• 제목/요약/키워드: 수막

검색결과 312건 처리시간 0.025초

부인두강 종양으로 발현한 두개외 수막종 (Extracranial Meningioma as a Parapharyngeal Space Tumor)

  • 이대웅;최정욱;오승은;이준규;임상철
    • 대한두경부종양학회지
    • /
    • 제26권2호
    • /
    • pp.259-261
    • /
    • 2010
  • The meningiomas are slowly growing tumors arising from meningoepithelial cells and they generally occur in the intracranial space. Tumor extension to the extracranial structures occurred in about 20 percent of intracranial meningiomas. Meningiomas extending to the cervical area are uncommom. Beacuse these patients complain of localized symptoms, sometimes those tumors have been operated as cervical tumors. In this report, we incidentally found a meningioma in the left parapharyngeal space in a 63-year-old female, who was confirmed by histopathologic diagnosis to have meningioma. We report herewith this case with the review of literatures.

수막을 가지는 선형 젖음성 패턴 표면에서의 액적 거동 특성 (The Behavioral Characteristics of a Droplet on the Line Patterned Surface Including Water Film)

  • 이창우;박진영;조한동;황운봉
    • 한국정밀공학회지
    • /
    • 제30권12호
    • /
    • pp.1335-1340
    • /
    • 2013
  • Herein the water film was introduced to the hydrophilic area on the line patterned surface to solve the contradiction caused by surface roughness (high different wettability has advantage to control the droplet but high roughness for that high wettability difference causes obstruction of droplet moving). Thus the droplet on the water film could not be hindered to line direction but restricted to orthogonal direction, effectively. In addition, droplet behaviors according to droplet volume and line thickness were studied. Droplet fell off the line with narrowing the interface between the droplet and the water film on the line. When the droplet fell off the line, the plate angle was designated as a critical plate angle and it used as an indicator of surface capability to control the droplet. As a result critical plate angle increases as droplet volume decreases and line thickness increases.

채널이 수막으로 완전히 덮여 있는 증발식 냉각기에서의 열 및 물질전달 해석 (Analysis of Heat and Mass Transfer in an Evaporative Cooler with Fully Wetted Channel)

  • 송찬호;이대영;노승탁
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1766-1775
    • /
    • 2001
  • A theoretical analysis on the heat and mass transfer in an evaporative cooler is presented in this work. The evaporative cooler is modeled as a channel filled with porous media the interstitial surface of which is covered by thin water film. Assuming that the Lewis number is unity and the water vapor saturation curve is linear, exact solutions to the energy and vapor concentration equations are obtained. Based on the exact solutions, the characteristics of the heat and mass transfer in the evaporative cooler are investigated. The comparison of the cooling performance between the evaporative cooler and the usual sensible heat exchanger is also carried out. Obviously, the evaporative heat exchanger shows better cooling performance than the sensible heat exchanger. This is due to the latent heat of water vaporization, which results in apparent increases both in the interstitial heat transfer coefficient and the specific heat of the air stream in the evaporative cooler.

흑색 코발트 태양 선택흡수막의 열퇴화 (Thermal Degradation of Black Cobalt Solar Selective Coatings)

  • 이길동
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.9-15
    • /
    • 2015
  • Black cobalt solar selective coatings were prepared by using an electroplating method. The changes in the optical properties of the black cobalt selective coating due to thermal degradation were analyzed by using the Auger electron spectroscopy (AES) and spectrophotometer. The black cobalt selective coating was prepared on a copper substrate by using a synthesized electrolyte with $CoCl_2$ and KSCN at a current density of ${\sim}0.5A/dm^2$ for 45s ~ 60s. Its optical properties were a solar absorptance (${\alpha}$) of the order of 0.80 ~ 0.84 and a thermal emittance (${\epsilon}$) of 0.01. From the AES depth profile analysis of heated sample, thermal degradation of the black cobalt selective coating heated for 33 hours at temperature of $350^{\circ}C$ occurred primarily due to interdiffusion at interface of cobalt and copper substrate. This results were predictable that the ${\alpha}$ decreases due to the thermal oxidation and diffusion.

고온용 태양 선택흡수막의 제작 (Deposition of Solar Selective Coatings for High Temperature Applications)

  • 이길동
    • 한국태양에너지학회 논문집
    • /
    • 제28권1호
    • /
    • pp.33-42
    • /
    • 2008
  • Zr-O ($Zr-ZrO_2$) cermets solar selective coatings with a double cermets layer film structure were prepared using a DC (direct current) magnetron sputtering method. The typical film structure from surface to bottom substrate were an $Al_2O_3$ anti-reflection layer on a double Zr-O cermets layer on an Al metal infrared reflection layer. Optical properties of optimized Zr-O cermets solar selective coating had an absorptance of ${\alpha}\;=\;0.95$ and thermal omittance of ${\epsilon}\;=\;0.10\;(100^{\circ}C)$. The absorbing layer of Zr-O cermets coatings on glass and silicon substrate was identified as being amorphous by using XRD. AFM showed that ZF-O cermets layers were very smooth and their surface roughness were approximately $0.1{\sim}0.2 nm$. The chemical analysis of the cermets coatings were determined by using XPS. Chemical shift of photoelectron binding energy was occurred due to the change of Zr-O cermets coating structure deposited with increase in oxygen flow rate. The result of thermal stability test showed that the Zr-O cermets solar selective coating was stable for use at temperature below $350^{\circ}C$.

범발성 두개내 결핵종 완치 1례 (A Case of Complete Treatment of Multiple Intracranial Tuberculoma)

  • 라은영;이창우
    • Pediatric Infection and Vaccine
    • /
    • 제9권1호
    • /
    • pp.117-121
    • /
    • 2002
  • 어린 영유아에서 결핵성 육아종 및 결핵성 수막염, 속립성 결핵 등의 중증 결핵은 치료 시작시 임상상태와 밀접한 연관이 있으며 경과가 진행될수록 예후가 좋지 못하다. 본 증례에서는 결핵성 육아종과 함께 결핵성 수막염 및 속립성 결핵이 동반된 영아에서 12개월 동안 항결핵 요법을 시행한 후 특별한 임상적, 이학적, 신경학적 이상 소견 없는 완치를 경험하였기에 문헌 고찰과 함께 보고하는 바이다.

  • PDF

흑색 코발트 태양 선택흡수막의 광학적특성과 구조 (Optical Properties and Structure of Black Cobalt Solar Selective Coatings)

  • 이길동
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.48-56
    • /
    • 2011
  • Black cobalt solar selective coatings were prepared by thermal oxidation of electroplated cobalt metal on copper and nickel substrates. The optical properties and structure of the black cobalt selective coating for solar energy utilizations were characterized by glow discharge spectrometry (GDS), ultraviolet-visible-near infrared (UV-VIS-NIR) spectrometer, atom force microscopy(AFM) and X-ray photoelectron spectroscopy(XPS). The optical properties of optimum black cobalt selective coating prepared on copper substrate were a solar absorptance of 0.82 and a thermal emittance of 0.01. From the GDS depth profile analysis of these coatings, the concentration of cobalt particles near the interface was higher than at the surface, but oxygen concentration at the surface was higher than at the interface. These results suggest that the selective absorption was dominated by this chemical composition variation in the coating. The surface of this film exhibited morphology with root-mean-square(rms) roughness of about 144.3nm. XPS measurements data showed that several phases of Co coexist($Co_3O_4$,CoO) in the film.

수막뇌염을 모방한 드문 뇌 자기공명영상 소견을 보인 하시모토 뇌병증: 증례 보고 및 문헌고찰 (Hashimoto's Encephalopathy with Unusual MRI Findings Mimicking Meningoencephalitis: A Case Report and Literature Review)

  • 서희붐;김현석;김학진
    • 대한영상의학회지
    • /
    • 제81권2호
    • /
    • pp.453-458
    • /
    • 2020
  • 하시모토 뇌병증은 다른 대뇌 질환의 증거가 없이 항갑상선 항체의 높은 혈청 농도를 특징으로 하는 드문 자가 면역 질환이다. 하시모토 뇌병증의 자기공명영상 소견은 비특이적이고, 현재까지 미만성 또는 국소 백질 변화가 보고 된 바 있다. 저자는 증가된 항갑상선 항체와 동반하여 수막뇌염과 유사한 영상 소견을 보인 79세 여성의 하시모토 뇌병증을 경험하여 이에 대해 보고하고자 한다. 환자의 일련의 자기공명영상에서 치료 전 관찰되던 여러 T2-고강도 병변과 미만성의 뇌수막 조영증강은 스테로이드 요법 후 소실되었다.

부산 지역 신생아에서 발생한 세균성 수막염의 원인균에 관한 연구 (The etiology of neonatal bacterial meningitis in Busan, Korea)

  • 김성헌;박희주;박수은;홍유라;이영아;신종범
    • Pediatric Infection and Vaccine
    • /
    • 제14권1호
    • /
    • pp.43-46
    • /
    • 2007
  • 목 적 : 신생아의 세균성 수막염은 이환률과 사망률이 높으며 생존한 경우에도 신경학적 후유증의 빈도가 높은 질환으로 알려져 있다. 본 연구에서는 1997년부터 2005년까지의 부산 지역에서 발생하였던 신생아 세균성 수막염의 임상 양상에 대하여 알아보고자 하였다. 방 법 : 1997년 1월부터 2005년 12월까지 부산지역 4개 대학 병원 소아과에서 세균성 수막염으로 입원한 환자 중에서 생후 60일 미만의 21명의 신생아를 대상으로 하여 수막염의 발생시기, 주 증상, 원인 균주, 합병증 등을 조사하였다. 이들 중 뇌척수액 배양에서 균주가 동정되었거나, 뇌척수액 검사에서 백혈구가 30개 이상이며, 혈액 배양에서 균주가 동정되었던 경우만 대상으로 하였고, S. epidermidis가 동정된 경우와 원내 감염 및 선천성 기형은 제외 하였다. 결 과 : 대상 환아 중 남아는 11명, 여아는 10명이었으며, 미숙아가 1명이었다. 발생 시기는 생후 2-3주가 7례로 가장 많았으며 생후 1-2주가 6례, 4주 이상의 경우가 5례였고, 1주 미만의 경우는 3례로 빈도가 가장 낮았다. 입원 당시의 주 증상으로는 발열이 18례, 경련이 8례, 수유 불량, 기면, 구토, 보챔 등의 순이었다. 원인 균주로는 GBS가 11례로 가장 많았으며, E.coli와 Klebsiella pneumoniae가 각각 3례를 차지하였고, S. pneumoniae가 2례, Listeria monocytogens와 Enterobacter cloacae가 각각 1례였다. 치료 결과 생존한 환아가 18명, 사망한 환아는 3명이었고, 생존한 환아 중 1례에서 정신지체, 발달 지연, 경련성 질환 등의 장애가 발생하였다. 결 론 : 배양 검사로 확진된 신생아기에 발생한 뇌수막염의 원인균으로는 알려진 사실과 같이 GBS가 가장 흔했다. 외국과 비교하여 현재 국내 배양 검사의 민감도를 생각해 볼 때 향후 민감도의 질적 향상이 필요하며 국내의 발생률 및 임상양상에 대하여 장기간의 추적 검사를 통한 대규모의 전향적인 연구가 필요할 것으로 생각된다.

  • PDF

무심천 인근 상대리 수막재배지에서 지하수 사용 후 배출되는 최종 배수로 물의 수질 특성 (Water Quality in a Drainage System Discharging Groundwater from Sangdae-ri Water Curtain Cultivation Area near Musimcheon Stream, Cheongju, Korea)

  • 문상호;김용철;황정
    • 자원환경지질
    • /
    • 제48권5호
    • /
    • pp.409-420
    • /
    • 2015
  • 우리나라의 대표적 딸기 수막재배지 중 하나인 청주시 가덕면 상대리 일대에서는 수막재배용 지하수 이용량이 몇가지 방법으로 산정된 바 있다. 이러한 지하수 이용량 산정 방법 중에는 수막재배 사용 후 배출되는 배수로의 유량을 근거로 하는 것이 있으며, 이러한 방법은 배수로의 물이 모두 사용 후 배출되는 지하수로만 구성되어 있다는 가정 하에 적용된다. 연구지역에서 지하수가 사용된 후 무심천으로 유출되기 직전의 최종 배수로는 비포장 상태이며 하천 가까이에 나란히 개설되어 있다. 이러한 상황에서는 배수로의 물이 인근 하천수의 침투 유입에 의한 영향을 받을 가능성이 있다. 이 연구는 상대리 지역에서와 유사한 하천과 배수로의 구조 및 형태를 가지는 경우에, 최종 배수로의 배출수가 수질의 관점에서 하천수의 영향을 받고 있는지의 여부를 검토해 보았다. 고려된 수질 요소는 현장 수온과 pH, EC 값, 실내 분석에 의한 이온 함량과 수질 유형이며, 현장 측정 및 시료 채취 기간은 2012년 2월부터 2015년 2월까지이다. 검토 결과, 배출수는 지하수의 평균 수질을 반영하지 않으며, 오히려 하천수의 수질을 많이 반영하는 것으로 나타났다. 이로 보아, 연구지역에서와 같이 배수로가 인근 하천 가까이에서 비포장 상태를 유지하는 경우에는, 배출수의 유량 측정을 지하수 이용량 산정에 직접적으로 이용하는 데에 많은 주의가 필요한 것으로 판단되었다. 이 연구에서 배출수의 수온은 주변 대기 온도에 매우 민감하게 반응하여 변하기 때문에, 하천수의 영향을 정량적으로 판단하기는 부적절한 요소인 것으로 나타났다. 향후 배출수 내 지하수와 하천수의 혼합 비율을 정량적으로 산정하는 연구가 병행되어야 할 것으로 사료된다.