• 제목/요약/키워드: 손목 관절

Search Result 79, Processing Time 0.033 seconds

Osteoid Osteoma in Wrist: A Case Report (수근부에 발생한 유골 골종: 증례 보고)

  • Lee, Chae-Chil;Kim, Sang Woo;Jung, Seung-Hyun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.20 no.2
    • /
    • pp.94-98
    • /
    • 2014
  • Osteoid osteoma can occur in all parts of the skeletal system. More than half occur in lower extremity and rare in wrist. Clinically pain is almost the only symptom worse at night and which is characterized by a rapid improvement by NSAID. We report the cases of osteoid osteoma which shows the characteristic symptoms and got a good results with appropriate imaging work up and surgical treatment.

Development of a parallel link typed wrist for robotic precision assembly (정밀조립을 위한 병렬다관절 구조를 가진 로봇손목기구의 개발)

  • 문창렬;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.281-286
    • /
    • 1993
  • In this paper, a parallel link typed wrist is developed for robotic precision assembly. The developed wrist can make the corrective motion required for compensating lateral and tilting errors. The mechanism of this wrist is one example of a motion simulator generating 6 DOF motion in space by 6 actuators connected in paralle. To make the wrist more compact, miniature DC motors containing reduction gears and servo system were used. The parallel link architecture enables a high positioning accuracy and high nominal load capacity. In this study, inverse kinematic problem is solved by using a Denavet-Hartenberg method and a simulational result about workspace of the proposed parallel mechanism is obtained.

  • PDF

2 D.O.F Control System using Wearable Electronic Device (착용가능한 2축 제어시스템)

  • Song, Hee-Bae;Park, Min-Young;Kim, Do-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1791-1792
    • /
    • 2007
  • 본 논문에서는 착용 가능한 모션 캡쳐 시스템을 설계하고 구현한다. 이 장치는 사람의 두 관절의 움직임을 각도로 표현하도록 디자인 되었다. 이를 위해 flex sensor를 사용했으며 센서의 히스테리시스를 확인하고 3차 다항식을 사용하여 근사적인 모델을 만들었다. 이 모델을 통해서 센서에서 가져온 전압을 각도로 표현하였으며 이 각도로 손목과 팔꿈치의 움직임을 시뮬레이션 했다. 시뮬레이션의 결과를 바탕으로 인간형 로봇과 통신을 통해서 움직임을 확인하였다.

  • PDF

A Case Report of Korean Medicine Rehabilitation Treatment after Sauve-Kapandji Procedure (Sauve-Kapandji 수술 후 한방재활치료에 대한 증례보고)

  • Cho, Eun-Byul;Geum, Ji-Hye;Baek, Dong-Gi;Lee, Jung-Han
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.14 no.1
    • /
    • pp.49-59
    • /
    • 2019
  • Objectives : The purpose of this study was to report the clinical progress of a patient exposed to a Sauve-Kapandji procedure after being diagnosed with dislocation of distal radioulnar joint and was treated using Korean medicine rehabilitation treatment. Methods : During the admission period, the patient was treated with acupuncture, cupping, herbal medicine, and Chuna therapy. The clinical progress was assessed by using range of motion(ROM), manual muscle test(MMT), numeric rating scale(NRS), and pain disability index(PDI). Results : After receiving the above treatments, the active ROM and motor grade of the elbow, wrist, and finger joints were improved; the NRS and PDI were decreased. Conclusions : Although this is a single case report, Korean medicine rehabilitation treatment, including Chuna manual therapy, might be an effective intervention for a patient after being exposed to a Sauve-Kapandji procedure.

Analysis of golf swing motion for specific properties of club shaft (클럽 샤프트(Club Shaft) 특성에 따른 골프 스윙(Golf Swing)동작 분석)

  • Kim, Sung-Il;Kim, Ky-Hyoung;Kim, Hyung-Soo;Lee, Hyun-Seob;Kim, Jin-Uk;Ahn, Chan-Gyu;Kim, Hee-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.17-32
    • /
    • 2002
  • The purpose of this study was to find the rational method to analyze golf swing with specific property of club shaft. Three subjects were filmed by two high speed digital cameras with 500 fps. The phase analyzed was downswing of each subject. The three-dimensional coordinates of the anatomical landmarks were obtained with motion analysis system Kwon3d 3.0 version and smoothed by lowpass digital filter with cutoff frequency 6Hz. From these data, kinematic and kinetic variables were calculated using Matlab(ver 5.0) The variables for this study were angular velocity and accelerations, which were calculated and following conclusions have been made : 1) Golf swing time of stiff club is faster than that of regular club. 2) In shoulder joint motion of swing with the stiff club, x-stiff showed mort rapid negative acceleration than that of regular club. 3) In regular club, the velocity of club head would be more effective velocity, which was increasing, than those of other clubs before impact. 4) In wrist joint motion of swing with stiff club, x-stiff club showed faster than regular club in the downswing and impact more rapid negative acceleration.

Kinematic Analysis of the Badminton Drive Motion (배드민턴 드라이브 동작의 운동학적 분석)

  • Wei, Lin-Lin;Oh, Cheong-Hwan;Jeong, Ik-Su;Park, Chan-Ho;Lee, Jeong-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.1
    • /
    • pp.77-85
    • /
    • 2009
  • This study is aimed at providing information on injury prevention and skill improvement by inducing the accurate movements in exercise as well as understanding the principles of badminton drive movements. Movement displacement of racket head showed the similar patterns among those surveyed but, it seemed that slight differences resulted from external factors such as height, length of brachial and forearm and individual trend of swing locus. Regarding upper joint angle per phase, the angles of shoulder joint, elbow joint and wrist joint were closely associated in taking drive movements and they supported the segment order theory that power was conveyed from proximal into distal. It was shown that angular velocity of upper joint became larger in follow through movement after impact among all those surveyed, which meant the importance of follow through in racket sports such as badminton. In conclusion, this follow through movement acts as an important factor in racket sports in terms of pose stability maintenance, pose correction of movements and injury prevention of joints. In summary, when swings are made according to segment order theory, efficient movements can be taken.

Optimal Wrist Design of Wrist-hollow Type 6-axis Articulated Robot using Genetic Algorithm (유전자 알고리즘을 이용한 손목 중공형 6축 수직다관절 로봇의 최적 손목 설계에 관한 연구)

  • Jo, Hyeon Min;Chung, Won Jee;Bae, Seung Min;Choi, Jong Kap;Kim, Dae Young;Ahn, Yeon Joo;Ahn, Hee Sung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.1
    • /
    • pp.109-115
    • /
    • 2019
  • In arc-welding applying to the present automobile part manufacturing process, a wrist-hollow type arc welding robot can shorten the welding cycle time, because feedability of a welding wire is not affected by a robot posture and thus facilitates high-quality arc welding, based on stable feeding with no entanglement. In this paper, we will propose the optimization of wrist design for a wrist-hollow type 6-Axis articulated robot. Specifically, we will perform the investigation on the optimized design of inner diameter of hollow arms (Axis 4 and Axis 6) and width of the upper arm by using the simulation of robot motion characteristics, using a Genetic Algorithm (i.e., GA). Our simulations are based on $SolidWorks^{(R)}$ for robot modeling, $MATLAB^{(R)}$ for GA optimization, and $RecurDyn^{(R)}$ for analyzing dynamic characteristics of a robot. Especially $RecurDyn^{(R)}$ is incorporated in the GA module of $MATLAB^{(R)}$ for the optimization process. The results of the simulations will be verified by using $RecurDyn^{(R)}$ to show that the driving torque of each axis of the writs-hollow 6-axis robot with the optimized wrist design should be smaller than the rated output torque of each joint servomotor. Our paper will be a guide for improving the wrist-hollow design by optimizing the wrist shape at a detail design stage when the driving torque of each joint for the wrist-hollow 6-axis robot (to being developed) is not matched with the servomotor specifications.

Evaluation of Distortion in Measuring the Stability of Distal Radio-ulnar Joint in Wrist PA-Grip View (Wrist PA-grip view에서 먼쪽노자관절의 안정성 정도 측정 시 왜곡도 평가)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.321-327
    • /
    • 2021
  • Wrist PA-grip view is used to diagnose triangular fibrocartilage complex (TFCC) tear because it can easily diagnose damage to the surrounding wrist ligaments. However, despite advances in radiology equipment, distortion of images due to geometric elements still has many limitations. In this paper, we propose a method that can minimize the distortions of images by analyzing the distortions occurring in the wrist PA-grip view. A source of image distance (SID) were set at 130 cm and 150 cm for comparison with 110 cm. Depending on the SID, the phantom of wrist was moved at 0, 2, 4, 6, 8, and 10 cm in the X-axis and Y-axis directions, respectively. For quantitative evaluation, the difference of distance between the radius and ulna was measured in picture archiving and communication system (PACS) system. As a qualitative evaluation, survey was conducted among 20 radiologic technologists who examined the Wrist PA-grip view. The Kruskal Wallis test was performed to compare the distortion according to the phantom movement in the X-axis and Y-axis directions based on the SID, and the Tukey test was performed as a post-test. In the quantitative evaluation results, the measured values obtained in the X-axis was not significantly different in all groups (p>0.05). The measured values obtained in the Y-axis was significantly different in the most groups (p<0.05). Therefore, to reduce distortion while maintaining image quality, we recommend what examine the SID at 150 cm than 110 cm.

A case study of radial nerve injury associated with humerus shaft fracture (상완골 간부 골절에 동반된 요골신경손상에 대한 치험 1례)

  • Lee, Jae-Eun;Lee, Jung-Min;Oh, Min-Seok
    • Journal of Haehwa Medicine
    • /
    • v.23 no.1
    • /
    • pp.157-166
    • /
    • 2014
  • Objective : The purpose of this study is to report the patient with radial nerve injury associated with humerus shaft fracture, who was improved by Korean medical treatments. Methods : The patient was treated by Jungsongouhyul pharmacopuncture, electrical stimulation therapy, physical therapy, and herbal medicine according to "Locating Yang brightness meridians" theory. Coding result, Numeric rating scale(NRS) and digital grip dynamometer were used to evaluate the wrist drop, numbness of fingers and grip power. Results : The patient showed the first sign of recovery after 6 weeks from onset. After 9 weeks from onset, the patient could perform delicate manual activity. Grip power showed noticeable improvement as well as coding result and NRS. Conclusions : The results suggest that providing Korean medical treatments according to "Locating Yang brightness meridians" theory is a good method for treating radial nerve injury associated with humerus shaft fracture. But further studies are required to concretely prove the effectiveness of this method for treating radial nerve injury associated with humerus fracture.

Effects of Stretching Extensor Carpi Radialis With Proximal Functional Massage on Pain and Strength in Patients With Lateral Epicondylalgia (팔꿉관절 가쪽위관절 통증 환자에서 근위방향 기능적 마사지를 이용한 노쪽 손목 폄근 신장운동이 통증과 근력에 미치는 효과)

  • Choung, Sung-Dae;Ha, Sung-Min;Kim, Su-Jung;Park, Kyue-Nam;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.19 no.1
    • /
    • pp.66-75
    • /
    • 2012
  • The purpose of this study was to identify the effects of two types of stretching extensor carpi radialis on the visual analog scale (VAS), pressure-pain thresholds (PPTs), grip strength (GS), and strength of wrist extensor (SWE) in patients with lateral epicondylalgia. Sixteen patients with lateral epicondylalgia were recruited for this study and randomly assigned to two groups; the conventional stretching group (CS) and the stretching of proximal functional massage group (PFM); the VAS, PPTs, GS, and SWE were measured before and after the intervention. Over a period of stretching exercises were performed for five minutes per day, five days per week. The paired t-test and Wilcoxon signed-rank test were used to determine the statistical differences in the VAS, PPTs, GS, and SWE (pre- and post-test). The Independent t-test and Mann-Whitney U test were used to compare the effects of stretching exercises between the CS and PFM groups. The results of this study demonstrated that in the PFM group, the PPTs, GS, and SWE significantly increased, and the VAS decreased (p<.05). In the CS group, the VAS and GS increased significantly after the three-week intervention (p<.05). Pain was decreased and strength (GS and SWE) was increased in the PFM group, compared to the CS group (p<.05). The findings of this study indicate that PFM technique can be applied for decreasing pain and increasing the GS and SWE in patients with lateral epicondylalgia.