• Title/Summary/Keyword: 수평 유지

Search Result 483, Processing Time 0.027 seconds

Centrifuge Modeling on the Deformation Modes of Dredged Clay Slope (준설 점토사면의 변형양상에 관한 원심모델링)

  • Ahn, Kwangkuk;Kim, Jeongyeol;Zheng, Zhaodian;Lee, Cheokeun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.2
    • /
    • pp.19-27
    • /
    • 2007
  • In this study, the centrifugal tests were performed with varying the angle of slope such as 1:3, 1:2.5, and 1:2 in order to analyze the deformation and failure type of dredged clay slope for a short term. The displacement mode, displacement vector and the variation of pore pressure with the different slope angle were measured. As a results, even though the displacement in the slope after 4 months were developed in the case of 1:3 for the dredged slope, there are little problems to obtain the stability of dredged slope because the original construction section maintains. Also, in the case of 1:2.5 after 4 months the local slope failure occurred and in the case of 1:2 after 2 months the circle failure starting from the point of the tensile crack occurred. After reviewing the results, the maximum vertical displacement occurred at the crest of slope and maximum horizontal displacement was about double of maximum vertical displacement.

  • PDF

A Kinematical Analysis of 205B Motion in Platform Diving (플랫폼 다이빙 종목 205B동작의 운동학적 분석)

  • Lee, Chong-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.53-62
    • /
    • 2008
  • The purpose of this research was to analyze the kinematics of the 205B movement in platform diving. For the experiment, 2 athlete from the national diving team were chosen as the subject and two S -VHS video cameras were used. For this diving players preparing for the olympics participated. It was shown that the mean total took $1.112{\pm}0.12s$. In order to perform better, the divers time must be increased, at take off and rotation must be done high up and the horizontal distance must be shorted to main entrance of the water. To enter the water safely, the jump has to be high, the horizontal speed slow and the vertical speed as fast as possible. At E1 the lower limbs change in speed should decrease and after the rotation begins at E2. At take off, the jump is more important than the rotation for the performance of the dive. At take off, the trunk angular velocity was high, and this was needed to jump high for moment of inertia for rotation because for efficient jumping the upper body has to spread out and increase the height of the center of mass.

Compensation for Fast Head Movements on Non-intrusive Eye Gaze Tracking System Using Kalman Filter (Kalman filter를 이용한 비접촉식 응시점 추정 시스템에서의 빠른 머리 이동의 보정)

  • Kim, Soo-Chan;Yoo, Jae-Ha;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.35-41
    • /
    • 2007
  • We proposed an eye gaze tracking system under natural head movements. The system consists of one CCD(charge-coupled device) camera and two front-surface mirrors. The mirrors rotate to follow head movements in order to keep the eye within the view of the camera. However, the mirror controller cannot guarantee the fast head movements, because the frame rate is generally 30Hz. To overcome this problem, we applied Kalman filter to estimate next eye position from the current eye image. In the results, our system allowed the subjects head to move 60cm horizontally and 40cm vertically, with the head movement speed about 55cm/sec and 45cm/sec, respectively. And spatial gate resolutions were about 4.5 degree and 5.0 degree, respectively, and the gaze estimation accuracy was 92% under natural head movements.

Numerical analysis on heat transfer and pressure drop characteristics in a horizontal channel with various ribs (여러 가지 형태의 립이 설치된 수평채널의 열전달 및 압력강하 특성에 관한 수치해석)

  • Kim, Ji-Hoon;Heo, Joo-Nyoung;Ahn, Sung-Hoo;Lee, Doo-Ho;Son, Young-Seok;Shin, Jee-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.40-46
    • /
    • 2013
  • Turbulent flow and heat transfer in a channel with a detached rib array have been simulated. The computations are based on the finite volume method with the SIMPLE algorithm. The forms of ribs considered in this study were rib with rectangular cross section, rib with groove, broken rib, and V-shaped rib. The ribs were deployed transverse or aligned $60^{\circ}$ to the main direction of the flow. Local heat transfer coefficients were obtained at various Reynolds numbers within the turbulent flow regime. Area-averaged data were calculated in order to compare the overall performance of the tested ribbed surfaces and to evaluate the degree of heat transfer enhancement induced by the ribs with respect to the smooth channel. The highest heat transfer occurred for the rib with groove which was aligned $60^{\circ}$ to the main flow direction. Performance factor was decreased with the increase of velocity, and it was found that the best performance factor was obtained in the low velocity region.

The Crack Analysis and Redesign of Horizontal Fin of F-5E/F's External Fuel Tank (F-5E/F 외부 연료탱크 수평 핀 균열 분석 및 재설계)

  • Kang, Chi-Hang;Yoon, Young-In;Jung, Dae-Han
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.4
    • /
    • pp.382-388
    • /
    • 2010
  • In this work the replacement material for magnesium alloy was investigated and an optimized design was suggested for the horizontal fin of a fighter's external fuel tank. For the replacement of magnesium alloy, Aluminum alloy, AL 2034-T351, was selected by considering material properties and its procurement. The strength and fracture toughness properties of AL 2034-T351 are stronger than those of magnesium alloy, but the specific weight of AL 2034-T351 is heavier than that of magnesium alloy by 65%. To meet the allowable limit of C.G. shift in the tank, the design of horizontal fin was optimized by reducing the original shape by 20% and resizing the maximum thickness to 7 mm. From the results of the static and dynamic stress analysis for improving the safety factor of the joint section and the joint hole, the radius of curvature in the aft joint section of the new fin was designed as 8.5mm.

Investigation of Natural Convective Heat Flow Characteristics of Heat Sink (히트싱크의 자연대류 열유동 특성 분석)

  • Jung, Tae Sung;Kang, Hwan Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • To ensure proper functioning of electrical and mechanical systems, cooling devices are of great importance. A heat sink is the most common cooling device used in many industries such as the semiconductor, electronic instrument, LED lighting, and automotive industries. To design an optimal heat sink, the required surface area for heat radiation should be calculated based on an accurate expectation of the heat flow rate in the target environment. In this study, the convective heat flow characteristics were numerically investigated for a vertically installed typical heat sink and a horizontally installed one in free convection using ANSYS CFX. Comparative experiments were carried out to reveal the quantitative effect of the installation direction on the cooling performance. Moreover, the result was analyzed using the dimensionless correlation with the Nusselt number and Rayleigh number and compared with well-known theories. Finally, it was observed that the cooling performance of the vertically installed heat sink is approximately 10~15% better than that of the one in natural convection.

Developmentof Dual Polarized Base station Antenna with Electrical Down tilting (전기적 다운 틸팅 기능을 갖는 이중 편파 기지국 안테나 개발)

  • Lee, Chang-Eun;Yun, Jong-Sup;Moon, Young-Chan;Hur, Jung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.7
    • /
    • pp.81-88
    • /
    • 2004
  • In case of mechanical down tilting, a horizontal pattern is distorted and beam width widens whenincreasing tilt angle, which causes an expansion of hand off region and burden base station equipment. In contrast, electrical down tilting has advantage that horizontal HPBW is kept constant with down tilting. In this paper, based on a phased array technology, dual polarized base station antenna with electrical down tilting was developed at 800MHz band. The antenna has down tilting range of 0$^{\circ}$ to 14$^{\circ}$, and 15㏈i gain. We use stacked microstrip patch as a radiated element and apply balanced feed technique to improve isolation between ports and discrimination of cross polarization. The effect of electrical down tilting was verified by field test.

Diel Horizontal Migration of Planktonic Copepods in the Surf Zone of Yongil Bay, Korea (영일만 쇄파대에 나타나는 부유성 요각류의 주야 수평이동)

  • Suh Hae-Lip;Yu Ok-Hwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.4
    • /
    • pp.527-536
    • /
    • 1996
  • The patterns of diel horizontal migration (DHM) of 7 copepod species are compared as part of a general investigation of the zooplankton adaptations to the surf zone habitats. In a sandy shore surf zone of Yongil Bay, 3 sites such as the bottom and surface of 1 m water depth and water's edge are sampled with a sledge net(n=108). The surf zone copepod assemblage is dominated by 7 species; Acartia hudsonica, Fseudodiaptomus marinus, Paracalanus indicus, Calanus sinicus, Oithona similis, Sinocalanus tenellus and Labidocera bipinnata. Threefold variations in copepod abundance are observed within a diel cycle. Abundances of 7 dominant species and total copepods captured in the surface exhibit significant diel differences, but those taken in the bottom are not significantly affected by diel period. It is shown that about $90\%$ of the surf zone copepods performed DHM. The nocturnal high densities of copepods occurred for a neap tide when the offshore winds prevailed, suggesting the animals' ability for horizontal orientation and an active locomotion without invoking passive transportation by currents. Photoreactive behavior of copepods triggered by relative changes in light intensity may be a primary factor inducing DHM by aggregating in the surf zone during the night and spreading out at day; then copepods may reduce encounters with visual predators. In A. hudsonica, ontogenetic variations in timings of DHM are evident. Such variations are likely to minimize intraspecific competition for diets. Data on shoreward migration of copepods indicate that A. hudsonica, P. indicus, O. similis and S. tenellus can maintain swimming velocities of about $20m\;h^{-1}$ for durations of more than an hour. Our observations of strong diel difference in abundances point out the need for both day and night samplings in surf zone habitats, if the importance of these habitats to planktonic copepods are to be fully understood.

  • PDF

교류형 플라즈마 방전 표시기 방전유지 전압의 전압 상승 시간의 변화에 따른 방전 현상의 변화

  • 김중균;양진호;윤차근;황기웅
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.229-229
    • /
    • 1999
  • 교류형 플라즈마 방전 표시기(AC Plasma Display Panel, AC PDP)의 구동에서의 방전 현상은 기입방전, 유지방전, 소거 방전이 있다. 이중 유지 방전은 표시장치로서의 휘도와 계조의 표현을 위한 방전으로 표시기로서의 효율을 결정하게 된다. 본 연구에서는 유지 방전 전압의 상승 시간의 변화에 따른 방전현상과 휘도, 효율의 변화를 살펴 보았다. 방전 현상에서의 가장 큰 변화는 교류형 플라즈마 방전 표시기의 방전 개시 전압과 방전 유지 전압의 변화이다. 유지 전압의 상승시간이 증가할수록 방전 개시 전압과 방전 유지 전압의 변화이다. 유지 전압의 상승 시간이 증가할수록 방전 개시 전압과 방전 유지 전압의 차(sustain margin)는 감소하여 상승 시간이 1$\mu$s/100V 이상의 영역에서는 방전 개시 전압과 방전 유지 전압이 차이가 없어지게 된다. 이는 방전 유지 전극 위의 유전체에 쌓이게 되는 벽전하(wall charge) 양의 감소에 의한 방전 약화의 영향을 보여질 수 있다. 그러나 방전 유지 전압의 형태와 전류의 시간적인 변화를 살펴보면 이러한 약한 방전은 벽전하의 감소에 의한 방전 시의 전계 감소보다는 방전 전류의 발생 시간이 방전 전압이 증가하여 최고점에 이르지 못한 시간에 위치하여 방전이 형성될 때의 전계가 강하지 못하기 때문인 것을 알 수 있다. 방전 전류를 측정한 결과에 의하면 방전 전류의 시작은 변위 전류가 흐르고 난 후부터 시작되며 그 결과 방전 전류가 최고점에 도달하는 시간은 방전 전압 상승 시간이 길어질수록 낮은 전압에서 형성되게 된다. 또한 방전 유지 전압의 상승 시간이 길어질수록 플라즈마 방전표시기의 휘도와 효율은 낮아지고 이 결과 또한 약한 전계에서의 방전에 의한 결과로 생각되어진다.플라즈마의 강도값을 입력하여 플라즈마의 radiation을 검출하고, 스퍼터링 공정중 실질적인 in-situ 정보로 이용하였다. PEM을 통하여 In/Sn의 플라즈마 강도변화를 조사하였다. 초기 In/Sn의 플라즈마 강도(intensity)는 강도를 100하여, 산소를 주입한 결과, plasma intensity가 35 줄어들었고, 이때 우수한 ITO 박막을 얻을 수 있었다. Pulsed DC power를 사용하여 아크 현상을 방지하였다. PET 상에 coating 된 ITO 박막의 표면저항과 광투과도는 4-point prove와 spectrophotometer를 이용하여 분석하였고, AES로 박막의 두께에 따른 성분비를 확인하였다. ITO 박막의 광투과도는 산소의 유량과 sputter 된 In/Sn ion의 plasma emission peak에 따라 72%-92%까지 변화하였으며, 저항은 37$\Omega$/$\square$ 이상을 나타내었다. 박막의 Sn/In atomic ratio는 0.12, O/In의 비율은 In2O3의 화학양론적 비율인 1.5보다 작은 1.3을 나타내었다.로 보인다.하면 수평축과 수직축의 분산 장벽의 비에 따라 cluster의 두께비가 달라지는 성장을 볼 수 있었고, 한 축 방향으로의 팔 넓이는 fcc(100) 표면의 경우 동일한 Ed+Ep값에 대응하는 팔 넓이와 거의 동일한 결과가 나타나는 것을 볼 수 있다. 따라서 이러한 비대칭적인 모양을 가지는 성장의 경우도 cluster 밀도, cluster 모양, cluster의 양 축 방향 길이 비, 양 축 방향의 평균 팔 넓이로부터 각 축 방향의 분산 장벽을 얻어낼 수 있을 것으로 보인다. 기대할 수 있는 여러 장점들을 보고하고자 한다.성이 우수한 시

  • PDF

Applicability of High-strength Mass Concrete through Setting Time and Horizontally-divided Placement (응결시간제어용 배합과 수평분할을 고려한 고강도 매스콘크리트의 적용성 평가)

  • Cho, Seung-Ho;Paik, In-Kwan;Lee, Dong-Ha;Roh, Young-Sook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.103-113
    • /
    • 2017
  • In the current study, retarding type and standard type admixture design of concrete have been proposed to control the generation of hydration heat for foundation members that use high strengths concrete. Finite element analysis also has been conducted to understand the rational placing heights of concrete. In addition, real-size structures have experimented and their results were compared to the analytical results to evaluate the reducing effect of thermal stress. For a large $6.5m{\times}6.5m{\times}3.5m$ member with retarding and standard type horizontal partition placement of concrete showed the manageable possibility of temperature difference within 25-degree Celcius between the middle and surface portion while the maximum temperature was 77-degree Celcius. Also, temperature cracking index from the finite element analysis appeared to be 1.49 that predicts no formation of cracking due to the effects of temperature. Finally, it appeared that horizontal partition placement of retarding and standard type concrete has the significant effect of reducing the thermal stress that generated by the hydration heat in the high strengths mass concrete.