• Title/Summary/Keyword: 순간수위변화시험

Search Result 12, Processing Time 0.034 seconds

Multiple Slug and Pumping Tests for Quality Enhancement of Hydraulic Parameter Estimates (순간수위변화 및 양수시험을 통한 수리상수 추정의 문제점 분석)

  • 이진용;이강근;정형재;배광옥
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.1
    • /
    • pp.14-22
    • /
    • 1999
  • Slug and pumping tests have been widely used to obtain hydraulic parameter estimates in the field. Although a variety of sources of error and uncertainty can be involved in the course of the test performance and data analysis, serious considerations on these sources are often neglected. In this study these various sources of error and uncertainty are analyzed or discussed using repeated slug and pumping test data and some guide lines are suggested to improve quality of parameter estimates from the slug and pumping tests.

  • PDF

Estimation of Hydraulic Parameters from Slug, Single Well Pumping and Step-drawdown Tests (순간수위 변화시험, 단공양수시험 및 단계양수시험을 통한 수리상수 추정연구)

  • Jo, Yun-Ju;Lee, Jin-Yong;Jun, Seong-Chun;Cheon, Jeong-Yong;Kwon, Hyung-Pyo
    • The Journal of Engineering Geology
    • /
    • v.20 no.2
    • /
    • pp.203-212
    • /
    • 2010
  • The aim in this study is used to develop the remediation technologies for contaminated ground water. Slug, single well pumping and step-drawdown tests have been used to obtain hydraulic parameter estimates in the field. Slug tests yield hydraulic conductivity values using the Bouwer and Rice and C-B-P analysis methods. The mean and median hydraulic conductivity values of Bouwer and Rice method are $4.48{\times}10^{-3}$ and $1.16{\times}10^{-3}cm/sec$, respectively. On the other hand, C-B-P method gave mean and median hydraulic conductivity values of $2.37{\times}10^{-3}$ and $7.09{\times}10^{-4}cm/sec$, respectively. These analyses show a trend for the Bouwer and Rice method to yield lower hydraulic conductivity values in low permeability zones of granite in the study area. Sing well pumping test data were calculated through type curve in GW7, GW12 and MW9 wells. It could be interpreted that the differences of hydraulic conductivity and transmissivity values between GW7 and GW12, MW9 is related with fault clays and fractures in the bedrock among the wells. Step-drawdown tests were carried out in the KDPW1 and KDPW2 wells. The hydraulic parameter of KDPW1 and KDPW2 showed very litter difference between the values. The study of hydraulic parameter estimates can be used to purify in contaminated groundwater.

Estimation of the Effective Hydraulic Conductivity in the Granite Area as an Equivalent Continuum Medium (등연속체매질로서의 화강암지역의 유효수리전도도 산출)

  • 김경수;김천수;배대석
    • The Journal of Engineering Geology
    • /
    • v.12 no.3
    • /
    • pp.319-332
    • /
    • 2002
  • This study is focused on the characterization of an effective hydraulic conductivity in each hydrogeologic unit assumed as an equivalent continuum medium in the granitic area. Four boreholes of 3" diameter were installed and a Multi-packer system was facilitated in the selected borehole. Various in-situ tests including the fracture logging, constant injection and fall-off tests, slug and pulse tests were carried out. A hydrogeologic unit was defined into the upper and lower zones based on the variation of fracture properties and hydraulic conductivities. The difference of the result obtained by the various hydraulic tests and the effective characterization techniques on rock mass permeability are also discussed. The effective hydraulic conductivity of the upper unit was measured by two times(5.27E-10 m/s~7.57E-10 m/s) that of the lower unit(2.45E-10 m/s~6.81E-10 m/s)through the constant injection and fall-off tests.

Hydrogeology and Vulnerability of Groundwater Contamination of a Mountainous Area in Kangwon Province (강원도 흥호리 지역 암반대수층의 수리지질 및 지하수 오염취약성 예비조사)

  • 이진용;이강근;정형재;배광옥
    • The Journal of Engineering Geology
    • /
    • v.10 no.1
    • /
    • pp.27-38
    • /
    • 2000
  • We hydrogeologically studied a mountainous area and its vulnerability to groundwater contamination. Groundwater flow and recharge occur mainly through a network of fractures in this areaTransmissivity and storativity obtained from slug, slug interference, and pumping tests range from 3.2$\times$10$^{-3}$ to 2.0$\times$10$^{-2}$$m^2$/min and 1.3$\times$10$^{-7}$ to 9.15$\times$10$^{-4}$, respectively. The groundwater was contaminated bylivestock activities in the upgradient. The groundwater in the downgradient residential area wasthreatened by the upgradient livestock activities.

  • PDF

Hydraulic Properties of a Coastal Waste Dump in Pohang, Southeastern Korea (포항 지역 해안 투기 매립장의 수리 특성에 관한 연구)

  • 김윤영;강동근;이강근
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 1996
  • Coastal waste dump in Pohang is composed of slags and sludge of POSCO. Hydraulic parameters in the coastal waste dump are very different from those in municipal landfills and general unconsolidated or fractured aquifers. In the waste dump pumping or slug tests are not adequate for the estimation of hydraulic parameters. Time-lag and amplitude of the tidal fluctuation of groundwater table are used to determine the hydraulic parameters. Groundwater table at the groundwater observation wells is about 40 cm higher than the sea level. The contributing factors of the groundwater-rise are estimated. Vertical profile of some chemical constituents in groundwater indicates the gradual transition of the fresh groundwater at the uppermost position to the sea water at the bottom.

  • PDF

Application of SP monitoring to the analysis of anisotropy of aquifer (대수층 이방성 분석을 위한 자연전위 모니터링의 적용)

  • 송성호;용환호
    • Economic and Environmental Geology
    • /
    • v.36 no.1
    • /
    • pp.49-58
    • /
    • 2003
  • To analyze the anisotropic characteristics of fractured aquifer, variations of streaming potential were measured during and after pumping over several wells at the two test sites. Surface electrical resistivity survey, normal resistivity logging, and slug test were performed at the wells to identify the hydrogeological structure. Applying the results to the recently suggested model, the aquifer of the two test sites showed confined characteristics. Anisotropic direction appeared in using equi-potential maps from self-potential monitoring results matched well with the results of the hydrogeological test. The self-potential monitoring method adopted in this study would be useful for providing a more reliable information on the anisotropy of aquifer in the pumping test at single well.

Groundwater Systems in Seoul Area : Analysis of Hydraulic Properties (서울지역 지하수 시스템 조사 : 수리적 특성 분석)

  • 김윤영;이강근;성익환
    • The Journal of Engineering Geology
    • /
    • v.8 no.1
    • /
    • pp.51-73
    • /
    • 1998
  • Hydrogeological systems in a metrnpolitan area can be understood by analyzing the groundwater disturbing factors such as constructions and land applications, the groundwater usage for domestic and industrial purposes, and the groundwater pumpage to lower the groundwater level for the structural safety of subway and underground facilities. This study is part of the study performed to understand the groundwater system in the Seoul area and it is focusing on the hydraulic properties. Groundwater well inventory, barometric efficiency measurements, pumping and slug tests, and long-term groundwater monitoring have been perfonrmed during the last 2 years. The relations between Han River and the groundwater around the river also have been observed. These observations and test data, together with the information on soil distribution, geology, and logging data are used to construct a database and GIS(Geographic Information System) presentation system using ARC/INFO. Barometric efficiencies appeared to have no special trends associated with well depths, which maeans that the degree of confinement of the crystaline rock aquifer of the Seoul area is distributed locally depending on the developrnent of fractures. Hydraulic conductivities exponentialiy decrease with well depth. The stage of Han River fluctuates according to the tidal movement of nearby seawater but the tidal effects attenuate due to the underwater dams. Groundwater levels in the Seoul area seem to have declined for the last two years,but it is not certain that the declination represents the long-term trend.

  • PDF

A Study on the Applicability of the Hydraulic Test Method Performed at an underground Research Facility in Crystalline Rock (결정질 암반내 지하연구시설에서 수행한 현장수리시험법 적용성 연구)

  • Park, Kyung-Woo;Ko, Nak-Yeol;Ji, Sung-Hoon
    • Economic and Environmental Geology
    • /
    • v.53 no.2
    • /
    • pp.121-131
    • /
    • 2020
  • In this paper, the transmissivities obtained from the pulse test, the slug test and the constant head test were compared each other to assess an applicability and a reliability of the hydrogeological test method, which are commonly used to derive the hydrogeological properties of a crystalline rock at un underground research facility. When comparing the results of the pulse test and the slug test, the transmissivities were very similar in the entire test section of the medium. However, there was a little discrepancy in the results in the areas where the permeability is relatively high. The results of the constant head test on the same section showed the lower transmissivity than the results of the pulse test and the slug test on the highly permeable section. This difference in permeability was considered to be due to the difference in the radius of the hydraulic effect applied in each hydraulic test. When the heterogenetic distribution of fracture affects the hydrogeological properties on crystalline rock, it is believed that the hydrogeological characteristics can be explained through a constant head test or a constant flow rate test with a large hydraulic effective radius, as well as a pulse and a slug test that can identify hydrogeological properties in a relatively short time.

Assessment of Depth-averaged Velocity Conversion Factors Using Measured Depthwise Velocities in a Natural River (하천의 수심별 유속측정자료를 이용한 수심평균유속환산계수 산정)

  • Kim, Young-Sung;Lee, Hyun-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.308-308
    • /
    • 2011
  • 하천에서 유량을 산정하기 위해서 전자파표면유속계를 이용하여 표면유속을 측정하고 수심평균유속환산계수 0.85를 일률적으로 적용하여 수심평균유속을 산정하고 있다. 이 수심평균유속환산계수 0.85의 적절성에 대한 논의가 지속되어져 왔으나 그 동안에는 이에 대한 현장검증을 할 수 있는 방법이 없었던 실정이다. 하지만 최근 들어서는 ADCP(Acoustic Doppler Current Profiler)의 하천용 Application인 StreamPro ADCP가 개발되어 이를 이용하면 홍수기에 수심별 유속을 측정할 수 있다. 다만 홍수기에 StreamPro ADCP의 적용시에는 여러 가지 높은 위험성이 상존하는 것은 인지의 사실이지만, 그 외의 별다른 방법이 없는 실정이다. 따라서 홍수기에 StreamPro ADCP를 이용하여 수심별 유속을 측정하고 이와 동시에 측정한 표면유속을 이용하여 수심평균유속환산계수를 산정하여 기존에 환산계수로 적용하고 있는 0.85의 적절성을 파악하고자 하였다. 흐름조건별 수심평균유속환산계수 산정을 위하여 평수기 용담 수자원시험유역의 동향지점에서 수심평균유속환산계수를 산정한 결과 0.632~1.352로 넓게 분포하고 있음을 파악하였다. 이렇게 계수가 실제 적용하는 0.85와는 크게 차이가 나는 이유로는 수심이 얕아서 바닥마찰의 영향이 크기 때문인 것으로 판단되었다. 이에 본 연구에서는 여러 지점에서 홍수기 수심별 유속의 실측을 통하여 수심평균유속환산계수 분포정도를 산정하고자 하였다. 대청댐 상류의 수통수위표가 위치해 있는 적벽대교지점에서 StreamPro ADCP를 이용하여 수심평균유속환산계수를 산정한 결과 0.735~0.986 사이에 분포하고 있다. 측정한 결과의 수심평균유속환산계수의 평균값은 0.853으로 기존에 수심평균유속의 산정을 위하여 적용하고 있는 0.85와 거의 일치함을 보이고 있다. 측정당시 수심이 3.6 m에 이르고 있고 유속 또한 1.55 m/s에 이르고 있어 홍수시 일반하천에서 발생하는 수위와 유속임을 감안할 때, 0.735~0.986의 수심평균유속환산계수는 홍수시 순간적인 변화의 폭이 큼을 알 수 있다. 이렇게 순간적인 변화가 큰 이유로는 난류의 성분이 강해서 나타나는 것으로 이를 평균하면 0.853으로 나타나고 있어 홍수시에 수심평균유속환산계수를 0.85를 사용하여도 무방함을 알 수 있다. 동향지점에서 홍수기에 수심별 유속의 실측을 통하여 수심평균유속환산계수를 산정하고자 하였다. 그러나 이 지점은 강한 와류로 인하여 ADCP가 심하게 흔들림으로 인하여 순간적인 유속의 차이가 최대 4배까지 보임을 알 수 있다. 이로 인하여 수심평균유속환산계수의 범위는 0.233~0.983에 이른다. 측정당시 표면유속이 2.07 m/s 인 것을 감안하여 이 표면유속에 상응하는 수심별 유속 자료만을 이용하여 산정시, 수심평균유속환산계수는 0.876이다. 하천의 하류지점에서 수심별 유속을 측정하여 수심평균유속환산계수를 산정하고자 한강하류로 유입하는 굴포천의 구교 및 박촌1교 지점에서 유속측정을 실시하였다. 이들 두 지점은 홍수기에 조차도 유속이 1 m/s 에 이르지 못하는 지점으로, 수심평균유속환산계수를 산정한 결과 각각 0.826, 0.833을 나타내고 있어, 수심평균유속환산계수 0.85가 홍수기뿐만 아니라 평 갈수기에도 적용할 수 있는 가능성을 확인하였다.

  • PDF

The scale dependent effect of hydraulic conductivity and longitudinal dispersivity in the alluvial aquifer with high permeability (고투수성 충적층에서 수리전도도와 종분산지수의 규모종속효과)

  • Kang, Dong-Hwan;Kim, Tae-Yeong;Kim, Sung-Soo;Kim, Dong-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1899-1903
    • /
    • 2008
  • 대수층의 저유량이 풍부한 강변여과수 개발 예정지역의 충적층(지표면하 $25{\sim}35\;m$ 구간)에서 수리전도도와 종분산지수의 규모종속효과를 규명하기 위해 양수시험과 수렴흐름 추적자시험이 수행 되었다. 양수시험과 추적자시험의 규모는 2 m 와 5 m 이었으며 양수시험은 5개 공, 추적자시험은 3개 공을 이용하여 수행되었다. 양수시험은 일정한 양수율($2,500\;m^3/day$)로 수행되었으며, 양수 시작 후 경과시간에 따른 수위변화 자료를 AQTESOLV 3.5 프로그램에 입력하여 해석하였다. 시험 대수층의 수리전도도는 양수정에서 $1.745{\times}10^{-3}\;m/sec$, 양수정에서 이격거리가 2 m 구간에서는 $2.161{\times}10^{-3}\;m/sec$$2.270{\times}10^{-3}\;m/sec$ 이었으며, 이격거리가 5 m 구간에서는 $2.452{\times}10^{-3}\;m/sec$$2.591{\time}10^{-3}m/sec$로 산정되었다. 그리고, 양수정에서 회복시험 시 Theis(Recovery) 방법에 의해 해석된 수리전도도는 $1.603{\times}10^{-3}\;m/sec$이었다. 양수정에서 관측정의 이격거리(d)에 따른 수리전도도(K) 증가함수는 log K=0.0693 log d-2.671와 log K=0.0817 log d-2.655로 추정되었으며, 결정 계수는 각각 0.965와 0.979로서 매우 높게 나타났다. 따라서 양수정에서의 이격거리가 멀수록 수리전도도가 증가하는 규모종속을 확인하였으며, 또한 시험대수층의 수리전도도가 방사상으로 유사하게 분포하고 있음을 알 수 있었다. 수렴흐름 추적자시험의 양수율은 $2,500\;m^3/day$ 이었으며, 2개의 주입정에 염소이온 5 kg을 순간 주입하였다. 염소이온의 농도이력곡선을 작성하여 초기도달시간과 최고농도의 차이를 분석하였으며, 누적질량회수곡선을 통해 양수 후 경과시간에 따른 염소이온의 질량회수율을 분석하였다. 그리고, 염소이온농도 대 누적질량회수율의 이력그래프를 작성하여 누적질량회수율에 따른 염소이온농도의 증가와 감소 변화를 분석하였다. 또한, 염소이온농도의 증가/감소 구간에 대한 선형회귀분석을 수행하여 농도 증가율과 감소율의 변화를 파악하였다. 양수정에서 관측된 경과시간별 염소이온농도 자료를 CATTI 코드의 "Converging Radial Flow With Instantaneous Injection" 해석법에 적용하여 종분산지수를 추정하였다. 양수정에서 이격거리가 2 m인 경우의 종분산지수는 0.4152 m, 이격거리가 5 m인 경우의 종분산지수는 3.2665 m이었다. 따라서 양수정에서 이격거리가 멀수록 종분산지수가 증가하는 규모종속효과를 확인하였으며, 또한 이격거리에 대한 종분산지수의 비는 각각 0.21과 0.65 정도로서 증가하였다.

  • PDF