• Title/Summary/Keyword: 수소연료

Search Result 1,756, Processing Time 0.029 seconds

Economic Analysis and Comparison between Low-Power and High-Power SOEC Systems (저출력 및 고출력 SOEC 시스템의 경제성 분석 비교)

  • TUANANH BUI;YOUNG SANG KIM;DONG KEUN LEE;KOOK YOUNG AHN;YONGGYUN BAE;SANG MIN LEE
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.6
    • /
    • pp.707-714
    • /
    • 2022
  • Hydrogen production using solid oxide electrolysis cells (SOEC) is a promising technology because of its efficiency, cleanness, and scalability. Especially, high-power SOEC system has received a lot of attention from researchers. This study compared and analyzed the low-power and high-power SOEC system in term of economic. By using revenue requirement method, levelized cost of hydrogen (LCOH) was calculated for comparison. In addition, the sensitivity analysis was performed to determine the dependence of hydrogen cost on input variables. The results indicated that high-power SOEC system is superior to a low-power SOEC system. In the capital cost, the stack cost is dominant in both systems, but the electricity cost is the most contributed factor to the hydrogen cost. If the high-power SOEC system combines with a nuclear power plant, the hydrogen cost can reach 3.65 $/kg when the electricity cost is 3.28 ¢/kWh and the stack cost is assumed to be 574 $/kW.

Two-stage Biological Hydrogen Production form Organic Wastes and Waste-waters and Its Integrated System (유기성 폐기물 및 폐수로부터 2단계 생물학적 수소생산 및 통합화 시스템)

  • Kim, Mi-Sun;Yoon, Y.S.
    • Journal of Hydrogen and New Energy
    • /
    • v.13 no.1
    • /
    • pp.52-64
    • /
    • 2002
  • 유기성 폐기물을 이용하여 생물학적 수소생산 통합화 시스템 연구를 수행하였다. 통합화 시스템은 유기성폐기물의 전처리, 2단계 혐기발효 및 광합성 배양으로 구성된 생물학적 수소생산 공정, 초임계수 가스화 공정, 생산된 가스의 저장, 분리 및 연료전지를 이용한 전력 생산으로 구성되었다. 실험에 사용된 유기성 폐자원은 식품공장 폐수, 과일폐기물, 하수슬러지이며, 전처리는 폐기물에 따라 열처리 및 물리적 처리를 하였으며, 전처리된 시료는 생물학적 수소생산 공정에 직접 적용되었다. Clostridium butyricum 및 메탄 생성조에서 발생하는 하수슬러지중의 미생물 복합체는 수소생산 혐기 발효공정에 사용되었으며, 광합성 수소생산 미생물인 홍색 비유황 세균은 광합성 배양에 사용되었다. 생물학적 공정에서 발생하는 미생물 슬러지는 초임계수 가스화 공정으로 수소를 발생하였으며, 슬러지 중의 COD를 저하시켰다. 생물학적 공정 및 초임계수 가스화 공정에서 발생하는 수소는 가스탱크에 가입상태로 저장한 후, 95%순도로 분리하였으며, 정제된 수소는 연료전지에 연결하여 전력 생산을 하였다.

대체 에너지 이용 열원동기의 연구개발 동향

  • 이성열
    • Journal of the KSME
    • /
    • v.29 no.6
    • /
    • pp.618-626
    • /
    • 1989
  • 자동차용 메타놀 연료는 석유파동 이후의 석유 대체연료라는 관점에 저공해 연료의 관점이 추가 되어 최근 그 도입에 대한 연구가 활발해지고 있다. 메타놀 자동차에 관해서는 종래의 기초검토 의 단계로부터 서서히 실용화를 향한 내구, 신뢰성을 포함한 많은 과제의 검토단계로 이행되고 있다. 수소엔진의 연구는 아직 초보단계에 있으며 안전성에 대해서는 일반이 염려하고 있는 것과 같은 위험성은 없지만 금후 자동차용으로서의 안전성에 관한 실험이 필요할 것이다. 수소의 장 점을 살려 결점을 없애기 위해서는 LH2탱크, LH2펌프 4사이클 실린더내 분사가 이상적으로 생 각되고 있다.

  • PDF

Flame Length Scaling in a Non-premixed Turbulent Diluted Hydrogen Jet with Coaxial Air (희석된 동축공기 수소 난류확산화염의 화염 길이 스케일링)

  • Hwang, Jeong-Jae;Oh, Jeong-Seog;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.242-245
    • /
    • 2009
  • The effect of fuel composition on flame length was studied in a non-premixed turbulent diluted hydrogen jet with coaxial air. The observed flame length was expressed as a function of the ratio of coaxial air to fuel jet velocity and compared with a theoretical prediction based on the velocity ratio. Four cases of fuel mixed by volume were determined. In the present study, we derived a scaling correlation for predicting the flame length in a simple jet with coaxial air using the effective jet diameter in the near-field concept. The experimental results showed that visible flame length had a good relation with the theoretical prediction. The scaling analysis is also valid for diluted hydrogen jet flames with varied fuel composition.

  • PDF

Effect of CO in Anode Fuel on the Performance of Polymer Electrolyte Membrane Fuel Cell (수소연료 중 일산화탄소의 고분자전해질 연료전지에 대한 영향)

  • Kwon, Jun-Taek;Kim, Jun-Bum
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.4
    • /
    • pp.291-298
    • /
    • 2008
  • Carbon monoxide(CO) is one of the contamination source in reformed hydrogen fuel with an influence on performance of polymer electrolyte membrane fuel cell(PEMFC). The studies of CO injection presented here give information about poisoning and recovery processes. The aim of this research is to investigate cell performance decline due to carbon monoxide impurity in hydrogen. Performance of PEM fuel cell was investigated using current vs. potential experiment, long time(10 hours) test, cyclic feeding test and electrochemical impedance spectra. The concentrations of carbon monoxide were changed up to 10 ppm. Performance degradation due to carbon monoxide contamination in anode fuel was observed at high concentration of carbon monoxide. The CO gas showed influence on the charge transfer reaction. The performance recovery was confirmed in long time test when pure hydrogen was provided for 1 hour after carbon monoxide had been supplied. The result of this study could be used as a basis of various reformation process design and fuel quality determination.

Development on Fuel Economy Test Method for Hydrogen Fuel Cell Vehicles (수소연료전지자동차 연료소비율 평가기술 개발에 관한 연구)

  • Lim, Jong-Soon;Lee, Hyun-Woo;Hong, Yun-Seok;Lee, Kwang-Bum;Yong, Gee-Joong;Kwon, Hae-Boung
    • Journal of Hydrogen and New Energy
    • /
    • v.21 no.3
    • /
    • pp.207-213
    • /
    • 2010
  • Fuel consumption measurement of hydrogen fuel cell vehicle is considerably different from internal combustion engine vehicle such as carbon balance method. A practical method of fuel consumption measurement has been developed for hydrogen fuel cell vehicles. There are three method of hydrogen fuel consumption testing, gravimetric, PVT (pressure, volume and temperature), and mass flow, all of which necessitate physical measurements of the fuel supply. The purpose of this research is to measure the fuel consumption of hydrogen fuel cell vehicles on chassis-dynamometer and to give information when the research is intended to develop test method to measure hydrogen fuel economy.

Hydrocarbon Fuel Heating Experiments Simulating Regeneratively Cooled Channels of LRE Combustor (로켓엔진 연소기 재생냉각채널을 모사한 탄화수소계 연료가열시험)

  • Lim, Byoung-Jik;Lee, Kwang-Jin;Kim, Jong-Gyu;Yang, Seung-Ho;Kim, Hui-Tae;Kang, Dong-Hyuk;Kim, Hong-Jip;Han, Yeoung-Min;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.5
    • /
    • pp.78-84
    • /
    • 2007
  • In the regeneratively cooled combustion chambers of liquid rocket engine using hydrocarbon fuels, coking occurs as the wall temperature increases which results in compounds deposition on the wall of cooling channels. This phenomenon reduces cooling capability of the coolant which finally causes damage to the combustor by overheating of the chamber wall. In this paper, experiment results using an electrical heating equipment to simulate the regeneratively cooled channel are introduced and based on the results the compatibility of copper alloy with hydrocarbon fuel Jet A-1 is investigated.

A Study on Anode Fuel Composition of Direct Borohydride/Hydrogen Peroxide Fuel Cell (직접 수소화붕소나트륨/과산화수소 연료전지의 산화극 연료 조성에 관한 연구)

  • LEE, TAE HOON;YU, SU SANG;OH, TAEK HYUN
    • Journal of Hydrogen and New Energy
    • /
    • v.32 no.6
    • /
    • pp.514-523
    • /
    • 2021
  • This study investigated the effect of anode fuel composition on the performance of direct borohydride/hydrogen peroxide fuel cells (DBHPFCs). The effect of sodium borohydride (NaBH4) and sodium hydroxide (NaOH) concentrations on fuel cell performance was determined through fuel cell tests. Fuel cell performance increased with an increase in the NaBH4 concentration, whereas it decreased with an increase in the NaOH concentration. The anode fuel composition was selected as 10 wt% NaBH4+10 wt% NaOH+80 wt% H2O based on the fuel viscosity, electrochemical reaction rate, and decomposition reaction rate. DBHPFCs were also tested to analyze the effect of operating temperature and operation time on fuel cell performance. The present results can be used as a reference basis to determine operating conditions of DBHPFCs.

Dynamic Simulation of Proton Exchange Membrane Fuel Cell Stack under Various Operating Pattern of Fuel Cell Powered Heavy Duty Truck (연료전지 트럭의 운전 부하 패턴에 따른 고분자 연료전지 스택의 동특성 시뮬레이션 )

  • NAMIN SON;MUJAHID NASEEM;UIYEON KIM;YOUNG DUK LEE
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.2
    • /
    • pp.121-128
    • /
    • 2024
  • In this study, a dynamic simulation model of a heavy-duty truck, equipped with a fuel cell power-train, has been developed and the dynamic behavior of the fuel cell stack has bee investigated using. Output change simulations were performed according to several drive cycle load change of a fuel cell truck. Mathworks' Simulink and Simscape program were used to develop the model. The model is comprised of fuel cell power train, power converter system and truck vehicle part. The vehicle runs at targeted speed of the truck, which is set as the load of the system. The dynamic behavior of the fuel cell stack according to the weight difference were analyzed, and based on this, the dynamic characteristics of the fuel cell output power and battery state with simple load was analyzed.

Load Variation Removal and Stack Durability Experiments to Improve Lifetime of Fuel Cell Stack for Hydrogen Electric Vehicles (수소전기차 연료전지 수명 향상을 위한 부하 변동 제거 및 스택 내구성 실험)

  • DONGWON LEE;BEOMJUN KIM;SEOUNGRO LEE
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.4
    • /
    • pp.370-376
    • /
    • 2024
  • Load variations reduce the lifespan of polymer electrolyte fuel cells (PEFCs). To analyze the impact of load variations on durability of PEFCs, two stacks were built and operated continuously for 400 hours, one under load variations and the other under constant current condition with the same energy output. Using the example model provided by Mathworks, we obtained load variation data for the experiments. The performance curves were measured every 100 hours and analyzed by current interruption method and electrochemical impedance spectroscopy. The degradation comparison shows a much larger decrease in performance under the load variation. The activation resistance, electrical resistance, and mass transfer resistance are all found to increase more.