To safeguard the accommodation spaces on cargo ships from fire, structural fire protection provisions introduced by SOLAS and these measures retard the propagation of flames and smoke. SOLAS also specifies provisions for fire fighting drills. These provisions are a combination of regulations regarding structure and equipment and those dealing with the human element for the fire protection and effective responses in the event of fire. Requirements related to the human element play a supporting role to the requirements for structure and equipment because the present accommodation structure and equipment are insufficient for extinguishing a fire, therefore, fire-extinguishing activity performed by crew members is essential. To reduce human error and ensure effective fire fighting, it is necessary to install a fire-fighting system and improve the fire fighting process. The fundamental concept of fire fighting exercises is to commence fire fighting before the fire grows too big to extinguish. It is essential to relocate the storage place of fire fighting equipment to expedite the fire-fighting exercise. This study was carried out to reduce human risk for this purpose, the fire control station was relocated to a site that could be accessed from the open deck. Further, two sets of a fire fighter's outfit were stored at the same site. This relocation eliminated the risk of the crew reentering to operate the fire fighting system in the fire control station and allowed the crew to pick up the fire fighters' outfits quickly in the event of a fire. In addition, it was proposed that the IIC method be made mandatory. This method is combination of automatic fire detection system and sprinkler system which can reduce the risk of the fire fighting exercises for the crew and to suppress fire in the initial stage. This study was carried out to provide a foundation to the possible amendment of the relevant SOLAS regulations and national legislation.
화재 발생에 따른 화재조사 시 배전반이나 분전반의 완전 소락에 따른 전기화재 원인규명의 기본적이고도 중요한 증거 소멸로 원인불명 율이 점차 높아가고 있는 실정이다. 공장이나 창고에서 전기화재를 가장한 수 배전반 화재를 시도할 경우 그 증거를 찾기 어렵다. 또한, 수 배전반이 위치한 곳에 사람이 상주하지 않는 곳이 많으며 초기 소화가 원활히 이루어지지 않을 경우 막대한 재산 피해와 통신의 대혼란을 가져올 소지가 다분히 존재하고 있다. 따라서, 수 배전반 및 분전반의 화재로부터 보호하기 위해서는 신뢰성과 안전성이 확보된 자동소화 시스템의 도입이 필요하다.
Proceedings of the Korean Institute of Industrial Safety Conference
/
1997.11a
/
pp.37-41
/
1997
스프링클러 소화설비는 화재가 발생하였을 때 자동적으로 감열, 작동하여 초기화재 진압을 목적으로 하는 소화설비로서 소화특성은 화재발생으로부터 소화가 시작되는 화재감지특성과 화재제어 및 진압에 대한 방사특성1) 으로 FRS2) 3)와 FMRC4)에서는 열응답의 민감도를 나타내는 반응시간지수(RTI)의 측정방법과 이론을 제시하였다. 반응시간지수는 스프링클러헤드의 작동에 필요한 충분한 열을 주위로부터 얼마나 빠른 시간내에 흡수 할 수 있는지를 나타내는 특성치로서 가열공기의 온도 및 속도에 의해 결정되며 값이 적을수록 헤드가 조기에 작동하게 된다. (중략)
Proceedings of the Korea Institute of Fire Science and Engineering Conference
/
2010.10a
/
pp.99-102
/
2010
가스계 소화설비는 소화약제의 특성상 방호구역내의 누설면적에 민감하게 영향을 받고, 누설면적이 너무 크면 제대로 된 소화성능을 발휘 할 수 없기 때문에 설계 및 시공, 그리고 설치 후 성능 검증 등에 주의가 필요하다. 이전 가스계 소화설비의 성능확인방법으로 종래에는 소화약제 전량을 직접방출하거나 극히 일부 저장용기의 소화약제만을 방출시키는 소위 간이시험을 실시하는 것이 보편적이었으나, 방출시험은 고비용, 일회성 및 시험절차의 난이성, 그리고 환경오염으로 인해 실제 방출시험을 통한 설비의 신뢰성 확인이 어려운 실정이다. 이러한 상황을 감안하여 가스계 소화설비의 성능검증을 위해 Door Fan Test를 활용하는 방안에 대하여 알아보고자 한다.
Journal of the Korea Organic Resources Recycling Association
/
v.20
no.1
/
pp.61-70
/
2012
Feasibility of co-digestion was investigated by a series of anaerobic batch experiments using sewage sludge, swine waste, and food waste leachate as substrates. The organic solid wastes were collected from M city, where the daily productions of sewage sludge, swine waste, and food waste leachate were 178 ton/d, 150 ton/d, and 8 ton/d, respectively. Both swine waste and food waste leachate showed superior methane yields, methane productivities, and organic pollutant removal efficiencies compared to sewage sludge. Co-digestion of the total amounts of organic solid wastes would enhance methane production by 5.60 times $(530\;m^{3}\;CH_{4}/d\;{\rightarrow}\;2,968\;m^{3}\;CH_{4}/d)$. However, it also increase the amount of digestate by 1.88 times with 3.79 to 4.92 times higher pollutants (chemical oxygen demands total nitrogen, and total phosphorus) loading rates. Co-digestion of organic solid wastes is a valid strategy to enhance the performance of an anaerobic sludge digester and the energy independence of a wastewater treatment plant. Anyhow,the increment of digestate with higher pollutant loading would need a careful counterplan in the operation of the main stream of the treatment plant.
Proceedings of the Korean Aquaculture Society Conference
/
2003.10a
/
pp.22-22
/
2003
로티퍼는 해산어와 담수어뿐만 아니라 식용어와 관상어에 이르기까지 모든 어류의 인공 종묘 생산 과정에서 초기 먹이생물로 이용되고 있는 중요한 동물 플랑크톤이다. 그리고 로티퍼를 초기 자어의 첫 먹이로 사용하는 것을 시작으로 알테미아, 코페포다 또는 초미립자 사료 등을 사용하는 어류 인공종묘 생산 과정에서의 먹이계열이 확립되어 있다. 그러나, 사육하고자 하는 어종에 따라 초기 자어기에서 로티퍼를 섭이하는 시기와 사육 일령별 자어의 로티퍼 포식수를 알 수 있는 정확한 방법이 없다는 이유로 지금까지는 자어의 로티퍼 최초 포식 일령 및 로티퍼 포식수를 개개의 연구자들 나름대로의 방법으로 관찰하여 왔다. 일반적으로 자어가 로티퍼를 포식하였는지의 여부 및 포식수는 자어 소화기내에 존재하는 소화가 진행되기 전의 로티퍼 몸체의 수를 계수하는 방법으로 이루어졌다. 로티퍼의 체내에는 섬모환으로 모은 수중의 먹이 현탁액을 소화기계로 이동시키기 전에 먹이를 잘게 다지고 부수는 기능을 하는 저작기 (trophi)가 존재한다. 그리고 이 저작기는 로티퍼의 종에 따라서 다른 형태를 하고 있는 것으로 알려져 있다. 이 연구에서는 자어가 섭이한 로티퍼는 어류의 소화기내에서 소화가 진행되는 과정에서 로티퍼의 체 구조 중 저작기가 쉽게 소화되기 어렵고 소화기관의 연동 운동에 의해서도 쉽게 그 모양이 손상되지 않는다는 것을 발견하고 이 저작기의 수를 계수하므로서 로티퍼의 최초 섭이 일령 및 일령별 로티퍼 포식수를 계수할 수 있는 방법을 검토하였다. 그 결과, 소화기내의 잔존 로티퍼 몸체만으로 계수 관찰하던 기존 방법에 비교하여 로티퍼의 저작기를 계수하는 방법을 이용할 경우 보다 신뢰도가 높은 결과를 도출할 수 있음을 확인하였다. 경제적 가치의 우수성 때문만은 아니다. 미국은 자국의 대두 생산자들이 생산해 낸 대두를 판매하면서 조성한 자조금을 모아 대두의 생산성을 향상시키기 위한 연구 개발과 국내외 시장을 확대하기 위한 마케팅 활동에 쓰고 있다. 이런 자조 노력은 비단 미국의 대두 농민들에게만 국한된 것이 아니다. 가깝게는 일본의 수산업과 해산어 양식산업의 발전은 중앙 및 지방 정부, 수협과 같은 어민 조합 및 연근해 수산업 종사자들이 출연한 기금을 통해 이루어지고 있음을 지난 8월 북해도의 양식산업을 시찰했을 때 확인할 수 있었던 사실이다. 이제 우리나라도 국민소득 1만불 시대를 넘어 2만불 시대를 열기 위한 청사진을 그릴 만큼 모든 경제의 규모가 확대되었을 뿐 아니라 질적으로 고도화되었다. 우리에게 필요한 것은 성숙된 산업사회에 걸맞는 각 산업 주체들의 의식이다. 한국의 양식산업도 자조 정신을 갖추어 생산성 향상에 초점을 맞춘 양식기술의 개발, 환경 보전을 고려한 양식장 관리 및 소비를 확대하기 위한 유통시스템의 선진화에 스스로 투자를 해야 할 시기에 와 있다.치가 완전히 익은 15일 후에는 무첨가 김치, 0.1%, 0.2% 및 0.3% 고분자 키토산 김치의 젖산균 수는 5.4X107 cfu/g, 3.3X107 cfu/g, 8.6X106 cfu/g 및 2.6X106 cfu/g로 나타났다. 5. 발효가 진행 중에 대장균 군 수가 시간과 더불어 대장균군 수가 모든 구에 있어서 6일까지는 서서히 증가하다가 그 후부터는 대장균 군 수가 감소하였다. 즉, 발효초기에는 모든 구가 2.0X104∼4.0X105 cfu/g이었고, 6일 경에는 8.9X104∼4.5X105 cfu/g로 약간 증가하였으며 15일후에는 키토산 무첨가 김치가 2.0X
The study verified the extinguishing performance of the low pressure water-mist system, which is used to extinguish fire at domestic wooden architecture, through a fire test. Made of inflammable materials, a wooden house is vulnerable to fire, and the size of fire may vary from the early stage in case of arson. With the discharging pressure of 8 bar and the flow rate of 35 lpm, the low pressure water-mist nozzle used in the experiment has considerable discharging amount compared to other water-mist nozzles. The extinguishing performance was tested based on the size of fire and architecture. Test results demonstrated that the extinguishing performance was not affected by the size of a house, but decreased significantly when the size of fire was above unit 1. Taking into account that the environment of actual wooden cultural properties is more vulnerable than that of the experiment model, sufficient investigation on extinguishing performance is required to apply the water-mist extinguishing system to wooden architecture.
Journal of the Earthquake Engineering Society of Korea
/
v.16
no.4
/
pp.9-18
/
2012
In this study, a shaking table test was performed for the evaluation of water extinguishing facilities. Water extinguishing facilities, such as a general pipe, a seismic pipe (Loof type) and a pump, were used in the experiment. This captured the dynamic characteristics of water extinguishing systems by earthquake records at El-Centro with a 50%, 70%, 100%, 120% level. As a result, seismic type facilities have excellent seismic performance compared to general facilities. By using the acceleration response spectrum, not only is the performance evaluation of water extinguishing facilities able to be determined, but also the deformation of facilities in low earthquake levels can be known. This proposed approach can determine the seismic performance evaluation of water extinguishing facilities and verify seismic performance criteria.
Purpose: The study want to verify application the medium expantion foam extinguisher of expantion foam rate and fire extinguishing Performance test because the medium expansion system can maintain the discharge distance less affected by air currents, and the foam agent can be used efficiently. Method: For the study, the medium-expansion testing apparatus was manufactured and with synthetic surfactant foam agent of (class B) fire extinguishing model, and Fire Performance was analyzed for foam expansion rate and the fire agent consumption was measured and analyzed. Results: We measured the medium-spray testing apparatus and found that the expansion rate was 26.1 times. The test results of a 20-unit fire extinguishing model show that the extinguishing time is faster than the high and low foam expansion. It has been analyzed that it is possible to apply a hand-operated with a hose reel or medium expansion apparatus. Conclusion: Considering that the foaming agent and the extinguishing performance of the medium foam ratio are excellent, It is necessary to introduce the technical standards of medium foam agent for the introduction of hand-operated equipment, such as hose reel or portable medium foam apparatus.
The domestic wooden cultural properties applied to the sprinkler extinguishing system was confirmed extinguishing performance through fire experiments. Consists of wooden cultural properties of a fire, a flammable material is vulnerable in terms of. The scale of fire will occur to vary appearance of the initial fire in case of arson. Sprinkler nozzles of the characteristics, the discharging pressure is 1 bar and the flow rate is 80 lpm, applied in this experiment. Fire performance experiments were tested in two separated in each of the scale of the fire and cultural properties. Fire extinguishing performance test results was low in high ceilings and two or more units of the fire scale. Fire growth environment of the actual wooden cultural properties to experimental models when you consider that it is more vulnerable, sprinkler extinguishing system is required sufficient verification in order to apply fire protection of the wooden cultural properties.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.