• Title/Summary/Keyword: 수원대학교

Search Result 796, Processing Time 0.04 seconds

The Effect of Hydraulic Retention Time on The Power Density in a Horizontal Flow Microbial Fuel Cell (수평 흐름형 미생물 연료전지에서 수리학적 체류시간이 전력수율에 미치는 영향)

  • Lee, Chae-Young;Park, Su-Hee;Woo, Jeong-Hei;Yoo, Kyu-Seon;Jeong, Jea-Woo;Song, Youn-Chae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.1
    • /
    • pp.109-114
    • /
    • 2011
  • This study was conducted to investigate the effect of hydraulic retention time(HRT) on the power density in a horizontal flow microbial fuel cell(MFC) reactor. When HRTs were 15min, 30min, 60min and 180min, maximum power densities were $24.7mW/m^2$, $27.3mW/m^2$, $22.8mW/m^2$ and $17.2mW/m^2$, respectively. The highest power density was obtained at HRT of 30min. It was 59% improvement when compared to the power density at an HRT of 180min. When HRT was increased, COD removal rate increased whereas the coulombic efficiency remained constant. The result shows that the optimal performance of the horizontal flow MFC reactor could be achieved at HRT of 30min.

Analysis of Water Distribution Network using Digital Data in Agricultural Watershed (농업용수 디지털 정보를 활용한 용수공급 네트워크 분석)

  • Shin, Ji-Hyeon;Nam, Won-Ho;Yoon, Dong-Hyun;Yang, Mi-Hye;Jung, In-Kyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.510-511
    • /
    • 2022
  • 물관리기본법의 시행 및 제1차 국가물관리기본계획의 이행에 따라 물관리 자료의 정보화 요구가 증가하고 있다. 과거 농업용수관리는 기초자료의 오류, 계측데이터의 부족 등이 한계점으로 지적되었으며, 과학화·표준화된 농업용수 물수급 분석 체계 구축 및 물정보의 정확성이 요구된다. 최근 통합물관리 국가정책 대응을 위한 물수급 분석 기반 마련을 목적으로 한국농어촌공사에서는 농업용수 용 배수 계통 정밀조사, 공간자료 재구축 등을 통한 농업용수 디지털 정보체계 구축 사업이 진행되고 있다. 연속수치지형도 및 토지피복, 스마트팜맵 등의 디지털 공간자료를 수집하고 현장조사와 영농조사를 바탕으로 최신화된 용배수계통도, 수혜면적 자료를 구축하였다. 본 연구에서는 디지털화한 용배수계통도를 이용하여 수리해석 모델 기초자료를 구축하고, 들녘단위 (주·보조수원, 저수지 및 양수장 등) 용수계통도 구현함으로써 수원공별 용수공급 네트워크를 분석하고자 한다. 농업용수 공급체계 반영이 가능한 EPA-SWMM (United States Environmental Protection Agency Storm Water Management Model)을 활용하여 다양한 물공급 시나리오를 적용하여 최적의 물관리 방안을 제시하고자 한다. 본 연구에서는 경기도 안성시 고삼저수지를 대상으로 연속수치지형도, 농경지전자지도, 고해상도 DEM 등을 활용한 디지털 조사와 수로 표고, 길이 및 너비 등 현장조사를 수행하였으며, 현장 물관리 방안을 적용하여 물분배 모의가 가능한 EPA-SWMM 기반 수원공-용수로-수혜구역을 연결하는 용수공급 네트워크를 구축하였다. 농촌용수종합정보시스템 (Rural Agricultural Water Resource Information System, RAWRIS)에서 제공하는 계측 자료를 활용하여 관개기간의 강수량, 소비수량, 증발산량, 공급량 등을 적용하여 농업용수 공급량, 배분량을 추정하였다. 본 연구의 결과는 물관리 담당자에게 상세한 현행 용수공급량 및 용수공급체계 정보 제공과 향후 국가물관리기본계획, 농어촌용수이용합리화계획의 물수급 분석 기초자료로 활용 가능할 것으로 사료된다.

  • PDF

A Study on Operational Index Calculation for Water Management of the Region (지역의 물관리를 위한 운영지수 산정에 관한 연구)

  • Gwon, Yong Hyeon;Jung, Sung Eun;Jung, Ji Won;Yum, Kyung Taek
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.641-641
    • /
    • 2015
  • 수자원 관리의 새로운 패러다임으로 스마트워터그리드가 이슈화되고 있다. 스마트워터그리드는 현재 직면해 있는 물 문제를 ICT기술을 활용하여 효율적으로 관리 및 운영할 수 있는 기술이다. 가뭄과 홍수 등을 대응하기 위한 분산형 수자원, 그리고 수량과 수질등의 통합 관리를 지향하는 물관리 패러다임과 ICT와 물산업을 융복합화하여 양방향 실시간 운영을 통한 네트워크 구성, 그리고 대규모 수원개발과 장거리 수송방식으로부터 지역단위의 부존된 수자원인 다중수원을 효율적으로 활용하고, 이들 수원의 최적 블랜딩 기술 및 멀티워터루프를 이용한 수요자 중심의 물관리에 초점을 맞추고 있다. 이에 본 연구에서는 지역의 부존된 수자원을 효율적으로 관리하기 위한 운영지수를 산정함으로써 지역의 평상시 물관리 운영과 상수공급차단, 다중수원에 오염물질 유입, 가뭄발생 등 비상시 상황에 물관리가 원활히 이루어지도록 하였다. 스마트워터그리드에서 사용되는 물관리 운영지수는 비상시 지역간 플랫폼에 정상적으로 물공급이 어렵거나, 예상되어 유량 확보가 필요시 원활하게 유량 확보가 가능하도록 주변 지역간의 운영지수를 산정하여 최적의 조건을 도출하여 우선순위를 시나리오에 나타내어 사용자가 플랫폼에 물공급이 가능하도록 제시한 운영지수이다. 물관리 운영지수는 중회귀분석 기법을 이용하여 종속변수에 선형적인 영향을 미치는 유량, 수질, 이송거리, 전력비용, 경제적인 영향 등을 고려하여 종속변수의 값을 예측하고 통계적인 기법으로 유량, 수질, 이송거리, 전력비용, 경제적인 영향 등에 대한 장래추정치를 부여하여 회귀모델을 구축하여 물관리 운영지수를 산정하였다. 이를 활용하여 평상시에는 물수요 공급량을 정확히 관리하여 지역간의 수자원 불균형을 해소하고 비상시에는 상황을 대처하여 지역의 물부족 문제를 해소할 수 있을 것으로 판단된다.

  • PDF

Performance Evaluation of ABR and ASBR for Anaerobic Methane Fermentation (ABR과 ASBR 형태에 따른 혐기성 메탄 발효 운전 성능 평가)

  • Lee, Chae-Young;Lee, Se-Wook
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.2
    • /
    • pp.49-54
    • /
    • 2011
  • This study was conducted to evaluate the performance of methane fermentation from effluent of hydrogen fermentation reactor in anaerobic baffled reactor (ABR) and anaerobic sequencing batch reactor (ASBR). Two reactors were operated at organic loading rate of $1.0kg\;COD/m^3{\cdot}d$ and hydraulic retention time (HRT) of 20 day. Methane production rates of ABR and ASBR for start-up periods were 0.04 L/L/d and 0.19 L/L/d, respectively, whereas maximum methane production rates of ABR and ASBR were 0.25 L/L/d and 0.31 L/L/d, respectively. Removal rates of chemical oxygen demand (COD) in ABR and ASBR for start-up periods were 89% and 92%, respectively. After startup periods, removal rates of COD and volatile solids (VS) in ABR and ASBR were maintained over 90%. The specific methanogenic activity (SMA) increased as microorganism acclimated to the substrate.

Effect of operational pH on anaerobic hydrogen fermentation of food waste (음식폐기물의 혐기성 수소 발효시 운전 pH의 영향)

  • Lee, Chae-Young;Lee, Se-Wook
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.3
    • /
    • pp.73-78
    • /
    • 2011
  • The pH is one of the most important factors affecting metabolism pathway and activity of hydrogen producing bacteria. The effect of operational pH on anaerobic hydrogen fermentation of food waste was evaluated at mesophilic condition. In this batch experiment, the initial pH was 8.0 and the operational pH was controlled at 4.7~7.0 by the addition of 5N KOH solutions. At the operational pH of 4.7, the lag phase and the maximum hydrogen production were 47.9h and 534.4 mL, respectively. The lag phase and the maximum hydrogen production were decreased as the operational pH increased. At the operational pH of 7.0, the lag phase and the maximum hydrogen production were 4.2 h and 213.8 mL, respectively.

A Study on the Synthesis of CH4 from CO2 of Biogas Using 40 wt% Ni-Mg Catalyst: Characteristic Comparison of Commercial Catalyst and 40 wt% Ni Catalyt (40 wt% Ni 촉매에서 바이오가스 중 CO2로부터 메탄제조에 관한 연구: Commercial Catalyst와의 특성 비교분석)

  • HAN, DANBEE;BAEK, YOUNGSOON
    • Journal of Hydrogen and New Energy
    • /
    • v.32 no.5
    • /
    • pp.388-400
    • /
    • 2021
  • Power to gas (P2G) is one of the energy storage technologies that can increase the storage period and storage capacity compared to the existing battery type. One of P2G technology produces hydrogen by decomposing water from renewable energy (electricity) and the other produces CH4 by reacting hydrogen with CO2. This study is an experimental study to produce CH4 by reacting CO2 of biogas with hydrogen using a 40 wt% Ni-Mg-Al catalyst and a commercial catalyst. Catalyst characteristics were analyzed through H2-TPR, XRD, and XPS instruments of 40% Ni catalyst and commercial catalyst. The effect on the CO2 conversion rate and CH4 selectivity was analyzed, and the activities of a 40% Ni catalyst and a commercial catalyst were compared. As a result of experiment, In the case of a 40 wt% catalyst, the maximum CO2 conversion rate showed 77% at the reaction temperature of 400℃. Meanwhile, the commercial catalyst showed a maximum CO2 conversion rate of 60% at 450℃. When 50% of CO was added to the CO2 methanation reaction, the CO2 conversion rate was increased by about 5%. This is considered to be due to the atmosphere in which the CO reaction can occur without the process of converting to CH4 after forming carbon and CO as intermediates in terms of the CO2 mechanism on the catalyst surface.

Surface Modification of Nano Silica Prepared by Sol-gel Process and Subsequent Application towards Gas-barrier Films (졸-겔 공정으로 제조한 나노 실리카의 표면개질 및 가스차단성 필름으로의 응용)

  • Jang, Hyo Jun;Chang, Mi Jung;Nam, Kwang Hyun;Chung, Dae-won
    • Applied Chemistry for Engineering
    • /
    • v.30 no.1
    • /
    • pp.68-73
    • /
    • 2019
  • We prepared hydrophobic silica particles by a sol-gel process from tetraethyl orthosilicate (TEOS), followed by coupling the reaction with octyltrimethoxysilane (OTMS) or hexadecyltrimethoxysilane (HDTMS) under various reaction conditions. We confirmed the extent of silica surface modification with organic compounds by SEM-EDS, thermogravimetry and elemental analysis. The silica particles obtained after the hydrolysis reaction of TEOS in ethanol at $50^{\circ}C$ for 24 h and the coupling reaction with OTMS for 2 h at the same temperature displayed the optimum performance in terms of the dispersity in an organic solvent and the surface roughness of films composited with epoxy resins. The oxygen permeability of the composite film with modified-silica was 12% lower than that of using the film without modified-silica.

A Study on the Estimation of GHGs Emission by Military Sector (군사부문 온실가스 배출량 산정에 관한 연구)

  • Song, Ki Pong;Choi, Sang Jin;Kim, Jeong;Jang, Young Kee
    • Journal of Climate Change Research
    • /
    • v.8 no.2
    • /
    • pp.177-186
    • /
    • 2017
  • In this research, we have developed standardized procedures for preparing of emission inventories on military sector. The procedures are as follows; 1) Identify all relevant emission sources list of military sector in Republic of Korea. 2) Select methods to estimate GHGs emissions by source categories such as heating boilers, tactical vehicles, military vessels and military aviation from US EPA, IPCC, EEA/EMEP, and ROK Ministry of Environment. 3) Identify and select data sources for activities and parameters from Korea annual oil statistics and Korea Procurement system. 4) Compare with each GHGs emission used by each activities. The conclusive results utilized by emission source categories and associated factors are described as follows; In 2013, GHGs was estimated 2,656 kilotons $CO_2-eq$ emitted by military sector. The diesel combustion contributed from a minimum of 43.8% to a maximum of 50.2% and JP-8 contributed from a minimum of 43.7% to a maximum of 52.8% to the 2001~2015 GHGs emission trend. In the result of comparing GHGs emissions with Korea Annual Oil Statistics (Tier 1) and supplied fuel through the Korea Procurement System (Tier 2) in 2015, the total GHGs emission was 2,867 kilotons $CO_2-eq$ estimated by Tier 2 is similar to the emission estimated by Tier 1. However, this reveals that the GHGs emission separated by local areas were a lot of different from Tier 1 and 2. The cause of difference between Tier 1 and Tier 2 was that Korea annual oil statistics utilized data from a fuel supplier. The data does not reflect the reality of the location of end user.

A Study on the CO2 Methanation in Power to Gas (P2G) over Ni-Catalysts (Ni 촉매 상에서 Power to Gas (P2G) 기술의 CO2 메탄화 반응에 관한 연구)

  • YEOM, GYUIN;SEO, MYUNGWON;BAEK, YOUNGSOON
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.1
    • /
    • pp.14-20
    • /
    • 2019
  • The power to gas (P2G) is one of the energy storage technologies that can increase the storage period and storage capacity compared to the existing battery type. One of P2G technologies produces hydrogen by decomposing water from renewable energy (electricity) and the other produces $CH_4$ by reacting hydrogen with $CO_2$. The objective of this study is the reaction of $CO_2$ methanation which synthesized methane by reacting carbon dioxide and hydrogen. The effect of $CO_2$ conversion and $CH_4$ selectivity on reaction temperature, pressure, and methane contents over 40% Ni catalyst was mainly investigated throughout this study. As a result, the activity of this catalyst appeared to be the highest in $CH_4$ yield at around $400^{\circ}C$ and the selectivity of $CH_4$ increased with increasing reaction pressure. The methane content was not significantly influenced below 3% of all componets. As the space velocity increases from 10,000 to 30,000/hr, the $CO_2$ conversion rate tends to decrease.

A comparative study on dynamic behavior of high-rise building and low-rise building considering SSI analysis (SSI 해석을 고려한 초고층 및 저층 건물 동적거동 비교 연구)

  • You, Kwang-Ho;Kim, Seung-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.973-987
    • /
    • 2018
  • Most of the previous seismic analyses have been carried out by separating the ground and structures, and there is a lack of comparative study on the dynamic behavior of high-rise and low-rise buildings. Therefore, in this study, the sensitivity analysis was performed with selected parameters by using a finite element analysis program in order to grasp the dynamic behavior of high-rise and low-rise buildings. As a result, it was turned out that the horizontal displacement, the interstory drift ratio, and the bending stress of a high-rise building were more affected by a long seismic wave than a low-rise buildings. Also, the weak parts of a high-rise and low-rise building were more affected by type of seismic wave than the ground conditions. Therefore, it is inferred that it will be helpful for seismic designs to consider the influence of ground conditions and seismic wave type on buildings.