The Digital Orthophoto Production by the Automative Generation of DEM using Non-photogrammetric Scanner (비측정용 주사기를 사용한 수치표고모델의 자동생성에 의한 수치정사사진 제작)

  • Park, Woon-Yong;Yi, Gi-Chul;Lee, In-Soo;Kim, Jin-Su
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.3 no.2
    • /
    • pp.24-36
    • /
    • 2000
  • This study deals with the optimal method of orthophoto products using the non-photogrammetric scanners. we scanned positive film of aerial photographs at the different resolution and producted the orthophoto using the automatically generated DEM based on the Digital Photogrammetric Workstation, considering aerial image resolutions, DEM interval, resampling method and outpixel size. As a results, the acquired accuracy was worse in horizontal, but good in vertical. So It will be expected that orthophoto using non-photo grammetric scanner is good enough for the acquisition of GIS data and the calculation of soil volumes.

  • PDF

Waterhammering on Pump Pipeline Systems (펌프 관로계의 수격현상)

  • 김경엽;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.331-355
    • /
    • 1997
  • 본 연구에서는 에어챔버가 설치된 펌프관로계에서 수격현상에 대한 현장실험을 실시하고, 에어챔버의 입력변수 및 설계인자가 수격현상에 어떠한 영향을 미치는지 수치계산과 실험을 통하여 조사한 후 다음과 같은 결론을 얻었다. (1) 수치계산에 사용된 입력변수중 폴리트로프지수, 오리피스 유량계수, 압력파 전파속도순으로 수격현상에 대한 영향이 크게 나타났으며, 수치계산은 이 변수값이 각각 1.3, 0.7, 1,050m/s일 때 측정된 압력변동 및 공기체적변화를 가장 잘 모사하였다. (2) 에어챔버내 초기공기체적이 증가하면 압축공기의 압력변화율이 작아지기 때문에 수격현상의 주기는 길어지고, 관로내 압력변화는 감소하였다. 측관에 설치한 오리피스 내경을 줄임으로써 상승압은 상당히 완화되었으며, 시간이 지남에 따라 수격작용도 보다 빨리 감쇄되었다. 수치계산결과는 수격현상의 1-2주기까지 측정값과 비교적 잘 일치하였으며, 펌프관로계에 작용하는 최대.최소압력 및 그 발생시간도 합리적으로 예측되었다. (3) 수치계산은 측정된 과도특성 값들을 약 5%이내의 오차로 예측하였으며, 개발된 전산프로그램은 실제 펌프관로계에 대한 수격완화장치를 설계하는데 매우 유용하게 사용될 것으로 판단된다.

  • PDF

Development and Clinical Reliability of a Measuring Device for Bite Force (교합력 측정기기의 개발과 임상적 신뢰도에 관한 연구)

  • Song, Tae-Young;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.3
    • /
    • pp.301-308
    • /
    • 2001
  • 지금까지 여러 가지 형태의 기기를 이용하여 보고된 사람의 교합력은 그 최대치가 매우 다양하다. 본 연구에서는, 교합력을 측정하기 위하여 새로운 측정기기를 개발하였다. 본 기기를 이용하여 전치부 교합력 측정 시에는 대칭적으로 최대한 물도록 하악을 유도하여 최대 교합력을 측정하였고, 구치부는 편측으로 물도록 하악을 유도하여 최대 교합력을 측정하였다. 교합 시 치아간 수직고경은 15.1mm 였다. 측정기기 내 strain gauge를 사용하여 전기저항의 변화를 힘으로 전환하였다. 마이크로 프로세서가 수치를 계산하면 액정화면에 수치가 표시된다. 실험실 내 기기교정 검사에서는 50kg과 100kg의 부하를 가하였다. 개발된 교합력 측정기기의 임상적 신뢰도를 시험하기 위해 건강한 치과대학 재학생 10명을 대상으로 최대 교합력을 측정 하였다. 이 새로운 측정기기로 측정된 교합력은 이전연구에서 기록되었던 것보다 더 높은 수치가 나왔다. 또한 제1대구치와 전치부에서 최대 교합력을 측정한 경우 실험자 내와 실험자 간에 통계적으로 유의한 신뢰성을 얻을 수 있었다. 본 기기는 안정적이고 조작성이 쉽다고 판명되었다. 그러므로, 본 기기는 더 큰 연구 집단의 선별검사에 매우 유용하게 사용할 수 있을 것이며, 또한 치주질환이 있는 치아나 임플란트, 악관절 장애를 가진 환자의 교합력 측정과 같이 특정된 경우의 교합력 측정에도 유용할 것이다.

  • PDF

Experimental Study of Solute Transport in the Unsaturated Zone by using TDR (TDR(Time Domain Reflectometry)을 이용한 비포화영역에서 용존오염원의 거동에 관한 실험적 연구)

  • Park, Jae-Hyeon;Seo, Il-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1998.05a
    • /
    • pp.395-403
    • /
    • 1998
  • 오염원의 이송확산에 관한 많은 연구들이 수행되어 왔으나 특히 비포화 영역에서 오염원 이송확산을 측정하는 것은 매우 어려운 것으로 알려지고 있다. 비포화 토양에서의 오염원 이송확산은 매질의 함수량 변화에 영향을 받기 때문에 오염원 거동특성을 이해하려면 비포화 흐름 분석을 선행한 후 오염원의 이송확산 특성을 분석하여야 한다. 본 연구에서는 비포화 영역에서의 오염원 이송특성을 분석하기 위하여 TDR(Time Domain Reflectometry)을 이용하여 비포화 흐름 및 오염원 이송을 측정하였다. 이를 위하여 본 연구에서는 TDR을 이용하여 오염원 이송을 측정하는 방법을 개발하였으며, 이 방법을 이용하여 1차원의 토양기둥시료에서 비포화 흐름 및 오염원 이송확산에 관한 실험을 수행하고 수치모형을 적용함으로써 비포화 영역에서 오염원의 이송확산에 관한 거동특성을 규명하였다. 본 연구에서는 두 종류의 국내 토양시료(SUS, KUS)를 사용하였는데, 토양의 물리적 특성을 예비실험을 통하여 규명한 후 토양기둥시료를 이용한 본실험을 수행하였다. 비포화 천이흐름하의 오염원 이송확산 실험에서는 급격한 습윤전선의 전진에 따른 종형의 함수량변화를 관측할 수 있었고, 이때 오염원의 농도는 함수량의 천이구간의 중심점으로부터 전방영역의 농도분포가 습윤전선에서의 함수량 분포와 유사한 종형을 이루고 있음을 관측할 수 있었다. 비포화 정상흐름하의 오염원 이송확산 실험에서는 오염원이 이송하며 농도 천이구간이 확장되어지는 전형적인 형태를 보였다. 또한 예비실험에서 측정한 매개변수를 입력자료로하여 수행한 수치결과와 실험결과를 비교하였는데 비포화 흐름특성은 실험결과와 수치결과가 정량적으로 일치하는 경향을 보였으나, 오염원 이송확산 특성은 정량적으로 수치결과가 실험결과보다 더 많이 확산되는 경향을 보였다. 따라서 수치모형을 현장에 적용할 경우 확산지수 결정에 주의하여야 할 것으로 판단된다. 즉, 수치모형에 적용할 확산지수는 BTC 실험을 통하여 측정한 확산지수, 수치확산, 흡착계수, 적용영역의 크기 등을 고려하여 결정하여야 한다. 특히 본 논문에서는 TDR을 이용하여 최초로 천이상태의 함수량과 오염원 농도를 측정하였는데 이를 위하여 전기전도도와 함수량관계를 추정하는 식을 제안하였으며, 전기전도도와 토양수 농도, 전기전도도와 함수량의 관계를 이용한 천이상태의 오염원 농도 측정방법을 개발하였다. 특히 제안식에서는 한계함수량의 개념을 도입하여 전기전도도와 함수량관계를 추정하므로 추정식의 실험값 반영 정도를 증가시켰다. 본 연구에서 제안된 식을 이용하여 추정된 전기전도도와 함수량관계는 다른 제안식에 비하여 개선된 결과를 보여 주었고, 본 연구에서 개발한 오염원 농도 측정법을 이용하여 측정한 결과 함수량이 0.15이하에서는 측정오차가 크지만 함수량이 0.15이상일 경우 매우 좋은 결과를 보였는데 질량평형을 검토한 결과 약 5-10%의 오차율을 보였다. 따라서 본 논문에서 개발된 천이상태의 오염원 농도측정법은 용존 오염물질의 이송에 관한 정확한 실험을 제공할 것으로 판단된다.

  • PDF

Differences in percussion-type measurements of implant stability according to height of healing abutments and measurement angle (임플란트 healing abutment 높이와 타진각도에 따른 타진방식 임플란트 안정성 측정기기의 수치 차이)

  • Park, Yang-Hoon;Leesungbok, Richard;Lee, Suk-Won;Paek, Janghyun;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.278-286
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the effect of healing abutment height and measurement angle on implant stability when using Periotest and AnyCheck. Materials and methods: 60 implants were placed into artificial bone blocks. After implant insertion, 2, 3, 4 and 5 mm healing abutments were installed on 15 specimens, respectively. Insertion torque value, implant stability test, Periotest value were measured. Insertion torque value was controlled between 45 - 55 Ncm. AnyCheck was used for measuring implant stability test and Periotest M was used for measuring Periotest value. Implant stability test and Periotest value were measured at the angles of 0 and 30 degrees to the horizontal plane. Measured values were analyzed statistically. Results: Insertion torque value had no significant difference among groups. When healing abutment height was higher, implant stability test and Periotest value showed lower stability. Also when measurement angle was decreased, implant stability test and Periotest value showed lower stability. Conclusion: When measuring stability of implants with percussion type devices, measured values should be evaluated considering height of healing abutments and measurement angle.

The Enhancements of Sub-pixel Measuring Accuracy by the Centroid Methods (Centroid Methods에 의한 Sub-pixel 측정정확도 향상)

  • 강준묵;배상호
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.2
    • /
    • pp.245-252
    • /
    • 1997
  • The development of digital camera and advancement of computer processor could simplify the acquisition and the analysis of digial image, and be the real-time processing by the digital photogrammetry. This study is about to enhancement of the image measuring accuracy by the centroid methods. We were able to determine more effective centroid measuring methods and suitable target shape as the development of analysis system and actualize semi-automatic measuring of digital image. And we can supply the weakness of non-metric camera for the geometric internal accuracy of digital image as the correct of Kodak DCS200 camera 8008s lens distortion.

  • PDF

A Study of Extensional Viscosity of Fluid M1 in Converging Channel Rheometer Using K-BKZ Intergral Constitutive Equation (수렴관 유변측정기에서 K-BKZ 적분형 구성식을 사용한 M1유체의 신장점도에 관한 연구)

  • 김동회
    • The Korean Journal of Rheology
    • /
    • v.6 no.1
    • /
    • pp.30-40
    • /
    • 1994
  • 고분자 물질의 신장점도를 측정하기 위하여 설계된 수렴관을 지나는 시험 유체 M1 에대하여 유한요소방법으로 수치모사를 수행하였다. 구성방정식은 세 개의 이완시간을 가진 적분형 K-BKZ모형을 사용하였다. 신장변형이 지배적이고 변형속도가 매우 큰 흐름에 대하 여 실험적 방법으로 측정이 가능한 범위까지 수치모사를 수행하였다. 두 개의 압력 측정꼬 지 사이의 벽면 압력차에 대하여 압력 신호로 측정한 실험값을 수치모사결과와 비교하였다. 걷보기 전단속도가 매우 큰 1300s-1에 이르는 높은 유속의 전 실험범위에 대하여 안정된 수 치해를 얻을수 있었다. 3$0^{\circ}C$에서는 모든 실험범위의 유속에서 압력차에 대한 수치모사 결과 가 실험값과 잘일치했다. 21$^{\circ}C$에서는 0.1$\times$10-3m3/s보다 낮은 유속범위에서 실험값과 일치하 는 결과를 얻었으나 그보다 높은 유속에서 실험값과 일치하는 결과를 얻었으나 그보다 높은 유속에서 실험값과 다른 경향의 결과를 얻었다. 이것은 낮은 온도 높은 유속 조건에서 M1 유체의 성질이 불안정하고 또한 그러한 조건의 실험에서 발생한 압력 측정꼭지 부근의 기포 들이 정확한 압력측정에 영향을 끼쳤기 때문이다. 수치모사 결과로부터 얻은 압력과 응력분 포로부터 수렴관 유변측정기의 유동특성을 밝힐수 있었다. 이는 실험적 방법을 통해서는 얻 기 어려운 결과들로서 중요한의미를 가진다. 특별한 모양을 갖도록 설계된 수렴관을 통과하 는 M1 유체가 중심부근에서 일정한 신장변형속도로 변형됨을 확인할 수 있었으며 수직응력 은 지수적으로 증가하다가 축소부분을 지난 후 매우 장점도를 얻기 위하여 신장변형속도가 일정한 구역이 두 배로 확장된 수렴관이 수치적으로 다루어졌고 이를 통하여 기존의 수렴관 에서 구한 값보다 큰 신장점도를 얻을 수 있었다.

  • PDF

Measurement Air Medium Comfort by Temperature and Humidity using Fuzzy Sensor (공기 매질내의 온.습도를 이용한 퍼지센서의 쾌적도 측정)

  • 진현수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.197-200
    • /
    • 2004
  • 본 논문은 공기의 쾌적을 나타내는 항온, 항습의 개념인 공기의 측정 지수를 사람이 체감할 수 있는 단일 항목인 쾌적도라는 항목으로 나타낼 수 있는가를 측정하고 측정지수를 통해 실제 수치로써 쾌적도를 나타내어 보았다. 이는 이제 공기의 습도와 온도를 통해 구체적이지 못한 수치로써 만 나타내어 보이지 않고 함께 작용하는 두 가지 기능을 한가지인 쾌적도라는 지수를 실제 탄생시키고 이를 측정해 보일 수 있는 요소를 퍼지 측도라는 개념을 통해 실현하여 보았다.

  • PDF

The Deformation Measurement of Simulated Ground using Movable Orientation Board for Photogrammetry (사진측량용 이동식 표정판을 이용한 모형지반 변형량 측정)

  • Lee, Hyo-Seong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.4
    • /
    • pp.323-331
    • /
    • 2008
  • Digital close-range photogrammetric technique can measure and describe 3D geometric form from 2D image. This technique is a growing applicability in the field of sciences. Nevertheless, civil and mechanical field, which need measurements as precise as possible, use expensive measuring instruments in general. In addition there are occasions for analysis by means of visual method, since appropriate measuring instruments have been not yet available. This study therefore developed digital close-range photogrammetric technique with a movable orientation board to quickly measure deformation before and after destruction from simulated ground model of reinforced-soil wall. Then the results are compared with the measurements obtained using digital theodolite.

Changes of Serum VEGF, bFGF levels and platelet counts in 100 Cancer Patients treated with Hang-Am-Dan (항암단으로 치료한 암환자 100례의 혈청 VFGF, bEGF 및 platelet 수치 변화)

  • Lee, Nam-Heon;Yoon, Dam-Hee;Yoo, Hwa-Seung;Cho, Jung-Hyo;Son, Chang-Gue;Lee, Yeon-Weol;Cho, Chong-Kwan
    • The Journal of Internal Korean Medicine
    • /
    • v.26 no.4
    • /
    • pp.753-760
    • /
    • 2005
  • 목적 : 본 연구는 100명의 암환자를 대상으로 항암단의 항혈관형성 효과를 측정하기 위하여 고안되었다. 방법 : 100명의 암환자 전체의 치료전후의 VEGF, bFGF 및 혈소판 수치의 변화량을 측정하였고, 병기, 삶의 질 및 암종별로 환자를 나누어 각각의 치료전후의 VEGF, bFGF 및 혈소판 수치의 변화량을 측정하여 통계적 유의성을 살펴보았다. 결과 : 항암단으로 치료한 암환자의 bFGF 수치는 치료전 후 통계적으로 유의성 있게 감소하였다. 특히 유방암 환자에서 bFGF 수치의 감소가 눈에 띄었다. 비록 통계적으로 유의하지는 않았지만 VEGF수치도 항암단으로 치료 후 다소 감소하는 경향을 보였다. 결론 : 따라서 항암단이 암환자 치료에 있어 항혈관형성 약물로써 작용한다고 추론할 수 있다.

  • PDF