• Title/Summary/Keyword: 소음 정도,

Search Result 573, Processing Time 0.028 seconds

A Double Loop Control Model Using Leaky Delay LMS Algorithm for Active Noise Control (능동소음제어를 위한 망각형 지연 LMS 알고리듬을 이용한 이중루프제어 모델)

  • Kwon, Ki-Ryong;Park, Nam-Chun;Lee, Kuhn-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.28-36
    • /
    • 1995
  • In this paper, a double loop control model using leaky delay LMS algorithm are proposed for active noise control. The proposed double loop control model estimates the loudspeaker characteristic and the error path transfer function with on-line using only gain and acoustic time delay to reduce computation burden. The control of error signal through double loop control scheme makes the more robust cntrol system. The input signal of filter to estimate acoustic time delay is used difference between input signal of input microphone and adaptive filter output. And also, in nonstationary environments, the leaky delay LMS algorithm is employed to counteract parameter drift of delay LMS algorithm. For practical noise signal, the proposed double loop control model reduces noise level about 12.9 dB.

  • PDF

A Study on the Method of Assessing Spatial Speech Transmission Quality as an Indicator of Room Acoustics -Concentrated on the Articulation Test under Variable Ambient Noise- (건축 음향의 실내 청취조건 평가방법에 관한 연구-변동외부소음하의 명료도시험에 관하여-)

  • Han, Myung-Ho;Lee, Tae-Gang;Oh, Yang-Ki;Kim, Sun-Woo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.5-11
    • /
    • 1991
  • Articulation test is a good predictor of spatial speech transmission quality. Like many other languages, articulation testing method using Korean language was proposed in 1989, and which was proved as a valid indicator in rooms with static background noise. In this paper, the testing method is examined in variable noise conditions. According to the experiment performed in 26 classrooms with variable background noise, the proposed articulation testing method using Korean Language is still in variable conditions.

  • PDF

A Study on Variables of Aircraft Noise Survey in Korea (국내 항공기 소음 성가심 조사 설계 시 고려해야 할 변수에 관한 연구)

  • Lee, Ki-Jung;Lee, Kun;Chang, Seo-Il;Son, Jin-Hee;Lee, Yeon-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.742-749
    • /
    • 2006
  • For the purpose of finding if aircraft noise annoyance response is affected to variables when noise survey is performed, the questionnaire survey is conducted around the Gimpo International Airport in Seoul, Republic of Korea. This residential area is exposed to the aircraft noise and road traffic noise, simultaneously. Research areas are classified according to three different aircraft noise exposure levels expressed in WECPNL, under 75, between 75 and 80, and above 80 WECPNL, on aircraft noise map. The 7-step numerical magnitude with verbal category scales is used to measure the annoyance level. This surrey suggests that aircraft noise annoyance is not affected to an important extent by other noise sources (road traffic noise, community noise) and demographic variables (sex, age, education, occupation, dwelling type, length of residence). Aircraft noise annoyance would be related to complaint activity which is one of attitudinal variables.

  • PDF

Estimation of Excitation Force and Noise of Drum Washing Machine at Dehydration Condition using Phase Reference Spectrum (위상 기준 스펙트럼을 이용한 드럼 세탁기 탈수 행정시의 가진력 및 방사소음 예측)

  • Kim, Tae Hyeong;Jung, Byung Kyoo;Heo, So Jung;Jeong, Weui Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.7
    • /
    • pp.617-623
    • /
    • 2013
  • Accurate prediction of the radiated noise is important to reduce the noise of the washing machine. It is also necessary to predict the excitation force accurately because excitation force can induce noise. In order to predict the excitation force acting on the washing machine, this paper conducts source identification method by use of phase reference spectrum. In this method, the transfer function between the cabinet and the motor through FEM and the measured response from the surface of the cabinet is used. The analysis of the radiation noise from the identified exciting force has been investigated. The comparison between the predicted SPL and the measured SPL at 1m apart from the front side of the washing machine showed good tendency.

A Clinical Study on Binaural Hearing Aid (양이 보청효과에 관한 연구)

  • 김기령;김영명;심윤주
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1978.06a
    • /
    • pp.9.2-9
    • /
    • 1978
  • Monaural and binaural hearing aid performance under quiet and noisy conditions were compared in regard to (1) the degree of hearing impairment, (2) the symmetry of pure tone audiogram, (3) the automatic gain control of the hearing aid. (4) hearing impairement with recruitment and, word discrimination ability. Performance using binaural hearing aids was consistently superior to that using monaural hearing aids. The results were as follows. 1. Speech detection thresholds were enhanced by a mean of 4.25dB when tested with danavox 747 PP stereo type hearing aid and by a mean of 4.12 dB when tested hearing aids connected seperately to the right and left ears. 2. Binaurally tested speech reception thresholds were superior to monaurally tested thresholds by a mean of 3.56dB when tested in quiet and by a mean of 5.56dB when tested in noise. 3. Binaurally tested word discrimination scores were also superior by a mean of 17.09% in quiet and by a mean 19.63% in noise. 4. Both SRT and word discrimination scores were performed best by subjects with moderately-severe impairement. The performance by one mildly impaired subject was the poorest of all performances. The levels of performance order were; moderately-severe loss, severe loss. moderate loss and mild loss. 5. The data obtained using AGC aids when compaired with that of linear amplification show that when AGC aids were worn in both ears. the results were very poor but when one AGC aid was worn in one ear and linear amplification in the other. the results were good. 6. The advantages of binaural hearing aids were obvious even in cases 1) with great diferences in hearing thresholds between right and left ears, 2) when the subject was unable to discriminate words without vision and. 3) when the subject had extreme recruitme t phenomenon.

  • PDF

Noise Attenuation by Landscape Woody Plants - Comparisons as a Hedge Species Between Japanese Spindle Tree & Oriental Arbor-vitae - (조경수목(造景樹木)의 소음감쇠효과(騷音減衰効果)에 관(關)한 연구(硏究) - 사철나무와 측백나무 수벽(樹壁)의 비교분석(比較分析) -)

  • Kim, Yong Shik;Chang, Ho Gyeong;Kim, Ye Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.78 no.1
    • /
    • pp.30-34
    • /
    • 1989
  • Effects on noise attenuation of the hedge species, Thuja orientalis L. and Euonymus japonicus Thunb., widely used as road side hedges, were analysed at the frequencies of 1,000, 2,000 and 3,150 Hz., respectively. The present experiments were carried out both in the field and in a Semianechoic Chamber. As increasing the distances from the noise source, attenuation rates of noise level were increased at high frequencies. But the attenuation rates of the noise level at low frequencies showed varied as the distances increased, and this trend appeared to be caused by the influence of ground waves. Generally, in this experiment, Thuja orientalis L., which is a coniferous species, showed more effective on the abilities of noise attenuation than that of Euonymus japonicus Thunb., which is a broad-leaved evergreen species.

  • PDF

A Study on Traveling Characteristics and Evaluation about Noise of Hydraulic Turbine Dynamo in Dam (댐 수차 발전기 소음의 전달특성과 평가에 관한 연구)

  • Yun, Jae-Hyun;Kook, Jung-Hoon;Kim, Jae-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.7
    • /
    • pp.705-711
    • /
    • 2008
  • In case of the domestic condition, as the initiating from Sumjin River Dam, total 14 units of multipurpose dams had been constructed in 1965 for the roles of flood control, waterpower generation, irrigation, water supply, industrial water supply. In the case of such multipurpose dam, it produces electric energy by converting the potential energy utilizing its head and quantity of the water into kinetic energy. However, in this process, since during the time when the turbine connected to the hydraulic turbine dynamo revolves and there occurs a loud noise, it brings the physical, mental bad influences to those people also a decline of an effective working efficiency. On such point of view, after selection of various 16 measurement points, this study has measured and analyzed the travelling characteristics of noise generated at the hydraulic turbine dynamo in Daechung Dam, and also has evaluated the degree of indoor noise using the evaluation index such as PSIL, NC. As the result of noise-evaluation, in case of Daechung Dam, since the noise damage grade appears very seriously at various spaces, it is considering that its soundproof measure would be necessitated keenly. Also, it is considered that such data could be utilized as the valuable material hereafter for establishment of an efficient noise-reduction countermeasure and a comfortable working environment for the hydraulic turbine dynamo plant.

An Experimental Study of Permeable Concrete Pavement for Application (투수성 콘크리트포장의 실용화를 위한 실험적 연구)

  • 문한영;김성수;정호섭
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.3
    • /
    • pp.165-173
    • /
    • 1998
  • 투수성 콘크리트포장은 우천시 도로포장 노면의 배수, 차량 주행 안전성의 향상 및 소음의 저감등을 목적으로 개발된 포장이지만 주행환경 및 도로주변과의 환경조화에도 기여한다. 일반적인 배수성 아스팔트 콘크리트포장에서는 투수계수 1$\times$10-2cm/sec를 목표로 정하고 있으나 본 연구에서는 투수성 콘크리트포장의 실용화를 위한 연구의 일환으로 투수계수1$\times$10-1cm/sec를 목표로 정하여 골재의 최대치수, 잔골재율 및 단위시멘트량을 변화시킨 투수성 콘크리트의 공극률, 연속공극률 및 투수계수와 제강도를 측정한 결과에 대하여 고찰하였다. 투수성 콘크리트의 목표투수계수 1$\times$10-1cm/sec 일 때 공극률 및 연속공극률은 각각 15 %와 12%정도이며, 압축강도는 240kg/$\textrm{cm}^2$정도의값을 나타내었으며, 골재의 최대치수가 10~13mm일 경우, 잔골재율 10~20%, 단위시멘트량 380 kg/$\textrm{cm}^2$정도가 적절한 배합으로 생각된다.

On the Vibration Control of Ship (선박진동 제어기술에 관한 소고)

  • 이호섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.11-21
    • /
    • 1996
  • 선박은 화물 및 여객을 수송하는 해상교통 수단으로써 여객 및 승무원의 안락성, 탑재장비, 기기의 성능 보전 상, 화물 및 구조부재의 안전성 차원에서 진동제어가 주요 해결 기술의 하나이다. 또한 최근 선박의 대형화, 고속화로 인해 엔진과 프로펠러의 기진력은 커지는데 반해 구조 강도계산 기술의 발달로 인해 선체구조 경량화가 촉진되어 선체의 유연성이 커질 뿐 아니라 전통적인 선체 구조와 기관, 축계 강성사이의 균형이 깨어짐으로 선박의 진동제어는 더욱 중요시 되고 있다. 선박의 경우 건조 후에 진동제어를 위한 조치를 취하는 일은 매우 제한적이고 많은 비용이 들기 때문에 설계단게에서 선박진동제어를 위한 사전 노력이 충분히 이루어지는 것이 중요하다. 따라서 선박의 주 기진원인 프로펠러, 주기관 등의 기진력 자체를 적정화하는 노력과 함께 그로 인한 응답을 극소화하기 위해 설계 단계부터 인도까지 단게별로 많은 노력을 기울이고 있다. 단계별 진동제어의 한 예를 Fig.1에서 보여주고 있다[1]. 선체와 같이 복잡한 대형구조물의 진동특성 및 응답을 계산함에 있어서 컴퓨터의 발달과 유한요소법과 같은 해석기술의 발달로 실제 구조와 매우 유사한 3차원 모델링이 가능하게 되어 해석의 정도를 높일 수 있게 되었다. 그러나 프로펠러 기진력, 유체와의 연성효과, 감쇠특성 등을 정도 높게 산정하는 데는 아직도 많은 어려움이 있다. 이와같은 문제는 진동응답의 계산정도를 저하시키는 주요 요인이 되어 설게단계에서 충분히 진동 제어가 이루어졌다 하더라도 건조 후 실제운항 시 진동문제가 발생되는 경우가 있다. 건조 후 진동문제 발생시 구조변경을 통한 해결은 한계가 있기 때문에 각종 진동제어 장치의 연구개발이 최근에 활발히 이루어지고 있다[2]. 본 고에서는 설계단계에서부터 건조 후까지의 선박진동제어 과정[1,2,5,6]을 단계별로 고찰하여, 점점 까다로워져 가는 선박 진동규제[3,4]에 대처하고 승무원의 안락성에 대한 욕구, 구조물의 안전성, 장비의 성능보존이 만족되는 저진동 선박의 건조를 위해 향후 해결해야할 과제들을 도출하여 선박진동분야이 연구개발 방향을 제시하고자 한다.

  • PDF

The Effect of working Noise Exposure and Military Background on the Hearing Threshold (특수병과의 과거 군 소음 노출이 소음 노출 작업자의 청력에 미치는 영향)

  • Chung, Ho-Keun;Kim, Kyoo-Sang
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.2
    • /
    • pp.137-146
    • /
    • 2003
  • Objectives : Impaired hearing is a prevalent occupational hazard, not only in industry, but also in the armed forces. In military life, noise has unusual characteristics, and constitutes a serious hazard to hearing. The aim of this study was to analyze the hearing threshold data in order to compare the hearing loss among shipyard workers, representing different workers, and a military service background. Methods : A cross-sectional audiological survey, combined with a questionnaire study, was conducted on a stratified random sample of 440 shipyard workers, with long-term exposure to noise. The employees were divided into four groups, according to their working and military service backgrounds, in relation to their exposure to noise. Results : As expected, the working and military noise exposure group (Group I) had significantly poorer hearing than the other groups. The high frequencies (2-8 kHz) showed the greatest difference in terms of poorer fearing in both ears. The prevalence of noise-induced hearing loss (NIHL) was highest in Group I. A logistic regression analysis was applied to determine the dependence of the NIHL in relation to age, smoking, drinking, working duration, ear protection, past history of ear diseases, and working and military sonics backgrounds, on the noise exposure The important factors found to be related to the NIHL, in relation to noise exposure were: age, work duration, and working and military service backgrounds. The adjusted odds ratio estimates for NIML in the right ear were 4.5 times greater (95% CI 1.7-11.6) for the military noise exposed group, and 7.9 times greater (95% CI 2.0-31.3) for the working noise exposed group than in the controls. The hearing thresholds at the pure-tone average and 4 kHz were significantly increased with age and work duration with both the working and military service backgrounds. Conclusions : From these results, specific preventive programs were planned, which should be assessed by epidemiological surveillance of the military noise exposed population.