• Title/Summary/Keyword: 손상허용

Search Result 182, Processing Time 0.027 seconds

A Real Scale Experimental Study for Evaluation of Permissible Shear Stresses on Vegetation Mats (식생매트 허용 소류력 평가를 위한 실규모 실험 연구)

  • Lee, Du Han;Kim, Dong-Hee;Kim, Myounghwan;Rhee, Dong Sop
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.6151-6158
    • /
    • 2012
  • By the activation of environment-friendly river works, application of vegetation mats is increasing, however, evaluation techniques for hydraulic stability of vegetation mats are not presented. This study is conducted to develop the objective test method for vegetation mats. Two kind of vegetation mats are tested by the real scale experiments, and hydraulic quantities are measured and analyzed to evaluate acting shear stresses. Roughness and shear stress are evaluated by 1 D non-uniform model. After each tests, changes in mat surfaces and sub-soil are evaluated, and from these evaluation, 3 types of mat surface damages and 2 types of sub-soil damages are presented. In the study, the case in which some damages in mat surface don't cause loss of sub-soil, is presented to be in the stable condition. Appling this stable condition and acting shear stresses, permissible shear stresses of vegetation mats are evaluated, and the results show that the reinforced mat with wire netting has more permissible shear stress.

Global Behavior Analyses of Structures with Damages Using a Modified Second Order Damage Tensor (수정된 2차손상텐서를 이용한 손상된 구조체의 거동해석)

  • 이상호;이형기;허용학
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.2
    • /
    • pp.257-270
    • /
    • 2000
  • The objective of this study is to develop a damage model based on damage mechanics that can be used to analyze the mechanical behavior of structures with defects and the global behavior of damaged structures. A modified second order damage tensor that can be applied to finite element analysis is used to reflect the effect of damage. The damage stress computed from the effective stress is considered as an additional loading term acting on nodes and can represent the effect of crack surface. The accuracy of the proposed algorithm is verified by comparing the analysis results with the experimental data from other studies and the analysis results based on transverse isotropic theory. The developed damage model is applied to the analyses of structures with cracks under linear elastic condition. The comparisons confirmed that the quantitative analysis of the structural behavior due to crack orientation and multiple sets of cracks is possible. Also, the damage caused by rock excavation and fault zone is analyzed. The results also showed that the developed model can effectively analyze the global behavior of damaged structures.

  • PDF

Development of a Fault-tolerant IoT System Based on the EVENODD Method (EVENODD 방법 기반 결함허용 사물인터넷 시스템 개발)

  • Woo, Min-Woo;Park, KeeHyun;An, Donghyeok
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.3
    • /
    • pp.263-272
    • /
    • 2017
  • The concept of Internet of Things (IoT) has been increasingly popular these days, and its areas of application have been broadened. However, if the data stored in an IoT system is damaged and cannot be recovered, our society would suffer considerable damages and chaos. Thus far, most of the studies on fault-tolerance have been focused on computer systems, and there has not been much research on fault-tolerance for IoT systems. In this study, therefore, a fault-tolerance method in IoT environments is proposed. In other words, based on the EVENODD method, one of the traditional fault-tolerance methods, a fault-tolerance storage and recovery method for the data stored in the IoT server is proposed, and the method is implemented on an oneM2M IoT system. The fault-tolerance method proposed in this paper consists of two phases - fault-tolerant data storage and recovery. In the fault-tolerant data storage phase, some F-T gateways are designated and fault-tolerant data are distributed in the F-T gateways' storage using the EVENODD method. In the fault-tolerant recovery phase, the IoT server initiates the recovery procedure after it receives fault-tolerant data from non-faulty F-T gateways. In other words, an EVENODD array is reconstructed and received data are merged to obtain the original data.

Damage Evaluation on the Concrete Using Acoustic Emission (음향방출(AE)을 이용한 콘크리트의 손상도 평가)

  • 이웅종;조홍동;이종열;한상훈
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.750-758
    • /
    • 2002
  • Concrete is deformed by load and subjected to micro damage under allowable deformation because of non-homogeneous property. When micro damage is accumulated, it is cracked and finally fractured. Characterization of AE can be demonstrated the micro damage which it is not discovered from visual observation, and it become known to an advantage that was clearly discriminated from the existing NDT method. This study was carried out the analysis and evaluation of concrete damage by acoustic emission technique. As a results of damage analysis, it was found out that the more concrete strength has increased, the more concrete has subjected to micro damage at lower stress ratio for chylinder specimen, and this is possible only AE method which could be described the brittle properties. Also it was revealed that the kaiser effect and felicity effect were existed in reinforced concrete bending specimens and it is found out that the onset of interface debonding between concrete and steel could be conformed in comparison with felicity ratio, AE activity and load history. From the results of this study, it was conformed that the deteriorative degree of reinforced concrete structure should be evaluated using felicity ratios.

The Behavior of Bearing Capacity for the Precast files (기성말뚝의 지지거동)

  • 박영호
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.107-116
    • /
    • 2000
  • Dynamic and static load tests are conducted in four construction sites by using steel pipe piles(SPP) and concrete piles to compare differences of load bearing mechanism. Steel pipe piles are instrumented with electric strain gages and are subject to dynamic load tests during driving. The damage of strain gages attached is checked simultaneously. Static load test is also conducted on the same piles after two to seven days' elapse. Then load-settlement behavior and shaft and/or tip resistances are measured. As a result, the allowable bearing capacity calculated by the Davisson's offset method of CAPWAP analysis shows 2~33% larger than that of static load test. The average value of allowable bearing capacity of static load test is closer to the allowable capacity obtained at the safety factor of 2.5 applied on ultimate bearing capacity than to the one obtained from the Davisson's offset method. The analysis of strain gage readings shows that unit skin friction increases with depth. Furthermore, the friction mobilized around the 1~2m above the pile tip considerably contributes to the total shaft resistance.

  • PDF

The Role of PPV and PVS in Controlled Blasting (제어발파의 설계 및 관리 과정에서의 PPV와 PVS의 역할)

  • Choi, Byung-Hee;Ryu, Chang-Ha;Hwang, Hyun-Joo;Choi, Yong-Kun;Ahn, Myung-Seog
    • Explosives and Blasting
    • /
    • v.26 no.2
    • /
    • pp.1-10
    • /
    • 2008
  • The safe level for residential structures has usually been prescribed as just 'particle velocity' in various specifications in Korea. It implies that there is a possibility of interpreting the 'particle velocity' as the PPV (Peak Particle Velocity), PVS (Peak Vector Sum), or something else, depending on the interpreter. As a result, there have always been some difficulties in both designing a controlled blasting and controling the blast-induced ground vibrations. This paper is intended to show what the role of the safe level criteria such as PPV or PVS is, and also how we should use the concept of the scaled distance equation in a controlled blast design. The paper also emphasizes the importance of the allowable level for various residential structures and its uses in each stage of the controlled blast design.

A Study of Relation Between Bending Radius and Pulling Tension (관로곡률반경과 케이블 포설장력에 관한 연구)

  • Lee, Hu-Young;Sun, Sang-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.418-419
    • /
    • 2008
  • 관로에 케이블을 포설할 때에는 최대포설장력(Maximum Pulling Tension Factors)과 허용측압(Sidewall Bearing Pressure)이 고려되어야 한다. 최대포설장력은 케이블의 무게와 관로의 마찰계수에 의해 계산이 되고 관로의 경간에 의해 변화하게 된다. 측압은 관로의 곡률반경, 포설장력, 케이블 무게 등과 직접 관련이 있다. 관로의 곡률반경은 현장에서 도로의 길이와 현의길이, 호의 높이 등을 측정하여 구하기도 하고 도면상에서 계산에 의해 구하기도 한다. 곡률반경과 포설장력, 측압의 관계성을 비교해 보면 포설장력은 곡률반경의 영향을 거의 받지 않지만 측압은 곡률반경의 영향을 크게 받는다. 허용측압이상의 측압이 굴곡부에서 관로와 케이블사이에 발생하면 관로와 케이블이 손상되기 때문에 관로 설계시에는 측압을 반드시 고려하여야 된다.

  • PDF

Low Temperature Structural Tests of a Composite Wing with Room Temperature-Curing Adhesive Bond (상온접합 본딩이 있는 복합재 날개의 저온 구조시험)

  • Ha, Jae Seok;Park, Chan Yik;Lee, Kee Bhum
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.10
    • /
    • pp.928-935
    • /
    • 2015
  • This paper presents low temperature structural tests of a UAV wing which has room temperature-curing adhesive bond. The wing structure is made of carbon fiber reinforced composites, and the skins are bonded to the inner structures (such as ribs and spars) using room temperature-curing adhesive bond. Also, to verify damage tolerance design of the wing structure, barely visible impact damages are intentionally created in the critical areas. The attachment fittings of the wing are fixed in a specially designed chamber which can simulate the low temperature environments of the operating altitudes. The test load is applied by hydraulic actuators which are placed outside the chamber. The structural tests consist of strain survey tests and a durability test for 1-life fatigue load spectrum. During the tests, strains of major parts are measured by strain gauges and FBG sensors. The change of the initial impact damages is also monitored using piezoelectric sensors. The 1-life damage tolerance of the composite structure is verified by the structural tests under the simulated environments.

Analysis of Long-Term Performance of Geogrids by Considering Interaction among Reduction Factors (감소계수 상호영향을 고려한 지오그리드의 장기성능 해석)

  • Jeon, Han-Yong;Kim, Yuan-Chun;Jang, Yeon-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.7
    • /
    • pp.55-65
    • /
    • 2012
  • Total reduction factor that is used when calculating allowable tensile strength of geogrids is made by multiplying the installation damage reduction factor ($RF_{ID}$), chemical degradation reduction factor ($RF_D$), and creep reduction factor ($RF_{CR}$) etc. In case of a model estimating allowable tensile strength considering reduction factor over the short-term tensile strength of geogrids, it has a limit of not considering interaction force between reduction factors. Junction strength comes to be reduced by installation damages or chemical degradation in the same way as tensile strength. Single junction test method cannot properly test damaged samples and shows large deviations as it does not consider scale effect. Besides, regarding calculating shear strength, no reasonable study on reduction factors was conducted yet. Therefore, in this study, reduction factors that may affect the long-term performance of geogrids were revaluated considering various conditions and accurate long-term allowable tensile strength was calculated considering interrelation between reduction factors. Creep results after installation damage and chemical resistance test showed lower value than calculated value according to GRI GG-4. After the installation damage test and the chemical resistance test, the reduction factor of junction strength was less than that of tensile strength. Shear strength before and after installation damage showed no change or increase.

Damage Monitoring for Wind Turbine Blade using Impedance Technique (임피던스 기법을 이용한 풍력 블레이드 손상 모니터링)

  • Huh, Yong-Hak;Kim, Jongil;Hong, Seonggu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.452-458
    • /
    • 2013
  • Impedance based monitoring technique was investigated to evaluate the damage occurring in wind turbine blade. In this study, PVDF film piezo sensors were patched on the 10 kW wind turbine blade, and impedance was measured over the frequency range of 1~200 MHz under fatigue loading. With applying fatigue loads on the blade, change in maximum deflection of the blade and local strain values could be obtained from the strain gages attached on the blade, and difference of the impedance signatures was also observed. From these data, it could be found that local damage or geometrical change in the blade structure happened. To quantitatively compare the impedance signature patterns, a statistical algorithm, scalar damage metric M was used. It was calculated from the impedance signatures considering fatigue loads and location of the sensors. The metric values were compared to correlate the metrics with damage in the blade.