Analysis of the relationship between operational condition and temperature distribution in a small incinerator

소형 소각로에서 운전조건과 온도분포 사이의 관계 분석

  • 김성준 (강원대학교 기계메카트로닉스공학부) ;
  • 박종환 (서울정수기능대학 건축설비 자동화과) ;
  • 전봉준 (인천기능대학 자동차학과)
  • Published : 2000.12.31

Abstract

One aims to find out how the operation condition of secondary inlet angle effects the temperature distribution inside a small incinerator. A finite volume commercial code, PHONICS, is used to simulate the temperature field in an incinerator. The computational grid system is constructed by Multi-Block technique. The governing equations based on the curvilinear coordinates are used. Numerical experiments are done with the five variations of secondary air inlet. The temperature distribution is quantified by the statistical deviation of temperature in an incinerator. The computational analysis says that the certain angle of secondary air inlet could improve the uniformity of temperature distribution in an incinerator.

Keywords