• Title/Summary/Keyword: 수술 전 계획

Search Result 180, Processing Time 0.032 seconds

Comparisons between the Two Dose Profiles Extracted from Leksell GammaPlan and Calculated by Variable Ellipsoid Modeling Technique (렉셀 감마플랜(LGP)에서 추출된 선량 분포와 가변 타원체 모형화기술(VEMT)에 의해 계산된 선량 분포 사이의 비교)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • A high degree of precision and accuracy in Gamma Knife Radiosurgery(GKRS) is a fundamental requirement for therapeutical success. Elaborate radiation delivery and dose gradients with the steep fall-off of radiation are clinically applied thus necessitating a dedicated Quality Assurance(QA) program in order to guarantee dosimetric and geometric accuracy and reduce all the risk factors that can occur in GKRS. In this study, as a part of QA we verified the accuracy of single-shot dose profiles used in the algorithm of Gamma Knife Perfexion(PFX) treatment planning system employing Variable Ellipsoid Modeling Technique(VEMT). We evaluated the dose distributions of single-shots in a spherical ABC phantom with diameter 160 mm on Gamma Knife PFX. The single-shots were directed to the center of ABC phantom. Collimating configurations of 4, 8, and 16 mm sizes along x, y, and z axes were studied. Gamma Knife PFX treatment planning system being used in GKRS is called Leksell GammaPlan(LGP) ver 10.1.1. From the verification like this, the accuracy of GKRS will be doubled. Then the clinical application must be finally performed based on precision and accuracy of GKRS. Specifically the width at the 50% isodose level, that is, Full-Width-of-Half-Maximum(FWHM) was verified under such conditions that a patient's head is simulated as a sphere with diameter 160mm. All the data about dose profiles along x, y, and z axes predicted through VEMT were excellently consistent with dose profiles from LGP within specifications(${\leq}1mm$ at 50% isodose level) except for a little difference of FWHM and PENUMBRA(isodose level: 20%~80%) along z axis for 4 mm and 8mm collimating configurations. The maximum discrepancy of FWHM was less than 2.3% at all collimating configurations. The maximum discrepancy of PENUMBRA was given for the 8 mm collimator along z axis. The difference of FWHM and PENUMBRA in the dose distributions obtained with VEMT and LGP is too small to give the clinical significance in GKRS. The results of this study are considered as a reference for medical physicists involved in GKRS in the whole world. Therefore we can work to confirm the validity of dose distributions for all collimating configurations determined through the regular preventative maintenance program using the independent verification method VEMT for the results of LGP and clinically assure the perfect treatment for patients of GKRS. Thus the use of VEMT is expected that it will be a part of QA that can verify and operate the system safely.

Clinical Factors Predicting the Pathologic Tumor Response after Preoperative Concurrent Chemoradiotherapy for Rectal Cancer (직장암에 수술 전 항암화학방사선 동시 병용요법 후 종양의 병리학적 반응에 영향을 주는 임상적 예측 인자)

  • Lee, Ji-Hae;Lee, Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.213-221
    • /
    • 2008
  • Purpose: The objective of this retrospective study was to identify predictive factors for the complete pathologic response and tumor downstaging after preoperative concurrent chemoradiotherapy for locally advanced rectal cancer. Materials and Methods: Between the years 2000 and 2008, 39 patients with newly diagnosed rectal cancer without prior evidence of distant metastasis received preoperative concurrent chemoradiotherapy followed by surgery. The median radiation dose was 50.4 Gy (range, $45{\sim}59.4\;Gy$)). Thirty-eight patients received concurrent infusional 5-fluorouracil and leucovorin, while one patient received oral capecitabine twice daily during radiotherapy. Results: A complete pathologic response (CR) was demonstrated in 12 of 39 patients (31%), while T-downstaging was observed in 24 of 39 patients (63%). N-downstaging was observed in 18 of 28 patients (64%), with a positive node in the CT scan or ultrasound. Two patients with clinical negative nodes were observed in surgical specimens. The results from a univariate analysis indicated that the tumor circumferential extent was less than 50% (p=0.031). Moreover, the length of the tumor was less than 5 cm (p=0.004), while the post-treatment carcinoembryonic antigen (CEA) levels were less than or equal to 3.0 ng/mL (p=0.015) and were significantly associated with high pathologic CR rates. The univariate analysis also indicated that the adenocarcinoma (p=0.045) and radiation dose greater than or equal to 50 Gy (p=0.021) were significantly associated with high T-downstaging, while a radiotherapy duration of less than or equal to 42 days (p=0.018) was significantly associated with N-downstaging. The results from the multivariate analysis indicated that the lesser circumferential extent of the tumor (hazard ratio [HR] 0.150; p=0.028) and shorter tumor length (HR, 0.084; p=0.005) independently predicted a higher pathologic CR. The multivariate analysis also indicated that a higher radiation dose was significantly associated with higher T-downstaging (HR, 0.115; p=0.025), while the shorter duration of radiotherapy was significantly associated with higher N-downstaging (HR, 0.028; p=0.010). Conclusion: The circumferential extent of the tumor and its length was a predictor for the pathologic CR, while radiation dose and duration of radiotherapy were predictors for tumor downstaging. Hence, these factors may be used to predict outcomes for patients and to develop further treatment guidelines for high-risk patients.

Development of System for Increasing Confidence on the Measurement of Discharge (PDA 활용 유량측정 신뢰도 향상 시스템 개발)

  • Jung Seung Kwon;Kim Nam Il;Kim Jae Bog;Park Jae Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.209-214
    • /
    • 2005
  • 수위, 우량, 유량, 유사량 등 수문자료중에서 유량자료는 가장 많은 쓰임새를 갖고 있음에도 불구하고 신뢰도가 낮은 이유로 인해 많은 문제점을 안고 있는 것이 현실이다. 이렇게 유량측정자료의 신뢰도가 낮은 이유는 크게 5가지로 들 수 있는데 1)측정 수행자의 잦은 교체 등에 따른 조사역량 부족, 2)수행자별 유량측정 및 분석방법 상이, 3)장비의 유속검정 등 관리미흡 및 성능 저하, 4)유량측정 상당시간 경과후 유량측정성과 정리로 오류 수정 곤란, 5)유량측정성과의 체계적인 관리 미흡 등이다. 이러한 문제점을 개선하고 현장에서의 유량측정 신뢰도를 향상시키기 위하여 (주)웹솔루스에서는 한국수자원공사의 용역을 통해 현장의 유량 측정 결과를 PDA를 이용하여 기록하고 이를 실시간으로 중앙의 서버로 전송하여 과거 자료의 분석을 통해 측정자료의 신뢰도를 검증함으로써 신뢰성 있는 유량측정자료를 측정하도록 지원하는 유량측정 신뢰도 향상 시스템을 개발하였고, 한국수자원공사와 공동으로 두개의 특허출원을 하였다(특허출원: 10-2002-0049188, 10-2005-11550). 현재 이 시스템은 2002년 8월 착수를 시작으로 9개월이 지난 2003년 3월에 시험판의 개발을 완료하고, 용담댐 유역의 주천교 등 5개 지점에 시험 적용하면서 많은 개선과 보완을 거쳐 2005년 현재에는 한국수자원공사에서 운영하고 있는 13개의 댐과 1개의 국가하천에 대하여 총 59개의 관측지점에서 활용되고 있으며, 현재(2005. 2월 기준)까지 1,660여건 이상의 전자야장이 데이터베이스에 구축되었으며, 유량측정성과 DB는 웹시스템(http://river.kowaco.or.kr)을 통해 운영되고 있다. 본 시스템 도입을 통해 유량측정성과가 체계적으로 관리되고 있으며, 향후 시스템에 대한 지속적인 유지관리가 이루어진다면 오랜기간에 걸쳐 축적된 많은 양의 유량자료는 수자원관리에 큰 역할을 수행할 수 있을것으로 판단된다. 개발계획 및 유역의 특성 등을 조사하고, 시험유역의 선정기준을 수립하여 연구의 목적과 부합되는 지구를 시험유역으로 선정하였으며 선정된 시험유역에 대하여 수문$\cdot$수질 조사 계획을 수립하고, 계측시설을 설치하여 시험운영을 실시하고, 향후 시험유역의 수문계측 및 관리방안을 수립하고자 한다.1종이었다. 이 중 한국 고유종은 11종이었고, 외래 어종은 검정우럭과 2종이 조사되었으며, Zacco platypus(피라미), Zacco temmincki(갈겨니), Acheilongnathus koreanus(칼납자루), Odontobutis platycephala(동사리), Coreoleuciscus splendidus(쉬리) 순으로 분포하고 있었고, Acheilognathus signifer(묵납자루)는 댐 건설 전에는 많이 분포하였으나 현장조사에서 서식을 확인 할 수 언어 개체수의 큰 감소내지 멸종된 것으로 추정되었다.에서 동시에 시행하였다. 수술 후 1년 내 시행한 심초음파에서 모든 환아에서 단지 경등도 이하의 승모판 폐쇄 부전 소견을 보였다. 수술 후 조기 사망은 없었으며, 합병증으로는 유미흉이 한 명에서 있었다. 술 후 10개월째 허혈성 확장성 심근증이 호전되지 않아 Dor 술식을 시행한 후 사망한 예를 제외한 나머지 6명은 특이 증상 없이 정상 생활 중이다 결론: 좌관상동맥 페동맥이상 기시증은 드물기는 하나, 영유아기에 심근경색 및 허혈성 심근증 또는 선천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고 있다.교하여 유의한 차이가 관찰되지 않았다. 또한 HSP 환자군에서도 $IL1RN^{*}2$ allele 빈도와 carria

  • PDF

Classification of Deep Inferior Epigastric Perforator Courses Based on Computed Tomography Angiography: Incidences and Clinical Implications (컴퓨터 단층 촬영 혈관 조영술을 이용한 심하복벽 혈관과 천공지의 박리 용이성에 따른 분류)

  • Lee, Yeonhoon;Kim, Sung Chan;Eom, Jin Sup;Kim, Eun Key
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.281-289
    • /
    • 2018
  • Purpose: Preoperative surgical planning utilizing computed tomography angiography (CTA) has now become a routine in many practices. We analyzed the course of the deep inferior epigastric artery (DIEA) and its perforators (DIEP) that would either facilitate or hinder flap dissection based on CTA to aid surgical planning. Methods: The 115 consecutive patients who underwent abdominally based free flap breast reconstruction were enrolled in this prospective study. DIEA/P courses were categorized mainly according to their intramuscular courses and their incidences were investigated. Results: A total of 425 perforators were identified preoperatively on the CTA, with an average number of 3.7 distinctly visualized in the entire flap territory. Eighty-nine perforators (20.9%) had a favorable (less than 1 cm intramuscular course) pattern, namely long submuscular (34.8% of the patients), long subfascial (15.6%), and total circummuscular (13.9%). Overall 56.5% of the patients had at least one favorable DIEA/P. On the other hand, absence of DIEA and absence of adequate (>1 mm) DIEP was reported in 3 and 8 hemiabdomen. Conclusion: Preoperative CTA evaluation of DIEA/P can be used to identify favorable as well as unfavorable courses for dissection to aid surgical planning.

A study on the limit of orthodontic treatment (교정 치료의 한계에 관한 연구)

  • Kim, Sun-Ju;Park, So-Young;Woo, Hae-Hong;Park, Eun-Jie;Kim, Young-Ho;Lee, Shin-Jae;Moon, Seong-Cheol;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.34 no.2 s.103
    • /
    • pp.165-175
    • /
    • 2004
  • Information on the limits of treatment could allow for more rational treatment Planning and better results after treatment. From this point of view, this article has attempted to discuss the limits of orthodontic tooth movement. A relatively wider range of tooth movement is expected after Class III surgical-orthodontics than after conventional orthodontic treatment in general. The purposes of this Paper were: first, to evaluate the reliability of teeth position measuring gauge; and second, to elucidate the limits of orthodontic tooth movement. Dental casts of fifty-fine subjects were analyzed by using Set-up model checker (InVisitec Co., Korea) before and aster the Class III surgical-orthodontic treatment. The changes of maxillary and mandibular dental arch widths were also measured from the canines to the second molars. To test the inter-examiner reliability, randomly selected casts were measured by another examiner. Descriptive statistics and paired t tests were used to explain the tooth movement during treatment. The results showed a relatively good reliability of measuring instruments and a very diverse range of tooth movement. Collective changes by the orthodontic tooth movement evaluated in Class III surgical-orthodontics allowed for a suggestive interpretation of specific treatment patterns. Arch width changes during the inter-arch coordination were mainly the result of tipping in both buccal segments. Based on the results of this study, the possibility of a change in dentition as a result of orthodontic treatment should be understood in order to launch a well-organized plan of treatment.

Full mouth rehabilitation with implant-supported fixed prosthesis via dental CAD-CAM system (Dental CAD-CAM system을 통한 고정성 전악 임플란트 수복 증례)

  • Hong, Jeong-Min;Han, Jung-Suk;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.97-106
    • /
    • 2021
  • Dental implants should be placed at ideal sites for implant-supported restorations. For a patient with insufficient residual ridge, mouth preparation including surgical intervention can be indicated to establish a soft and hard tissue environment favorable for a definitive prosthesis. Prosthodontic design based on computer-guided surgery and computer-aided design-computer-aided manufacturing (CAD-CAM) provides a visual blueprint allowing a clinician to assess the necessity of such a surgical intervention beforehand. In this case, a definitive restoration was planned and made via a CAD-CAM system according to the patient's oral status before treatment, simulated surgical interventions and serial provisional restorations. Based on the planning, a guided template was made and the implants were installed with bone augmentation using the template. Customized abutments, the first and the second provisional restorations were designed and fabricated by CAD-CAM. The definitive restorations were digitally made following the shape of the second provisional prostheses, which were confirmed in the patient's mouth. The patient was satisfied with the masticatory, phonetic and aesthetic functions of these definitive prostheses.

용담댐 건설로 인한 금강 상류의 하천환경변화 분석 II - 수리변화분석 -

  • 정승권;정동양
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.971-976
    • /
    • 2004
  • 하천유지를 위한 하천내 최소유량의 충족은 사실상 환경문제에 제공되는 것으로서 기본적으로 하천변 수생식물의 생태계 서식처를 유지하거나 복원하기 위해 제공된다. 또한 하천유지유량은 하천의 고유종 동${\cdot}$식물을 보전하고, 아름다운 하천에 대한 심미적 질을 유지하며 여가활동 및 상업적 어획고를 최대로 늘릴 수 있거나 과학적 또는 문화적 관심사의 특성을 보호하는 기능을 위한 목적으로도 제공된다. 그러므로 생태학적인 하천유지유량 차원에서 무엇보다 중요한 것은 충분한 물을 확보하고 쾌적한 하천을 유지할 수 있는 맑은 물을 하천에 흐르도록 하는 것이다. 이와 더불어 하천의 생태학적인 측면에서는 서식지 보호를 고려한 계획이 뒷받침되어야 할 것이다. 기존의 개발은 하천정비, 골재채취, 수중 보와 하구 둑 등 하천시설물 건설, 그리고 댐 및 교량건설 등 인위적인 요인에 의하여 하천환경이 심각하게 변화는 경우가 많다. 특히 댐 건설로 인해 하류지역에 수리학적 변화와 하상 변동 등이 발생하고, 이로 인하여 생태계의 변화를 초래하기도 한다. 따라서 본 연구에서는 금강 최상류에 건설된 용담다목적댐에 의해 인위적으로 하천유입량이 감소하고 이로 인해 발생할 수 있는 수리학적 변화를 모의하여 댐 건설이 금강 상류에 미치는 영향을 분석하고자 한다. 이를 위해 2차원 유한요소모형을 이용하였으며, 댐 건설전 자연유출량 및 댐 건설후 하천유지유량에 의한 하천의 건조면적, 습지면적을 산정하였다. 또한 하천의 한계소류력과 하도를 형성하는 재료에 따라 바닥면 전단응력을 산정하여 그 차(差)를 활용하여 유량에 따른 유사이송현황을 모의하였다. 모의된 결과를 visual하게 표현하고자 GIS 기법을 이용하여 주요구간에 대한 유사이송현황을 도시하였다.유역의 고도차를 이용한 흐름특성 분석을 위해 수치고도자료를 이용하여 유역흐름특성을 분석할 수 있는 TOPAZ(Topographic PArameteri-Zation) 프로그램을 이용하였다. TOPAZ 프로그램을 통해 분석된 각 격자별 분포형 수문 매개변수는 적합한 관계식을 통해 분포형 유출량을 모의하는데 적용된다.다 정확한 유입량 예측이 가능할 것으로 사료된다.이 작은 오차를 발생하였으며, 전체적으로 퍼프 모형이 입자모형보다는 훨씬 적은 수의 계산을 통해서도 작은 오차를 나타낼 수 있다는 것을 알 수 있었다. 그러나 Gaussian 분포를 갖는 퍼프모형은 전단흐름에서의 긴 유선형 농도분포를 모의할 수 없었고, 이에 관한 오차는 전단계수가 증가함에 따라 비선형적으로 증가하였다. 향후, 보다 다양한 흐름영역에서 장${\cdot}$단점 분석 및 오차해석을 수행한 후에 각각의 Lagrangian 모형의 장점만을 갖는 모형결합 방법을 제시할 수 있을 것으로 판단된다.mm/$m^{2}$로 감소한 소견을 보였다. 승모판 성형술은 전 승모판엽 탈출증이 있는 두 환아에서 동시에 시행하였다. 수술 후 1년 내 시행한 심초음파에서 모든 환아에서 단지 경등도 이하의 승모판 폐쇄 부전 소견을 보였다. 수술 후 조기 사망은 없었으며, 합병증으로는 유미흉이 한 명에서 있었다. 술 후 10개월째 허혈성 확장성 심근증이 호전되지 않아 Dor 술식을 시행한 후 사망한 예를 제외한 나머지 6명은 특이 증상 없이 정상 생활 중이다 결론: 좌관상동맥 페동맥이상 기시증은 드물기는 하나, 영유아기에 심근경색 및 허혈성 심근증 또는 선천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술

  • PDF

Endophthalmitis after Removal of an Intralenticular Foreign Body in Place without Symptoms for 20 Years (20년 동안 증상없이 잔존한 수정체 내 이물제거 후 발생한 안내염)

  • Choi, Young;Eom, Youngsub;Choi, Soo Youn;Lee, Bo Young;Kim, Eun Jee;Kang, Su-Yeon;Song, Jong Suk;Kim, Hyo Myung
    • Journal of The Korean Ophthalmological Society
    • /
    • v.60 no.5
    • /
    • pp.480-485
    • /
    • 2019
  • Purpose: We report a case of postoperative endophthalmitis in the cataract patient, associated with removal of an intralenticular foreign body that had remained in place without symptoms for 20 years. Case summary: A 45-year-old male visited our outpatient clinic complaining of gradual visual loss in his right eye over the past 3 months. In slit-lamp examinations, anterior capsular opacification, nuclear sclerosis, and posterior subcapsular opacity were observed in the right eye. Twenty years before, a tiny metallic projectile had hit his right eye, but slit-lamp examination at the time of injury did not reveal any intraocular foreign body. We decided to undergo cataract surgery. During phacoemulsification, a metallic foreign body was found in the lens and safely removed; then an intraocular lens was implanted. As hypopyon was evident 3 days later, we injected intravitreal antibiotics and applied fortified antibiotic eye drops to the right eye. The anterior chamber inflammation improved and the best-corrected visual acuity recovered to 1.0. Conclusions: Surgeon should be aware of that endophthalmitis could develop after cataract surgery with removal of an intralenticular foreign body that had been in place for 20 years. But did not trigger inflammation or cause any symptoms as the cataract progressed.

The 1998, 1999 Patterns of Care Study for Breast Irradiation after Mastectomy in Korea (1998, 1999년도 우리나라에서 시행된 근치적 유방 전절제술 후 방사선치료 현황 조사)

  • Keum,, Ki-Chang;Shim, Su-Jung;Lee, Ik-Jae;Park, Won;Lee, Sang-Wook;Shin, Hyun-Soo;Chung, Eun-Ji;Chie, Eui-Kyu;Kim, Il-Han;Oh, Do-Hoon;Ha, Sung-Whan;Lee, Hyung-Sik;Ahn, Sung-Ja
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.7-15
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: To determine the patterns of evaluation and treatment in patients with breast cancer after mastectomy and treated with radiotherapy. A nationwide study was performed with the goal of improving radiotherapy treatment. $\underline{Materials\;and\;Methods}$: A web- based database system for the Korean Patterns of Care Study (PCS) for 6 common cancers was developed. Randomly selected records of 286 eligible patients treated between 1998 and 1999 from 17 hospitals were reviewed. $\underline{Results}$: The ages of the study patients ranged from 20 to 80 years (median age 44 years). The pathologic T stage by the AJCC was T1 in 9.7% of the cases, T2 in 59.2% of the cases, T3 in 25.6% of the cases, and T4 in 5.3% of the cases. For analysis of nodal involvement, N0 was 7.3%, N1 was 14%, N2 was 38.8%, and N3 was 38.5% of the cases. The AJCC stage was stage I in 0.7% of the cases, stage IIa in 3.8% of the cases, stage IIb in 9.8% of the cases, stage IIIa in 43% of the cases, stage IIIb in 2.8% of the cases, and IIIc in 38.5% of the cases. There were various sequences of chemotherapy and radiotherapy after mastectomy. Mastectomy and chemotherapy followed by radiotherapy was the most commonly performed sequence in 47% of the cases. Mastectomy, chemotherapy, and radiotherapy followed by additional chemotherapy was performed in 35% of the cases, and neoadjuvant chemoradiotherapy was performed in 12.5% of the cases. The radiotherapy volume was chest wall only in 5.6% of the cases. The volume was chest wall and supraclavicular fossa (SCL) in 20.3% of the cases; chest wall, SCL and internal mammary lymph node (IMN) in 27.6% of the cases; chest wall, SCL and posterior axillary lymph node in 25.9% of the cases; chest wall, SCL, IMN, and posterior axillary lymph node in 19.9% of the cases. Two patients received IMN only. The method of chest wall irradiation was tangential field in 57.3% of the cases and electron beam in 42% of the cases. A bolus for the chest wall was used in 54.8% of the tangential field cases and 52.5% of the electron beam cases. The radiation dose to the chest wall was $45{\sim}59.4\;Gy$ (median 50.4 Gy), to the SCL was $45{\sim}59.4\;Gy$ (median 50.4 Gy), and to the PAB was $4.8{\sim}38.8\;Gy$, (median 9 Gy) $\underline{Conclusion}$: Different and various treatment methods were used for radiotherapy of the breast cancer patients after mastectomy in each hospital. Most of treatment methods varied in the irradiation of the chest wall. A separate analysis for the details of radiotherapy planning also needs to be followed and the outcome of treatment is needed in order to evaluate the different processes.

Estimation of Inhomogeneity Correction Factor in Small Field Dosimetry (소조사면에서의 불균질 물질 보정 계산의 평가)

  • Shin, Hun-Joo;Kang, Young-Nam;Jang, Ji-Sun;Seo, Jae-Hyuk;Jung, Ji-Young;Choi, Byung-Ock;Choi, Ihl-Bohng;Lee, Dong-Joon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.260-268
    • /
    • 2009
  • In this study, we estimated inhomogeneity correction factor in small field. And, we evaluated accuracy of treatment planning and measurement data which applied inhomogeneity correction factor or not. We developed the Inhomogeneity Correction Phantom (ICP) for insertion of inhomogeneity materials. The inhomogeneity materials were 12 types in each different electron density. This phantom is able to adapt the EBT film and 0.125 cc ion chamber for measurement of dose distribution and point dose. We evaluated comparison of planning and measurement data using ICP. When we applied to inhomogeneity correction factor or not, the average difference was 1.63% and 10.05% in each plan and film measurement data. And, the average difference of dose distribution was 10.09% in each measurement film. And the average difference of point dose was 0.43% and 2.09% in each plan and measurement data. In conclusion, if we did not apply the inhomogeneity correction factor in small field, it shows more great difference in measurement data. The planning system using this study shows good result for correction of inhomogeneity materials. In radiosurgery using small field, we should be correct the inhomogeneity correction factor, more exactly.

  • PDF