubo, Takuzo
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.4 s.35
    • /
    • pp.10-18
    • /
    • 1999
  • 본 논문에서는 대형구조물의 해석에 있어서 부분구조합성법과 섭동법을 이용하여 복잡한 비선형시스템의 해석방법을 제안하였다. 해석방법은 전체시스템을 먼저 몇 개의 분계로 분할한다. 각 분계의 운동방정식에 비선형항이 존재하여도 전체시스템의 지배적 진동모드는 선형모드라는 가정하에 이 시스템의 각 분계를 모드좌표로 변환한다. 이때, 비선형항은 근사적으로 변환한다. 그리고 섭동법을 이용하여 각 분계의 모드좌표방정식은 섭동좌수별로 정식화되어 순차적으로 구해진다. 비선형의 감도는 비선형계수로 정의되고, 그에 상응하는 강성에 의해 구해진다. 제안된 해석방법으로 비선형회전체, 비선형 베어링-페데스탈로 구성된 대형시계구조물의 진동을 해석하였다. 해석방법의 유효성을 평가하기 위해 응답의 정도와 계산소요시간을 유한요소법의 결과와 비교 분석하였다.

  • PDF

Time-Dependent Nonlinear Analysis of Cable-Supported Prestressed Concrete Frames (케이블로 지지된 PC뼈대의 시간의존적 비선형 해석)

  • Lee, Jae Seok;Kang, Young Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.33-47
    • /
    • 1992
  • A study for the material and geometric nonlinear analysis of segmentally erected cable-supported prestressed concrete plane frames including the time-dependent effects due to load history, creep, shrinkage, aging of concrete, and relaxation of prestressing steel and cable is presented. Updated Lagrangian formulation is used to account for the nonlinear behavior of the structure. For the time-dependent analysis. the time domain is divided into a discrete number of intervals, and a step-forward integration is performed as the solution progresses in the time domain. At each time step. a nonlinear finite element analysis is performed in the space domain. Segmental erection methods are implemented by providing the capability to change the configuration of the structure at any time step of the solution. The computer program CFRAME is developed and a series of numerical examples are presented to study the validity of the program.

  • PDF

Geometric distortion correction of fluorescein ocular fundus photographs (형광 안저 사진의 기하 왜곡 교정)

  • 권갑현;하영호;김수중
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.183-192
    • /
    • 1991
  • Ophthalmoscopy following the intravenous injection of fluorescein has gained great diagnostic importance in ophthalmology. This technique provides sequential evaluation of the anatomic and physiologic status of the choroidal and retinal vasculature. In order to detect the changes between fluorescein ocular fundus image frames, the direct subtraction of the two frames is inadequate because of geometric distortions and background gray level differences in two images. In this study, a scheme for the correction of the geometric distortions is proposed. Precise control point coordinate values for transformation functions are manually determined after the process including a series of blood vessel detection and thinning, and one frame is mapped to another, and then a geometric distortion corrected image is obtained. When the corrected image is used in interframe change detections, a sucessful result is ensured.

  • PDF

Application of Channel Routing Model by Taylor-Galerkin Finite Element Method -Modeling of Flow in Flood- (테일러-갤러킨 유한요소법에 의한 하도추적 모형의 적용 -홍수시 하천 유량 모의-)

  • Lee, Hae-Gyun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.404-410
    • /
    • 2011
  • For the simulation of one-dimensional unsteady flow, the Taylor-Galerkin finite element method was adopted to the discretization of the Saint Venant equation. The model was applied to the backwater problem in a single channel and the flood routing in dendritic channel networks. The numerical solutions were compared with previously published results of finite difference and finite element methods and good agreement was observed. The model solves the continuity and the momentum equations in a sequential manner and this leads to easy implementation. Since the final system of matrix is tri-diagonal with a few additional entry due to channel junctions, the tri-diagonal matrix solution algorithm can be used with minor modification. So it is fast and economical in terms of memory for storing matrices.

Establishment of the Heart Failure Model by Coronary Artery Ligation in Sheep (양에서 관상동맥 결찰에 의한 심부전 모델의 확립)

  • 나찬영;홍장수;박정준;김원곤;강문철;서정욱
    • Journal of Chest Surgery
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • Background: Despite the relatively high mortality rates in the chronic heart failure model induced by coronary artery ligation are relatively high, this model has been a subject of continuos research because of its clinical correlation. Chronic heart failure model of large-sized animals is very useful to analyse mechanical or biological effects on circulatory system which is difficult in small-sized animals. The purpose of this study is to establish the heart failure model by coronary artery ligation in sheep. Material and Method: Among 9 Corridale sheep, the homonymous artery and the diagonal branch were ligated simultaneously in 2 sheep and remaining 7 sheep were assigned to successive ligation of both arteries at an interval of 1 hour. Both coronary arteries were ligated from the point 40% proximal to the apex of the heart. Hemodynamic and echocardiographic parameters were analyzed before the ligation of the coronary artery, after the ligation of the homonymous artery, and after additional ligation of the diagonal branch. The experimental animals were sacrificed after 2 or 3 months of growth and histopathologic studies were performed Result: Immediate postoperative death occurred in the 2 sheep that had received simultaneous ligation of the homonymous artery and diagonal branch. On the other hand, all the 7 sheep that were lifated in succession were survived up to 3 months. Arterial pressure was sifnificantly decreased immediately after ligation of the homonymous artery(p<0.05), and the cardiac output was decreased and pulmonary capillary wedge pressure was increased after further ligation of the diagonal branch(p<0.05). Central venous pressure, pulmonary artery pressure, pulmonary capillary wedge pressure, left ventricular end-diastolic dimension and end-systolic dimension were markedly increased 3 months after ligation of coronary arteries. Anteroseptal akinesia or dyskinesia was developed after the ligation of coronary arteries. Histopathologic study revealed we]1-demarcated ischemic area of fibrosis. Conclusion: Using methods of successive ligation of the homonymous artery and diagonal branch, chronic heart failure model could be reliably established in sheep.

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee, Suk;Lee, Sang-Hoon;Shin, Dong-Ho;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.122-125
    • /
    • 2004
  • In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration gating techniques that can adjust patients' beds by using reversed values of the data obtained. The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range 3 cm ${\sim}$3 m), host computer (RS232C) and stepping motor (torque 2.3Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place in order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data(three dimensional data form with distance of 2cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. The result of analyzing the acquisition-correction delay time for the three types of data values and about each value separately shows that the data values coincided with one another within 1% and that the acquisition-correction delay time was obtained real-time (2.34 ${\times}$ 10$^{-4}$sec). This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultra sonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.

  • PDF

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee Suk;Lee Sang Hoon;Shin Dongho;Yang Dae Sik;Choi Myung Sun;Kim Chul Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.316-324
    • /
    • 2004
  • Purpose : In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration sating techniques that can adjust patients' beds by using reversed values of the data obtained. Materials and Methods : The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range $3\~3$ m), host computer (RS232C) and stepping motor (torque 2.3 Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place In order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data (three dimensional data form with distance of 2 cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. Results : The result of analyzing the acquisition-correction delay time the three types of data values and about each value separately shows that the data values coincided with one another within $1\%$ and that the acquisition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. Conclusion : This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultrasonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.