• Title/Summary/Keyword: 손상 사례

Search Result 399, Processing Time 0.028 seconds

Digital Restoration of Cultural Properties Based on Virtual Reality (가상현실 기술을 이용한 문화재의 디지털 복원)

  • 박소연;양종열
    • Archives of design research
    • /
    • v.16 no.1
    • /
    • pp.219-228
    • /
    • 2003
  • Nowadays, the progress of high technology in modern society provides humankind with the opportunity to obtain diverse information easily and quickly. Among those rapidly progressing fields of high technology, digital media field has the ability to substitute for the multimedia information society by being applied to many related fields and daily life. Specifically, the concern and enthusiasm for the restoration of cultural property has risen. So, effective methods are required to decide on the preservation, restoration and academic value of cultural property. Among these, image processing technology using computers has been introduced. The restoration of cultural property using this technique has been studied vigorously in many advanced countries because this would allow us to restore damaged parts without destroying the original asset. However, in Korea, though we have numerous examples of cultural property with recorded history, research related to the items has scarcely been conducted. Accordingly, this study focuses on the investigation of virtual reality and the techniques applicable to restoring cultural property in addition to suggesting the significance and possibility of digitally restoring cultural property following the introduction of applicable examples both domestically and abroad.

  • PDF

Evaluation of Fatigue Crack Growth Rate on the Surface of Steel Members Using COD(Crack Opening Displacement) Measurement (COD(Crack Opening Displacement) 측정에 의한 강재표면의 피로균열진전속도 평가)

  • Kim, Kwang Jin;Kim, In Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.179-188
    • /
    • 2011
  • Steel structures have been allowed to have fatigue damage tolerance in fact. If it would be assessed whether fatigue crack is growing or not and How fast fatigue crack is propagating, we should make a rational decision on methods and a period of reinforcement in the maintenance. In this study, fatigue crack growth tests on two kinds of through-thickness cracked steel plates and a out-of-plane gusset welded joint were conducted to evaluate fatigue crack growth rate using the COD(Crack Opening Displacement), and COD measurement using strain gauges was examined to offer a practical method. As a result, we proposed a reasonable assessing method for fatigue crack growth rate using the COD and it was experimentally proved practical to estimate the COD through measuring strains.

Vibration Control of a Beam with a Tip Mass using a Lightweight Piezo-composite Actuator (경량 압전 복합재료 작동기를 이용한 끝단 질량이 부착된 보의 진동 제어)

  • Martua, Landong;Park, Hoon-Cheol;Goo, Nam-Seo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.3
    • /
    • pp.218-224
    • /
    • 2007
  • Although piezoelectric materials such as PZT have been widely used as actuators in the field of active vibration suppression, the use of bare PZT as an actuator may cause some drawbacks such as critical breaks in the installation process, short circuits in the host material and low fatigue performance. The LIPCA-C2 (lightweight piezocomposite actuator) was developed to alleviate these problems. We implemented the LIPCA as an actuator to suppress the vibration of an aluminum cantilever beam with a tip mass. In our test, we used positive position feedback control algorithm. The filter frequency for this type of feedback should be tuned to the natural frequency of the target mode. The first three experimental natural frequencies of the aluminum cantilever beam agree well with the results of finite element analysis. The effectiveness of using the LIPCA as an actuator in active vibration suppression was investigated with respect to the time and frequency domains, and the experimental results show that LIPCAs with PPF control can significantly reduce the amplitude of forced vibrations and the settling time of free vibrations. For a case study, the forced vibration control of several beams with different thicknesses were performed.

Effects of Using PNF in Progressive Sitting Position on Dynamic Balance in a Patient with a Cerebellar Injury -Single Subject Design- (점진적 앉은 자세에서의 PNF운동이 소뇌 손상환자의 동적 균형능력에 미치는 효과 -단일 사례 연구-)

  • Kim, Dae-Kyeong;Na, Eun-Jin;Moon, Sang-Hyun
    • PNF and Movement
    • /
    • v.14 no.2
    • /
    • pp.149-155
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the effects of using proprioceptive neuromuscular facilitation (PNF) exercise in the progressive sitting position on the dynamic balance ability of a patient with a cerebellar injury. Methods: The subject had ataxia due to cerebellar injury. The subject participated in a PNF bilateral scapular pattern exercise with stabilizing reversal technique during a progressive sitting position session as well as baseline for 20 minutes a day for 4 weeks. In the first session, PNF exercises were performed at a height of 40 cm for 10 minutes, and in the second session they were performed at 50 cm for 10 minutes from a lower center of gravity (COG) to a higher COG sitting position. We used the Berg Balance Scale (BBS), Five-Times-Sit-to-Stand Test (FTSST), and the Timed Up and Go Test (TUGT) to measure the subject's dynamic balance ability every two days through the entire session. Results: After participating in the program, the subject's dynamic balance ability improved compared to the first baseline, as measured by BBS (2 points increased), FTSST (5.3 sec decreased), and TUGT (2 sec decreased). The increase was also maintained in the second baseline session. Conclusion: PNF exercise using bilateral scapula patterns with a stabilizing reversal technique helps to enhance the dynamic balance ability of a cerebellar injury patient.

Influence of the Nozzle Contraction Angles of Gaseous Extinguishing Systems on Discharge Noise (가스계 소화시스템 노즐 수축각이 방출소음에 미치는 영향)

  • Kim, Yo-Hwan;Yoo, Han-Sol;Hwang, In-Ju;Kim, Youn-Jea
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.77-82
    • /
    • 2019
  • Fire extinguishing systems are essential equipment in all indoor facilities to address unexpected fire scenarios, and appropriate fire extinguishing agent should be used depending on the place and object to protect. Among these, gaseous fire-extinguishing systems are used to protect electronic equipment. Therefore, inert gases that do not undergo chemical reactions are used mainly in those systems. On the other hand, recently, owing to the high integration of electronic equipment, there are some cases, in which large noise generated from gaseous systems damage the electronic equipment. In this study, numerical analysis of the discharge noise with various nozzle contraction angles was carried out to improve the gas fire extinguishing system. Numerical analysis was carried out using ANSYS FLUENT ver 18.1. The causes of the noise were elucidated using the swirl distribution. The noise level of the modified model was reduced by approximately 6 dB compared to the reference model, which is similar to the result of a previous study, confirming the validity of the method.

Experimental Investigation of the Shear Behavior of RC Beams Strengthened with Glass Fiber-Steel Composite Plate(GSP) (유리섬유-강판 복합재료(GSP)로 보강된 RC 보의 전단거동에 관한 실험적 연구)

  • Jang, Jun-Hwan;Kim, Seong-Do;Cho, Baik-Soon;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.1
    • /
    • pp.130-140
    • /
    • 2007
  • Fiber-sheet and steel-plate strengthening methods have been mainly used for strengthening the RC structures. However, recently the application of these two methods have dramatically decreased due to premature debonding failure between concrete surface and fiber-sheet and heavy self-weight of steel-plate. This article presents experimental results of shear behavior in RC beams strengthened with GSP(Glass fiber-Steel composite Plate). The thin steel plate in GSP makes usage of the anchoring system possible, which could delay or prevent the premature debonding failure. Three reference beams and 60 strengthened beams with GSP were tested. The experimental results showed that strengthened beams with GSP considerably increased in shear capacity compared with the reference beams.

Revisiting root resection treatment in the age of dental implants (임플란트 시대의 치근절제술의 다양한 활용증례 및 부가적 효용)

  • Joo, Ji-Young;Kwon, Eun-Young;Lee, Ju-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.232-239
    • /
    • 2016
  • Purpose: In this paper, we introduce a wide clinical application of root resection therapy and additional benefits on the next prosthetic or dental implant treatment procedures in the age of dental implants. Materials and Methods: Additional clinical benefits of root resection were monitored by clinical and radiographic evaluation. Results: No complication was reported in all the cases, and the favorable results of root resection were maintained for long period. Conclusion: In compromised multirooted teeth, variety clinical treatment modality should be considered for enhancing the reconstruction of alveolar ridge around root resected in preparation for next implantation.

Development of FBG Accelerometer for Railway Tunnel Vibration (철도터널 진동 모니터링을 위한 광섬유 가속도계 개발)

  • Lee, Su-Hyung;Shin, Min-Ho;Kim, Hyun-Ki;Lee, Kyu-Wan
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.364-369
    • /
    • 2011
  • For the safety management of tunnel, effective measurements should be continuously carried out. Most of sensors currently being applied for tunnels measure only the local status, thus many of them are needed to monitor an entire tunnel. For the railway tunnel where trains of same conditions are regularly operated, dynamic responses of tunnel structure to train operations can be a good index to estimate the deformation of tunnel structure in wide area. Meanwhile, the electromagnetic interference caused by overhead centenary in railway tunnel obstructs the use of electric-based sensors. In this study a brand new accelerometer using FBG optical fiber sensors is developed to solve these problems. Sensitivity and capacity of the accelerometer are enhanced with effective structural design of its components and verified with laboratory tests. A case history where the developed accelerometers were applied to a safety monitoring system of a high-speed train tunnel is presented. The performances of the developed accelerometers are validated from the measured acceleration data.

A Case Study on Settlement Promotion of a Large Size Open Caisson using Air-Jet an Method (공기분사공법을 이용한 초대형 Open Caisson의 침하촉진에 대한 사례연구)

  • Jeong, Jin-Seob;Lee, Jong-Cheon;Kim, Hae-Woog;Kim, Tae-Hyung
    • Journal of Navigation and Port Research
    • /
    • v.33 no.3
    • /
    • pp.227-233
    • /
    • 2009
  • This experimental study has been carried out to investigate the reduction in side friction of open caisson using air-jet method. For this study, the large size caisson having air-pockets was used. This caisson was used as substructure of bridge. By using air-jet method, settlement time was decreased and even settlement was reached to the depth which conventional methods could not be. We found that the side resistance decreases to less then half the expected value. In addition to these merits, the air-jet method can result in self-weight settlement without applying additional load. Also the open caisson damage caused by blasting can be prevented with this method.

A Vulnerability Analysis of Intrusion Tolerance System using Self-healing Mechanism (자가치유 메커니즘을 활용한 침입감내시스템의 취약성 분석)

  • Park, Bum-Joo;Park, Kie-Jin;Kim, Sung-Soo
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.32 no.7
    • /
    • pp.333-340
    • /
    • 2005
  • One of the most important core technologies required for the design of the ITS (Intrusion Tolerance System) that performs continuously minimal essential services even when the network-based computer system is partially compromised because of the external or internal intrusions is the quantitative dependability analysis of the ITS. In this paper, we applied self-healing mechanism, the core technology of autonomic computing to secure the protection power of the ITS. We analyzed a state transition diagram of the ITS composed of a Primary server and a backup server utilizing two factors of self-healing mechanism (fault model and system response) and calculated the availability of ITS through simulation experiments and also performed studies on two cases of vulnerability attack.