• Title/Summary/Keyword: 솔레노이드 센서

Search Result 33, Processing Time 0.044 seconds

A Study on the Design and Performance Evaluation Technology of Fieldbus Pneumatic Solenoid Valve/Sensor System (필드버스 공압 솔레노이드 밸브/센서시스템 설계 및 성능평가 특성해석)

  • Kim, D.S.;Hong, C.P.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.865-870
    • /
    • 2001
  • For pneumatic system control, we need a data transmission system with high speed and high reliability or information interchange between main computer and solenoid valves and I/O devices. This paper presents a set of design techniques for a data communication system that is mainly used for pneumatic system control. For this purpose, we first designed hardware modules for an interface between central control module and local node that handles the operation of solenoid valves. In addition we developed a communication protocol for construction of RS-485 based multidrop network, and this protocol is basically designed with a kind of polling technique. Finally we evaluated performance of the developed system. The field test results show that, even under high noise environment, the data transmission of 375Kbps rate is possible up to 1,000m without using repeater. In addition, the system developed in this research is proved to be used easily for extension of a communication network because of its module structure.

  • PDF

A Study on the Design and Embodiment of Educational Automatic Purification Facility of Waste Water (교육용 자동 폐수 정화시설의 설계와 구현에 관한 연구)

  • Kim, Moon-Ki
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.4 no.2
    • /
    • pp.7-12
    • /
    • 2012
  • In this research, an educational automatic purification facility of waste water is designed. The system has four functions which are filter tank, aeration tank, reactor tank and ultraviolet sterilization tank, and is embodied by PLC(Programmable Logic Controller), DC motor, solenoid valve, squirt gun, propeller, profile, switch, sensor and so on. Also, the system is designed and manufactured based on knowledges which are obtained from college education. The study is emphasized on "learning by doing". From this case study, students can increase their originality and adaptability for related industry. Also, the technique can be initiated industry if needed.

  • PDF

Development of a Non-contact Type Magnetic Signal Monitoring Equipment for Automotive Electric Devices (비접촉식 자동차 전장용 자기신호 측정 장치)

  • Yang, Hyong-Yeol;Yang, Seung-Hak
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.381-386
    • /
    • 2010
  • A non-contact type magnetic signal monitoring equipment for automotive electric devices is proposed in this paper. There are many kinds of actuators in the car like solenoid, relay, motor, injector, etc which are operated by magnetic energy. It is difficult to find out whether the actuators operate well or not because the terminals of the actuators are combined to the connectors. In this paper a non-contact type magnetic signal monitoring equipment using Hall effect sensor is proposed to measure the magnetic signal of the actuators very easily to find out the actuators' operating status. The simulation and experimental results show that the developed equipment is very useful and has good performance.

A LPG Dispensing Control System based on a 16-bit Microprocessor (16-bit 마이크로프로세서로 구현한 LPG 충전 제어 시스템)

  • 이상훈;홍남관
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.2
    • /
    • pp.83-88
    • /
    • 2002
  • In this paper, a POS interfacing and temperature compensable LPG dispensing control system(LDCS) has been developed. A LDCS includes a 16-bit 80C196 microprocessor, RAM, ROM, video driver, and programmable peripheral devices. Based on gas flow encoding pulse, temperature-voltage conversion values and apparatus calibration values, the LDCS controls the LPG dispensing quantity with switching on or off the solenoid valves. The temperature compensation is performed with a 10-bit A/D conversion and its range is from +7$0^{\circ}C$ to -3$0^{\circ}C$ with a 0.5$^{\circ}C$ resolution.

  • PDF

MEMS-based Micro Fluxgate Sensor Using Solenoid Excitation and Pick-up Coils (MEMS 공정 제작방법에 의한 솔레노이드형 여자 코일과 검출코일을 사용한 마이크로 플럭스게이트 센서)

  • 나경원;박해석;심동식;최원열;황준식;최상언
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.2
    • /
    • pp.120-124
    • /
    • 2003
  • This paper describes a MEMS-based micro-fluxgate magnetic sensing element using Ni$\_$0.8/Fe$\_$0.2/ film formed by electroplating. The micro-fluxgate magnetic sensor composed of a thin film magnetic core and micro-structure solenoids for the pick-up and the excitation coils, is developed by using MEMS technologies in order to take advantage of low-cost, small size and lower power consumption in the fabrication. A copper with 20${\mu}$m width and 3${\mu}$m thickness is electroplated on Cr (300${\AA}$) / Au (1500${\AA}$) films for the pick-up (42turn) and the excitation (24turn) coils. In order to improve the sensitivity of the sensing element, we designed the magnetic core into a rectangular-ring shape to reduce the magnetic flux leakage. An electroplated permalloy film with the thickness of 3${\mu}$m is obtained under 2000 gauss to induce magnetic anisotropy. The magnetic core has the high DC effective permeability of ~1,100 and coercive field of ~0.1 Oe. The fabricated sensing element using rectangular-ring shaped magnetic film has the sensitivity of about 150 V/T at the excitation frequency of 2 MHz and the excitation voltage of 4.4 V$\_$p p/. The power consumption is estimated to be 50mW.

Design and Implementation of Optical Signal Processor in Fiber-Optic Current Transducer for Electric Equipments (전력기기용 고안정성 광섬유 CT 센서의 광 신호처리기 설계 및 구현)

  • Jang, Nam-Young;Choi, Pyung-Suk;Eun, Jae-Jeong;Cheong, Hyeon-Seong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.171-177
    • /
    • 2007
  • In this paper, we have designed and implemented an optical signal processor in order to use in a fiber-optic current CT for electric equipments where its properties were discussed. The fabricated optical signal processor is used to reduce a measurement current error that induced by the effects of intensity variation in the optical output signal due to losses coming from optical components or polarization variation in a PFOCS. Also, the optical signal processor was fabricated in compact/lightweight with unification of opto-electronic transducer part, analog signal process part, and real-time measurement part consisted of a level shift and ${\mu}-processor$. The experiment of optical signal processor has been performed in the range of $0{\sim}7,500A$ using the PFOCS made all fiber-optic components. As a result of experiment, the linearity error of measurement current is less than 1.7% and its average error is less than 0.3% in the range of $1,000A{\sim}7,000A$.

  • PDF

A Design and Implementation of CO2 Infuser for a Carbon Dioxide (카복시 테라피용 CO2 주입기의 설계 및 구현)

  • Park, Sung-Kon;Ahn, Chan-Jin
    • Journal of Digital Contents Society
    • /
    • v.16 no.3
    • /
    • pp.483-492
    • /
    • 2015
  • This thesis analysis the CARBO 3000 that is one of a $CO_2$ infuser and improve its effectiveness. The thesis designs H/W and S/W that controls the $CO_2$ infusing mass compared to the CARBO 3000. Specially the designed H/W has a newly CPU, LCD, a flow velocity controller, a solenoid valve and a flow sensor. Also the designed S/W is composed of GUI and the algorithm to control the $CO_2$ infusing mass. The designed and implemented the $CO_2$ Infuser in this thesis is tested for the performance. The commercial measuring sensor is used for the test. The testing results say that the designed and implemented the $CO_2$ Infuser in this thesis is much more accurate compared to the CARBO 3000 on $CO_2$ infusing.

Characteristics of Mineral Mg Dissolving Sensor in Edible Water using GMR-SV Device (거대자기저항 스핀밸브 소자를 이용한 음용수 미네랄 Mg 용해센서 특성 연구)

  • Lee, Ju-Hee;Kim, Da-Woon;Kim, Min-Ji;Park, Kwang-Seo;Kang, Joon-Ho;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.5
    • /
    • pp.174-179
    • /
    • 2008
  • The measurement dissolution sensor system using GMR-SV device with magnetic sensitivity of 0.8 %/Oe and Mg-film thick of 200 nm and Mg-foil thick of 50 mm was fabricated and characterized. During the water dissolving process of Mg-film and Mg-foil, the subtle variation of magnetic field by the decrease of current in solenoid was detected by the GMR-SV sensor. The variations of Mg bubble number and ORP as a function of time for three different kinds of edible, tap, and distilled water, are measured and compared. A After 45 min, the speed of fast dissolving Mg was shown the order of edible > tap > DI water. The variation of output magnetoresistance as a function of dissolved time of Mg-film and Mg-foil for edible water, which is composed of mineral content of $0.8{\sim}5.4\;mg/l$ was investigated. The response times for the dissolution in edible water were 5 min and 20 min, respectively. From the measurement of dissolving time and speed for Mg-film and Mg-foil using GMR-SV device, the mineral Mg sensor system in edible water can be possible to develop.

A New LC Resonator Fabricated by MEMS Technique and its Application to Magnetic Sensor Device (MEMS 공정에 의한 LC-공진기형 자기센서의 제작과 응용)

  • Kim, Bong-Soo;Kim, Yong-Seok;Hwang, Myung-Joo;Lee, Hee-Bok
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.3
    • /
    • pp.141-146
    • /
    • 2007
  • A new class of LC-resonator for micro magnetic sensor device was invented and fabricated by means of MEMS technique. The micro LC-resonator consists of a solenoidal micro-inductor with a bundle of soft magnetic microwire cores and a capacitor connected in parallel to the micro-inductor. The core magnetic material is a tiny glass coated $Co_{83.2}B_{3.3}Si_{5.9}Mn_{7.6}$ microwire fabricated by a glasscoated melt spinning technique. The core materials were annealed at various temperatures $150^{\circ}C,\;200^{\circ}C\;,250^{\circ}C\;,$ and $300^{\circ}C$ for 1 hour in a vacuum to improve soft magnetic properties. The solenoidal micro-inductors fabricated by MEMS technique were $500{\sim}1,000{\mu}m$ in length with $10{\sim}20$ turns. The changes of inductance as a function of external magnetic field in micro-inductors with properly annealed microwire cores were varied as much as 370%. Since the permeability of ultra soft magnetic microwire is changing rapidly as a function of external magnetic field. The inductance ratio as well as magnetoimpedance ratio (MIR) in a LC-resonator was varied drastically as a function of external magnetic field. The MIR curves can be tuned very precisely to obtain maximum sensitivity. A prototype magnetic sensor device consisting of the developed microinductors with a multivibrator circuit was test successfully.

433 MHz Radio Frequency and 2G based Smart Irrigation Monitoring System (433 MHz 무선주파수와 2G 통신 기반의 스마트 관개 모니터링 시스템)

  • Manongi, Frank Andrew;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.6 no.2
    • /
    • pp.136-145
    • /
    • 2020
  • Agriculture is the backbone of the economy of most developing countries. In these countries, agriculture or farming is mostly done manually with little integration of machinery, intelligent systems and data monitoring. Irrigation is an essential process that directly influences crop production. The fluctuating amount of rainfall per year has led to the adoption of irrigation systems in most farms. The absence of smart sensors, monitoring methods and control, has led to low harvests and draining water sources. In this research paper, we introduce a 433 MHz Radio Frequency and 2G based Smart Irrigation Meter System and a water prepayment system for rural areas of Tanzania with no reliable internet coverage. Specifically, Ngurudoto area in Arusha region where it will be used as a case study for data collection. The proposed system is hybrid, comprising of both weather data (evapotranspiration) and soil moisture data. The architecture of the system has on-site weather measurement controllers, soil moisture sensors buried on the ground, water flow sensors, a solenoid valve, and a prepayment system. To achieve high precision in linear and nonlinear regression and to improve classification and prediction, this work cascades a Dynamic Regression Algorithm and Naïve Bayes algorithm.