• Title/Summary/Keyword: 소형 소각로

Search Result 33, Processing Time 0.023 seconds

Source Estimation of Dioxin in Soil Using a Congener Pattern (이성체 정보를 이용한 토양 중 다이옥신 오염원 해석)

  • Kim, Jong-Guk;Kim, Kyoung-Soo;Kim, Jae-Sik;Shin, Sun-Kyoung;Chung, Young-Hee;Chung, Il-Rok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.3
    • /
    • pp.316-322
    • /
    • 2005
  • In this study, the concentration of 17 dioxin congeners in the soil samples near a waste incinerator with respect to distance from incinerator and wind directions were investigated. The effect of PCB source was investigated using the cluster analysis method. The total concentration and I-TEQ concentration of dioxin ranged from 31.065 to 7,257.499 pg/g(dry weight) and from 0.099 to 35.191 pg I-TEQ/g(dry weight.), respectively. There was a weak correlation(not statistically significant) observed between soil concentration and wind direction, and the distance from the incinerator. The reason may be due to the presence of the local combustion sources other than the target incinerator. The fraction of PCDFs and PCDDs was also examined to study the effect of incinerator. The fraction of PCDFs was decreased with the distance from the incinerator. The influence of target incinerator was found within a 500-meter radius. The high concentration in the for site was due to small incinerators and the use of agricultural chemicals such as PCP. To investigate the relationship between soil near the incinerator and the sources, the cluster analysis was conducted using the congener pattern. As a result soil samples were divided into four groups and were qualitatively estimated the influence of sources such as incinerator and PCP by comparing the congener pattern of each roups. It was thought that a cluster analysis was a useful statistical method for the source estimation of dioxin.

A Study on the Combustion Characteristics of the Small Scale Cyclone Incinerate System for Sludge (슬러지용 소형 사이클론 소각 시스템의 연소특성에 대한 연구)

  • Park, Woo-Cheul;Lee, Hyun-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • The performance of the small scale cyclone incinerate system (100kg/hr) to process the sewage sludge containing high moisture is evaluated. The incinerate system design is based on properties of the domestic sewage sludge. The combustion characteristics of the incinerate system is tested and analyzed with the various operation conditions of the moisture level, the sludge feed rate and the auxiliary fuel feed rate. The pressure loss of the whole system is appeared relatively small of 700mmAq under the normal operating condition and the temperature distribution of the incinerator internal combustion is maintained less than 1000C. Auxiliary fuel of 4.7 1/hr is required to incinerate 100kg sludge which include 87% moisture. Because the inside temperature of the incinerator is maintained less than $1000^{\circ}C$, it is predicted that the most NOx measured is produced not from the heat during the combustion process but from the oxidation of the N ingredient in the sludge. From the component analysis of ash, the organic matter is not entirely detected. Accordingly, it is estimated that the complete combustion has been accomplished in the incinerator.

  • PDF

Analysis of the relationship between operational condition and temperature distribution in a small incinerator (소형 소각로에서 운전조건과 온도분포 사이의 관계 분석)

  • Kim, Sung-Joon;Park, Jong-Hwan;Chun, Bong-Jun
    • Journal of Industrial Technology
    • /
    • v.20 no.B
    • /
    • pp.63-70
    • /
    • 2000
  • One aims to find out how the operation condition of secondary inlet angle effects the temperature distribution inside a small incinerator. A finite volume commercial code, PHONICS, is used to simulate the temperature field in an incinerator. The computational grid system is constructed by Multi-Block technique. The governing equations based on the curvilinear coordinates are used. Numerical experiments are done with the five variations of secondary air inlet. The temperature distribution is quantified by the statistical deviation of temperature in an incinerator. The computational analysis says that the certain angle of secondary air inlet could improve the uniformity of temperature distribution in an incinerator.

  • PDF

Combustion and Emission Characteristics of High Calorific Industrial Waste Burned in a Small-scale Incinerator (고 발열량 산업폐기물을 처리하는 소형 소각로의 소각 및 배출 특성)

  • Lee, Gyo-Woo;Lee, Sung-Jun;Kim, Byung-Hwa;Lee, Seung-Woo;Jurng, Jong-Soo
    • Journal of the Korean Society of Combustion
    • /
    • v.7 no.2
    • /
    • pp.42-48
    • /
    • 2002
  • Experiments on burning process of the industrial wastes were performed on a nozzle-type grate in the industrial waste incinerator with a capacity of 160 kilograms per hour. The temporal variations of temperatures and concentrations of the exhaust gas were measured and analyzed. The synthetic leather waste with the moisture content less than 2% was used. The experimental results show that the CO concentration in the exhaust gas exceeds the limit, 600 ppm, and the gas temperature fluctuates too much when 8 kg of waste was supplied every 3 minutes, equivalent to the capacity of 160kg per hour. That is a typical burning mode of this high-calorific industrial waste. When the smaller unit waste input, 6kg per every 2 min 15 seconds was supplied, we could reduce the fluctuations of the furnace temperature and improve the exhaust emissions, especially the CO concentration.

  • PDF

Challenges of Medical Waste Treatment in Fiji (피지국에서의 의료폐기물 처리현황과 문제점)

  • Kim, Daeseon;Bolaqace, Josefa;Rafai, Eric;Lee, Chulwoo
    • Journal of Appropriate Technology
    • /
    • v.6 no.1
    • /
    • pp.37-44
    • /
    • 2020
  • Medical waste is any kind of waste that contains infectious material and recommended not to be transferred for infection control. As a means of disposal, incineration has better points than dumping or landfill in the quantity reduction, odorless and nonhazardous. However, open burning and incineration of health care wastes under bad circumstances, can result in the emission of environmental pollutants to air. A burial of biological waste brings pollution of soil and water. Most of sub divisional hospitals in Fiji transfer their medical wastes to divisional hospitals for incineration. In 2011, 62,518 kg of medical waste was incinerated in the three divisional hospitals. However, some medical wastes are considered as general waste and burnt or sent to landfill site, some are buried on site in some sub-divisional hospitals. In this regards, urgent education is necessary for awareness promotion to relevant personnel in medical waste treatment. On site incineration using small scale incinerator is more recommended than transportation of medical wastes treatment in Fiji. Moreover, remotely controllable and fixable small scale of incinerator is more desirable in sub-divisional hospitals. It is recommended that Fiji government to set up a legal framework for medical waste management (MWM), to develop specific guidelines for MWM, to set up a training system for MWM to ensure that all relevant personnel are trained, to develop a monitoring and supervision system for MWM, to clarify the future financing of MWM activities, and to improve the MWM infrastructure.

Development of the Small Wastes Incinerator with High Combustion Efficiency (연소효율이 우수한 소형 소각로의 개발)

  • 한돈희;하대성
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.81-85
    • /
    • 2000
  • In order to reduce emission of air pollutants from spot incineration, it is required to develope the combustion chamber of small wastes incinerator having combustion efficiency. The characteristics of combustion of the incinerator with combustion chamber having tangential angels with surface of 45$^{\circ}$of air supply nozzles were studied in accordance with non-grate, fixed-grate and shaking-grate in the combustion chamber. Combustion conditions were evaluated with combustion efficiency, emission of hazardous gases, temperatures, ignition loss of ash and so on. Combustion efficiencies were shown 73.9% for non-gate, 81.1% for fixed-grate and 89.0% for shaking-grate. Emissions of CO were revealed 6.52 ppm for non-grate, 273 ppm for fixed-grate and 224 for shaking-grate. Comprehensively evaluated, combustion conditions got better in order of shaking-grate, fixed-grate and non-grate. This study suggests that small wastes incinerator should have shaking-or fixed-grate in combustion chamber to get better combustion condition even though at expensive cost of manufacturing.

  • PDF