핵의학과 PET/CT실 방사선작업종사자의 수정체 부위의 등가선량과 흉부의 유효선량의 측정 비교 (Comparison of the Equivalent Dose of the Lens Part and the Effective Dose of the Chest in the PET/CT Radiation Workers in the Nuclear Medicine Department)

  • 손상준;박정규;정동경;박명환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권3호
    • /
    • pp.209-215
    • /
    • 2019
  • Comparison of the effective dose of the chest and the equivalent dose of the lens site in the radiation workers working at four medical institutions with the PET / CT room located in one metropolitan city and province from April 1 to June 30, 2018 Respectively. Radioactive medicine were measured at the time of dispensing and at the time of injection. In this experiment, the average dispensing time per patient was 5.7 minutes and the average injection time was 3.1 minutes. The equivalent dose at the lens site was $0.78{\mu}Sv/h$ for 1 mCi, and the effective dose for chest was $0.18{\mu}Sv/h$ per 1 mCi. The equivalent dose at the lens site during injection was $0.88{\mu}Sv/h$ per mCi and the effective dose of chest was $0.20{\mu}Sv/h$ per mCi. The daily effective dose of the chest was $0.9{\pm}0.6{\mu}Sv$ and the equivalent dose of the lens site was $3.6{\pm}1.4{\mu}Sv$ during daily dosing for 20 days. The effective dose of the chest during the day was $0.6{\pm}0.5{\mu}Sv$ and the equivalent dose of the lens was $2.2{\pm}1.0{\mu}Sv$. At the time of dispensing, the equivalent dose of the lens was $0.187{\pm}0.035mSv$, the effective dose of the chest was $0.137{\pm}0.055mSv$, the equivalent dose of the lens was $0.247{\pm}0.057mSv$, and the effective dose of the monthly chest was $0.187{\pm}0.021mSv$. As a result of the corresponding sample test, the equivalent dose and the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, The equivalent dose of the lens and the effective dose of the chest were statistically significant (p<0.05) with a significance of 0.000. However, there was no statistically significant difference (p>0.05) between the equivalent dose and the effective dose of the chest, the equivalent dose of the lens at the time of injection, and the effective dose of the chest at 0.138 and 0.230, respectively.

전산화단층촬영에서 촬영 목적 부위와 주변 결정장기에 대한 피폭선량 평가: 선량 권고량 중심으로 (Evaluation of Radiation Exposure Dose for Examination Purposes other than the Critical Organ from Computed Tomography: A base on the Dose Reference Level (DRL))

  • 이서영;김경리;하혜경;임인철;이재승;박형후;곽병준;유윤식
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.121-129
    • /
    • 2013
  • 최근 다중검출기 CT의 보편화 된 사용으로 환자의 피폭선량이 증가하고 있다. 따라서 광자극발광선량계를 이용해 촬영 목적 부위와 주변 결정장기에 대한 환자의 피폭선량을 측정하고 그에 따른 생물학적 효과를 예측하여 저감화 방안을 제시하고자 하였다. ICRP에서 권고한 표준안을 대상으로 만들어진 인체 모형 표준 팬텀에 교정상수를 부여받은 OSD 선량계를 측정하고자 하는 좌 우 수정체, 갑상선, 촬영의 중심점, 생식선에 부착하여 각 검사 부위별 노출 조건과 동일한 상태에서 환자의 피폭 선량을 모사하였다. OSL 선량계의 평균 교정상수는 $1.0058{\pm}0.0074$이었으며 검사 부위별 주변 결정장기의 등가선량은 좌 우측 수정체의 경우 직접 피폭이 약 50mGy로 최대였으며 간접 피폭되는 경우 0.24mGy, 원거리에서는 0.005mGy미만의 기준 준위 이하로 측정되었다. 갑상선의 경우 두부 검사에서 10.89mGy로 최대였으며 흉부에서 7.75mGy, 복부 및 요추부, 골반부에서는 기준 미만이었다. 생식선의 경우 골반검사에서 21.98mGy로 최대였으며 간접 피폭되는 검사에서 기준 준위 미만에서 6.92mGy까지 피폭되었다. CT 검사에서 DRL에 대한 저감화 방법은 국제기구에서 권고하고 있는 방사선 방어 원칙에 대한 정당한 해석과 제도적 뒷받침이 필요하다. 따라서 환자의 피폭을 최소화하기 위해서는 정당성을 충족하여야 하며 환자의 피폭선량에 미치는 영향들을 체계화하고 조직의 불필요한 피폭을 최소화 하여야 한다.