• Title/Summary/Keyword: 속도보정

Search Result 659, Processing Time 0.029 seconds

External Gravity Field in the Korean Peninsula Area (한반도 지역에서의 상층중력장)

  • Jung, Ae Young;Choi, Kwang-Sun;Lee, Young-Cheol;Lee, Jung Mo
    • Economic and Environmental Geology
    • /
    • v.48 no.6
    • /
    • pp.451-465
    • /
    • 2015
  • The free-air anomalies are computed using a data set from various types of gravity measurements in the Korean Peninsula area. The gravity values extracted from the Earth Gravitational Model 2008 are used in the surrounding region. The upward continuation technique suggested by Dragomir is used in the computation of the external free-air anomalies at various altitudes. The integration radius 10 times the altitude is used in order to keep the accuracy of results and computational resources. The direct geodesic formula developed by Bowring is employed in integration. At the 1-km altitude, the free-air anomalies vary from -41.315 to 189.327 mgal with the standard deviation of 22.612 mgal. At the 3-km altitude, they vary from -36.478 to 156.209 mgal with the standard deviation of 20.641 mgal. At the 1,000-km altitude, they vary from 3.170 to 5.864 mgal with the standard deviation of 0.670 mgal. The predicted free-air anomalies at 3-km altitude are compared to the published free-air anomalies reduced from the airborne gravity measurements at the same altitude. The rms difference is 3.88 mgal. Considering the reported 2.21-mgal airborne gravity cross-over accuracy, this rms difference is not serious. Possible causes in the difference appear to be external free-air anomaly simulation errors in this work and/or the gravity reduction errors of the other. The external gravity field is predicted by adding the external free-air anomaly to the normal gravity computed using the closed form formula for the gravity above and below the surface of the ellipsoid. The predicted external gravity field in this work is expected to reasonably present the real external gravity field. This work seems to be the first structured research on the external free-air anomaly in the Korean Peninsula area, and the external gravity field can be used to improve the accuracy of the inertial navigation system.

Comparison of Weighted Needle Pinprick Sensory Thresholds and Sensory Nerve Conduction Studies in Diabetic Patients (당뇨병 환자에서의 가중침자 감각역치와 감각신경 전도검사와의 비교)

  • Ryoo, Jae-Kwan
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.1
    • /
    • pp.929-941
    • /
    • 1996
  • This study was conducted to determine the association between weighted needle pinprick sensory threshold(PPT) and sensory nerve conduction studies. The subjects were 53 healthy controls, 31 diabetic patients without peripheral neuropathic symptoms(DM) and 36 diabetic patients with peripheral neuropathic symptoms(DN). PPT was measured on the index and little fingers, bilaterally, as well as under the lateral malleolus, bilaterally. In electrophysiologic assessment the left and right median, ulnar and sural nerves were studied. Mean PPT in DN, DM and controls was high in turn on each sites tested. Age controlled PPT was significantly different among three groups on right little finger(p<0.05) and left malleolus(p<0.05), but on other sites, not statistically significantly different between DN and DM. The results were as follows: Sensory nerve conduction velocity and amplitude on each nerve tested were statistically significantly different among three groups(p<0.05). Correlation of PPT with sensory nerve conduction velocity and amplitude were statistically significant on each site and ranged from -0.4203(left malleolus) to -0.5649(right index finger) and from -0.3897(left index finger) to -0.6200(right index finger), respectively. When electrophysiological study is not feasible, measurement of PPT may be helpful for the assessment of peripheral sensory neurological function.

  • PDF

Comparison of Weighted Needle Pinprick Sensory Thresholds and Sensory Nerve Conduction Studies in Diabetic Patients (당뇨병(糖尿病) 환자(患者)에서의 가중침자(加重針刺) 감각역치와 감각신경(感覺神經) 전도검사(傳導檢査)와의 비교(比較))

  • Yoo, Jae-Kwan;Kim, Seong-Ah;Lee, Jong-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.899-910
    • /
    • 1995
  • This study was conducted to determine the correlation between weighted needle pinprick sensory threshold(PPT) and sensory nerve conduction tests. The subjects were 53 healthy controls, 31 diabetic patients without peripheral neuropathic symptoms(DM) and 36 diabetic patients with peripheral neuropathic symptoms(DN). PPT was measured on the index and little fingers, bilaterally, as well as under the lateral malleolus, bilaterally. In electrophysiologic assessment the left and right median, ulnar and sural nerves were studied. Each mean PPTs was high in order of controls, DM and DN. Age adjusted PPT was significantly different among three groups on right little finger(p<0.05) and left malleolus(p<0.05), but not significantly different between DN and DM on other sites. Each sensory nerve conduction velocity and amplitude was statistically significantly different among three groups(p<0.05). Correlations of PPT with sensory nerve conduction velocity and amplitude were statistically significant on each site and ranged from -0.4203(left malleolus) to -0.5649(right index finger) and from -0.3897(left index finger) to -0.6200(right index finger), respectively. When electrophysiological study is not feasible, measurement of PPT may be helpful for the assessment of peripheral sensory neurological function.

  • PDF

Determination of Freely Dissolved PAHs in Seawater around the Korean Peninsula Using High Speed Rotation-Type Passive Sampling Device (고속회전식 수동형 채집 장치를 이용한 한반도 주변해역에서의 자유용존상 PAHs 측정)

  • JANG, YU LEE;LEE, HYO JIN;JEONG, HAEJIN;JEONG, DA YEONG;KIM, NA YEONG;KIM, GI BEUM
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.1
    • /
    • pp.37-48
    • /
    • 2021
  • A new high speed rotation type-passive sampling device (HSR-PSD), which can rotate seawater at high speed and absorb easily and quickly the freely dissolved hydrophobic organic contaminants from seawater, was developed and then applied around the Korean Peninsula. Freely dissolved concentrations (Cfree) of polycyclic aromatic hydrocarbons (PAHs) were determined using the HSR-PSD with low density polyethylene (LDPE) sheets as a passive sampler. Furthermore, dissolved concentrations (Cdissolved) of PAHs in seawater were also obtained from high volume water sampling as a conventional method to account for actual bioavailability. When the LDPE sheets were rotated in the HSR-PSD at 900 rpm, PAHs with log KOW 3.4 ~ 5.2 were equilibrated between the LDPE and water in 5 hours. Although the high molecular weight PAHs with log KOW 5.6 ~ 6.8 was expected to be 2 to 30 days to reach the equilibrium, the Cfree of the PAHs at equilibrium could be corrected using performance reference compounds in 5 hours. Meanwhile, the total Cfree of PAHs were from 0.32 to 1.2 ng/L, which were higher than reported values in other oceans, but lower than in coastal water such as estuary, harbor, or shore. A bioavailability from the detected PAHs was highest at the sampling line near the dumping site of the Yellow Sea. Predicted residual concentrations in biota were relatively higher in offshore including the dumping site than in coastal regions.

Evaluation of Antenna Pattern Measurement of HF Radar using Drone (드론을 활용한 고주파 레이다의 안테나 패턴 측정(APM) 가능성 검토)

  • Dawoon Jung;Jae Yeob Kim;Kyu-Min Song
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.35 no.6
    • /
    • pp.109-120
    • /
    • 2023
  • The High-Frequency Radar (HFR) is an equipment designed to measure real-time surface ocean currents in broad maritime areas.It emits radio waves at a specific frequency (HF) towards the sea surface and analyzes the backscattered waves to measure surface current vectors (Crombie, 1955; Barrick, 1972).The Seasonde HF Radar from Codar, utilized in this study, determines the speed and location of radial currents by analyzing the Bragg peak intensity of transmitted and received waves from an omnidirectional antenna and employing the Multiple Signal Classification (MUSIC) algorithm. The generated currents are initially considered ideal patterns without taking into account the characteristics of the observed electromagnetic wave propagation environment. To correct this, Antenna Pattern Measurement (APM) is performed, measuring the strength of signals at various positions received by the antenna and calculating the corrected measured vector to radial currents.The APM principle involves modifying the position and phase information of the currents based on the measured signal strength at each location. Typically, experiments are conducted by installing an antenna on a ship (Kim et al., 2022). However, using a ship introduces various environmental constraints, such as weather conditions and maritime situations. To reduce dependence on maritime conditions and enhance economic efficiency, this study explores the possibility of using unmanned aerial vehicles (drones) for APM. The research conducted APM experiments using a high-frequency radar installed at Dangsa Lighthouse in Dangsa-ri, Wando County, Jeollanam-do. The study compared and analyzed the results of APM experiments using ships and drones, utilizing the calculated radial currents and surface current fields obtained from each experiment.

Behavior of Truss Railway Bridge Using Periodic Static and Dynamic Load Tests (주행 열차의 정적 및 동적 재하시험 계측 데이터를 이용한 트러스 철도 교량의 주기적 거동 분석)

  • Jin-Mo Kim;Geonwoo Kim;Si-Hyeong Kim;Dohyeong Kim;Dookie Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.120-129
    • /
    • 2023
  • To evaluate the vertical loads on railway bridges, conventional load tests are typically conducted. However, these tests often entail significant costs and procedural challenges. Railway conditions involve nearly identical load profiles due to standardized rail systems, which may appear straightforward in terms of load conditions. Nevertheless, this study aims to validate load tests conducted under operational train conditions by comparing the results with those obtained from conventional load tests. Additionally, static and dynamic structural behaviors are extracted from the measurement data for evaluation. To ensure the reliability of load testing, this research demonstrates feasibility through comparisons of existing measurement data with sensor attachment locations, train speeds, responses between different rail lines, tendency analysis, selection of impact coefficients, and analysis of natural frequencies. This study applies to the Dongho Railway Bridge and verifies the applicability of the proposed method. Ten operational trains and 44 sensors were deployed on the bridge to measure deformations and deflections during load test intervals, which were then compared with theoretical values. The analysis results indicate good symmetry and overlap of loads, as well as a favorable comparison between static and dynamic load test results. The maximum measured impact coefficient (0.092) was found to be lower than the theoretical impact coefficient (0.327), and the impact influence from live loads was deemed acceptable. The measured natural frequencies approximated the theoretical values, with an average of 2.393Hz compared to the calculated value of 2.415Hz. Based on these results, this paper demonstrates that for evaluating vertical loads, it is possible to measure deformations and deflections of truss railway bridges through load tests under operational train conditions without traffic control, enabling the calculation of response factors for stress adjustments.

Image quality and usefulness evaluaton of 3D-CBCT and Gated-CBCT according to baseline changes for SBRT of Lung Cancer (폐암 환자의 정위체부방사선치료 시 기준선 변화에 따른 3D-CBCT(Cone Beam Computed-Tomography)와 Gated-CBCT의 영상 품질 및 유용성 평가)

  • Han Kuk Hee;Shin Chung Hun;Lee Chung Hwan;Yoo Soon Mi;Park Ja Ram;Kim Jin Su;Yun In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.41-51
    • /
    • 2023
  • Purpose: This study compares and analyzes the image quality of 3D-CBCT(Cone Beam Computed-Tomography) and Gated CBCT according to baseline changes during SBRT(Stereotactic Body RadioTherapy) in lung cancer patients to find a useful CBCT method for correcting movement due to breathing Materials and methods : Insert a solid tumor material with a diameter of 3 cm into the QUASARTM phantom. 4-Dimentional Computed-Tomography(4DCT) images were taken with a speed of the phantom at period 3 sec and a maximum amplitude of 20 mm. Using the contouring menu of the computerized treatment planning system EclipseTM Gross Tumor Volume was outlined on solid tumor material. Set-up the same as when acquiring a 4DCT image using Truebeam STxTM, breathing patterns with baseline changes of 1 mm, 3 mm, and 5 mm were input into the phantom to obtain 3D-CBCT (Spotlight, Full) and Gated-CBCT (Spotlight, Full) images five times repeatedly. The acquired images were compared with the Signal-to-Noise Ratio(SNR), Contrast-to-Noise Ratio(CNR), Tumor Volume Length, and Motion Blurring Ratio(MBR) based on the 4DCT image. Results: The average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Spotlight Gated CBCT images were 13.30±0.10%, 7.78±0.16%, 3.55±0.17%, 1.18±0.06%. As a result, Spotlight Gated-CBCT images according to baseline change showed better values than Spotligtht 3D-CBCT images. Also, the average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Full Gated CBCT images were 12.80±0.11%, 7.60±0.11%, 3.54±0.16%, 1.18±0.05%. As a result Full GatedCBCT images according to baseline change showed better values than Full 3D-CBCT images. Conclusion : Compared to 3D-CBCT images, Gated-CBCT images had better image quality according to the baseline change, and the effect of Motion Blurring Artifacts caused by breathing was small. Therefore, it is considered useful to image guided using Gated-CBCT when a baseline change occurs due to difficulty in regular breathing during SBRT that exposes high doses in a short period of time

  • PDF

Studies on the Biological Effects of Chemosterilant, Hempa, on the Rice Weevil (Sitophilus oryzae 1.) and Transmission of Sterility (화학적 불임유기물질 Hempa가 쌀바구미(Sitophilus oryzae L.)에 미치는 생물학적 영향 및 불임성의 전달에 관한 연구)

  • Shim Jai Wook
    • Korean journal of applied entomology
    • /
    • v.12 no.1
    • /
    • pp.1-21
    • /
    • 1973
  • Some experiments were conducted to investigate the effects of the chemosterilant, hempa, on the biology of the rice weevil, Sitophilus oryzae L., and the transmission of the lethal factors in the progeny. One to three days old adult males were fed on the wheat grains treated with concentrations of 0.0625, 0.125, 0.25, and $0.5\%$ of hempa water solution. The effects of the treatment on the mortality, longevity, and the performance of oviposition were examined for the Pl generation, and the hatchability and mortality in the postembryonic development were also tested in the $F_1,\;F_2,\;BC_1,\;F_3,\;and\;BC_2$ generations to analyze the inheritance of the lethal factors. The results obtained were summarized as follows. (1) The average longevity of the treated males were ranged from 26.6 to 30.4 days, and indicated no statistical differences. (2) The mortality of the treated males were ranged between $3.3\%\;and\;13.3\%$ and showed no statistical significance. (3) The overall mean number of eggs laid by a female mated to a treated male with concentrations of 0.0625, 0.125, 0.26 and $0.5\%$ were 3.78, 4.05, 3.75 and 3.61 for the respective treatments, and they were not differ significantly from those of control which were 3.60 per female per 3 day period. The unmated female laid 1.91 in the same period, and significantly differ from those in other experimental groups. (4) The overall mean hatchability of the eggs laid by the females mated with males that had been treated with various concentrations of hempa were 86.82, 64.77, 53.47, 40.33 and $24.78\%$ for the respective concentrations of 0, 0.0625, 0.125, 0.25 and $0.5\%$. The hatchability decreased with the increasing concentrations. (5) The minimum hatchabilities were obtained from the eggs laid in the period of 10-12 days after treatment, then the hatchability increased showing some recovery. The recovery seemed to be very much delayed for the males which had been treated with the greater concentrations. Such a difference in hatchability might be related with the sensitivity of the developmental stages of the sperms, and broader spectrum in the stages and severer effects seemed to be associated with the increased concentrations. (6) The overall mean of larval mortality in the $F_l$ generation were 6.55, 17.89, 27.40, 35.42 and $52.17\%$ for the respective concentrations of 0,0.0625, 0.125,0.25 and $0.5\%$. And there was a tendency to increase in the mortality with the increase of concentrations. (7) The correlation coefficients between per cent sterile eggs and larval mortality for the experimental plots of 0.125, 0.25 and $0.5\%$ treatments showed r=+0.83 and +0.85, respectively, and it seemed to be close correlation between the lethal effects on the embryonic and post-embryonic developments. (8) Since the $SC_{50}$ of the sterile eggs was $0.133\%$ and $SC_{50}$ of the larval mortality was $0.565\%$, it was considered that tile lethal factors expressed more in the egg stages than the larval stages. (9) The ratio of female to male in the $F_l$ adults showed 100 : 125, 100 : 108 and 100 : 124 for the plots of 0.125, 0.25 and $0.5\%$ treatments, respectively. And it n·as considered that the sex ratio distortions might occur with the higher concentrations. (10) When the F, males originated 1.on the eggs had been laid by p, in the period of 16-18 days after treatment, were crossed to normal females $(BC_1)$ and made sib matings $(F_2)$, the per cent sterile eggs of the $BC_1$ generation were 13.88 and $33.04\%$ , and were 31.01 and $38.73\%$ for the $F_2$generation with the plots of 0.0625 and $0.125\%$ treatment, respectively. And these seemed to be a results of the $F_1$ individuals are carrying some chromosomal aberrations (11) The larval mortality was the highest in the $F_2$ plot and followed the female backcross plot, and the least in the male backcrosses. (12) The proportions of 1st and 2nd instar larvae among the larval development at tile 17th day after oviposition were 10.98, 27.26, 32.98 and $15.73\%$ in the normal female $\times$ normal male, $F_1$ female$\times$normal male, normal $female \;\times F_1$ male and $female \;\times F_1$ male plots, respectively. It was considered that the larval development might be delayed by the treatment in the 2nd generation. (13) Per cent larval mortality and sterile eggs were greater in the $F_2$ sib mating plots $(F_3)$ than both of $F_2$ backcrosses. Therefore, it seemed that some of the recessive lethal mutations might affect in the further generations. (14) The sterility, induced by the treatment of chemosterilant, hempa, was considered as the result of the dominant lethal mutations due to chromosomal aberrations such as translocation and/or deletion. The effects of these lethal factors seemed to be inherited tip to 3rd generation after treatment.

  • PDF

Optimum Radiotherapy Schedule for Uterine Cervical Cancer based-on the Detailed Information of Dose Fractionation and Radiotherapy Technique (처방선량 및 치료기법별 치료성적 분석 결과에 기반한 자궁경부암 환자의 최적 방사선치료 스케줄)

  • Cho, Jae-Ho;Kim, Hyun-Chang;Suh, Chang-Ok;Lee, Chang-Geol;Keum, Ki-Chang;Cho, Nam-Hoon;Lee, Ik-Jae;Shim, Su-Jung;Suh, Yang-Kwon;Seong, Jinsil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.143-156
    • /
    • 2005
  • Background: The best dose-fractionation regimen of the definitive radiotherapy for cervix cancer remains to be clearly determined. It seems to be partially attributed to the complexity of the affecting factors and the lack of detailed information on external and intra-cavitary fractionation. To find optimal practice guidelines, our experiences of the combination of external beam radiotherapy (EBRT) and high-dose-rate intracavitary brachytherapy (HDR-ICBT) were reviewed with detailed information of the various treatment parameters obtained from a large cohort of women treated homogeneously at a single institute. Materials and Methods: The subjects were 743 cervical cancer patients (Stage IB 198, IIA 77, IIB 364, IIIA 7, IIIB 89 and IVA 8) treated by radiotherapy alone, between 1990 and 1996. A total external beam radiotherapy (EBRT) dose of $23.4\~59.4$ Gy (Median 45.0) was delivered to the whole pelvis. High-dose-rate intracavitary brachytherapy (HDR-IBT) was also peformed using various fractionation schemes. A Midline block (MLB) was initiated after the delivery of $14.4\~43.2$ Gy (Median 36.0) of EBRT in 495 patients, while In the other 248 patients EBRT could not be used due to slow tumor regression or the huge initial bulk of tumor. The point A, actual bladder & rectal doses were individually assessed in all patients. The biologically effective dose (BED) to the tumor ($\alpha/\beta$=10) and late-responding tissues ($\alpha/\beta$=3) for both EBRT and HDR-ICBT were calculated. The total BED values to point A, the actual bladder and rectal reference points were the summation of the EBRT and HDR-ICBT. In addition to all the details on dose-fractionation, the other factors (i.e. the overall treatment time, physicians preference) that can affect the schedule of the definitive radiotherapy were also thoroughly analyzed. The association between MD-BED $Gy_3$ and the risk of complication was assessed using serial multiple logistic regression models. The associations between R-BED $Gy_3$ and rectal complications and between V-BED $Gy_3$ and bladder complications were assessed using multiple logistic regression models after adjustment for age, stage, tumor size and treatment duration. Serial Coxs proportional hazard regression models were used to estimate the relative risks of recurrence due to MD-BED $Gy_{10}$, and the treatment duration. Results: The overall complication rate for RTOG Grades $1\~4$ toxicities was $33.1\%$. The 5-year actuarial pelvic control rate for ail 743 patients was $83\%$. The midline cumulative BED dose, which is the sum of external midline BED and HDR-ICBT point A BED, ranged from 62.0 to 121.9 $Gy_{10}$ (median 93.0) for tumors and from 93.6 to 187.3 $Gy_3$ (median 137.6) for late responding tissues. The median cumulative values of actual rectal (R-BED $Gy_3$) and bladder Point BED (V-BED $Gy_3$) were 118.7 $Gy_3$ (range $48.8\~265.2$) and 126.1 $Gy_3$ (range: $54.9\~267.5$), respectively. MD-BED $Gy_3$ showed a good correlation with rectal (p=0.003), but not with bladder complications (p=0.095). R-BED $Gy_3$ had a very strong association (p=<0.0001), and was more predictive of rectal complications than A-BED $Gy_3$. B-BED $Gy_3$ also showed significance in the prediction of bladder complications in a trend test (p=0.0298). No statistically significant dose-response relationship for pelvic control was observed. The Sandwich and Continuous techniques, which differ according to when the ICR was inserted during the EBRT and due to the physicians preference, showed no differences in the local control and complication rates; there were also no differences in the 3 vs. 5 Gy fraction size of HDR-ICBT. Conclusion: The main reasons optimal dose-fractionation guidelines are not easily established is due to the absence of a dose-response relationship for tumor control as a result of the high-dose gradient of HDR-ICBT, individual differences In tumor responses to radiation therapy and the complexity of affecting factors. Therefore, in our opinion, there is a necessity for individualized tailored therapy, along with general guidelines, in the definitive radiation treatment for cervix cancer. This study also demonstrated the strong predictive value of actual rectal and bladder reference dosing therefore, vaginal gauze packing might be very Important. To maintain the BED dose to less than the threshold resulting in complication, early midline shielding, the HDR-ICBT total dose and fractional dose reduction should be considered.