• Title/Summary/Keyword: 수평채널

Search Result 111, Processing Time 0.02 seconds

Statistical Analysis of VHF Channel Over the Sea Surface for Various Ranges (거리에 따른 해상 초단파 채널의 통계적 특성 분석)

  • Kim, Sea-Moon;Byun, Seong-Hoon;Kim, Seung-Geun;Yun, Chang-Ho;Lim, Yong-Kon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.8B
    • /
    • pp.1021-1027
    • /
    • 2011
  • VHF is generally used for data or voice communications between ships and land stations. Although there exist many analytical and empirical channel models for radio waves on land, over-the-sea models are very limited to basic description. In this paper, a VHF channel is measured using vertical and/or horizontal whip antennas on shore and a moving ship for various ranges. The results show that the Doppler shift and changes in power for various ranges are observed. We can also find that the statistical analysis results in that the statistical parameters are rapidly changes, especially for V/H and H/V channels.

Numerical Study on the Performance of a Microchannel Heat Exchanger with a Novel Channel Array (새로운 채널 배열을 통한 마이크로채널 열교환기 성능 향상 수치 연구)

  • Jeon, Seung-Won;Lee, Kyu-Jung;Moon, Dong-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1119-1126
    • /
    • 2011
  • In conventional microchannel heat exchangers, only one kind of fluid (hot or cold) flows in each plate. The channels contain different kinds of fluid depending on the vertical position, but they have the same kind of fluid at all horizontal positions. Therefore, there is a slower heat transfer rate in the horizontal direction than in the vertical direction. We propose a microchannel heat exchanger in which hot and cold fluid flows alternately in each plate to improve the thermal performance. This novel channel array requires a special design for the inlet and outlet. The proposed channel array has a faster heat transfer rate than a conventional channel array. The thermal performance of the novel channel array increases with increasing Reynolds number and Prandtl number, but it decreases as the ratio of solid to fluid thermal conductivity increases.

Convective Heat Transfer in a Channel with Isothermal Rectangular Beams (등온사각빔이 부착된 채널에서의 대류열전달)

  • Ree, J.S.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.63-72
    • /
    • 1995
  • Convective heat transfer in a two-dimensional horizontal and vertical channel with isothermal rectangular beams attached to one adiabatic wall is investigated from the numerical solution of Navier-Stokes and energy equations. The solutions have been obtained for dimensionless beam spacings, S/L=1~4, aspect ratios of beam, H/B=0.25~4, Reynolds numbers, Re=50~1000 and Grashof numbers, $Gr=0{\sim}5{\times}10^4$. The total mean Nusselt number, Nu_T for horizontal and vertical channels shows same value at Gr=0. As Gr increases, Nu_T for horizontal channel increases, but Nu_T for vertical channel shows similar value at S/L=2, H/B=0.25, Re=100. The total mean Nusselt number for horizontal channel is higher than that for vertical channel. As H/B increases, $Nu_T$ for both channel decrease at $Gr=10^4$, Re=100.

  • PDF

A Performance Analysis and Experiments on Plastic Film/Paper Humidifying Elements Consisting of Horizontal Air Channels and Vertical Water Channels (수평 공기 채널과 수직 물 채널로 구성된 플라스틱 필름/종이 가습 소자의 성능)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.55-63
    • /
    • 2016
  • New materials and shapes for a humidifying element were developed which outperformed the widely used crisscross glass wool Glasdek media design. The new material consists of 50% cellulose and 50% PET. The parallel channel configuration was devised to reduce excessive pressure loss caused by the reduced height (from 7.0 mm to 5.0 mm) of the crisscross configuration. For the same crisscross configuration, the humidification efficiency of the cellulose/PET element was 26% higher than that of the glass wool element. For the same cellulose/PET material, humidification efficiency of the parallel channel configuration was 14% higher than that of the crisscross configuration. As for the pressure drops, the cellulose/PET element was 2-52% higher than those of the glass wool element. For the same cellulose/PET material, the pressure drop of the parallel channel configuration was 14% higher than that of the crisscross configuration. Data were compared against the predictions from existing correlations and those by the proposed model.

Design of a Charge-Coupled Device without Vertical Black Stripes (세로 검은 줄무늬가 없는 전하 결합 소자의 설계)

  • Park, Yong;Lee, Young-Hee
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.4
    • /
    • pp.1100-1105
    • /
    • 1997
  • The verial black stripe is one of the defects in a chrge-coupled device(CCD). Vertical black stripes are caused by some signal chrges which fail to transport form the vertical CCD region to the horizontal one. The defective transport of signal charges orignates in the potential barrier with the narrow width effects in the verti-cal-horizintal interface stuccture. The vertical black stripes show up when the charge transfer dfficiency is less than 99.2% under the low illumination condition. In this research, we designed and developed a new vertical-horizontal interface structre of a delta type, thus marking it possible to eliminate the vertical black stripes.

  • PDF

The Study about Cooling Effect of a Heated module in a Horizontal Channel with a Variation of Channel Height (수평채널 밑면에 부착된 단일 발열모듈에서 채널높이의 변화에 따른 냉각특성 연구)

  • 이진호;유갑종;장준영;김병하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.348-355
    • /
    • 2001
  • The coupled conduction and convection heat transfer from a protruding heated module in a horizontal channel with a variation of channel height is experimentally investigated. The input power to the module is 3, 7W and thermal resistance of module support is 0.06 , 1.03 and 158K/W. the Reynolds number ranged from 350 to 4500 corresponding to the inlet velocity(0.4~1.3 m/s) and channel height(11~35 mm). The results were obtained that the decrease of thermal resistance of module support reduces the module temperature by redistributing the heat flux and the overall thermal resistance of the module. In the study the effect of channel height is very significant in the adiabatic condition, but negligible in the conjugate condition. Finally, correlations for Nusselt number and $Q_B$/Q with a variation of Reynolds number were developed respectively.

  • PDF

Cooling Characteristics of a Parallel Channel with Protruding Heat Sources Using Convection and Conduction Heat Transfer (돌출된 열원이 있는 채널에서 대류와 전도열전달을 이용한 냉각특성)

  • 손영석;신지영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.923-930
    • /
    • 2002
  • Cooling characteristics of a parallel channel with protruding heat sources using convection and conduction heat transfer are studied numerically. A two-dimensional model has been developed for numerical prediction of transient, compressible, viscous, laminar flow, and conjugate heat transfer between parallel plates with uniform block heat sources. The finite volume method is used to solve the problem. The assembly consists of two channels formed by two covers and one printed circuit board which has three uniform heat source blocks. Six different cooling methods are considered to find out the most efficient cooling method in a given geometry and heat sources. The velocity and temperature fields of cooling medium, the temperature distribution along the block surface, and the maximum temperature in each block are obtained. The results are compared to examine the cooling characteristics of the different cooling methods.

Improving the Ownership Regulation in the Broadcasting Industry (방송사업의 소유겸영규제 개선)

  • LEE, Suil
    • KDI Journal of Economic Policy
    • /
    • v.33 no.4
    • /
    • pp.85-118
    • /
    • 2011
  • This paper uses the horizontal regulation system as the base analysis framework. The study clearly defines the regulatory goals of the followings: the horizontal cross-ownership regulations on program provider (PP) and platform provider, the vertical regulation on cross-ownership between PP and platform operator, the regulation on cross-ownership of program provider by terrestrial broadcasting company, and the regulation on cross-ownership between terrestrial broadcasting company and platform provider. Then, by analyzing the conformity between goals and criteria of regulations and the adequacy of the regulation level according to regulatory purposes, this paper examines the justifiability of each regulation and extracts improvement measures that suite regulatory purposes. This analysis finds following appropriate measures: replacing the horizontal cross-ownership regulation on PP with conduct regulations, such as designating major broadcasting programs or replacing the current criterion of cross-ownership regulation from sales to the audience market share; reshaping the horizontal cross-ownership regulation on platform provider so that system operator (SO), satellite broadcaster and Internet protocol television (IPTV) operator would be applied by the same regulation based on the number of subscribers of pay television services; and discontinuing other cross-ownership regulation. In this way, the study shows that with appropriate regulations on cross-ownership of PP, there would be no need for additional regulation on vertical integration between PP and platform operator. On the other hand, given that the regulation on terrestrial broadcasting cross-ownership of PP could be justified only by regulatory purpose of the protection of the diversity of public opinions, it would be desirable to replace the current criteria of the number of PPs with the criteria of the audience market share. Lastly, the study shows that when platform operator is targeted by the cross-ownership regulation based on the number of subscribers of pay television services, the regulation on cross-ownership between terrestrial broadcasting company and platform provider should be replaced with conduct regulations, such as designating must-offer channels and major broadcasting programs.

  • PDF

JBSTC Technique using Space-Time Coding for performance improvement of MIMO Systems (시공간 부호화를 이용한 MIMO 시스템 성능향상을 위한 JBSTC 기법)

  • 박재형;김흥철;이원철
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.29-32
    • /
    • 2002
  • 본 논문은 수평적 시공간 부호화 기법(Horizontal Space-Time Coding)과 송수신단에 별도의 빔형성 기법을 결합한 JBSTC(Joint Beamforming Space-Time Coding) 구조에 대한 제안 및 동작원리를 기술하고 성능을 분석하였다. JBSTC는 MIMO(Multi-Input Multi-Output) 송수신 시스템 채널 모델링을 기반으로 송신측 안테나간 상호 상관 행렬과 수신측 안테나간 상호 상관 행렬을 이용하여 송수신 빔형성기의 안테나 가중치들을 계산한다. 본 논문에서 제안하는 JBSTC 방식은 송수신단에서 발생하는 안테나 간격과 각퍼짐에 따른 상호 상관 값을 효과적으로 보정함으로써 기존의 수평적 시공간 부호화 기법보다 우수함을 알 수 있다.

  • PDF

A Study on Narrow-Band Dual-Mode Channel Filter and Equalizer for Ku band Satellite Transponder (Ku 대역 위성 중계기용 이중모드 협대역 채널 여파기 및 등화기에 관한 연구)

  • 이주섭;엄만석;강승택;박상준;염인복;이성팔
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4B
    • /
    • pp.372-378
    • /
    • 2002
  • In this paper, a narrow-band waveguide channel fitter has been designed and realized for Ku band satellite transponder. Group-delay and amplitude variations of the channel filter have been minimized using a 2-pole reflection type equalizer. The channel filter has been designed to have the 8-pole elliptic response for high frequency selectivity. Dual-mode technique has been adopted for reducing mass and volume of the channel filter and equalizer. The channel filter and equalizer have shown good performance for satellite transponder.