• Title/Summary/Keyword: 수축차

Search Result 340, Processing Time 0.026 seconds

EFFECT OF VARIOUS LINERS ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN (수종의 이장재가 복합레진의 중합수축에 미치는 영향)

  • Choi, Ji-Won;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.606-614
    • /
    • 2006
  • The purpose of this study was to evaluate the polymerization contraction of composite resin(Tetric $ceram^{(R)}$, Ivoclar Vivadent Liechtenstein) according to various liners(Tetric $flow^{(R)}$, Ivoclar Vivadent, Liechtenstein/$Ionosit^{(R)}$, DMG, German/ $Vitrebond,^{TM}$ 3M-ESPE, USA). The strain gauge method was used for measurement of polymerization shrinkage strain. Specimens were divided by 8 groups according to curing units and liners. Group A, E: Tetric $ceram^{(R)}$ bulk filing, Group B, F: Tetric $flow^{(R)}$ lining, Tetric $ceram^{(R)}$ filling, Group C, G: $Ionosit^{(R)}$ lining, Tetric $ceram^{(R)}$ filling, Group D, H: $Vitrebond^{TM}$ lining, Tetric $ceram^{(R)}$ filling. Group A, B, C and D were cured using the conventional halogen light($XL3000^{TM}$ 3M ESPE, USA) for 40 seconds at $400mW/cm^2$. Group E, F G and H were cured using light emitted diode(LED) light(Elipar Freelight $2^{TM}$, 3M-ESPE, USA) for 15 seconds at 800 $mW/cm^2$. Strain gauge attached to each sample was connected to a strainmeter. Measurements were recorded at each second for the total of 750 seconds including the periods of light application. Obtained data were analyzed statistically using Repeated measures ANOVA and Tukey test. The results of this were as follows : 1. Contraction stresses in flowable resin and glass ionomer lining group were lower than that in compomer lining group(p<0.05). 2, Contraction stresses in LED curing light groups were higher than that in halogen curing light groups, but there was no significant difference (p>0.05).

  • PDF

A study on the mold design improvement of the clamp chuck by using CAE simulation (CAE 응용설계 기법을 이용한 클젬프 척(Clamp chuck)의 금형설계 개선에 관한 연구)

  • 신명균;허용정;강성남
    • Proceedings of the KAIS Fall Conference
    • /
    • 2000.10a
    • /
    • pp.74-77
    • /
    • 2000
  • 사출성형에 관한 연구는 오랜 역사를 가지고 있으며 공정 시뮬레이션을 위한 상용화된 CAE 프로그램을 포함하여 많은 연구가 진행되는 분야중의 하나이다. 그러나 다양한 고분자 재료의 성질, 금형의 복잡한 형상 및 성형조컨 둥의 변화로 인해 금형설계 및 제작 그리고 사출성형시 상당한 어려움을 겪게 된다. 사출성형 공정에서는 금형온도, 플라스틱 재료, 냉각수, 보압과 사출압 등의 여러 가지 공정변수가 있어 현장전문가의 경험에 의해 사출금형의 제작이 이루어지는 경우가 보통이다 이와 같은 경험에 의한 금형 제작은 상당한 납기지연과 노동집약적인 방식으로 흘러가게 된다. 금형 제작시 가장 고려해야 될 사항 중의 하나는 사출성형품의 수축이다. 사출성형에서 광음수지는 냉각, 고화하면서 수축하는데 성형품 치수를 유지하기 위해서는 수축하는만큼 금형의 치수를 보정하여야 한다. 이 수축률은 사용수지의 종류와 성형품 크기, 살두께 등에 따라 다르다. 또 동일한 수지일 경우에도 성형조건에 따라 변화하고 특히 배향성을 가진 수지는 유동방향에 따라서도 변화가 있다. 즉, 금형의 온도가 높으면 수축률은 증가하고 사출압력이 높으면 감소한다. 또한 살두께가 두껍고 길이가 길 때 수축률은 증가한다 방향성이 있는 수지는 유동방향에 대하여 지각방향에서 가장 적다. 특히 방향성이 현저한 HDP에서는 유동방향에 따라 수축차가 크므로 성형할 때 변형을 일으키는 경우가 많다. 일반적으로 PE, PP. PA와 같은 결정성 수지는 PS, SAM, ABS 등의 비결정성 수지보다 수축률이 크다. 본 연구에서는 한조산업사에서 제작한 '클랠프 척' 금형 제작과정에서 성형품의 수축으로 인한 금형의 치수보정에 있어서의 문제점을 유동해석 전용 CAE 프로그램인 C-mold를 사용하여 해석하고 평가하였다. 그리하여 현장 전문가가 경험적으로 여러 번의 시행착오를 거쳐 완성된 금형을 제작하던 기존의 방법보다 체계적이고 합리적이며 또한 신속하게 문제를 해결함으로써 궁극적으로 금형설계 및 제작기간을 단축하고자 한다.

The Noise Reduction of an Image using Expantion and Contraction Methods (확장과 수축방법을 이용한 차상의 잡음제거)

  • 신충호;오무송
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.04b
    • /
    • pp.664-666
    • /
    • 2002
  • 기울기 연산자나 표면접합에 의한 윤곽추출과는 다른 본 논문에서는 확장과 수축방법론을 이용한 윤곽추출 및 잡음제거 방법론을 제안한다. 제안한 알고리즘은 전처리과정을 거친 후 확장과 수축 방법론을 적용함으로써 영상 윤곽 추출률을 높이고자한다 특히, 기존의 윤곽선 추출방법인 소벨과 프리위트알고리즘은 전처리과정인 미디안필터를 거친 후에 사용하였으며, 제안한 방법은 기존의 윤곽선 추출 필터를 거친 후에 사용하였다. 구체적으로 서술하면 확장알고리즘에서는 일정한 임계치를 초과하면 흰색으로 대치하였고, 수축 알고리즘에서는 검정색으로 대치했다. 기존의 잡음제거과정은 윤곽선의 손실은 없었으나 잡음제거가 소량 이루어졌으며, 제안한 방법에서는 약간의 윤곽선 손실을 보였으나 완전하게 잡음을 제거시킬 수 있었다.

  • PDF

The classification of arrhythmia using similarity analysis between unit patterns at ECG signal (ECG 신호에서 단위패턴간 유사도분석을 이용한 부정맥 분류 알고리즘)

  • Bae, Junghyoun;Lim, Seung-Ju;Kim, Jeong-Ju;Park, Sung-Dae;Kim, Jeong-Do
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.1399-1402
    • /
    • 2011
  • 본 논문에서는 조기 심실 수축과 조기 심방 수축을 검출함에 있어 정밀한 QRS 구간의 폭, 정확한 P파와 T파의 크기 및 위치를 크게 요구하지 않고, 데이터의 가공과 복잡한 알고리즘의 사용에 의해 발생하는 ECG 데이터의 변형과 손실을 최소화할 수 있으며, 또한 개인차 때문에 발생할 수 있는 오류를 최소화하기 위한 알고리즘을 제안한다. 이를 위해 ECG 신호를 각각의 단위 파형으로 분리한 후, 정상 R-R 간격을 가지는 파형을 기준으로 기준파형을 만들어, 각 파형과 기준파형사이의 패턴 대조 및 유사도 분석을 통해 조기 심실수축과 조기심방수축을 검출할 수 있도록 하였다.

A STUDY ON THE EFFECT OF POLYMERIZATION SHRINKAGE OF SEVERAL COMPOSITE RESIN USING STRAIN GAUGE (스트레인 게이지를 이용한 수종 수복재의 중합수축 영향 평가)

  • Lee, In-Cheon;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.20-29
    • /
    • 2009
  • This study was performed to evaluate the effect of the shrinkage stress induced by polymerization process of several light curing filling materials according to filling methods. High power light curing unit which has a plasma arc lamp was used and filling materials used were Filtek $Z-250^{(R)}$ composite resin, $Dyract^{(R)}$ AP compomer and $Tetric^{(R)}$ Flow flowable composite resin. Cavities were prepared on the permanent molars with width 3 mm, height 3 mm and depth 1.5 mm and the filling materials were filled with 1 step, 2 step layering technique and 3 step oblique filling methods. The results can be summarized as follows; 1. Strain values showed rapid increase from the start of light curing followed by gradual decrease afterwards with time. 2. Although the shrinkage stress value of $Z-250^{(R)}$ were shown to be relatively higher than $Dyract^{(R)}$ AP and $Tetric^{(R)}$ Flow, no statistically significant could be found between tested materials(p>0.05). 3. There were no statistically significant difference between 3 filling methods when using $Dyract^{(R)}$ AP and $Z-250^{(R)}$(p>0.05). 4. There were no statistically significant difference between shrinkage stress values obtained from samples prepared by different filling methods and materials(p>0.05).

  • PDF

Physical characteristics of Stocking knitted with Silk/Nylon Compound Yarn (견과 나이론 복합사 스타킹의 품질 특성)

  • Kim, Yeong-Dae;Kim, Nam-Jeong;Song, Gi-Eon
    • Journal of Sericultural and Entomological Science
    • /
    • v.36 no.1
    • /
    • pp.58-61
    • /
    • 1994
  • This study was carried out to investigate the physical characteristics of stocking knitted with silk/nylon(S/N) compound yarn. In SEM observation, it was found that most part of S/N stocking was well interlaced between silk and nylon yarn. There was no difference between S/N stocking and nylon stocking in shrinkage at warm water and compressive resilience. The suction height and absorbability of S/N stocking was 4~8 times and 3 times higher than that of nylon stocking, respectively. According to the wearing test survey, most of wearers answered that the warmth, the hand and the feeling cool of S/N stocking were better than those of nylon stocking but reversed in elasticity, and they gave sprit opinion on durability responding good impression in total feeling of S/N stocking.

  • PDF

Verification of Reliable Blood Pressure Monitor in a Moving Ambulance during an Emergency (응급상황시 이송중인 구급차에서 신뢰할 수 있는 혈압계 검증)

  • Jeon, Jai-In
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.91-97
    • /
    • 2022
  • The purpose of this study was to analyze the measurements of blood pressure and time using manual and automatic blood pressure monitors in various road conditions to verify reliable blood pressure monitor in a moving ambulance. First, the manual blood pressure monitor palpation on unpaved roads showed a systolic pressure deviation of 5 mmHg. However, the automatic blood pressure monitor showed two measurement failures, one reading failure, and the measured systolic pressure deviation was 35 mmHg. The measurement time was 102 seconds faster on average than the automatic blood pressure monitor. Second, the palpation of the manual blood pressure monitor while going over speed bumps remained constant at 130 mmHg. However, the automatic blood pressure monitor had a systolic pressure deviation of 52 mmHg. The measurement time was 61 seconds faster on average than the automatic blood pressure monitor. Finally, the manual blood pressure monitor palpation on the sharp curve road showed a systolic pressure deviation of 5 mmHg. The automatic blood pressure monitor had one reading failure and the measured systolic pressure deviation was 21 mmHg. The measurement time showed that the manual blood pressure monitor was 101 seconds faster than the automatic blood pressure monitor. As a result, in a moving ambulance during an emergency, the manual blood pressure monitor showed high reliability because the blood pressure measurement was constant and the measurement time was short.

A STUDY OF POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN ACCORDING TO FILLING METHODS USING STRAIN GAUGE (스트레인 게이지를 이용한 적층방법에 따른 복합레진의 중합수축에 관한 연구)

  • Kim, Eung-Hag;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.18-29
    • /
    • 2008
  • The purpose of this study was to compare the polymerization shrinkage of several filling methods using strain gauges. In this study, a light-emitting diode(LED) curing unit(Elipar Freeligh2, 3M EPSE, USA) and plasma arc lamp(PAL) curing unit(Flipo, LOKKI, France) were used for curing, Filtek $Z350^{TM}$(3M EPSE, USA) composite resin was used for the cavity filling. Sixty permanent bicuspid teeth, that were extracted for orthodontic treatment, were studied. The cavities were prepared on the occlusal surface and were filled using the following methods : 1) bulk filling, 2) parallel filling, 3) oblique filling The strain was recorded on the buccal, lingual, mesial and distal surfaces and the strain values were computed into stress values. The shear bond strength of each filling method was tested using a Micro Universal Testing machine. The results can be summarized as follows: 1. In the strain changes, all LED and PAL curing groups showed an increase on the buccal surface and a slow decrease as time elapsed. 2. In the strain changes of the mesial and distal surfaces, the decreases and increases were shown repeatedly and reduced as time elapsed. 3. There were no significant statistical strain changes among filling methods in the LED or PAL curing groups. 4. There were significant statistical strain changes between the LED and PAL curing groups on the buccal surface(p<0.05). 5. From the shear bond strength results, in the LED curing group, filling method 3 showed lower surface stress than filling method 1 and 2(p<0.05). In the PAL curing group, there were no significant statistical strain changes between each filling method. 6. The surface stress of each group was lower than the shear bond strength.

  • PDF

A Study on the Changes in Motor Unit Action Potential, EMG Power Spectrum, and Pressure Pain Threshold of Masticatory Muscles during Sustained Fatiguing Contraction (피로를 유발하는 지속적인 근수축 동안 저작근의 운동단위전위, 근전도 power spectrum, 압력통각역치 변화에 대한 연구)

  • Kim, Cheol;Kim, Young-Jun;Kim, Kyung-Nyun
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.3
    • /
    • pp.261-276
    • /
    • 2001
  • 본 연구는 구강안면동통 중에서 빈번히 나타나는 근육성 동통의 주 원인인 저작근의 과활성으로 유발된 근육의 피로 시에 운동단위전위, 압력통각역치, 근전도 power spectrum의 변화 양상과 이들 척도간의 연관성을 조사하기 위해 시행되었다. 두개하악장애의 병력 및 현증이 없고 정상적인 구치부 교합관계를 가진 평균연령 25.8세인 36명의 정상 성인(남자 26명, 여자 10명)을 대상으로 교근과 전측두근의 지속적인 등길이 수축 전후의 압력통각역치 및 운동단위전위를 측정하였고 인내시간까지의 근수축 동안 근전도 power spectrum을 분석하여 다음과 같은 결론을 얻었다. 1. 지속적인 등길이 수축 후 교근과 전측두근의 압력통각역치는 수축 전에 비해 유의하게 감소하였다. 2. 압력통각역치는 수축 전과 수축 후 모두에서 전측두근이 교근보다 유의하게 높게 나타났으며, 전체적으로 남성이 여성보다 높게 나타나는 양상을 보였으나 성별간의 차이는 전측두근의 수축 후 압력통각역치에서만 통계적으로 유의하게 나타났다. 3. 지속적인 등길이 수축말기의 중간주파수는 수축초기에 비하여 유의하게 감소하였고, 전측두근의 수축초기 중간주파수와 수축말기 중간주파수 모두 교근보다 유의하게 높게 나타났다. 4. 교근은 지속적인 등길이 수축 전에 비하여 수축 후의 운동단위전위의 지속시간,진폭, 면적, 상의 4가지 척도에서 유의한 증가를 보였고 전측두근은 진폭을 제외한 나머지 3가지 척도, 즉 지속시간, 면적, 상의 유의한 증가를 보였다. 5. 교근과 전측두근의 지속적인 등길이 수축 전의 압력통각역치와 운동단위전위 척도 사이에는 통계적으로 유의한 상관관계가 없었고 교근에서는 수축 후의 압력통각역치와 운동단위전위의 지속시간, 진폭, 면적, 상 사이에 유의한 상관관계가 존재하였다. 위의 실험결과를 통해 근육피로 검사에 압력통각역치, 근전도 power spectrum 검사 외에 근육수축의 기능적 최소 단위인 운동단위전위의 분석 또한 유용할 수 있고 추후 만성으로 진행된 근막동통환자와 정상 대조군간의 운동단위 수준에서의 비교연구와 근피로에 더욱 민감한 운동단위전위의 다른 척도에 대한 개발과 연구가 필요하다고 사료된다.

  • PDF