• Title/Summary/Keyword: 수직온도분포

Search Result 147, Processing Time 0.027 seconds

An Experimental Study of Supersonic Underexpanded Jet Impinging on a Perpendicular Flat Plate (평판 위에 충돌하는 초음속 과소팽창 제트에 관한 실험적 연구)

  • 이택상;신완순;이정민;박종호;김윤곤
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.3
    • /
    • pp.53-61
    • /
    • 1999
  • Impinging jets are observed when exhaust gases from missiles or V/STOL aircrafts impinge on the ground, flame deflector, ship deck, etc. The flow shows different patterns according to the nozzle geometry, nozzle-to-plate distance, and plate angle, for example. This paper describes experimental works on the phenomena (pressure distribution, occurrence of stagnation bubble, and so on.) when underexpanded supersonic jets impinge on a perpendicular flat plate using a supersonic cold-flow system, and compares the results with those obtained using a shock tunnel. The flow characteristics for the supersonic cold-flow system were also investigated. Surface pressure distribution of supersonic cold-flow system differed from that of shock tunnel because of water and temperature in the low-pressure chamber. Surface pressure distribution as to underexpanded ratio showed similar patterns together.

  • PDF

Development of Scientific Payloads for Korea Sounding Rocket-III (3단형 과학로켓용 과학탑재체 개발)

  • Hwang, Seung Hyeon;Kim, Jun;Lee, Su Jin;Jeon, Yeong Du;Park, Jeong Ju
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.80-88
    • /
    • 2003
  • This paper describes the development of an ozone detector and an electron probe as parts of scientific payloads for sounding rockets such as the KSR-III. Each detector consists of sensor parts and electronic parts. We successfully carried out the calibration tests with developed ozone detector and the space plasma simulation chamber tests with electron detector. These payloads could be onboard the KSR-III and with measured data, it is expected and temperature profile over the Korean Peninsular.

The Study on Thermal Characteristic of the Balcony with Natural Ventilation System (자연환기시스템을 부착한 발코니의 열적 특성에 관한 연구)

  • Cho Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.347-354
    • /
    • 2005
  • This paper compared vertical temperature distribution between the existing balcony model without ventilator facilities and the improved balcony model with ventilator facilities using differential equation. As the air inside of balcony is heated by solar radiation this heated air is not exhausted in the existing balcony, remaining stagnant. The air temperature distribution was $26.7{\sim}29.3^{\circ}C$ in balcony without natural ventilator system. This heated air affected the rising air temperature of adjacent spaces such as living room and bedroom in the existing balcony. But, as the heated air inside of the improved balcony model is exhausted through natural ventilator facilities in summer, the air temperature in balcony has fallen. The air temperature distribution in improved balcony was $24.8{\sim}26.7^{\circ}C$ for the inlet air speed of 1 m/s and $24.6{\sim}26.7^{\circ}C$ for the inlet air speed of 3 m/s. The energy consumption of the improved balcony is 2.5 times less than of the existing balcony. The improved balcony with the closed damper makes a roll as the existing balcony in the aspect of the heating effect. When the heated air in the improved balcony is supplied, the air temperature is raised and the ventilation effect in adjacent spaces was improved.

The Effect of Impact Velocity on Droplet-wall Collision Heat Transfer Above the Leidenfrost Point Temperature (Leidenfrost 지점 온도 이상에서 액적-벽면 충돌 열전달에 대한 충돌 속도의 영향)

  • Park, Jun-seok;Kim, Hyungdae;Bae, Sung-won;Kim, Kyung Doo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.567-578
    • /
    • 2015
  • Single droplet-wall collision heat transfer characteristics on a heated plate above Leidenfrost temperature were experimentally investigated considering the effects of impact velocity. The collision characteristics of the droplet impinged on the heated wall and the changes in temperature distribution were simultaneously measured using synchronized high-speed video and infrared cameras. The surface heat flux distribution was obtained by solving the three-dimensional transient heat conduction equation for the heated substrate using the measured surface temperature data as the boundary condition for the collision surface. As the normal impact velocity increased, heat transfer effectiveness increased because of an increase in the maximum spreading diameter and a decrease in the vapor film thickness between the droplet and heated wall. For We < 30, droplets stably rebounded from a heated wall without breakup. However, the droplets broke up into small droplets for We > 30. The tendency of the heat transfer to increase with increasing impact velocity was degraded by the transition from the rebounding region to the breakup region; this was resulted from the reduction in the effective heat transfer area enlargement due to the breakup phenomenon.

Study on the Productivity of Microalgae Nannochloropsis sp. Using the Highly Efficient Vertical Photobioractor (수직형 고효율 광배양기를 통한 미세조류 Nannochloropsis sp.의 생장성 연구)

  • Kim, Young-Nam;Chung, Myung-Hee;Kim, Eun-Joo;Karnadi, Vita;Kim, Young-Jun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • We have investigated the productivity of microalgae, Nannochloropsis sp., using highly efficient vertical photobioreactor which has been developed by the company IMBiz. This experiment was performed in the field for one month with 2 sets of 2 tons of media under autotrophic cultural mode. In the culture with 0.1% of $CO_2$, the average daily productivity was shown to be up to 0.953g per liter, and 0.574g per liter in the culture with only ambient air. The temperature ranged from $20^{\circ}C$ to $31^{\circ}C$, and it didn't make any differences on the productivity. The light intensity ranged from 5,000 Lux to 40,000 Lux. The light has been appeared to have a very close relationship with the productivity of microalgae. Meanwhile, the harvesting method of pressurefloating attempted in this photobioreactor was found to be very effective.

The Throughflow Effects on Natural Convection in Horizontal Porous Layer (수평 다공층에서 수직 관통류가 자연대류 열전달에 미치는 영향에 관한 연구)

  • 서석진
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.209-215
    • /
    • 1998
  • This paper investigated the vertical throughflow effects on natural convection due to heating from below in horizontal porous layer. The motion of the fluid in the porous layer is governed by Brinkman-Darcy equation. And compared Critical Rayleigh number in case of throughflow with no throughflow. Investigated Nusslet number, isothermalline and flow with the variation of the strength of throughflow in a constant Rayleigh number. In the numerical analysis, flow is assumed to be two-dimensional and unsteady. The numerical scheme used is a finite-difference method. In the experimental study, Temperature distribution was measured by use of Liquid Crystal film. As a results, indicated that throughflow influences largely on the temperature field and as the strength of throughflow increased, unstability of natural convection decreased. Also it could predict the strength of natural convection with the measured Nusselt number.

  • PDF

Application of Horizontal Barrier on a Rack to Reduce Fire Spread (화재확산 저감을 위한 랙크 내 수평차단막 적용에 관한 연구)

  • Yeo, In-Hwan;Cho, Gyu-Hwan
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.71-79
    • /
    • 2017
  • A rack warehouse with a vertically loading type and high loading density has severe risks and damage during its fire. In this regard, US and Japan strive to minimize the fire spread by applying in-rack sprinkler, horizontal barriers, etc. corresponding to their own rack warehouse but there is no study and policy in Korea. Therefore, a model scale fire test was carried out targeting the standard rack incorporating the national rack warehouse in order to check fire characteristics in ignition points and installation distances of horizontal barriers in this study. As a result of the test, vertical fire spread of about 30% was inhibited by narrowing its installation distance from 2-layer to 1-layer in an ignition condition of the flue space. In addition, as a result of the measurement of the temperature in the upper and lower parts of the horizontal barrier, the temperature distribution showed about 2~4 higher in a condition with an installation of the barrier than that in the condition without the barrier. Consequently, it is likely that the horizontal barrier will help the initial operation of in-rack sprinkler.

A Study of Mixed Convection on a Flat Plate with an Unheated Starting Length (비가열부가 있는 평판에서의 혼합대류에 관한 연구)

  • 김민수;강영규;백병준;박복춘
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1304-1312
    • /
    • 1993
  • The buoyancy effects on mixed convection heat transfer over a flat plate surface with unheated starting length is reported. The governing equations are solved by a finite difference method using Patankar scheme and the solution was numerically obtained for various mixed convection parametr $Gr_{x}/Re_{x}^3$, and Prandtl number of 0.7 Local heat flux was measured by using Schilieren Interferometer. The local heat transfer results show that the presence of the unheated starting length can significantly accentuate the effects of buoyancy. The degree of accentuation of the buoyancy effects is strongly influenced by the magnitude of $Gr_{x}/Re_{x}^3$. When the parameter is larger than the order of $10^{-3}$, the contribution of natural convection to the heat transfer coefficients increased significantly due to the unheated starting length. In contrast, when $Gr_{x}/Re_{x}^3$ is smaller then about $10^{-5}$ , the buoyancy contribution is essentially unaffected by the unheated starting length. The shape of the velocity profile is also found to be highly responsive to the interaction between the buoyancy and the starting length.

Effect on Thermal Performance of Superheater Module under Part Load Operation in HRSG (배열회수보일러의 부분부하 운전에 따른 유동불균일이 과열기의 성능에 미치는 영향)

  • Chong, Chae-Hon;Song, Jung-Il
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.161-166
    • /
    • 2008
  • The purpose of this study is to apprehend the behavior of exhaust gas flow from gas turbine during part load operation in Heat Recovery Steam Generator. As a first step of this work, internal flow characteristics according to HRSG types were examined by CFD analysis. Next step, tube temperature according to gas turbine 53% and 100% load conditions were calculated by results of CFD and those were compared with temperature data gathered from real plant. Finally, thermal performance due to part load operation was calculated to estimate the influence of heat transfer in superheater. In addition, new type of device is suggested to eliminate the uneven temperature distribution of tubes during part load operation.

Analysis of Stratified Lake using an Eddy Diffusion and a Mixed-Layer Models (와확산 및 혼합층 모델을 이용한 성층화 호수 해석)

  • 김경섭
    • Water for future
    • /
    • v.29 no.5
    • /
    • pp.235-244
    • /
    • 1996
  • A one-dimensional eddy diffusion model and a mixed-layer model are developed and applied to simulate the vertical temperature profiles in lakes. Also the running results of each method are compared and analyzed. In an eddy diffusion model, molecular diffusivity is neglected and eddy diffusivity which does not need lake-specific fitting parameter and constant lake's level are applied. The heat exchanges at the water surface and the bottom are formulated by the energy balance and zero energy gradient, respectively. In a mixed-layer model, two layers approach which has a constant thickness is adopted. Application of these models which use explicit finite difference an Runge-Kutta methods respectively demonstrates that the models efficiently simulate water temperatures.

  • PDF