• Title/Summary/Keyword: 소파성능

Search Result 34, Processing Time 0.023 seconds

Investigation of Applicability of OpenFOAM for Regular Wave Modeling of Floating Vertical Plate (부유식 연직판의 규칙파 모델링을 위한 오픈폼 적용성 검토)

  • Oh, Sang-Ho;Kim, Gunwoo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.6
    • /
    • pp.382-388
    • /
    • 2017
  • This study performed an OpenFOAM-based numerical modeling for simulating performance of wave reduction by a floating vertical plate. Based on the Waves2FOAM library, an internal wave generation and energy dissipation with sponge layers schemes were further implemented. The performance of wave generation and dissipation was first tested with a simple two-dimensional analysis. Then, numerical simulation was carried out with the experimental data of Briggs et al. (2001) for the two regular wave cases. In general, the modeling results agreed well with the experimental data, showing better agreement than the numerical analysis by WAMIT that is included in Briggs et al. (2001).

Analysis on Wave Absorbing Performance of a Pile Breakwater (파일 방파제의 소파성능 해석)

  • Cho, Il-Hyoung;Koh, Hyeok-Jun
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Based on the eigenfunction expansion method, the wave-absorbing performance of a square or circular pile breakwater was investigated. Flow separation resulting from sudden contraction and expansion is generated and is the main cause of significant energy loss. Therefore, evaluation of an exact energy loss coefficient is critical to enhancing the reliability of the mathematical model. To obtain the energy loss coefficient, 2-dimensional turbulent flow is analyzed using the FLUENT commercial code, and the energy loss coefficient can be obtained from the pressure difference between upstream and downstream. It was found that energy loss coefficient of circular pile is 20% that of a square pile. To validate the fitting equation for the energy loss coefficient, comparison between the analytical results and the experimental results (Kakuno and Liu, 1993) was made for square and circular piles with good agreement. The array of square piles also provides better wave-absorbing efficiency than the circular piles, and the optimal porosity value is near P=0.1.

Wave Control by an Array of N Bottom-Mounted Porous Cylinders (N개의 투과성 원기둥 배열에 의한 파랑제어)

  • 조일형
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.15 no.4
    • /
    • pp.232-241
    • /
    • 2003
  • The interaction of incident monochromiatic waves with N bottom-mounted porous circular cylinders is investigated in the frame of three-dimensional linear potential theory. The fluid domain is divided into N+l regions i.e. a single exterior region and N interior regions, and the diffraction potential in each fluid region is expressed by an eigenfunction expansion method (Williams and Li,2000). The analytic results show that the porous structure reduces both the wave forces and the run-up wave around the cylinder. To verify the developed model, the systematic model test with a line array of porous cylinders is conducted at the wave tank (30m$\times$7m$\times$1.5m). The analytic results are in good agreement with the experimental results within measured frequency range. It is concluded that the breakwater constructed with an array of porous circular cylinders shows the performance of an effective wave barrier together with the seawater-exchange effect and is considered to have vast potentials for the use of seawater-exchanging breakwater in the future.

Experimental Study on Effect of Hybrid Quay Wall According to Floating Breakwater (부유식 방파제에 따른 안벽 내 영향에 관한 실험적 연구)

  • Son, Hyok Jun;Cho, Yong-Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.53-53
    • /
    • 2011
  • 최근에 세계화, 무역자유화에 따른 컨테이너 물동량이 증가하고 있다. 그에 발맞추어 초대형 컨테이너선이 등장하게 되고 신개념, 고효율의 항만인프라의 도입이 요구되고 있다. 이런 배경에 따라 최근에 국내외에서 부유식 안벽에 관한 기술 개발 및 연구가 더욱 필요한 상황이다. 부유식 안벽은 이동가능한 부유식 구조로 기존 항만의 확장 또는 신규 항만 건설시 환경문제를 최소화하고 기항, 선박수 및 선박의 크기에 따른 안벽 배열을 최적화 할 수 있어 항만 기능을 고도화함으로써 녹색항만을 구현하는데 많은 기여를 하게 될 것이다. 특히 컨테이너선의 양현하역과 환적이 가능하게 되어 컨테이너 터미널의 화물처리능력을 확대할 수 있을 뿐 아니라 기항선박의 체류시간을 최소화 할 수 있는 장점이 있다. 또한, 우리나라는 삼면이 바다로 크고 작은 항만들이 해안선을 따라 위치하고 있다. 이러한 항만들을 안전하게 보호하기 위한 방파제는 항만 기본시설인 외곽시설 중의 가장 중요한 구조물이다. 국내에 설치된 방파제는 대부분 사석이나 케이슨을 이용한 중력식 방파제로써 해저에 고정되어 해수면상으로 건설되므로 항내 외 해수교환을 차단하여 항내 수질악화를 초래할 뿐만 아니라 수심에 따라 막대한 건설비용이 소요된다. 따라서 친환경적이고 경제적인 새로운 형식의 방파제에 대한 연구 및 개발이 필요한 실정이다. 그 중 하나의 대안인 부유식 방파제는 공사기간이 짧고 비교적 수심에 대한 제약이 없는 것이 특징이다. 또한 해수의 원활한 흐름이 가능하기 때문에 중력식 방파제에 비해 경제적이며, 환경적 측면에서 큰 장점이 있다. 하지만 아직까지 부유식 방파제에 대한 국내 및 해외에서의 연구는 이론적인 해석을 중심으로 이루어져 부유식 방파제 실용화를 위한 많은 연구가 수행되어야 할 것으로 판단된다. 본 연구에서는 부유식 안벽 내에서 정온도를 효과적으로 유지하기 위하여 부유식 방파제를 설치하고 소파성능과 부유식 안벽내의 영향성을 수리모형실험을 통해 분석하였다.

  • PDF

On the Efficiency of a Wave Absorber Using the Arrays of Upright Perforated Plates (직립 타공판 배열에 따른 소파 성능해석)

  • Cho, I.H.;Kim, H.J.;Choi, H.S.
    • Journal of Korean Port Research
    • /
    • v.10 no.1
    • /
    • pp.15-23
    • /
    • 1996
  • In this paper, the numerical model to analyze the wave absorbing performance of upright perforated plates is developed under the linear potential theory. If the drag force is dominent to the inertia force in passing perforated plate, the characteristics of perforated plates are determined by a nondimensionlized real-value of G or a length scaled real-value of a. The parameters (G,a), which depend on the drag coefficient, porosity and local shape of plates, can be readily obtained by simple experiments. We investigated the reflection coefficients over a wide frequency range according to the arrays of perforated plates with different values of G and a. We found that the wave absorbing system using the arrays of upright perforated plates is sufficient to install in the ocean engineering basin.

  • PDF

Study of Nearshore OWC Wave Power Absorbing Breakwater (연안고정식 파력발전 겸 OWC 방파제 성능연구)

  • Hong, Do-Chun;Shin, Seung-Ho;Hong, Key-Yong;Hong, Seok-Won
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.465-468
    • /
    • 2006
  • The wave power absorbing performance of a bottom-mounted oscillating water column (OWC) chamber structure is studied. The potential problem inside the chamber is solved by making use of the Green integral equation associated with the Rankine Green function while the outer problem with the Kelvin Green function taking account of fluctuating air pressure in the air chamber. The absorbed wave power, wave elevation inside the chamber, reflection coefficient and wave loads are calculated for various values of a parameter related to the fluctuating air pressure. The present methods can also be used for the design of a OWC breakwater which can absorb and reflect the incoming wave energy at the same time.

  • PDF

Analysis on the Reduction Effects of the Gravity Waves and Infra-Gravity Waves of Detached Submerged Breakwater by Field Monitoring (현장관측을 통한 이안소파잠제의 중력파 및 중력외파 저감효과 검토)

  • Jeong, Weon-Mu;Back, Jong-Dai;Choi, Hyukjin;Kim, Sang-Ik
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.2
    • /
    • pp.51-60
    • /
    • 2018
  • This study was conducted to observe the effects of gravity and infra-gravity wave of detached submerged breakwater in the coast of Yeongnang-dong, Sokcho, as analyzing continuous wave data by performing field observations on the front area (W0) and rear area (W1, W2). Wave transmission coefficient ($K_t$) of submerged breakwater was analyzed in two parts, short-period wave (gravity wave) and infra-gravity wave. The wave energy reduction effect was analyzed and compared with the value of the design. In case of above wave height 2.0 m at the front area (W0) of the submerged breakwater, the short-period wave height at point W1 is reduced by about 65% and the short-period wave height at point W2 is reduced by about 59%. The depth of crest of submerged breakwater conducted in a sea area differs from the design, and the wave energy reduction effect is analyzed to be smaller than the design plan. The infra-gravity waves were amplified to 2.11 and 1.71 at the W1 and W2 points, respectively, and the wave height at W2 point was smaller than that at W1 point.

Study on Optimum Condition of Water-Repellent Finishing For PPS Fabrics (PPS 원단의 발수가공을 위한 최적의 가공조건 고찰)

  • Lee, In-Yeol;Jeong, Go-Eun;Lee, Stephen
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.11a
    • /
    • pp.47-47
    • /
    • 2011
  • 국내의 기능성 난연성 섬유 제조기술은 원사 자체에 난연제가 포함된 상태인 난연 PET 원사나, 일반 PET 원단에 후방염 처리한 원단이 사용되기에 난연 방염성능이 만족스럽지 못하고 친환경적이지 못한 실정이다. 오늘날 세계 난연섬유 시장 규모는 10조원에 이르고 있으며 국내에서도 화재에 대한 경각심이 높아지는 추세이므로 기능성을 갖춘 고부가가치 난연소재의 개발이 시급하다. 폴리페닐렌술피드(PPS)는 내열성 및 내화학약품성이 뛰어난 열가소성 고분자로 용융방사가 가능하다. 난연성이 높은 양모섬유 또는 아크릴계 난연섬유, 아라미드 섬유 등은 비용 문제로 범용화에 한계가 있으므로 비교적 저렴한 PPS 섬유가 개발될 경우 범용화를 기대할 수 있다. 현재는 PPS 섬유가 특수한 용도에 주로 사용되고 있으나 우수한 난연 특성을 이용하여 일반 용도로의 사용 및 수요가 급격히 늘어날 것으로 예상되며 우선적으로 인테리어용 원단, 특히 커튼이나 소파용 원단으로 용도 전개가 가능할 것으로 판단하였다. 본 연구에서는 소파용 PPS 원단의 후가공 조건의 선정 및 불소계 발수방오가공을 위한 최적의 조건을 선정하고자 하였다. Padding(wet pick up율 $80{\pm}3%$)-Drying($105^{\circ}C$, 2.5min)-Curing은 시간은 1분으로 고정시킨 후, 온도를 150, 160, 170, 180, 190, $200^{\circ}C$에서 처리하여 Yellowness값을 측정한 결과, 온도가 높아질수록 Yellowness값이 커지는 것으로 미루어 보아 PPS원단은 높은 열에 영향을 받아 황변 현상이 일어나는 것으로 사료된다. 특히 $180^{\circ}C$를 기점으로 값에 큰 변화를 보였으므로 최적의 열처리 온도는 $170^{\circ}C$로 선정하여 이후의 실험을 진행하였다. 또한 큐어링 시간이 황변에 미치는 영향을 분석한 결과 온도에 의한 영향에 비해 적은 편으로 사료되었으나, 1.5min을 기점으로 Yellowess값이 높아졌으므로 최적의 열처리 시간을 1분으로 선정하였다. 최종 가공조건인 $170^{\circ}C$, 1분에서 처리한 시험포는 처리전 원단과 비교하였을 때, ${\Delta}$Yellowness가 2.84 정도로 나타났다. 그 후, PPS 원단에 불소가공제 (TG-991N, 동인텍스켐)의 적정 농도를 선정하기 위해 1~7%까지 농도를 높이며 처리한 결과, 불소가공제의 농도가 높아짐에 따라 황변현상이 나타남을 알 수 있었다. 농도가 높아짐에 따라 Yellowness값은 증가하다가 4% 이후 완만해지는 것을 알 수 있었으므로 IPA/Water Drop test와 발수도시험 (KS K 0590;2008)을 통해 적정 농도를 선정하였다. PPS 원단은 불소가공제의 농도가 높아짐에 따라 발수도가 우수해졌으며, 가공제 농도 3% 처리만으로도 우수한 발수도를 나타내었으나 100% 발수를 위해서는 가공제 농도가 5% 이상 처리되어야 하는 것을 확인할 수 있었다.

  • PDF

Measurements of the Heat Release Rate and Fire Growth Rate of Combustibles for the Performance-Based Design - Focusing on the Combustibles in Residential and Office Spaces (성능위주설계를 위한 가연물의 열발생률 및 화재성장률 측정 -주거 및 사무공간 가연물을 중심으로)

  • Nam, Dong-Gun;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.29-36
    • /
    • 2017
  • The design fire based on the heat release rate (HRR) of combustibles can significantly affect the assessment of fire safety in the performance-based design (PBD). In the present PBD, however, limited information in the foreign literature has been used without further verification due to the lack of fire information in domestic combustibles. The objective of this study is to provide information on the HRR and fire growth rate for various combustibles in residential and office spaces. To end this, the fire experiments were carried out with single and multiple combustibles. The peak HRR of combustibles used in the present study had a range of 36 kW~1,092 kW. The fire growth rates were also $0.003kW/s^2{\sim}0.0287kW/s^2$ and $0.003kW/s^2{\sim}0.0838kW/s^2$ for the residential and office spaces, respectively. In particular, a sofa had the highest fire risk in terms of the peak HRR and fire growth rate. Finally, a methodology for calculating the peak HRR in a space was proposed through correlation analysis between the peak HRR and exposed surface of various combustibles.