• Title/Summary/Keyword: 수직타워

Search Result 29, Processing Time 0.024 seconds

Study on Structural Design of Glass/epoxy Composite Blade and Tower of Vertical Axis Wind Turbine System (수직축 풍력 발전 시스템의 유리/에폭시 복합재 블레이드 및 타워 구조 설계 연구)

  • Park, Hyunbum
    • Composites Research
    • /
    • v.31 no.3
    • /
    • pp.104-110
    • /
    • 2018
  • This study is to propose the structural design and analysis procedure about composite blade and tower of vertical axis wind turbine technology. In this study, structural design of tower for vertical axis wind turbine was performed after vertical blade design and manufacturing. The structural design requirement and specification of blade and tower was investigated. After tower of structural design, the structural analysis of the tower was conducted by the finite element method. It was performed that the stress, deformation and natural frequency analysis at the applied loading. The design modification of tower configuration was proposed by structural analysis. It was confirmed that the final designed tower structure is safety through the structural analysis.

Optimum Design of a Wind Power Tower to Augment Performance of Vertical Axis Wind Turbine (수직축 풍력터빈 성능향상을 위한 풍력타워 최적설계에 관한 연구)

  • Cho, Soo-Yong;Rim, Chae Hwan;Cho, Chong-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.3
    • /
    • pp.177-186
    • /
    • 2019
  • Wind power tower has been used to augment the performance of VAWT (Vertical Axis Wind Turbine). However, inappropriately designed wind power tower could reduce the performance of VAWT. Hence, an optimization study was conducted on a wind power tower. Six design variables were selected, such as the outer radius and the inner radius of the guide wall, the adoption of the splitter, the inner radius of the splitter, the number of the guide wall and the circumferential angle. For the objective function, the periodic averaged torque obtained at the VAWT was selected. In the optimization, Design of Experiment (DOE), Genetic Algorithm (GA), and Artificial Neural Network (ANN) have been applied in order to avoid a localized optimized result. The ANN has been continuously improved after finishing the optimization process at each generation. The performance of the VAWT was improved more than twice when it operated within the optimized wind power tower compared to that obtained at a standalone.

An Experimental Study for Efficient Design Parameters of a Wind Power Tower (풍력타워의 효율적인 설계변수에 대한 실험적 연구)

  • Cho, Soo-Yong;Choi, Sang-Kyu;Kim, Jin-Gyun;Cho, Chong-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.2
    • /
    • pp.114-123
    • /
    • 2018
  • Wind power tower (WPT) has been used to augment the performance of vertical axis wind turbine (VAWT). However, the performance of the WPT depends on several design parameters, such as inner and outer radius, or number of guide walls. Therefore, an experimental study was conducted to investigate efficient design parameters on the WPT. A wind tunnel was utilized and its test section dimension was 2m height and 2.2m width. One story model of the WPT was manufactured with seven guide walls and a VAWT was installed within the WPT. Three different sizes of guide walls were applied to test with various design parameters. The power coefficients were measured along the azimuthal direction in a state of equal inlet velocity in order to compare its performance relatively. The experimental results showed that the gap between the inner radius of the WPT and the rotating radius of the VAWT was a major parameter to improve the performance of VAWT within the WPT.

Strength Evaluation of T-type Tubular Joints for Circular Section Multi-Column Wind Towers (원형단면 멀티기둥 풍력타워 적용 T형 강관조인트 강도 평가)

  • Kim, Kyung Sik;Park, Hyun Yong;Seo, Dong Hyuck
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.1
    • /
    • pp.119-129
    • /
    • 2015
  • Due to reduced self weight and alleviated wind effect, the multi-column wind towers that consist of a number of circular tubes as vertical members interconnected with horizontal brace members can be a substitute for the large-scale single cylinder wind towers. It is critical to guarantee strengths of tubular joints where vertical and horizontal members are structurally connected in order to make the whole multi-column system behave as a single tower structure. In this study, strength evaluation has been conducted for T-type tubular joints that are applicable in multi-column towers. Four of available design codes, i.e., AISC, Eurocode3, ISO 19902, CIDECT have been investigated and predictor equations in the considered design codes were validated and discussed through parametric numerical study on slenderness ratios of chords and braces at joints.

Ultimate Strength Interaction of Steel Tubular T-Joint Subjected to Concurrent Action of Compression and Bending (압축과 휨을 동시에 받는 강관 T조인트 극한강도 상호작용)

  • Kim, Kyung-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.298-303
    • /
    • 2016
  • Owing to the advantages of reduced weight and wind effect, the space-framed towers that consist of vertical and horizontal members of circular hollow tubular sections have been adopted widely for various purposes. It is critical to guarantee the strengths of tubular joints where vertical and horizontal members are connected structurally to make the entire space-framed system behave as a single tower structure. In this study, a strength evaluation was conducted for T-type tubular joints subjected to the concurrent action of compression and bending. Three of the available design codes, i.e., AISC, Eurocode 3, ISO 19902 were investigated and a design equation was suggested for an ultimate strength interaction between the axial force and bending moment based on nonlinear finite element analyses by selecting the slenderness ratios at the joints as major parameters.

Illuminance Distribution Analysis by Lighting Tower Position of o Soccer Stadium (축구 경기장의 조명타워 위치에 따른 조도분포 해석)

  • 김길영;최홍규;최병숙
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Nowadays the soccer becomes one of the best spot lighting sports in the world Especially the 2002 Korea-Japan World Cup was deeply impressed on all the korean. One goal of illuminating engineering should be the design of lighting system that can provide consistently high task visibility regardless of where a task might be located within a working space. The television broadcasting on the soccer has been an important role in the media. The standard of FIFA(The Federation Internationale do Football Association) requires recommended illuminance levels for artificial lighting for a player, an audience, TV broadcasting, as well as everybody in the stadium. This paper has proposed an algerian to select the suboptimal lighting tower position for watching and TV broadcasting a soccer game within a pleasant environment and an optimum illuminance distribution. The position using the software Philip's Calculux was chosen based an the calculations of a horizontal illuminance, vertical illuminance, uniformity, glare, and so on by changing lighting tower positions.

Proposal of a prospective public convenience through vertical division of space;TOILET TOWER (공간의 수직분할을 통한 미래형 공중화장실 제안;타워식 화장실)

  • Son, Bo-Ra
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.212-215
    • /
    • 2006
  • The Beautiful rest room is simple how to think. We need to understand that excretion is important as much as eating. When we didn't have foods, eating was important in itself no matter what our lives environments. But now we want to eat in more dignified and more cultural place. Most of restaurants spend money on adjusting place for the consumes' desire. It is same way about rest room, it is time to change our rest room to place of rest and speculation over the place which we fix our natural urge. We can fix our natural urge, take a rest, and get creative ideas in more convenient, more healthy and more comfortable. It is time for us to change out thought about rest room; it is not dirty and stink place, but civilized living place like developed country. Also, we need new concept to take a triangular position about rest room is one of structure over just decorations. This research suggest new public rest room without precedent based on instance analysis about rest room inside and outside the country.

  • PDF

A Model on the Stability Analysis of Supporting Structure of Climbing-Type Tower Cranes (상승식 타워크레인 지지구조의 안정성 검토 모델)

  • Ho, Jong-Kwan;Kim, Ah-Young;Kim, Sun-Kuk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.2
    • /
    • pp.190-198
    • /
    • 2008
  • Recently construction equipments have been used in line with building the structures that have become taller, larger and complex. And as the works at the elevated level for apartment and residential-commercial building projects have been on the rise, the number of tower cranes mobilized tends to be increased too. Due to such an increase in using the equipment serves the critical factor for the project management. The climbing-type tower crane, which increases its height following the structure, has been increased and the need for selecting the optimal model has been increasingly Important in securing the stability. The study hereby proposes the model to evaluate the stability of the climbing-type tower crane. The model was designed to assist in selecting the type of crane as well as in developing the design of Collar comprising the 3 types of support member, evaluating the stability and designing the embed. The model proposed is expected to make commitment in selecting the optimal type of equipment and evaluating the support member and embed for enhancing the stability, thereby ultimately enabling to implement the prefect in efficient way.