• Title/Summary/Keyword: 속눈썹

Search Result 27, Processing Time 0.017 seconds

The Reconstruction of the Extensive Inferior Blow-out Fracture Through Endoscopic Transnasal and Subciliary Approaches (광범위한 안와하벽골절에서 속눈썹밑 절개 및 비강 내 내시경적 접근을 동시에 사용한 재건술)

  • Cho, Soo-Jong;Oh, Heung-Chan;Nam, Su-Bong;Kang, Cheol-Uk;Bae, Yong-Chan
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.2
    • /
    • pp.86-90
    • /
    • 2009
  • Purpose: Inferior blow-out fracture is the common facial fracture. Unsatisfactory functional and aesthetic outcomes are frequent when it is treated inappropriately. If fractures are extended and reach the posterior end of orbital floor, enophthalmos frequently followed as complication. The purpose of this study was to evaluate reduction technique of extensive inferior blow-out fracture with ballooning of foley catheter through endoscopic transnasal approach and implantation of $Medpor^{(R)}$ through subciliary approach. Methods: A retrospective study was performed on 14 patients with extensive inferior blow-out fracture who underwent ballooning of foley catheter through endoscopic transnasal approach with implantation of $Medpor^{(R)}$ through subciliary approach. Patients were operated from May 2005 to November 2007. Data for 14 patients were acquired from patient's charts. Preoperative and postoperative data for enophthalmos, diplopia, limitation of extraocular motion were reviewed. Preoperative and postoperative CT scan were also checked. The patients were followed up from 4 to 18 months. Results: The enophthalmos was corrected in all patients. Among 7 patients with diplopia preoperatively, diplopia was resolved in three patients postoperatively. The diplopia persisted in four patients and two of them also had limitation of extraocular motion postoperatively. The limitation of extraocular motion occurred in seven patients preoperatively. But five patients recovered after operation immediately. These symptoms were resolved about three months after the operation. Conclusion: The ballooning of foley catheter through endoscopic transnasal approach with implantation of $Medpor^{(R)}$ through subciliary approach can be considered one of the appropriate technique for extensive inferior blowout fracture.

A Comparative Study of The Movie Farewell My Concubine and Miss Korea Elected in 1989 in The Makeup Image (메이크업 이미지에 나타난 영화 패왕별희(覇王別姬)와 1989년 미스코리아 당선자의 비교에 관한 연구)

  • Park, Jang-Soon
    • Journal of Industrial Convergence
    • /
    • v.18 no.3
    • /
    • pp.27-34
    • /
    • 2020
  • For modern people living in the era of the 4th Industrial Revolution, appearance management and consumption behavior are very important factors not only in personal values but also in human relationships. It is used as an important means of competitiveness with skin beauty and fashion. It is used as an important means. Therefore, we compared and analyzed professionally from the aesthetic point of view about the makeup of the eyebrows, eyes, eye line, cheeks, lip make-up, and skin tone of Woohee, who appeared in the movie and Miss Korea in 1989. As a result of the study, other aspects were analyzed in the common denominator of a somewhat exaggerated makeup technique. Accordingly, through this study, it is possible to explore multiple angles for developing novel makeup patterns and items, and at the same time, it will help to establish a foundation for makeup beauty education. In addition, this study intends to contribute to the practical development with competitiveness by building a more aggressive marketing strategy in the makeup market.

A new record of Plaintive Cuckoo (Cacomantis merulinus) in Korea (우는뻐꾸기(가칭: Cacomantis merulinus)의 국내 첫 기록)

  • Kim, Hankyu;Kim, Hwa-Jung;Park, Jin-young
    • Korean Journal of Ornithology
    • /
    • v.25 no.2
    • /
    • pp.133-135
    • /
    • 2018
  • Plaintive Cuckoo (Cacomantis merulinus) is a small cuckoo species in Family Cuculidae that is mainly distributed in the Oriental Region. On May 1. 2016, one juvenile Plaintive Cuckoo was found at Somaemuldo Island, Korea ($34^{\circ}37^{\prime}38.73^{{\prime}{\prime}}N$ $128^{\circ}33^{\prime}0.44^{{\prime}{\prime}}E$). The bird was identified as C. merulinus by its morphological traits, especially primary projection, the shape of bars on tertials, and pale supercilium. These characteristics were distinctive from other similar small cuckoos in genus Cacomantis and Cuculus, during the field observation and examination of photographs. This record is the first of this species in Korea, and the northernmost record of this species.

The Physical Properties and Performance of Products for Eyelash Monofilaments (속눈썹용 원사의 물리적 성질 및 제품성능)

  • Son, Eun Jong;Ahn, Jae Sang;Yoon, Hye Jun;Shin, Hee Young
    • Textile Coloration and Finishing
    • /
    • v.34 no.4
    • /
    • pp.272-283
    • /
    • 2022
  • In this study, the flat-section monofilaments of PBT for artificial eyelashes was developed, and the physical properties of the circular cross-section of artificial eyelashes were compared and observed, and the main performance of the artificial eyelash prototype was observed through processing for artificial eyelashes. In addition, a satisfaction survey of the prototype was conducted through a survey of consumers and artificial eyelash operators. It was found that the bending stiffness value of the monofilaments increased significantly as the thickness increased. As a result of measuring the bending properties of the flat-section PBT monofilaments, the bending stiffness was significantly lower than that of the circular-section PBT specimens of the same thickness. The deformed cross-section PBT monofilaments with flat cross sections developed in this study showed a light weight factor of less than 50% compared to the existing circular cross-section PBT ones. The adhesive strength of the developed PBT artificial specimens was greater than that of the existing circular cross-section yarn. It was also observed that the curl stability over time was excellent. As a result of the consumer survey, it was possible to obtain more than 85% of positive answers in the case of consumer subjects, and it was possible to investigate that the satisfaction of the operator subjects was more than 80% compared to the existing round-section eyelashes.

Mobile Iris Recognition System Based on the Near Infrared Light Illuminator of Long Wavelength and Band Pass Filter and Performance Evaluations (장파장 근적외선 조명 및 밴드 패스 필터 기반 이동형 홍채 인식 시스템 및 성능 평가)

  • Cho, So-Ra;Nam, Gi-Pyo;Jeong, Dae-Sik;Shin, Kwang-Yong;Park, Kang-Ryoung;Shin, Jae-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.9
    • /
    • pp.1125-1137
    • /
    • 2011
  • Recently, there have been previous research about the iris recognition in mobile device to increase portability, whose accuracy is affected by the quality of iris image. Iris image is affected by illumination environment during the image acquisition. The existing system has high accuracy in indoor environment. However the accuracy is degraded in outdoor environment, because the gray levels of iris patterns in image are changed, and ghost and eyelash shading regions are produced by the sunlight of various wavelengths into iris region. To overcome these problems, we propose new mobile iris camera system which uses the near-infrared (NIR) light illuminator of 850 nm and band pass filter (BPF) of 850 nm. To measure the performance of the proposed system, we compared it to the existing one with the iris images captured in indoor and outdoor sunlight environments in terms of the equal error rates (EER) based on false acceptance rate (FAR) and false rejection rate (FRR). The experimental result showed that the proposed system had the lower EERs than those of previous system by 0.96% (with frontal light in indoors), 4.94% (with frontal light in outdoor), 9.24% (with side light in outdoor), and 7% (with back light in outdoor), respectively.

A Study on the Restoration of a Low-Resoltuion Iris Image into a High-Resolution One Based on Multiple Multi-Layered Perceptrons (다중 다층 퍼셉트론을 이용한 저해상도 홍채 영상의 고해상도 복원 연구)

  • Shin, Kwang-Yong;Kang, Byung-Jun;Park, Kang-Ryoung;Shin, Jae-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.3
    • /
    • pp.438-456
    • /
    • 2010
  • Iris recognition uses a unique iris pattern of user to identify person. In order to enhance the performance of iris recognition, it is reported that the diameter of iris region should be greater than 200 pixels in the captured iris image. So, the previous iris system used zoom lens camera, which can increase the size and cost of system. To overcome these problems, we propose a new method of enhancing the accuracy of iris recognition on low-resolution iris images which are captured without a zoom lens. This research is novel in the following two ways compared to previous works. First, this research is the first one to analyze the performance degradation of iris recognition according to the decrease of the image resolution by excluding other factors such as image blurring and the occlusion of eyelid and eyelash. Second, in order to restore a high-resolution iris image from single low-resolution one, we propose a new method based on multiple multi-layered perceptrons (MLPs) which are trained according to the edge direction of iris patterns. From that, the accuracy of iris recognition with the restored images was much enhanced. Experimental results showed that when the iris images down-sampled by 6% compared to the original image were restored into the high resolution ones by using the proposed method, the EER of iris recognition was reduced as much as 0.133% (1.485% - 1.352%) in comparison with that by using bi-linear interpolation

Eyelid Detection Algorithm Based on Parabolic Hough Transform for Iris Recognition (홍채 인식을 위한 포물 허프 변환 기반 눈꺼풀 영역 검출 알고리즘)

  • Jang, Young-Kyoon;Kang, Byung-Jun;Park, Kang-Ryoung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.1
    • /
    • pp.94-104
    • /
    • 2007
  • Iris recognition is biometric technology which uses a unique iris pattern of user in order to identify person. In the captured iris image by conventional iris recognition camera, it is often the case with eyelid occlusion, which covers iris information. The eyelids are unnecessary information that causes bad recognition performance, so this paper proposes robust algorithm in order to detect eyelid. This research has following three advantages compared to previous works. First, we remove the detected eyelash and specular reflection by linear interpolation method because they act as noise factors when locating eyelid. Second, we detect the candidate points of eyelid by using mask in limited eyelid searching area, which is determined by searching the cross position of eyelid and the outer boundary of iris. And our proposed algorithm detects eyelid by using parabolic hough transform based on the detected candidate points. Third, there have been many researches to detect eyelid, but they did not consider the rotation of eyelid in an iris image. Whereas, we consider the rotation factor in parabolic hough transform to overcome such problem. We tested our algorithm with CASIA Database. As the experimental results, the detection accuracy were 90.82% and 96.47% in case of detecting upper and lower eyelid, respectively.