• Title/Summary/Keyword: 수동시스템

Search Result 1,283, Processing Time 0.03 seconds

Seismic Performance Improvement of Base Isolated Buildings using Smart Passive Control System (스마트 수동 제어 시스템을 이용한 면진 건물의 내진 성능 개선)

  • Jung, Hyung-Jo;Jung, Chan-Kuk;Choi, Kang-Min;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.37-46
    • /
    • 2006
  • In this study, the efficacy of the newly developed smart passive control system to improve seismic performance of base isolated building structures is numerically verified. The smart passive control system consists of a magnetorheological (MR) damper and an electromagnetic induction (EMI) part. The damping characteristics of an MR damper can be controlled by the current generated in an EMI part according to the Faraday's law of electromagnetic induction. An EMI part consisting of a permanent magnet and a solenoid coil could substitute a control system including sensors, a controller and an external power supply in a conventional smart control system. The benchmark control problem for a base isolated building presented by the american society of civil engineers is considered for numerical simulation. The control performance of the smart passive control system is compared to that of the conventional smart control system using MR dampers. It is demonstrated from the numerical simulation results that the smart passive control system is useful to improve the seismic performance of base isolated buildings.

A Study to Relation between Human Judgment and Automatic Evaluation in English-Korean Scientific Paper MT System (영한 논문 번역시스템의 수동 평가와 자동 평가의 관계)

  • Choi, Sung-Kwon;Hwang, Young-Sook;Kim, Young-Gil
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.05a
    • /
    • pp.65-68
    • /
    • 2008
  • 본 논문은 영한 과학기술 논문 자동번역 시스템을 대상으로 이루어진 수동 평가와 자동 평가 사이의 상관 관계를 밝힘으로써 수동 평가와 자동 평가 중에 한쪽의 방법에 의해서 평가가 이루어지더라도 다른 쪽의 수치를 파악할 수 있도록 하는데 목표가 있다. 본 논문에서 수행한 수동 평가는 5 인의 전문 번역가가 5 회에 걸쳐 평가한 결과이며, 자동 평가는 영어 원문 1,000 문장에 대한 8 인이 번역한 8,000 문장의 정답문(References)과 자동번역 결과를 어절 단위와 형태소 단위로 N-gram 비교를 통해 평가된 결과이다. 본 논문에서 도출된 식은 사용하는 평가 집합과 대상 번역 시스템 별로 자동 평가와 수동 평가 간의 상관 계수를 만들어내고 수동 번역률을 구하는 식을 동일하게 적용한다면 시스템의 자동 평가 결과로부터 성능을 직관적으로 해석하는데 상당히 도움이 될 것이다.

A Study on the Passive Filter Control System to reduce harmonic of DC Motor drives (직류전동기 구동장치의 고조파 저감을 위한 수동필터 제어시스템 연구)

  • Lee Sang Ick;Yoo Jae Geun;Jeon Jeong Chay
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.280-282
    • /
    • 2004
  • 본 논문에서는 고조파 저감을 위해 사용하는 수동필터를 부하의 운전조건에 따라 자동으로 $개\cdot폐$할 수 있는 DSP 기반의 제어시스템을 개발하였다. 수동필터 제어시스템은 부하에서 발생하는 전압, 전류, 고조파, 무효전력, 역률 등을 측정 및 감시하여 수동필터 $개\cdot폐$ 장치에 신호를 보내어 부하의 운전조건에 따라 필터의 각 분로를 자동으로 $개\cdot폐$하게된다. 이러한 제어시스템은 100마력 직류전동기 구동장치를 사용하는 계통에 수동필터와 함께 설치하고 고조파 및 무효전력등을 측정함으로써 성능을 입증하였다.

  • PDF

Performance Evaluation of the New Smart Passive Control Device using Shaking Table Test (진동대 실험을 통한 신개념 스마트 수동제진장치의 제진성능 평가)

  • Jang, Dong-Doo;Jung, Hyung-Jo;Moon, Seok-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.27-35
    • /
    • 2010
  • This paper presents the vibration control performance of the smart passive control system to suppress the undesired vibration of the structure subjected to the earthquake loadings. Smart passive control system is the MR damper-based control system augmented with electromagnetic induction(EMI) device which consists of permanent magnets and solenoid coils. According to the Faraday's law of electromagnetic induction, an EMI device produces electrical energy from the mechanical energy due to the reciprocal motions of the structure and provide it to the MR damper. The smart passive control system can be the simple and easy to implement and maintain control system by replacing the feedback control system including sensors, controllers and external power sources of the conventional MR damper-based semiactive control system with the EMI device. The control performance of the smart passive control system is evaluated through the set of shaking table test considering the various historical earthquake loadings.

A Study on the Control System of Passive Filter to Reduce Harmonics (고조파 저감을 위한 수동필터의 제어시스템에 관한 연구)

  • 전정채;유재근;이상익
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.124-130
    • /
    • 2004
  • In this paper, we developed DSP(Digital Signal Processor)-based control system to automatically open and close passive filter, which is used to reduce harmonics, according to operating condition of loads. Passive filter control system automatically open and close each branch of filter according to working conditions of loads by sending signals to open and close installation of passive filter after measuring and monitoring voltage, current, harmonics, reactive power, power factor and so on. We verified it's performance by connecting control system with passive filter in the power line using the 100HP D.C motor drive, opening and closing passive filter according to operation condition of motor, and measuring harmonics and reactive power, etc.

Smart Passive System Based on MR Damper (MR댐퍼 기반의 스마트 수동제어 시스템)

  • Cho, Sang-Won;Jo, Ji-Seong;Kim, Chun-Ho;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.51-59
    • /
    • 2005
  • Magnetorheological(MR) dampers are one of the most promising semi active control devices, because they have advantages such as small power requirement, reliability, and low price to manufacture. To reduce the responses of structures with MR dampers, a control system including power supply, controller, and sensors is required. However, when a mount of MR dampers are used to a large?scale civil structure such as cable stayed bridges, the control system becomes complex. Therefore, it is not easy to install and maintain the MR damper based control system. To resolve above difficulties, This paper proposes a smart passive system that consists of a MR damper and an electromagnetic induction(EMI) system. According to the Faraday’s law of induction, EMI system that is attached to the MR damper produces electric energy. The produced energy is supplied to the MR damper. Thus, the MR damper with EMI system does not require any power at all. Furthermore, the induced electric energy is proportional to external loads like earthquakes, which means the MR damper with EMI system is adaptable to external loads without any controller and corresponding sensors. Therefore, it is easy to build up and maintain the proposed smart passive system.

Studies on the millimeter-wave Passive Imaging System III (밀리미터파 수동 이미정 시스템 연구 III)

  • Jung, Min-Kyoo;Chae, Yeon-Sik;Kim, Soon-Koo;Yoo, Jin-Seob;Koji, Mizuno;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.3 s.357
    • /
    • pp.111-116
    • /
    • 2007
  • We have developed a passive millimeter wave (PMMW) imaging system with two-dimensional imaging arrays. For the imaging system we achieved single-substrate imaging-array element which include all necessary component such as Fermi tapered slot antenna (TSA), a balun, LNA's and a detector circuit on it. Two-dimensional arrays for real-time imaging at the 35 GHz band are currently under development. We will be able to make an advanced PMMW image system based on our system with the $2\times2$ imaging array in the near future.

Development of Passive Nutrient Supplying System and Its Effects on the Growth of Muskmelon (Cucumis melo L.) (수동방식 양액공급 시스템 개발과 멜론 재배 효과)

  • Nam, Sang-Sik;Oh, Yong-Bee;Kim, Yong-Bum;Choi, In-Hu
    • Horticultural Science & Technology
    • /
    • v.19 no.3
    • /
    • pp.338-341
    • /
    • 2001
  • A new passive nutrient supplying system (PNS) was designed. The experiment was conducted to compare PNS with automatic hydroponic system (AHS) by investigating the growth characteristics of muskmelon (Cucumis melo L.) in spring and summer. No significant differences in growth characteristics of leaf area and shoot dry weight were observed between PNS and AHS. However, better netting of melon fruit was shown in PNS. Sugar content of melon fruit was also $1.0-2.0Brix^{\circ}$ higher in PNS than in AHS. The suitable substrate for melon culture with PNS was the mixture of perlite 70% and rice hull 30%. These results suggested that new PNS could be introduced to growers without any loss of fruit yield and quality of muskmelon.

  • PDF

Manual and Automatic Steering System Using Pulley and Electrical Clutch for Manned and Unmanned Electric Vehicle (풀리 및 전자클러치를 이용한 유무인 전기자동차용 수동 및 자동조향장치)

  • Lee, Yong-Jun;Ryoo, Young-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.5
    • /
    • pp.597-602
    • /
    • 2012
  • In this paper, a manual and automatic steering system for electric vehicles capable of manned and unmanned driving is proposed. The automatic steering systems, EPS, MDPS, used in conventional engine based car includes the problem of handle lock phenomenon while driving of overloading, therefore it has a drawback to apply to manned and unmanned electric vehicles. By using electronic clutch and pulleys, the proposed manual and automatic steering mechanism was designed so that it is possible to convert from manual to automatic steering mode. To experiment the performance of the proposed steering system, we made an experimental setup of an electric vehicle. We confirmed that the proposed manual and automatic steering system was useful for manned and unmanned electric vehicles.

태양열을 이용한 주택설계안 - 외국례

  • Hong, Seong-Mok
    • Korean Architects
    • /
    • no.8 s.126
    • /
    • pp.47-51
    • /
    • 1979
  • 태양열이용주택의 외국자료중 일리노이주 에너지 및 건축 위원회에서 주최한 현상설계모집에 당선된 당선작중 DAVID. C. YOUNG씨 안과 STEPHEN R. STOCK씨안을 소개한다. YOUNG씨 안은 수동시스템(Passive system)의 대표적인 예의 작품으로 소개할 수 있으며 STOCK씨안은 능동시스템(Active system)의 좋은 예로 소개하고 싶다. 여기서는 단독 예만을 소개하고 집합주택의 능동시스템을 제외하였다.

  • PDF