• Title/Summary/Keyword: 수치파수조

Search Result 84, Processing Time 0.028 seconds

Numerical Prediction for Overtopping Performance of OWEC (월파형 파력발전장치 OWEC의 월류성능 수치해석)

  • Liu, Zhen;Hyun, Beom-Soo;Jin, Ji-Yuan
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.1
    • /
    • pp.35-41
    • /
    • 2008
  • Overtopping wave energy convertor is an offshore wave energy convertor for collecting the overtopping waves converting the water pressure head into electric power through the hydro turbines. This paper presents a numerical wave tank based on the commercial CFD code Fluent. The Reynolds Averaged Naiver-Stokes and VOF model is utilized to generate the 2D numerical linear propagating waves, which has been validated by the analytical solutions. Several incident wave conditions and shape parameters are calculated in the optimal designing investigation of the overtopping characteristics and discharge for the overtopping wave energy convertor.

  • PDF

Review of Application of VOF-Based NWT on Integrated OWC System (VOF 기반의 수치조파수조를 이용한 OWC 통합시스템 성능연구에 대한 고찰)

  • Liu, Zhen;Jin, Ji-Yuan;Hyun, Beom-Soo;Hong, Key-Yong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.2
    • /
    • pp.111-117
    • /
    • 2012
  • Oscillating water column is the most widely used ocean energy converting systems all over the world. The operating performance is influenced by the efficiencies of the two converting stages in the OWC chamber-turbine integrated system. In order to consider the effects of the turbine, the orifice model are carried out. The VOF based Numerical Wave Tank (NWT) is utilized to simulate the water column oscillation inside the chamber and the results are compared with corresponding experimental data. This paper reviews the state of the art in interaction among wave elevation inside the chamber and air flow rate in the duct, which are considered the turbine effects. Effects of incident wave conditions and several shape parameters on the operating performance of OWC chamber are investigated numerically. The effects of the impulse turbine on the integrated system and interaction among the wave elevation, pressure and air flow velocities variations are investigated.

Effects of Wave Focusing Device on Performance of OWC Chamber (OWC형 파력발전 공기실의 파랑집중장치의 효과에 대한 수치적인 연구)

  • Liu, Zhen;Hyun, Beom-Soo;Hong, Key-Yong;Jin, Ji-Yuan
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.1
    • /
    • pp.12-17
    • /
    • 2010
  • Oscillating Water Column (OWC) device has been widely employed in the wave energy conversion. Wave Focusing Device (WFD) is proposed to be helpful for improving the operating performance of OWC chamber. In the present paper, a Numerical Wave Tank (NWT) using two-phase VOF model is utilized to simulate the generation and propagation of incident regular waves, water column oscillation inside the chamber. The NWT consists of the continuity equation, Reynolds-averaged Navier-Stokes equations and two-phase VOF functions. The standard k- turbulence model, the finite volume method, NITA-PISO algorithm and dynamic mesh technique are employed. Effects of WFD on the operating performance of OWC chamber are investigated numerically.

Numerical Simulation on the Behavior of Air Cloud Discharging into a Water Pool (수조로 방출되는 기포 거동에 대한 수치해석)

  • 김환열;김영인;배윤영;송진호;김희동
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.237-246
    • /
    • 2002
  • If the safety depressurization system of APR-1400, the Korean next generation reactor, is in operation, water, air and steam are successively discharging into a in-containment refueling water storage tank through spargers. Among the phenomena occurring during the discharging processes, the air bubble clouds produce a low-frequency and high-amplitude oscillatory loading, which may result in the most significant damages to the submerged structures if the oscillation frequency is the same or close to the natural frequency of the structures. The involved phenomena are so complicated that most of the prediction of frequency and pressure loads has been resorted to experimental work and computational approach has been precluded. This study deals with a numerical simulation on the behavior of air bubble clouds discharging into a water pool through a sparger, by using a commercial thermal hydraulic analysis code, FLUENT, version 4.5. Among the multiphase flow models, the VOF (Volume Of Fluid) model was selected to simulate the water, air and steam flows. A satisfactory result was obtained comparing the analysis results with the ABB-Atom test results which had been performed for the development of sparser.

Theoretical Study on the Generation of Directional Extreme Waves (다방향 극한파 생성의 이론적 연구)

  • Key-Yong Hong;Shuxue Liu;Seok-Won Hong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.39 no.1
    • /
    • pp.38-48
    • /
    • 2002
  • Theoretical development to generate the directional extreme waves in model basin is established based on wave focusing method. The effects of associated parameters, such as the directional range, frequency width, and center frequency, are investigated in terms of wave focusing efficiency. The two different spectral models of constant wave amplitude and constant wave slope are applied to control the wave characteristics. The wave packets simulated by theory are compared with numerical results based on Boussinesq equation and FEM. Both controls of direction and frequency spectrum are essential to focus directional waves effectively. It is noticed that wave focusing ability depends on the frequency bandwidth of spectrum rather than center frequency, and both spectral models with same parameters result in the equivalent efficiency of wave focusing.

A Study on the Control of Solitary Waves by Resonator (공진장치에 의한 고립파의 제어에 관한 연구)

  • Lee, Kwang-Ho;Beom, Seong-Sim;Kim, Do-Sam;Park, Jong-Bae;An, Seong-Wook
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.1
    • /
    • pp.48-57
    • /
    • 2012
  • In this study, 3-dimensional hydraulic model experiment and 3-dimensional numerical analysis were carried out to review the control performance on the solitary waves by attaching the resonator suggested in this study to the openings of the existing rectangular harbors and breakwaters placed in a straight line. In the numerical analysis, TWOPM-3D of 3-D one-field Model for immiscible TWO-Phase flows method using 3-dimensional numerical wave tank was applied, and the validity of the numerical analysis method was verified through comparative analysis between hydraulic experimental results and numerical analysis results. In addition, the effectiveness of the resonator was identified as a result of review on the control performance to control solitary waves of the resonance devices through comparison with cases where the resonators are attached or not.

Numerical Prediction of Chamber Performance for OWC Wave Energy Converter (OWC 파력발전장치의 공기실 성능예측에 대한 수치적인 연구)

  • Jin, Ji-Yuan;Hyun, Beom-Soo;Liu, Zhen;Hong, Key-Yong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.91-98
    • /
    • 2010
  • The water elevation inside the air chamber and bi-directional air flow in the duct of Oscillating Water Column wave energy converter is one of the most important factors to evaluate the operating performance. The numerical wave tank based on the commercial software Fluent 6.2 in the present paper is employed to generate the incident waves. The numerical wave tank consists of the continuity equations, the Reynolds-averaged Navier-Stokes equations and the two-phase VOF function. The oscillating amplitude of water column in the chamber and bi-directional air flow in the duct installed on the top of the chamber are calculated, and compared with experimental data to verify the validation of the present NWT. The nozzle effects of the chamber-duct system on the relative amplitudes of the inner free water surface and air flow rate in the duct are investigated.

Numerical Analysis of Hydrodynamic Forces on a Floating Body in Two-layer Fluids (밀도가 상이한 두 유체층에서 부유체 동유체력 특성의 수치적 해석)

  • Kim, Mi-Geun;Koo, Weon-Cheol
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.3
    • /
    • pp.369-376
    • /
    • 2010
  • In this study, a radiation and a diffraction problems of a floating body in two-layer fluids were solved by the Numerical Wave Tank(NWT) technique in the frequency domain. In two-layer fluids, two different wave modes exist and the hydrodynamic coefficients can be obtained separately for each mode. The two-domain Boundary Element Method(BEM) in the potential fluid using the whole-domain matrix scheme was used to investigate the characteristics of wave forces, added mass and damping coefficients. The effects of the ratio of density and water depth in the lower domain were also evaluated and compared with given references.

Numerical Analysis of Internal Waves in Two-layer Fluids by a Two-domain Boundary Element Method (Two-domain 경계 요소법을 이용한 해양 내부파의 수치적 재현)

  • Koo, Weon-Cheol;Kim, Mi-Geun
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.6-11
    • /
    • 2009
  • In this study, the internal waves in two-density layered fluids were analyzed using the Numerical Wave Tank (NWT) technique in the frequency domain. The NWT is based on a two-domain Boundary Element Method with the potential fluids using the whole-domain matrix scheme. From the mathematical solution of the two-domain boundary integral equation, two different wave modes could be classified: a surface wave mode and an internal wave mode, and each mode were shown to have a wave number determined by a respective dispersion relation. The magnitudes of the internal waves against surface waves were investigated for various fluid densities and water depths. The calculated results are compared with available theoretical data.

Water Wave Propagation Caused by Underwater Blasting in a 3D Numerical Wave Tank (3차원 수치파동수조에서 수중발파에 의한 수면파의 전파해석)

  • Lee, Woo-Dong;Jeong, Yeon-Myeong;Choi, Kyu-Nam;Hur, Dong-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.364-376
    • /
    • 2019
  • When underwater blasting is conducted, both shock waves and water waves have an effect on adjacent coastal areas. In this study, an empirical formula for estimating the details of water waves caused by underwater blasting was applied to a non-reflected wave generation system, and a 3D numerical wave tank (NWT) was improved to reproduce the generation and propagation of such water waves. The maximum elevations of the propagated water waves were comparatively analyzed to determine the validity and effectiveness of the NWT. Good agreement was demonstrated between the empirical and simulation results. The generation and propagation of water waves were also simulated under each underwater blasting scenario for the removal of the Todo islet at the Busan Newport International Terminal (PNIT). It was determined that the water waves generated by the underwater blasting scenario examined in this study did not have a significant impact on the PNIT. In addition, multiple-charge blasting caused higher wave heights than single-charge blasting. As the amount of firing charge increased, the wave height also increased. Finally, larger water waves were generated during the later blasting conducted at a deeper depth as compared with an earlier blasting conducted at a relatively shallow depth.